Technical Description<br />

14<br />

Technical Data for the Transmitter Head<br />

Instr Instrument Instr ument accur accuracy: accur accuracy:<br />

acy: ±0.5 mm ± (5/256 in.) [The instr ument accuracy is given as a 2σ value.<br />

This means that approximately 97% of the measured values are within the 0.5 mm tolerance.]<br />

Maxim Maximum Maxim um instr instr instrument instr ument deviation: deviation: ±0.8 mm (1/32 in.)<br />

Ambient Ambient oper operating oper ating temper temper temperature:<br />

temper ature: -40 °C to +70 °C (-40 °F to +158 °F)<br />

Hazardous Hazardous locations locations cer certif cer tif tifications: tif ications: EEx d[ia] IIB T6 (EN50014, EN50018 and EN50020 Europe) and Class 1, Div I,<br />

Groups C and D (UL1203, UL913 USA).<br />

See also the list on page 43 “Approvals for Installation in Hazardous Areas.”<br />

Ingress Ingress protection: protection: protection:<br />

IP 66 & 67<br />

Housing Housing Housing Mater Material: Mater ial: Anodized Aluminium<br />

Power er Suppl Supply: Suppl y: 100-240 VAC, 50-60 Hz, average 15 W (max. 80 W at gauge power up in temperatures<br />

below freezing point)<br />

34-70 VAC (option)<br />

48-99 VDC (option)<br />

Analog Analog Analog outputs: outputs:<br />

One output 4-20 mA passive or active (non-intrinsically safe)<br />

Analog Analog inputs: inputs:<br />

alt 1) One or two 4-20 mA<br />

alt 2) One 4-20 mA input plus one digital HART input. (The RTG is HART master.<br />

Each RTG can have maximum 3 HART slaves).<br />

Rela Rela Relay Rela y outputs: outputs:<br />

Max 2 relays, only 1 output available if analog outputs are included. See also under<br />

“Field bus (options)” and “Other vendor’s comm unication protocols” below.<br />

Field Field Field b bbus<br />

b us (standard): (standard):<br />

TRL/2 Bus (FSK, half duplex, two wires, galvanically isolated, 4800 Baud, Modbus based)<br />

Field Field b bbus<br />

b us (options): (options):<br />

1) Profibus® DP<br />

2) Tiway® (Only one relay available, analog out not available)<br />

Other Other vv<br />

vendor’ v vendor’<br />

endor’ endor’s endor’<br />

1) Enraf® (Requires special Field Bus Modem EBM<br />

comm communication comm communication<br />

unication protocols: protocols:<br />

2) Varec® (Only one relay available, analog output not available)<br />

3) L&J® (Only one relay available, analog output not available)<br />

4) Whessoe (Only one relay available, analog output not available)<br />

5) GPE® (Only one relay available, analog output not available)<br />

Temper emper emperature emper ature inputs: inputs:<br />

Up to 6 Pt 100 Resistance Temperature Detector (RTD) inputs with common return or<br />

3 RTD inputs with individual wiring, directly in TH.<br />

Up to 14 RTD inputs via separate Data Acquisition Unit, see page 24<br />

Field Field data data displa displa display: displa y: In separate DAU (page24) or RDU (page 27).