08.11.2023 Views

Mungo Main Catalogue

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Insulation Fixings<br />

MDD-S Insulation Fixing, steel nail<br />

Applications<br />

soft insulating materials, thermal insulation composite systems, thermal<br />

insulation composite systems with rendering<br />

Features<br />

• European Technical Assessment according to ETAG014-<br />

A/B/C/D/E - (L ≥ 135mm)<br />

• European Technical Assessment according to ETAG014-<br />

A/B/C - (L ≤ 115mm)<br />

• Reduced point thermal transmittance to 0.001 W/K thanks to high<br />

steel nail overmould, which decreases facade heat losses<br />

• For all insulating materials<br />

• For the fixings in all substrates (according to ETICS)<br />

• Fixing system consisting of expansion plug with retaining disc<br />

(Ø 60mm) and expansion nail with special head<br />

• Excellent disc stiffness of 1.0 kN/mm<br />

• In combination with MDD-VZ discs (Ø90mm) for soft insulating<br />

material<br />

• Suitable for insulation thicknesses up to 270 mm<br />

• Short setting depth (ABCD = 25mm, E = 65mm)<br />

• Shock resistant material<br />

• For overhead applications please consult your local <strong>Mungo</strong><br />

application engineer<br />

• Through fixing<br />

Technical Data<br />

Concrete C12/15<br />

tension load (kN)<br />

Concrete C16/20 -<br />

C50/60<br />

tension load (kN)<br />

Brick<br />

tension load (kN)<br />

Calcium silicate<br />

brick tension load<br />

(kN)<br />

Perforated calcium<br />

silicate brick<br />

tension load (kN)<br />

Vertically perforated<br />

brick (Hlz 12)<br />

tension load (kN)<br />

Aerated Concrete<br />

tension load (kN)<br />

Drilling depth<br />

mm<br />

Drilling depth<br />

mm<br />

Drilling depth<br />

mm<br />

Effective anchorage<br />

depth mm<br />

Effective anchorage<br />

depth mm<br />

Effective anchorage<br />

depth mm<br />

h0 A, B, C h0 A, B, C, D h 0 E h ef A, B, C h ef A, B, C, D h ef E<br />

MDD-S (L ≤ 115mm) 0.43 0.43 0.43 0.43 0.32 0.21 - 35 - - 25 - -<br />

MDD-S (L ≥ 135mm) 0.4 0.43 0.43 0.43 0.4 0.18 0.36 - 35 75 - 25 65<br />

The partial safety factors of the resistances as well as a partial safety factor of the load of γF = 1.4 are considered / 1 kN ≈ 100 kg<br />

Installation<br />

5mm<br />

126 www.mungo.swiss

Hooray! Your file is uploaded and ready to be published.