Insulation Fixings<br />
MIDS Insulation Nail<br />
Features<br />
• MIDS: Assessment of resistance under fire exposure F120<br />
• Cap reduces thermal transmission<br />
• In combination with MDB discs for soft insulating material<br />
• Stainless steel for outdoor applications<br />
• Suitable for overhead fixings<br />
• Through fixing<br />
Applications<br />
soft insulating materials, pressure-resistant insulating materials, mineral<br />
wools, glass wools, wood-wool building slabs<br />
Technical Data<br />
Concrete C20/25<br />
tension load (kN)<br />
Brick<br />
tension load (kN)<br />
Perforated Brick<br />
tension load (kN)<br />
Lightweight<br />
Concrete<br />
tension load (kN)<br />
Drilling depth<br />
concrete mm<br />
Drilling depth<br />
concrete mm<br />
(F120)<br />
Drilling depth<br />
perforated<br />
brick mm<br />
Setting depth<br />
concrete mm<br />
Setting depth<br />
concrete mm<br />
(F120)<br />
Setting depth<br />
perforated<br />
brick mm<br />
Effective<br />
anchorage depth<br />
min. concrete<br />
mm<br />
Effective<br />
anchorage depth<br />
min. concrete mm<br />
(F120)<br />
Effective<br />
anchorage depth<br />
min. perforated<br />
brick mm<br />
h 0 h 0 h 0 h nom h nom h nom h ef h ef h ef<br />
MIDS 8x50 0.3 0.3 0.1 0.1 35 - 45 30 - 40 25 - 35<br />
MIDS 8x80 0.3 0.3 0.1 0.1 35 45 45 30 40 40 25 35 35<br />
MIDS 8x90-8x300 0.3 0.3 0.1 0.1 40 50 50 30 40 40 25 35 35<br />
MIDSr 8x90-8x300 0.3 0.3 0.1 0.1 40 - 50 30 - 40 25 - 35<br />
MIDS-K 8x80 0.3 0.3 0.1 0.1 35 - 45 30 - 40 25 - 35<br />
MIDS-K 8x90-8x300 0.3 0.3 0.1 0.1 40 - 50 30 - 40 25 - 35<br />
Safety factor of 3 is included / 1 kN ≈ 100 kg<br />