Oklahoma Gas & Electric Muskogee Generating Station Best ...
Oklahoma Gas & Electric Muskogee Generating Station Best ...
Oklahoma Gas & Electric Muskogee Generating Station Best ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Oklahoma</strong> <strong>Gas</strong> & <strong>Electric</strong><br />
<strong>Muskogee</strong> <strong>Generating</strong> <strong>Station</strong> – BART Determination<br />
May 28, 2008<br />
during periods of high capacity utilization. Therefore, baseline emissions (lb/hr) represent the<br />
highest 24-hour block emissions reported during the baseline period. Baseline emission rates<br />
(lb/mmBtu) were calculated by dividing the maximum hourly mass emission rate by the full load<br />
heat input to the boiler.<br />
Table 2-1<br />
Plant Operating Parameters for BART Evaluation<br />
Parameter <strong>Muskogee</strong> Unit 4 <strong>Muskogee</strong> Unit 5<br />
Plant Configuration Pulverized Coal-Fired Boiler Pulverized Coal-Fired Boiler<br />
Firing Configuration tangentially-fired tangentially-fired<br />
Plant Output 572 MW (gross) 572 MW (gross)<br />
Maximum Input to Boiler 5,480 mmBtu/hr 5,480 mmBtu/hr<br />
Primary Fuel subbituminous coal subbituminous coal<br />
Existing NOx Controls combustion controls combustion controls<br />
Existing SO2 Controls low-sulfur coal low-sulfur coal<br />
Existing PM10 Controls<br />
Baseline Emissions<br />
electrostatic precipitator electrostatic precipitator<br />
Pollutant<br />
Baseline Actual Emissions Baseline Actual Emissions<br />
lb/hr lb/mmBtu lb/hr lb/mmBtu<br />
NOx 2,710 0.495 2,863 0.522<br />
SO2 4,384 0.800 4,657 0.850<br />
PM10 101 0.018 134 0.024<br />
2.1 Presumptive BART Emission Rates<br />
In the final Regional Haze Rule EPA established presumptive BART emission limits for SO2 and<br />
NOx for certain electric generating units (EGUs) based on fuel type, unit size, cost effectiveness,<br />
and the presence or absence of pre-existing controls. 1 The presumptive limits apply to EGUs at<br />
power plants with a total generating capacity in excess of 750 MW. For these sources, EPA<br />
established presumptive emission limits for coal-fired EGUs greater than 200 MW in size. The<br />
presumptive levels are intended to reflect highly cost-effective technologies as well as provide<br />
enough flexibility to states to consider source specific characteristics when evaluating BART.<br />
The BART SO2 presumptive emission limit for coal-fired EGUs greater than 200 MW in size<br />
without existing SO2 control is either 95% SO2 removal, or an emission rate of 0.15 lb/mmBtu,<br />
unless a state determines that an alternative control level is justified based on a careful<br />
consideration of the statutory factors. For NOx, EPA established a set of BART presumptive<br />
1 See, 40 CFR 51 Appendix Y Part IV, and 70 FR 39131.<br />
9