<strong>Three</strong>-<strong>phase</strong> synchronous <strong>motors</strong> DS 45-100..540V<br />
Thermal sensor<br />
On resolver use. the temperature sensor is connected via the encoder plug. For SinCos encoder use.<br />
connection is effected via the main connection.<br />
Widerstand/Resistance (Ohm)<br />
KTY84 - 130<br />
2000<br />
1800<br />
1600<br />
1400<br />
1200<br />
1000<br />
800<br />
600<br />
400<br />
200<br />
0<br />
-50 0 50 100 150 200<br />
Temperatur/Temperature (°C)<br />
The motor temperature is continuously monitored using the thermal sensor type KTY 84-130.<br />
The above shown resistance results when the sensor is supplied with a measuring current of 2 mA.<br />
Fan data<br />
Fan for type DSO 56 4656 ZW - 956 230V. 50/60Hz; 0.12A<br />
4606 ZW - 958 115V. 60 Hz<br />
Fan for type DSO/ 71 and DSO/LIO 100 148VK028172 230V. 50/60Hz; 0.2A<br />
148VK028272 115V. 50/60Hz; 0.3A<br />
Type of<br />
protection<br />
IP54<br />
Connection 6-pin connector<br />
Fan connection<br />
View to contact side of female connector<br />
Pin Signal<br />
<strong>Three</strong>-<strong>phase</strong> synchronous <strong>motors</strong> 45 - 100 02/05 Technical alterations reserved<br />
<strong>Baumüller</strong> Nürnberg GmbH 45<br />
1<br />
2<br />
Phase U<br />
Neutral N<br />
PE