- 26 -<br />

As already stated, note that if the microPLC is used on chambers different from Challenge and Hygros<br />

(“standard chambers”), the meanings of some channels could be different from those reported here.<br />

Whre the DCTC term appears it means that the corrispondent columns of values are relative to the “Salt<br />

Fogs” systems.<br />

READING AREA<br />

The information in this area allows the user to know the general status of the system.<br />

According to the application to be developed only a part of these information could be necessary.<br />

Note that measures are multiblied by a factor whose value depends from the parameter. The factor is reported in each<br />

table (for example: PT100 n. 0 * 100 means that in the memory location the value is the temperature measure for<br />

PT100 number 0, multiplied by 100).<br />

PT100 MEASURES<br />

For Challenge/Hygros chambers the PT100 no. 0 is the probe of dry bulb, and the no. 1 is the probe of wet bulb.<br />

Note that the PT100 n. 0 is also copied into locatios 2036-2037 (Calculated Input Measures).<br />

ADDRESS MEANING<br />

2000-2001 PT100 NO. 0 * 100<br />

2002-2003 PT100 NO. 1 * 100<br />

2004-2005 PT100 NO. 2 * 100<br />

2006-2007 PT100 NO. 3 * 100<br />

2008-2009 PT100 NO. 4 * 100<br />

2010-2011 PT100 NO. 5 * 100<br />

ANALOGIC INPUTS MEASURES<br />

ADDRESS MEANING<br />

2012-2013 Low stage suction * 1000<br />

2014-2015 Low stage discharge * 1000<br />

2016-2017 High stage suction * 1000<br />

2018-2019 High stage discharge * 1000<br />

2020-2021 Analogic input No. 4 * 1<br />

2022-2023 Analogic input No. 5 * 1<br />

2024-2025 Analogic input No. 6 * 1<br />

2026-2027 Analogic input No. 7 * 1<br />

2028-2029 Analogic input No. 8 * 1<br />

2030-2031 Analogic input No. 9 * 1<br />

CALCULATED INPUTS MEASURES<br />

For standard chambers only 3 parameters are used. Note that the temperature reported below is the same value you can find in<br />

the PT100 measures table at address 2000; in effect it is the dry bulb temperature.<br />

Absolute humidity is the absolute value used by the chamber regulator to control the humidity in the chamber. It is normally not<br />

useful to the operator: Relative humidity and Temperature globally identify the status of the chamber.<br />

<strong>Serial</strong> <strong>com</strong>munications protocol vers. 2.02 Angelantoni Industrie Spa Massa Martana (PG) Italy