Table 6.2 (continuted)

Method lxlm 1.5x1.5m 2x2m 3x3m 3x3m

A B c D E

McCarthy (1977) 441 351 319 319

-

Parry (1977) 1400 933 560 467 467

Spangler & Handy

(1982) 582 371 227 193 193

Van der V1ugt &

Rosenthal (1989) 85* 130* 200 180 180

Notes: *Bearing capacity controls.

All values of footing pressure in units ofkPa.

Observed data from FHW A footing load tests at Texas A&M.

As can be seen, there is a wide range of allowable values of bearing capacity indicated in

Table 6.2. The method proposed by Parry (1977) gives the best comparison with the observed

values for all footings and gives the correct trend of decreasing allowable pressure with increasing

size of footing.