<strong>TransCut</strong> vs. conventional devices<br />

Legend:<br />

+ Very good<br />

o Satisfactory<br />

- Unsatisfactory<br />

<strong>TransCut</strong> <strong>300</strong> Conventional air plasma cutting devices<br />

Internal supply External compressed air<br />

supply<br />

Integral compressed air<br />

supply<br />

(built-in compressor)<br />

Medium Liquid Air Air<br />

Consumption 6 ml/min 120 l/min 120 l/min (ambient air)<br />

Portability + - o<br />

Weight + + / - -<br />

Mains supply + + -<br />

Materials + + +<br />

- Cutting speed + + -<br />

- Cutting surfaces + - -<br />

- Dross formation o + +<br />

Service life of wearing o o o<br />

parts (cutting nozzle, cathode)<br />

Toxic emissions + - -<br />

The <strong>TransCut</strong> <strong>300</strong> plasma cutting system - <strong>Plasma</strong> cutting with liquid cutting medium<br />

© Fronius 02/2006