08.11.2022 Views

ELMARK-ELECTRICAL-EQUIPMENT-2024-GR

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ELR-A/ ELR-B<br />

ASYMMETRIC CYCLER TIMER, ELR-6<br />

Asymmetric cycle timer can be used for cycle delay control, providing periodic energizing, lighting<br />

control, regular room ventilation, pumps, heating control for electric circuit and etc..<br />

ELR-6 is easy for operation and has range of input voltage- from 24 till 240V AC/DC. This relay have<br />

2 time functions- Cycle beginning with pulse and cycle beginning with pause.<br />

APPLICATION<br />

• Control of industrial and home electrical<br />

appliances.<br />

• Control of lights, heating, motors, pump, fan<br />

and etc.<br />

TECHNICAL DATA<br />

• Voltage range: 12-240V; 50/60Hz<br />

• Output current: 2x16A (AC1)<br />

• Function: 2 time functions<br />

• Output type: 2xSPDT<br />

• Time ranges: 0.1s-2400h<br />

• Function setting: via 4 potentiometers on<br />

front panel<br />

• Time deviation: 10% mechanical setting<br />

• Repeat accuracy: 0.2% set value stability<br />

• Min. breaking capacity DC: 500mW<br />

• Reset time: max. 200ms<br />

• Over voltage category: III<br />

• Output indication: LED<br />

• Ingress protection: IP20<br />

• Mechanical life: 1x10⁷<br />

• Electrical life (AC1): 1x10⁵<br />

• Max. cable size: solid wire max. 2.5 mm2 and<br />

flexible wire 1.5 mm2<br />

• Size: 90x18x64 mm<br />

Catalogue<br />

number<br />

Type<br />

Dimensions (mm) Packing/<br />

Box (pcs)<br />

W H D<br />

50157 ELR-5 18 90 64 1/100<br />

INTERMEDIATE RELAYS, ELR-7 SERIES<br />

Intermediate Relays are used for switching larger load output, strengthen or multiplying contacts<br />

of the existing device or send signals to the relevant control elements concurrently.<br />

Relays from ELR-7 series are easy for operation and has different input voltages- from 12V DC, 24V<br />

AC/DC and 240V AC.<br />

FUNCTIONS<br />

• Instead of small contactors.<br />

• Increase the number of contacts.<br />

• Increase contact capacity.<br />

• Switch contact type.<br />

• Used as a switch.<br />

• Eliminate interference in the circuit.<br />

TECHNICAL DATA<br />

• Voltage range: 24V AC/DC and 230V AC<br />

• Output current: 16A (AC1)<br />

• Output type: 1xSPDT and 3xSPDT<br />

• Supply voltage tolerance: -15% +10%<br />

• Max. change over time: 40ms<br />

• Min. breaking capacity DC: 500mW<br />

• Over voltage category: III<br />

• Output indication: red LED<br />

• Protection degree: IP20<br />

• Mechanical life: 1x10⁷<br />

• Electrical life (AC1): 1x10⁵<br />

• Max. cable size: solid wire max. 2.5 mm2 and<br />

flexible wire 1.5 mm2<br />

• Size (HxWxD): 90x18x64 mm<br />

W<br />

W<br />

D<br />

D<br />

H<br />

H<br />

AUTOMATION | TIME RELAYS<br />

YEARS TOTAL<br />

5WARRANTY<br />

+<br />

3 standard<br />

2 extended<br />

ELR-C/ ELR-D<br />

Catalogue<br />

number<br />

Type<br />

Number<br />

of contact<br />

Voltage<br />

Packing/<br />

Box<br />

(pcs)<br />

50158 ELR-A 1xSPDT 24V AC/DC 1/100<br />

50159 ELR-B 1xSPDT 230V AC 1/100<br />

50160 ELR-C 3xSPDT 24V AC/DC 1/100<br />

50161 ELR-D 3xSPDT 230V AC 1/100<br />

ELR-C/ ELR-D<br />

ELR-A/ ELR-B<br />

Select language on<br />

page 168:<br />

BG<br />

BA<br />

CR DE EL FR HU IT RO RS<br />

Sl<br />

SK<br />

105