Nominal data<br />
Type<br />
R3G 280-RU26 -81 (1)<br />
subject to alterations<br />
16<br />
Curves<br />
p fs Pa<br />
600<br />
500<br />
400<br />
300<br />
200<br />
100<br />
in H 2O<br />
0,4 0,8 1,2 1,6 2,0 2,4<br />
q V<br />
Motor<br />
M3G084-CF<br />
4<br />
Curve<br />
A<br />
(1) 24-volt variant<br />
Nominal voltage<br />
EC centrifugal fans RadiCal<br />
backward curved, Ø 280<br />
- Material: Impeller: PA plastic, coloured black, con<strong>for</strong>ms to EN 45545 (R25-HL3)<br />
Rotor: Coated in black<br />
Electronics housing: Die-cast aluminium<br />
- Direction of rotation: Clockwise, seen on rotor<br />
- Type of protection: Motor: IP 24 KM, Electronics: IP 66 / 69 K<br />
- Insulation class: “B” in accordance with EN 60335-1<br />
- Mounting position: Any<br />
- Mode of operation: Continuous operation (S1)<br />
- Bearings: Maintenance-free ball bearings<br />
- Motor protection: Overtemperature protection, reverse polarity and locked-rotor protection,<br />
load dump protection, under-voltage detection<br />
- EMC requirements: VDE 0879-2, interference suppression grade 5<br />
- Qualified to: ISO 16750<br />
Flow rate<br />
0 200 400 600 800 1000 1200 1400<br />
1<br />
1600<br />
400 800 1200 1600 2000 2400 2800m<br />
3 /h<br />
3<br />
Nominal voltage<br />
range<br />
speed/rpm<br />
Input power<br />
VDC VDC m 3 /h rpm W A dB(A) °C kg<br />
26 16-32 2750 2350 252 10,5 72 -40..+60 2,8 p. 47<br />
2<br />
A<br />
cfm<br />
Current draw<br />
Air per<strong>for</strong>mance measured<br />
as per: ISO 5801,<br />
Installation category A,<br />
in ebm-papst full nozzle<br />
and without protection against<br />
accidental contact<br />
Suction-side noise levels:<br />
LpA measured at 1 m distance<br />
to fan axis<br />
The acoustic values given are<br />
only valid under the measurment<br />
conditions listed and<br />
may vary depending on the<br />
installation situation.<br />
With any deviation to the standard<br />
setup, the specific values<br />
have to be checked and reviewed<br />
once installed or fitted!<br />
For detailed in<strong>for</strong>mation<br />
see page 50 ff.<br />
Sound pressure level<br />
A<br />
A<br />
A<br />
A<br />
1<br />
2<br />
3<br />
4<br />
Perm. amb. temp.<br />
n<br />
rpm<br />
2350<br />
2300<br />
2265<br />
2315<br />
Mass<br />
P ed<br />
W<br />
252<br />
300<br />
328<br />
298<br />
Electr. connection<br />
I<br />
A<br />
10,5<br />
12,5<br />
13,7<br />
12,4<br />
L p A<br />
dB(A)<br />
72<br />
68<br />
68<br />
69