Insulation Fixings<br />
MDD-S Insulation Fixing, steel nail<br />
Applications<br />
soft insulating materials, thermal insulation composite systems, thermal<br />
insulation composite systems with rendering<br />
Features<br />
• European Technical Assessment according to ETAG014-<br />
A/B/C/D/E - (L ≥ 135mm)<br />
• European Technical Assessment according to ETAG014-<br />
A/B/C - (L ≤ 115mm)<br />
• Reduced point thermal transmittance to 0.001 W/K thanks to high<br />
steel nail overmould, which decreases facade heat losses<br />
• For all insulating materials<br />
• For the fixings in all substrates (according to ETICS)<br />
• Fixing system consisting of expansion plug with retaining disc<br />
(Ø 60mm) and expansion nail with special head<br />
• Excellent disc stiffness of 1.0 kN/mm<br />
• In combination with MDD-VZ discs (Ø90mm) for soft insulating<br />
material<br />
• Suitable for insulation thicknesses up to 270 mm<br />
• Short setting depth (ABCD = 25mm, E = 65mm)<br />
• Shock resistant material<br />
• For overhead applications please consult your local <strong>Mungo</strong><br />
application engineer<br />
• Through fixing<br />
Technical Data<br />
Concrete C12/15<br />
tension load (kN)<br />
Concrete C16/20 -<br />
C50/60<br />
tension load (kN)<br />
Brick<br />
tension load (kN)<br />
Calcium silicate<br />
brick tension load<br />
(kN)<br />
Perforated calcium<br />
silicate brick<br />
tension load (kN)<br />
Vertically perforated<br />
brick (Hlz 12)<br />
tension load (kN)<br />
Aerated Concrete<br />
tension load (kN)<br />
Drilling depth<br />
mm<br />
Drilling depth<br />
mm<br />
Drilling depth<br />
mm<br />
Effective anchorage<br />
depth mm<br />
Effective anchorage<br />
depth mm<br />
Effective anchorage<br />
depth mm<br />
h0 A, B, C h0 A, B, C, D h 0 E h ef A, B, C h ef A, B, C, D h ef E<br />
MDD-S (L ≤ 115mm) 0.43 0.43 0.43 0.43 0.32 0.21 - 35 - - 25 - -<br />
MDD-S (L ≥ 135mm) 0.4 0.43 0.43 0.43 0.4 0.18 0.36 - 35 75 - 25 65<br />
The partial safety factors of the resistances as well as a partial safety factor of the load of γF = 1.4 are considered / 1 kN ≈ 100 kg<br />
Installation<br />
5mm<br />
126 www.mungo.swiss