Set Up Your <strong>MicroLogix</strong><br />

RSLinx:<br />

1. Open RSLinx.<br />

2. Go to the following screen:<br />

<strong>Communications</strong> -> Configure Drivers…<br />

3. Stop and delete all of your DF1 drivers.<br />

4. From the available drivers, select RS232 DF1 devices, "Add New…"<br />

5. Press the Auto-Configure button.<br />

6. Press OK.<br />

You now should have a link to your <strong>MicroLogix</strong>.<br />

RSLogix 500:<br />

1. Open RSLogix 500.<br />

2. Open the .RSS project you wish to use for your <strong>MicroLogix</strong>.<br />

3. Go to the following dialog:<br />

Comms -> Who Active Go Online<br />

4. Select the <strong>MicroLogix</strong> you wish to download to.<br />

5. Download your program.<br />

6. Go online.<br />

7. Leaving the <strong>MicroLogix</strong> in Remote Run Mode, close RSLogix 500.<br />

8. In RSLinx, go to the following location:<br />

<strong>Communications</strong> -> Configure Drivers…<br />

9. Stop the DF1 driver. This allows RSView Studio to communicate <strong>with</strong> the<br />

<strong>MicroLogix</strong> via its own, built in RSLinx Enterprise.<br />

Set Up Your <strong>PanelView</strong> <strong>Plus</strong><br />

<strong>PanelView</strong>:<br />

1. The <strong>PanelView</strong> <strong>Plus</strong> needs an IP address in the same subnet as the PC.<br />

To obtain your PC's IP address, go to the following location:<br />

Start -> Run<br />

2. Press OK.<br />

3. Type cmd and press OK.<br />

4. At the command prompt, type ipconfig and press ENTER.