7<br />

7-1 TROUBLE CRITERION OF MAIN PARTS<br />

MR-508M,508ML<br />

MR-560M,560ML<br />

Components/<br />

Part Name<br />

Compressor Compressor in<br />

Run capacitor<br />

Motor<br />

protector<br />

TROUBLESHOOTING<br />

Model DG77C14RAW5<br />

Rated input W 139/141 (220/240 V, 50 Hz)<br />

Starting current A 10/11 (220/240 V, 50 Hz)<br />

Running current A 0.66/0.65 (220/240 V, 50 Hz)<br />

Auxilialy<br />

wiring<br />

Connected<br />

Point<br />

Main<br />

wiring<br />

the machine<br />

chamber at the<br />

rear side of<br />

the frame<br />

In the control<br />

panel of the<br />

Measure the resistance with a tester. refrigerator<br />

compartment<br />

Compressor in<br />

the machine<br />

Model 5TM232NHBYY chamber at the<br />

Open<br />

Check Method and Criterion<br />

Measure the resistance with a tester.(Ambient temperature:Room temperature 15 o C ~ 25 o C)<br />

rear side of<br />

the frame<br />

PTC thermistor Compressor in<br />

- 11 -<br />

Normal<br />

120 + 5 o C<br />

Close 69 + 9 o C<br />

Normal abnormal(faulty)<br />

Opened (∞Ω ) Short-circuited(0Ω )<br />

Normal abnormal(faulty)<br />

Less then 1Ω Opened(∞Ω )<br />

Abnormal<br />

(faulty)<br />

Main wiring 11 Ω (Approx.) Opened (∞ Ω )<br />

or<br />

short-circuited<br />

Auxilliary wiring 13.1 Ω (Approx.)<br />

(0Ω)<br />

Rated input 400VAC<br />

Parts Mounted<br />

Position<br />

PTH7M330MD2<br />

Measure the resistance with a tester.<br />

the machine<br />

chamber at the<br />

rear side of<br />

(Ambient temperature:Room temperature 15 o C ~ 25 o 5<br />

6<br />

2<br />

3<br />

MODEL<br />

3<br />

2<br />

C) the frame<br />

6 5<br />

Normal<br />

33 Ω (Approx.)<br />

Abnormal<br />

Opened (∞Ω ) or short (0Ω)<br />

As PTC thermistor has been heated while refrigerator is running be sure<br />

to measure the resistance after the thermistor has got cool enough.