Mungo Main Catalogue
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Metal Products<br />
m2-C Throughbolt, ETA Option 7<br />
Applications<br />
wooden constructions, distance fixing<br />
Features<br />
• European Technical Assessment Option 7 for non-cracked concrete<br />
• Higher loads, higher security<br />
• Improved clip design; higher loads and best expansion<br />
• With a big DIN 9021 washer for fixings with slotted holes and for<br />
wooden structures<br />
• Small edge and spacing distances<br />
• Highest shear loads and bending moment for safe distance fixing<br />
• Setting depth mark for correct installation<br />
• Simple setting process due to low resistance to impacts<br />
• Fast achievement of installation torque<br />
• Zinc plated > 5μm<br />
• Pre installation or through fixing<br />
• Indoor applications<br />
Technical Data<br />
Concrete C20/25<br />
Concrete C20/25 Bending moment (Nm) Min. distance betw. anchors/ Min. edge distance/at Minimum thickness of Installation torque (Nm)<br />
Wrench size<br />
tension load (kN)<br />
shear load (kN)<br />
at edge distance mm distance betw. anchors mm concrete member mm<br />
s min /c c min /s h min T inst SW<br />
M8 5.7 6.1 14.9 45/45 45/45 100 15 13<br />
M10 7.6 10.1 31.9 50/50 50/50 120 30 17<br />
M12 9.5 13.7 52.3 75/80 75/80 140 50 19<br />
M16 11.9 15.7 118.6 100/190 130/190 160 100 24<br />
The partial safety factors of the resistances as well as a partial safety factor of the load of γF = 1.4 are considered / The technical data is only valid for single fixings without consideration of edge and anchor distances / Only<br />
valid for setting depths according to assessment / 1 kN ≈ 100 kg<br />
Installation<br />
32 www.mungo.swiss