Eurogen brochure_3.0
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
EDITION <strong>3.0</strong><br />
automaticheating.com.au<br />
<strong>Eurogen</strong><br />
Condensing Water Heater
<strong>Eurogen</strong> Condensing Water Heaters<br />
<strong>Eurogen</strong><br />
Condensing Water Heater<br />
200 – 2160kW<br />
<br />
Certified<br />
Efficiency<br />
High Water Volume Condensing Water Heaters with large capacity range.<br />
<strong>Eurogen</strong> Condensing Water Heaters are<br />
distinguished by their engineering excellence and<br />
superior design features. Manufactured in Europe<br />
by Unical and exclusively distributed in Australia by<br />
AHG, <strong>Eurogen</strong> provides a premium high efficiency<br />
heating solution built for performance and longevity.<br />
Its durability can be attributed to its full 316 Stainless<br />
Steel combustion chamber and heat exchanger,<br />
while its high efficiency is derived from its three pass<br />
design and unique, patented heat transfer system.<br />
Available in output ranges from 200kW to 2160kW,<br />
<strong>Eurogen</strong> Condensing Water Heaters constitute a<br />
range of reverse-flame condensing water heaters<br />
which fully conform to Australian Standards and<br />
are manufactured from AISI 316L stainless steel .<br />
The third pass of exhaust gases is through stainless<br />
steel tubes fitted with aluminium fins to maximise<br />
heat exchange. The water heater includes low<br />
temperature (Rbt) and high temperature (Rat)<br />
connections to keep return water temperatures as<br />
low as possible to maximise condensing benefit.<br />
Together with very low standby and chimney losses,<br />
net efficiencies of up to 109% can be achieved. Two<br />
return water connections are available allowing the<br />
differentiation of high or low temperature return<br />
water to create the optimum efficiency result<br />
depending on the application.<br />
Supplied with 1:5 modulating power burners.<br />
Product Quick Check<br />
Type<br />
Range<br />
Efficiency<br />
Outdoor Option<br />
Fuel Type<br />
Gas Approval Type<br />
Condensing Forced Draft<br />
200-2160kW<br />
109% (Net) 98% (Gross)<br />
Yes<br />
Natural Gas, LPG,<br />
Dual Fuel (Natural Gas/LPG)<br />
Type B<br />
Modulation 1:5<br />
Cascadeable Yes<br />
Max Pressure 600kPa<br />
Low Nox<br />
Yes<br />
Building J Code Yes<br />
2019 compliant<br />
2<br />
Automatic Heating
<strong>Eurogen</strong> Condensing Water Heaters<br />
Features<br />
• High efficiency condensing water heater ≤ 109%<br />
Nett. Exceptional heat transfer is achieved via the<br />
patented multi radial flue gas fins. <strong>Eurogen</strong> also<br />
incorporates 100 mm heat insulation to minimise<br />
radiation losses.<br />
• Balanced combustion chamber geometry for<br />
rapid heat transmission and clean and complete<br />
combustion.<br />
• Dual fuel burner configurations are available<br />
• Compact footprint and versatile design - three<br />
pass flue gas exhausts in two cylindrically arranged,<br />
stacked water heater drums. The 860mm water<br />
heater width (up to EG570) allows ease of plant<br />
room access and installation and the door can be<br />
hinged as right or left handed.<br />
• Large water volume provides good thermal<br />
stratification and allows the system to operate with<br />
just one primary pump, thereby reducing power<br />
usage.<br />
• Variable water flow allows varying of the water<br />
flow rate to match the combustion rate of the<br />
burner. As the burner modulates from high fire to<br />
low fire, the water flow can be varied from high<br />
to low. This maintains a constant ΔT through the<br />
water heater. Whether 20° or 30° ΔT is required,<br />
this can be maintained through all phases of<br />
combustion by varying the water flow to match the<br />
burner modulation. This maximises the amount of<br />
heat extracted from the flue gases and thereby<br />
increases efficiency.<br />
Advantages<br />
• Fully Stainless Steel - All parts of the <strong>Eurogen</strong><br />
Condensing Water Heater that come in contact<br />
with flue gas or condensate are made from<br />
stainless steel. This feature ensures the longevity<br />
of the water heater through resistance to corrosion<br />
from the acidic condensate created inside the<br />
water heater.<br />
• Certified Efficiency - The <strong>Eurogen</strong> Condensing<br />
Water Heater is manufactured in Italy and is<br />
professionally designed and built to perform to<br />
specification. Certified test results from a reputable<br />
laboratory are available prove its stated efficiency.<br />
• No return water temperature limitation - <strong>Eurogen</strong><br />
accommodates lower return water temperatures<br />
and can operate at a ΔT of up to 30°C.<br />
Full 316<br />
Stainless Steel<br />
combustion<br />
chamber and<br />
heat exchanger<br />
for maximum<br />
durability<br />
Enterprise Power<br />
burner with dual fuel<br />
standby capability<br />
High water content<br />
allows greater<br />
water temperature<br />
and flow variations<br />
Patented Multi Radial<br />
flue gas fins for<br />
superior heat transfer<br />
Automatic Heating 3
<strong>Eurogen</strong> Condensing Water Heaters<br />
Technical Drawings<br />
C.H. Flow<br />
C.H. Return<br />
High & Low Temp<br />
Burner<br />
Smoke Chamber<br />
Flue Connection<br />
Progressive<br />
Smoke Pipe<br />
Condensate<br />
Evacuation<br />
Water<br />
Heater Drain<br />
The <strong>Eurogen</strong> Condensing Fire Tube Water Heater combustion process is designed to maximise efficiency<br />
and performance. The hot combustion gases first pass down the centre and return along the wall of the<br />
combustion chamber. On reaching the specially contoured door of the water heater the gases are directed<br />
down into the stainless steel condensing tubes which comprise the heat exchanger and feature aluminium<br />
internal fins designed to maximise heat extraction.<br />
Performance Data<br />
Product Code<br />
Output<br />
50/30°C<br />
kW<br />
Net<br />
Efficiency<br />
50/30°C<br />
%<br />
Net<br />
Efficiency<br />
Part Load<br />
50/30ºC<br />
%<br />
Output<br />
80/60°C<br />
kW<br />
Net<br />
Efficiency<br />
80/60°C<br />
%<br />
Nominal<br />
Input<br />
MJ/hr<br />
Modulation<br />
Ratio<br />
Flow Rate<br />
Min/Max<br />
L/s**<br />
Waterside<br />
Pressure<br />
Drop kPa*<br />
Combustion<br />
Side<br />
Pressure<br />
Drop mbar<br />
Total<br />
Water<br />
Volume<br />
litres<br />
Dry Power Supply<br />
Weight V/A/Hz<br />
Kg<br />
EG200NG280MMDSAUA032 200 107 109 182.7 97.72 672.84 1.5 1.20/2.39 3.8 1.86 260 525 240/0.5/50<br />
EG290NG400MMDMAUA032 290 107 109 265.6 98.2 975.6 1:5 1.73/3.46 2.5 2.54 305 660 240/0.9/50<br />
EG400NG550MMDSAUA140EA 400 107 109 367.1 98.2 1345.68 1:5 2.39/4.78 3.2 3.23 332 800 240/0.62/50<br />
EG480NG550MMDSAUA140EA 480 107 109 440.7 99.2 1614.96 1:5 2.87/5.73 2 3.43 544 1007 240/1.24/50<br />
EG570P61MMDSAUA150EA 570 107 109 523.3 98.2 1917.72 1:5 3.41/6.81 2.9 3.92 515 1137 240/2.2/50<br />
EG700P65MMDSAUA150EA 700 107 109 642.6 98.2 2355.12 1:5 4.18/8.36 3 4.6 625 1376 415/4.4/50<br />
EG900P71MMDSAUA150EA 900 107 109 826.2 98.2 3027.96 1:5 5.38/10.75 3.7 5.88 664 1613 415/4.4/50<br />
EG1140P71MMDSAUA150EA 1140 107 109 1046.6 98.2 3835.44 1:5 6.81/13.62 3.5 7.35 1107 2158 415/6.0/50<br />
EG1420R75AMMDSAUA165EA 1420 107 109 1303.6 98.2 4777.56 1:5 8.48/16.96 4 8.82 1157 2443 415/6.0/50<br />
EG1820R92AMMDSAUA180EA 1820 107 109 1670.8 98.2 6123.24 1:5 10.87/21.74 3.9 9.02 1936 3458 415/8.0/50<br />
EG2160R92AMMDSAUA180EA 2160 107 109 1983 98.2 7267.32 1:5 12.90/25.80 5.5 9.8 1904 3765 415/11.0/50<br />
* Pressure losses for a water flow rate corresponding to a Δt of 15K<br />
** Minimum flow rate is for low load only.<br />
4<br />
Automatic Heating
<strong>Eurogen</strong> Condensing Water Heaters<br />
Dimensional Data<br />
EG200 – EG2160<br />
1 Panel board<br />
2 Flame sight glass<br />
T1 C.H. flow<br />
T2 Low temperature C.H. return<br />
T3 High temperature C.H. return<br />
T4 Expansion vessel connection<br />
T5 Water heater drain<br />
T6 Burner connection<br />
T7 Flue connection<br />
T8 Condensate drain<br />
Model A B C D E F G H I L M N O P* Q* R* S<br />
EG200 720 1450 1132 190 205 48 374 790 255 320 250 625 255 1248 610 1311 45<br />
EG290 790 1465 1282 190 235 55 402 900 231 359 250 625 275 1385 680 1314 60<br />
EG400 790 1755 1282 190 235 65 402 900 271 379 450 655 275 1385 680 1614 60<br />
EG480 854 1770 1472 190 270 67 494 1062 306 358 500 606 306 1585 750 1606 65<br />
EG570 854 1940 1472 190 270 67 490 1062 306 358 500 776 306 1585 750 1776 65<br />
EG700 894 1970 1612 190 292 65 523 1161 275 388 500 807 316 1715 790 1787 65<br />
EG900 894 2340 1612 190 292 65 523 1161 405 388 500 1047 316 1715 790 2157 65<br />
EG1140 1064 2360 1802 190 317 57 551 1287 289 624 900 547 390 1911 960 2157 55<br />
EG1420 1064 2740 1802 190 317 57 552 1287 459 624 900 757 390 1911 960 2537 55<br />
EG1820 1204 2980 2052 190 387 53 681 1493 372 563 785 1260 432 2165 1100 2752 95<br />
EG2160 1204 3204 2052 190 387 54 681 1493 371 563 1010 1260 432 2165 1100 2977 95<br />
All measurements in mm. *Minimum dimensions for water heater room access requirements<br />
T1 T2 T3 T4 T5 T6 T7 T8<br />
Model<br />
ISO 7/1UNI 2276 PN6 ISO 7/1 Ø mm Øi mm Øe mm<br />
EG200 DN 65 DN 65 DN 65 Rp 1½ Rp ¾ 180 202 40<br />
EG290 DN 80 DN 80 DN 80 Rp 2 Rp 1 180 252 40<br />
EG400 DN 80 DN 80 DN 80 Rp 2 Rp 1 180 252 40<br />
EG480 DN 100 DN 100 DN 100 Rp 2 Rp 1 220 302 40<br />
EG570 DN 100 DN 100 DN 100 Rp 2 Rp 1 220 302 40<br />
EG700 DN 125 DN 125 DN 125 DN 65 Rp 1 270 352 40<br />
EG900 DN125 DN125 DN125 DN 65 Rp 1 270 352 40<br />
EG1140 DN 150 DN 150 DN 150 DN 80 Rp 1½ 320 402 40<br />
EG1420 DN 150 DN 150 DN 150 DN 80 Rp 1½ 320 402 40<br />
EG1820 DN 200 DN 200 DN 200 DN 100 Rp 1½ 320 452 40<br />
EG2160 DN 200 DN 200 DN 200 DN 100 Rp 1½ 320 452 40<br />
Automatic Heating 5
<strong>Eurogen</strong> Condensing Water Heaters<br />
Case Studies<br />
Ravenhall Prison<br />
3 x <strong>Eurogen</strong> 2160kW<br />
Opening in late 2017, Ravenhall<br />
Correctional Centre redefines<br />
the role of the modern prison in<br />
contributing to safer Victorian<br />
Communities. AHG supplied<br />
3x <strong>Eurogen</strong> Condensing Water<br />
Heaters to provide heating &<br />
domestic hot water for the prison<br />
buildings.<br />
567 Collins Street,<br />
Melbourne<br />
2 x <strong>Eurogen</strong> 1800kW<br />
1 x <strong>Eurogen</strong> 600kW<br />
567 Collins Street is a 26-level<br />
premium grade office tower<br />
located on Melbourne’s<br />
prestigious Collins Street,<br />
between King and Spencer<br />
streets. AHG supplied 3x <strong>Eurogen</strong><br />
Condensing Water Heaters to<br />
provide 4,200kW of heating &<br />
domestic hot water.<br />
6<br />
Automatic Heating
<strong>Eurogen</strong> Condensing Water Heaters<br />
Canberra Airport<br />
2 x <strong>Eurogen</strong> 2160kW<br />
1 x <strong>Eurogen</strong> 600kW<br />
With the aim of developing<br />
Australia’s Greenest airport,<br />
the New Canberra Airport was<br />
designed to a high environmental<br />
standard, employing a variety of<br />
building and services systems<br />
including high quality and long life<br />
building materials. AHG supplied<br />
3x <strong>Eurogen</strong> Condensing Water<br />
Heaters to provide heating to the<br />
terminal buildings.<br />
Automatic Heating 7
Automatic Heating Global Pty Ltd<br />
T. +613 8352 7000<br />
E. sales@automaticheating.com.au<br />
67 Gateway Boulevard, Epping VIC 3076<br />
P.O. Box 35a Epping VIC 3076 Australia<br />
W. automaticheating.com.au 18677 210407