10.01.2013 Views

Fans for rail technology version 2012-09

Fans for rail technology version 2012-09

Fans for rail technology version 2012-09

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

48<br />

Electrical connections<br />

L) 26 VDC electrical connection (EC axial fans „Power“)<br />

PWM<br />

Speed setting<br />

PWM 5 Hz - 100 kHz<br />

100 % PWM -> n=max<br />

15 % PWM -> n=min<br />

0 % PWM -> Standby<br />

Notes on various control possibilities and their applications<br />

12 V<br />

1 k<br />

Speed setting with<br />

potentiometer<br />

10 k<br />

Diagnostic output<br />

Operation:<br />

output level low (U = 0 V)<br />

Rotor locked or overtemperature<br />

or overvoltage/undervoltage:<br />

output level high (U = UB - 2 V)<br />

Imax = 50 mA<br />

Collective fault signal possible<br />

Full speed<br />

Customer circuit<br />

+<br />

U<br />

-<br />

Speed setting<br />

0 V - 10 V<br />

10 V -> n=max<br />

1,5 V -> n=min<br />

0 V -> Standby<br />

1<br />

3<br />

2<br />

4<br />

(black)<br />

(yellow)<br />

(white)<br />

(brown)<br />

UB +26 VDC<br />

PWM/LIN<br />

0 V to 10 V<br />

Diagnostic output<br />

GND<br />

RE typ. 44 k<br />

0.05 k<br />

Connection Fan