Chapter 6 Troubleshooting and Diagnostics Installation and Operation Manual<br />

Code Message Type<br />

2026 TFTP PROCESS<br />

COMPLETED<br />

Default<br />

Severity<br />

SL(CL) Event TFTP process completed<br />

2027 TFTP PROCESS ABORTED SL(CL) Event TFTP process aborted<br />

Interpretation<br />

2028 CL OVERHEATED SL(CL) Major The corresponding CL module reports excessive internal<br />

temperature.<br />

This may occur because the cooling vents have been<br />

obstructed, or because of a failure of the internal cooling fan:<br />

in this case, replace immediately the module<br />

2029 SFP NOT EXIST SL Major The corresponding SFP is not inserted.<br />

If the corresponding socket is occupied by an SFP, first try to<br />

remove it, and then reinsert the SFP<br />

2030<br />

to<br />

2059<br />

Reserved for future use N/A N/A N/A<br />

I/O Module Ethernet Port Alarms (M8E1/M8T1/M8SL/OP-108C/OP-106C)<br />

2060 LAN NOT CONNECTED SL:CH Major No signal on Ethernet port (this alarm will not appear when<br />

the user disables the corresponding LAN port)<br />

2061 LCP FAIL E1 1 SL: BND Major<br />

2062 LCP FAIL E1 2 SL: BND Major<br />

2063 LCP FAIL E1 3 SL: BND Major<br />

2064 LCP FAIL E1 4 SL: BND Major<br />

2065 LCP FAIL E1 5 SL: BND Major<br />

2066 LCP FAIL E1 6 SL: BND Major<br />

2067 LCP FAIL E1 7 SL: BND Major<br />

2068 LCP FAIL E1 8 SL: BND Major<br />

PPP LCP protocol failure on specified E1 port of an MLPPP<br />

bundle<br />

2069 BCP FAIL SL:BND Major PPP BCP protocol failure for the MLPPP bundle<br />

2070 PHYSICAL LOOP DETECTED SL:CH Major Physical loopback detected on one of the E1 ports included in<br />

an MLPPP bundle<br />

2071 OAM REMOTE FAILURE SL:BNDETH Major Remote failure occured. The failure is discovered by OAM<br />

message process. This alarm is relevant for both bundles and<br />

Ethernet ports<br />

2072 PORT DOWN DUE TO FP SL:CH Major Port operation status changed to Down by the fault<br />

propagation mechanism<br />

1104<br />

to<br />

1200<br />

Reserved for future use N/A N/A N/A<br />