Operation<br />

total stroke = 940 mm<br />

Arm<br />

max. weight = 800 kg<br />

Implement<br />

-- Program the panel in multipurpose 10.<br />

-- To couple an implement:<br />

� when the arm is lowered, the distributor (307)<br />

is open, thus:<br />

� Lifting of the arm with the control valves (48)<br />

SECTION 88 - ACCESSORIES - CHAPTER 1 19<br />

and (49) operated by the switches B1 and B2<br />

� The extension cylinder is powered by the<br />

control valves (32) and (33) operated by the<br />

switch (64).<br />

� The sloping of the plate can be obtained by<br />

the control valves (30), (31) and (45) oper-<br />

ated by the switch (63).<br />

NOTE: when the arm is not fully lowered, the control<br />

valve (307) closes the circuit preventing its exten-<br />

sion.<br />

The arm extension can be used at any height. To this<br />

purpose:<br />

- put the arm fully down,<br />

- tighten the screws (a) to lock the part (b), thecon-<br />

trol valve (307) is pressed.<br />

TELESCOPING ARM<br />

-- When the implement is definitely coupled, re-<br />

tract the arm fully, put the implement vertical<br />

and lift it, then:<br />

� Lifting of the arm with the control valves (48)<br />

and (49) operated by the switches B1 and B2<br />

� The outputs H3 and H4 are powered by the<br />

control valves (30) (31) and (25) operated by<br />

the switches (A1) and (A2).<br />

� The outputs H1 and H2 are powered by the<br />

control valves (30 ) (31) and (295) operated<br />

by the switches (C1) and (C2).<br />

� The control valves (32) and (33) operated by<br />

the switch (64) cannot power the extension<br />

cylinder anymore.<br />

� The sloping of the plate can be obtained by<br />

the control valves (30), (25) and (45) oper-<br />

ated by the switch (63).<br />

NOTE: other multipurpose functions can be used de-<br />

pending on the connected implements (see table).<br />

For the pre -cutter, use the multipurpose 9.<br />

SP Shaking circuit supply<br />

SR Shaking circuit return<br />