1.45I<br />

10000<br />

5000<br />

1000<br />

500<br />

100<br />

50<br />

10<br />

5<br />

1<br />

0.5<br />

0.1<br />

AUTOMATION | RESIDUAL CURRENT DEVICES<br />

2 3 5 10 20 30 40 60 80<br />

2 3 5 5<br />

4 4 4 5 X I n<br />

0.01<br />

0.006<br />

0.002<br />

0.001<br />

1.13In<br />

1.45In<br />

AC<br />

A<br />

1 2 3 5 10 20 30 40 60 80<br />

on Dimension(mm)<br />

YEARS TOTAL<br />

7WARRANTY<br />

+<br />

7 standard<br />

0 extended<br />

* for industrial usage<br />

3 years warranty<br />

B Curve<br />

current I<br />

ELECTRONIC RESIDUAL CURRENT t<br />

2<br />

I<br />

OPERATED 4<br />

I<br />

CIRCUIT 5<br />

t<br />

BREAKER (RCBO)- JEL4A,<br />

C Curve<br />

TYPE A CURVE C<br />

DS1 MAX-ELECTRONIC TYPE WITH MOUNTED MX+OF<br />

D Curve<br />

B Curve 1.13×I N ≥1h 3×I N<br />

≥0.1s<br />

1.45×I N 5×I N<br />

36<br />

T<br />

135°<br />

Thermal<br />

0.11I△n≤I△≤1.4I△n<br />

Tripping<br />

0.11I△n≤I△≤2I△n<br />

Magnetic Tripping<br />

1<br />

2<br />

81<br />

35.5<br />

As per<br />

IEC60898<br />

N<br />

N<br />

No<br />

50<br />

50<br />

66<br />

78 66<br />

78<br />

tripping<br />

Tripping<br />

current<br />

FUNCTIONS<br />

Switching off heavy-loaded electrical circuits at<br />

short circuit or overload.<br />

• Switching off heavy-loaded electrical circuits<br />

at insulation damage of the conductors to the<br />

consumers.<br />

• Switching off heavy-loaded electrical circuits<br />

at presence of a person and animals under<br />

voltage.<br />

• Switching off consumers at harmonic presence<br />

due to luminescent lights.<br />

• Switching off consumers in DC circuits at fault<br />

currents presence.<br />

• Used to protect not only particular consumers/circuits,<br />

but also the whole panel.<br />

• Remarkable with high reliability of current<br />

characteristics.<br />

• Control: manual switching on and automatic<br />

switching off at failure in the insulation after<br />

the breaker.<br />

MOUNTING<br />

• On DIN-rail<br />

• Mounting position: vertical<br />

The residual current device is mounted in<br />

the distribution box, and after the device the<br />

neutral conductor and the earthing conductor<br />

must not be connected together. In order to<br />

work accurately, the device must have three- or<br />

five-conductor grid with separate operating<br />

neutral conductor (N) and separate protecting<br />

conductor (PE) (e.g. earthing system TN-S or TT<br />

with three or five conductors).<br />

02<br />

45<br />

Time<br />

Limits<br />

Hold<br />

current<br />