08.11.2022 Views

ELMARK-ELECTRICAL-EQUIPMENT-2024-GR

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ication<br />

ess<br />

rate<br />

ing<br />

rature<br />

umidity<br />

awings<br />

AUTOMATION | MEASUREMENT DEVICES<br />

n<br />

envir<br />

on<br />

me<br />

nt<br />

1200bps~19200bps<br />

-25℃~+55℃<br />

≤95℅(No condensation)<br />

communication<br />

address<br />

Baud rate<br />

working<br />

temperature<br />

Relative humidity<br />

5 Dimension drawings<br />

YEARS TOTAL<br />

5WARRANTY<br />

+<br />

3 standard<br />

2 extended<br />

Fig1 direct connect<br />

Fig2<br />

1200bps~19200bps<br />

-25℃~+55℃<br />

≤95℅(No condensation)<br />

Fig1<br />

Fig2<br />

direct connect<br />

connect via CT<br />

Note:The torque of direct connect should not be greater than 3-4N·m,and the torque of<br />

via CT should not be greater than 1.5-2N·m。<br />

6 Wiring and installing<br />

6.1 Wiring sample of voltage and current<br />

connect via CT<br />

direct connect should not be greater than 3-4N·m,and the torque of<br />

greater than 1.5-2N·m。<br />

THREE PHASE MULTI TARIFF ELECTRIC ENERGY METER 10(80)A, ADL400<br />

connect<br />

ADL400 is a smart meter designed for power supply system, industrial and mining enterprises and<br />

utilities to calculate the electricity consumption and manage the electric demand. It features the<br />

high precision, small size and simple installation. It integrates the measurement of all electrical parameters<br />

with the comprehensive electricity metering and management provides various data on<br />

previous 48 months, checks the 31st harmonic content and the total harmonic content. It is fitted<br />

with RS485 communication port and adapted to MODBUS-RTU .ADL400 can be used in all kinds of<br />

control systems, SCADA systems and energy management systems.<br />

FUNCTIONS<br />

• Measurement of electrical parameters:<br />

kWh; voltage; current; active power ( positive<br />

and negative); reactive power ( positive and<br />

negative); apparent power; power factor and<br />

frequency<br />

• Measurement of harmonics: 2-31st voltage<br />

and current harmonic<br />

• Number of tariffs: 4<br />

• LED display: 12 bits section<br />

• Key programing: 3keys to communication<br />

and set parameters<br />

• Multi-tariff and functions: adapt 4 time zones,<br />

2 time interval list, 14 time interval by day and<br />

4 tariff rates<br />

• Max. demand and occurrence time<br />

• Frozen data on last 48 months, last 90 days<br />

• Communication interface: RS485<br />

• Communication protocol: MODBUS-RTU<br />

TECHNICAL DATA<br />

• Rated voltage: 3×100V; 3×380V; 3×57.7/100V;<br />

3×220/380V<br />

• Frequency: 45-65Hz, error±0.2%<br />

• Nominal input current: 3×1(6)A; 3×10(80)A<br />

• Power consumption: < 1VA Single phase rated<br />

current<br />

• Energy pulse output: 1 active photocoupler<br />

output<br />

connect<br />

• kWh Class: 0.5<br />

• Accuracy class: Error±0.2%<br />

• Time error: ≤0.5s/d<br />

• Width of pulse: 80±20ms<br />

Catalogue<br />

number<br />

Type<br />

Measuring<br />

range<br />

50212 ADL400 3×1(6)A /<br />

3×10(80)A<br />

• Pulse constant: 400imp/kWh,10000imp/<br />

kWh(Correspond with the basic current)<br />

• Range of communication address:<br />

Modbus-RTU: 1~247<br />

• Baud rate: 1200~19200bps<br />

• Size LxWxH: 72x65x90 mm<br />

• Working temperature: -25 o C~55 oC<br />

• Relative humidity: ≤95% ( No condensation)<br />

• Altitude: up to 2500m<br />

• Brand: Acrel<br />

Voltage Overall dimensions (mm) Packing/<br />

(V)<br />

L W H Box (pcs)<br />

3×220/380V 72 65 90 1/36<br />

stalling<br />

e of voltage and current<br />

-3-<br />

-3-<br />

MID<br />

Certified<br />

132<br />

<strong>ELMARK</strong><br />

Download BUSINESS APP from www.elmarkholding.eu or for mobile from or

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!