Saab TankRadar Rex
Saab TankRadar Rex
Saab TankRadar Rex
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Technical Description<br />
22<br />
Temperature measurement<br />
Product temperature is an important parameter for<br />
accurate custody transfer and inventory<br />
measurement in liquid bulk storage tanks. High<br />
quality Multiple Spot Thermometers (MST) can be<br />
included in the <strong>Rex</strong> system delivery as an essential<br />
part.<br />
The Multiple Spot Thermometer (MST) measures<br />
the temperature with a number of Pt 100 spot<br />
elements placed at different heights to provide a<br />
tank temperature profile and an average<br />
temperature. Only the elements that are fully<br />
immersed are used to determine the product<br />
temperature. The spot elements are placed in a<br />
flexible gas tight protection tube made from<br />
convoluted stainless steel. A flange can be attached<br />
to a top fitting and the tube can be anchored to the<br />
bottom.<br />
Multispot<br />
Thermometer<br />
RTG<br />
Anchor weight or alternatively<br />
a loop with steel wire pulled<br />
through and to top of tank.<br />
Up to 6 temperature elements can be connected directly to<br />
the r adar gauge.<br />
API chapter 7 recommends minimum one element<br />
per 10 feet (3 m) tank height for custody transfer<br />
applications.<br />
The Multiple Spot Thermometer is easy to install,<br />
even if the tank is in service. In pressurized tanks<br />
the MST can be installed in a closed thermowell so<br />
that it can be removed for service or inspection<br />
while the tank is in operation. For LPG tanks single<br />
spot temperatures sensors in thermowells are used.<br />
Temperature sensors can be connected in two ways<br />
to the RTG:<br />
Directly into the RTG with common return<br />
connection (up to six temperature elements)<br />
Via the DAU (up to 14 temperature<br />
elements)<br />
A water bottom sensor can be integrated in the<br />
MST, se page 34.<br />
DAU<br />
<strong>TankRadar</strong> L/2<br />
Ex<br />
DISPLAY<br />
MODE<br />
©<br />
Multispot<br />
Thermometer<br />
RTG<br />
Anchor weight or alternatively a<br />
loop with steel wire pulled<br />
through and to top of tank.<br />
When the number of temperature elements is above 6 they are<br />
connected via a Data Acquisition Unit. Maximum 14 temper ature<br />
elements can be connected.