<strong>Thermex</strong> - <strong>Stainless</strong> <strong>Steel</strong> Hot Water <strong>Tanks</strong><br />
Indirect 2 Coils<br />
• Material - <strong>Stainless</strong> <strong>Steel</strong> 2205<br />
• Coil Material - AISI 316L<br />
• Insulation: 170-1000L<br />
- 50mm Rigid Polyurethane<br />
- 1500-5000L Expanded Foam Jacket<br />
• Outer Casing - Painted Galvanised Carbon <strong>Steel</strong>*<br />
• Coil Working Pressure - 600kPa<br />
• Tank working Pressure - 700kPa<br />
• Temperature & Pressure Relief Valve<br />
rated 99°C / 700kPa<br />
Specification<br />
170 - 1000L<br />
Model No.<br />
Capacity<br />
(Litres)<br />
Coil kW<br />
Top/<br />
Bottom<br />
Coil Flow<br />
Rate L/s<br />
Top/Bottom<br />
Coil Pressure<br />
Drop (kPa)<br />
Top/Bottom<br />
First hour delivery<br />
Capacity (L)<br />
(2 coils in parallel)<br />
External Dia.<br />
(Ø) mm<br />
Total<br />
Height<br />
(H) mm<br />
TSSI2C170 170 20 / 22 0.24 / 0.26 2.98 / 3.33 1959 550 1230 60<br />
TSSI2C200 200 22 / 32 0.26 / 0.38 2.98 / 15.71 2502 550 1410 60<br />
TSSI2C300 300 24 / 36 0.29 / 0.43 9.6 / 19.5 2850 620 1600 90<br />
TSSI2C400 400 24 / 48 0.29 / 0.57 1.59 / 10.53 3456 710 1550 100<br />
TSSI2C500 500 36 / 60 0.43 / 0.72 4.5 / 19.13 4578 710 1900 120<br />
TSSI2C750 750 87 / 120 1.04 / 1.43 28.95 / 47.7 9576 920 1800 160<br />
Weight<br />
(Empty)<br />
kg<br />
TSSI2C1000 1000 87 / 160 1.04 / 1.91 9.23 / 55.67 11521 920 2200 240<br />
170L - 1000L<br />
1500 - 5000L<br />
TSSU2C1500 1500 120 / 180 1.43 / 2.15 27.03 / 50.9 14250 1150 2400 270<br />
TSSU2C2000 2000 160 / 200 1.91 / 2.39 18.46 / 35.18 17280 1300 2400 340<br />
TSSU2C2500 2500 180 / 240 2.15 / 2.87 30.16 / 78.54 20310 1400 2800 420<br />
TSSU2C3500 3500 185 / 250 2.21 / 2.99 14 / 29.5 10632 1470 3300 655<br />
TSSU2C4000 4000 220 / 285 2.63 / 3.4 22.5 / 36 12286 1470 3800 850<br />
TSSU2C4500 4500 220 / 320 2.63 / 3.82 22.5 / 43 13338 1590 3300 885<br />
TSSU2C5000 5000 220 / 355 2.63 / 4.24 22.5 / 52 14390 1590 3800 1140<br />
Note: Flow rates in the coil are based on 20° ΔT (Inlet/Outlet Temperature = 80/60°C)<br />
1500L - 5000L<br />
SENSOR CIRCUIT<br />
HOT OUTLET<br />
SOLAR<br />
CONTROLLER<br />
SOLAR<br />
PUMPING<br />
STATION<br />
EXPANSION<br />
VESSEL<br />
PRESSURE<br />
RELIEF<br />
SEALED SYSTEM<br />
BOILER<br />
CENTRAL HEATING SUPPLIED BY BOILER<br />
COLD INLET<br />
6<br />