D. CABINET<br />
Steel W x H x D 760 x 760 x 210 (1 x distributor with 1 to 4 outlets)<br />
Steel W x H x D 760 x 760 x 210 (1 x distributor with 5 to 8 outlets)<br />
E. NUMBER OF MONITORED OUTLETS<br />
without<br />
1 outlet<br />
2 outlets<br />
3 outlets<br />
4 outlets<br />
5 outlets<br />
6 outlets<br />
7 outlets<br />
8 outlets<br />
F. SOLENOID VALVES AIR<br />
without<br />
1 x 2/2-way solenoid valve 24 V DC<br />
1 x 2/2-way solenoid valve 110 V AC<br />
1 x 2/2-way solenoid valve 230 V AC<br />
G. ACCESSORIES<br />
without<br />
3. Application<br />
The <strong>SKYJET</strong> distributor cabinet serves to dose and distribute the air-oil mixture to the relevant lube points.<br />
The cabinet (in larger-size facilities several cabinets) is arranged in a decentralized location. Oil supply is<br />
accomplished via the upstream oil lubrication unit.<br />
4. Design and Function<br />
The distributor cabinet accommodates a filter regulator with pressure gauge for compressed-air supply and<br />
a socket ball cock. Compressed-air feed is via a downstream 2/2-way solenoid valve. The air pressure is<br />
monitored by a suitable pressure switch. <strong>Distribution</strong> of the oil volume is accomplished via a progressive<br />
group-lubrication distributor. The design of the outlets depends on the requirements of the system. An<br />
upstream 2/2-way solenoid valve takes care of controlling the oil feed to the progressive distributor.<br />
Distributor monitoring is ensured by a proximity switch within the mix block. All electrical components are<br />
wired up to a terminal block in a terminal box.<br />