Technical Description<br />

24<br />

Data Acquisition Units<br />

The Data Acquisition Unit (DAU) is used together<br />

with an associated Radar Tank Gauge for local<br />

readout and for connection of temperature sensors,<br />

pressure transmitters, on/off switches etc when<br />

more inputs/outputs are required than is available<br />

in the RTG.<br />

There are two versions of the Data Acquisition Unit,<br />

the Slave DAU and the Independent DAU.<br />

Slave Data Acquisition Unit DAU 2100<br />

A Multiple Spot Thermometer (MST) with up to 14<br />

temperature elements can be connected to the Slave<br />

DAU. The unit is powered from, and communicates<br />

through the Radar Tank Gauge to which it is<br />

connected. The Slave DAU is intrinsically safe<br />

using zener barriers on the Transmitter Interface<br />

Card (TIC) in the Radar Tank Gauge.<br />

The weatherproof box houses a printed circuit<br />

board with a cable terminal for connection of the<br />

temperature sensors, as well as the power and<br />

communication cable. Cable inlet cable glands are<br />

located at the bottom of the box.<br />

0.23 m (9 in.)<br />

The Slave Data Acquisition Unit with<br />

Local Readout Display mounted at the<br />

foot of a tank.<br />

LCD display for<br />

local readout<br />

EEx ia II C T4<br />

Tamb = -40° to +65°C<br />

BASEEFAEx91C2069<br />

Umax:in = 28 VDC Wmax:in = 1.3 W<br />

Imas:in = 394 mADC<br />

Ceq = 0 Leq = 0<br />

Serial no:<br />

0.28 m (11 in.)<br />

Data Acquisition Unit Type DAU 2100<br />

Hazardous Location Class I Group C<br />

and D. T emperature Code T4.<br />

Intrinsically safe for use in connection<br />

with Radar Unit TH 2000- TH 2014.<br />

See control drawing 9150 057-901<br />

Warning: any substitution of components<br />

may impair intrinsic safety<br />

See service manual<br />

Ambient temperature -40° to +65°C<br />

UI:<br />

A division of <strong>Saab</strong> Marine Electronics AB<br />

For intrinsically safe circuits only<br />

Listed 9390<br />

MADE IN SWEDEN<br />

Cable glands (not for US market)<br />

DAU 2100 Slave Data Acquisition Unit.