Technical Description<br />
30<br />
Field Bus Modem, FBM 2171<br />
The Field Bus Modem (FBM) converts the signal<br />
from RS-232 to the TRL/2 Bus. It is used to connect<br />
a PC with the TankMaster HMI software to the<br />
TRL/2 Bus. The Field Bus Modem is delivered with<br />
the cable for connection to the PC. The Field Bus<br />
Modem has its own power supply through an AC/<br />
DC converter.<br />
FBM 2170 Field Bus Modem.<br />
mm (inch)<br />
Field Bus Modem<br />
Typ FBM 2170<br />
RS-232<br />
TRL/2 Bus<br />
1 2 3 4<br />
A division of <strong>Saab</strong> Marine Electronics AB<br />
MADE IN SWEDEN<br />
Connection<br />
to PC<br />
DC<br />
connector<br />
120 (4.7)<br />
Connection to Field bus<br />
Technical Data for FBM 2171<br />
Explosion Explosion protection: protection: None<br />
Power er er suppl suppl supply: suppl suppl y: From AC/DC converter supplied<br />
by <strong>Saab</strong> Rosemount Tank Control<br />
(6-15 V, 10 mA).<br />
Cab Cable Cab Cab le to to PC: PC:<br />
3 m (10 ft) included in deliv ery.<br />
Field Field b bbus<br />
b us o oover<br />
o er<br />
voltage oltage oltage protection: protection: Galvanic insulation, transient protection,<br />
suppressor s and fuses.