Technical Description<br />

10<br />

Accuracy enhancement<br />

To enhance accuracy further, <strong>TankRadar</strong> <strong>Rex</strong> has<br />

some built-in unique features:<br />

Temperature control<br />

<strong>TankRadar</strong> <strong>Rex</strong> gauges are designed to operate in<br />

all climates. The gauge is continuously controlling<br />

the temperature of the electronics and keeps it<br />

constant. This is one of the reasons for the high<br />

accuracy and the 65 years of mean time between<br />

failure (MTBF) for the gauge.<br />

Digital reference<br />

A radar gauge needs an internal reference to make<br />

the radar sweep absolutely linear. Each deviation<br />

from the linearity produces a corresponding<br />

inaccuracy. To achieve highest precision, <strong>Saab</strong><br />

<strong>TankRadar</strong> <strong>Rex</strong> uses a digital crystal oscillator. This<br />

gives the most stable reference that is available with<br />

today’s technology.<br />

Drip-off means no condensation<br />

If the antenna has an inclined polished PTFEsurface<br />

(Teflon ® ) where the microwaves are emitted,<br />

it will be less susceptible to condensed water or<br />

product. The drops of condensation will not coat<br />

the active part of the antenna. In this way the radar<br />

signal will be less weakened resulting in higher<br />

accuracy and better reliability.<br />

Measurement close to tank wall<br />

A standard manway (or flange) is normally 0.3-1 m<br />

(1-3 feet) from the tank wall. Both the <strong>Saab</strong> RTG<br />

3920 Horn Antenna Gauge and the RTG 3930<br />

Parabolic Antenna Gauge are specially designed to<br />

be mounted close to the wall.<br />

The RTG 3920 Horn Antenna Gauge radar signal is<br />

polarized so that the direct reflection from the<br />

liquid surface is the only detectable reflection. Any<br />

wall disturbance will be blanked out. The RTG 3930<br />

Parabolic Antenna has a narrow radar beam due to<br />

the large 20-inch antenna diameter resulting in a<br />

small and uncritical wall echo.<br />

Antenna design with no horizontal surfaces according to the American<br />

Petroleum Institute Standard (API ch. 3.1B).<br />

Tank<br />

wall<br />

Not<br />

accepted<br />

Tank<br />

wall<br />

Liquid Liquid<br />

Accepted<br />

Gauges emitting microwaves with circular polarization can be installed<br />

closer to the tank wall.