Fans for rail technology version 2012-09
Fans for rail technology version 2012-09
Fans for rail technology version 2012-09
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Nominal data<br />
Type<br />
A3G 350-AT00 -01 (2)<br />
subject to alterations<br />
40<br />
Curves<br />
p fs Pa<br />
110<br />
100<br />
90<br />
80<br />
70<br />
60<br />
50<br />
40<br />
30<br />
20<br />
10<br />
in H 2O<br />
0,1 0,2 0,3 0,4<br />
Motor<br />
M3G074-CF<br />
Curve<br />
A<br />
Nominal voltage<br />
EC axial fans - HyBlade ®<br />
Ø 350<br />
Flow rate<br />
speed/rpm (1)<br />
Max.<br />
Input power (1)<br />
Max:<br />
Current draw (1)<br />
VDC VDC m 3 /h rpm W A Pa dB(A) °C kg<br />
110 77-145 2150 1475 165 1,50 100 59 -25..+60 2,5 p. 49<br />
(1) Nominal data in operating point with maximum load and 110 VDC (2) Availability scheduled <strong>for</strong> second quarter 2013<br />
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 cfm<br />
qV 500 1000 1500 2000 2500 3000 3500 m3 /h<br />
4<br />
3<br />
– Material: Impeller: PA plastic<br />
Rotor: Coated in black<br />
Electronics housing: Die-cast aluminium<br />
– Number of blades: 5<br />
– Direction of rotation: Counter-clockwise, seen on rotor<br />
– Type of protection: IP 44<br />
– Insulation class: "B"<br />
– Mounting position: Shaft horizontal or Rotor on top, rotor on bottom on request<br />
– Conensate discharges: Rotor-side<br />
– Mode of operation: Continuous operation (S1)<br />
– Bearings: Maintenance-free ball bearings<br />
Nominal voltage<br />
range<br />
2<br />
1<br />
A<br />
Air per<strong>for</strong>mance measured<br />
as per: ISO 5801,<br />
Installation category A,<br />
in ebm-papst full nozzle<br />
and without protection against<br />
accidental contact<br />
Suction-side noise levels:<br />
LpA measured at 1 m distance<br />
to fan axis<br />
The acoustic values given are<br />
only valid under the measurment<br />
conditions listed and<br />
may vary depending on the<br />
installation situation.<br />
With any deviation to the standard<br />
setup, the specific values<br />
have to be checked and reviewed<br />
once installed or fitted!<br />
For detailed in<strong>for</strong>mation<br />
see page 50 ff.<br />
Max. Gegendruck<br />
A<br />
A<br />
A<br />
A<br />
1<br />
2<br />
3<br />
4<br />
Sound pressure level (1)<br />
n<br />
rpm<br />
1575<br />
1555<br />
1530<br />
1475<br />
Perm. amb. temp.<br />
P ed<br />
W<br />
141<br />
152<br />
161<br />
165<br />
Mass<br />
I<br />
A<br />
1,28<br />
1,38<br />
1,46<br />
1,50<br />
Electr. connection<br />
L p A<br />
dB(A)<br />
64<br />
62<br />
59<br />
59