Nominal data<br />

Type<br />

R3G 280-RU26 -81 (1)<br />

subject to alterations<br />

16<br />

Curves<br />

p fs Pa<br />

600<br />

500<br />

400<br />

300<br />

200<br />

100<br />

in H 2O<br />

0,4 0,8 1,2 1,6 2,0 2,4<br />

q V<br />

Motor<br />

M3G084-CF<br />

4<br />

Curve<br />

A<br />

(1) 24-volt variant<br />

Nominal voltage<br />

EC centrifugal fans RadiCal<br />

backward curved, Ø 280<br />

- Material: Impeller: PA plastic, coloured black, con<strong>for</strong>ms to EN 45545 (R25-HL3)<br />

Rotor: Coated in black<br />

Electronics housing: Die-cast aluminium<br />

- Direction of rotation: Clockwise, seen on rotor<br />

- Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K<br />

- Insulation class: “B” in accordance with EN 60335-1<br />

- Mounting position: Any<br />

- Mode of operation: Continuous operation (S1)<br />

- Bearings: Maintenance-free ball bearings<br />

- Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,<br />

load dump protection, under-voltage detection<br />

- EMC requirements: VDE 0879-2, interference suppression grade 5<br />

- Qualified to: ISO 16750<br />

Flow rate<br />

0 200 400 600 800 1000 1200 1400<br />

1<br />

1600<br />

400 800 1200 1600 2000 2400 2800m<br />

3 /h<br />

3<br />

Nominal voltage<br />

range<br />

speed/rpm<br />

Input power<br />

VDC VDC m 3 /h rpm W A dB(A) °C kg<br />

26 16-32 2750 2350 252 10,5 72 -40..+60 2,8 p. 47<br />

2<br />

A<br />

cfm<br />

Current draw<br />

Air per<strong>for</strong>mance measured<br />

as per: ISO 5801,<br />

Installation category A,<br />

in ebm-papst full nozzle<br />

and without protection against<br />

accidental contact<br />

Suction-side noise levels:<br />

LpA measured at 1 m distance<br />

to fan axis<br />

The acoustic values given are<br />

only valid under the measurment<br />

conditions listed and<br />

may vary depending on the<br />

installation situation.<br />

With any deviation to the standard<br />

setup, the specific values<br />

have to be checked and reviewed<br />

once installed or fitted!<br />

For detailed in<strong>for</strong>mation<br />

see page 50 ff.<br />

Sound pressure level<br />

A<br />

A<br />

A<br />

A<br />

1<br />

2<br />

3<br />

4<br />

Perm. amb. temp.<br />

n<br />

rpm<br />

2350<br />

2300<br />

2265<br />

2315<br />

Mass<br />

P ed<br />

W<br />

252<br />

300<br />

328<br />

298<br />

Electr. connection<br />

I<br />

A<br />

10,5<br />

12,5<br />

13,7<br />

12,4<br />

L p A<br />

dB(A)<br />

72<br />

68<br />

68<br />

69