30.01.2013 Views

Cables for Installations and Industry - Draka

Cables for Installations and Industry - Draka

Cables for Installations and Industry - Draka

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CONTENTS


INSTALLATION CABLES<br />

– General in<strong>for</strong>mation about cables . . . . . . . . . . . . 3<br />

– Electrical properties. . . . . . . . . . . . . . . . . . . . 4<br />

– Identification of insulated conductors . . . . . . . . . . 5<br />

– Notes <strong>and</strong> symbols . . . . . . . . . . . . . . . . . . . . 6<br />

INSTALLATION CABLES<br />

– ML H07V-U . . . . . . . . . . . . . . . . . . . . . . . 7<br />

– MK 90 H07V2-R . . . . . . . . . . . . . . . . . . . . . 8<br />

MKEM 90 H07V2-K . . . . . . . . . . . . . . . . . . . 10<br />

– MMJ . . . . . . . . . . . . . . . . . . . . . . 12<br />

– MPLM . . . . . . . . . . . . . . . . . . . . . . 14<br />

– MKEMP . . . . . . . . . . . . . . . . . . . . . . 15<br />

– MJAM . . . . . . . . . . . . . . . . . . . . . . 16<br />

– MJAM ARM . . . . . . . . . . . . . . . . . . . . . . 18<br />

POWER CABLES 0,6/1 kV<br />

– MCMK . . . . . . . . . . . . . . . . . . . . . . 20<br />

– MCMK . . . . . . . . . . . . . . . . . . . . . . 22<br />

– AMCMK . . . . . . . . . . . . . . . . . . . . . . 24<br />

– MCCMK . . . . . . . . . . . . . . . . . . . . . . 26<br />

CONTROL CABLES<br />

– MMO . . . . . . . . . . . . . . . . . . . . . . 29<br />

– MCMO . . . . . . . . . . . . . . . . . . . . . . 30<br />

JUMPER WIRES<br />

– MKJE 90 H05V2-U, MKJ 90 H05V2-K,<br />

– MKJT 90 H05V2-K . . . . . . . . . . . . . . . . . . . 32<br />

– MKEMT 90 H07V2-K . . . . . . . . . . . . . . . . . . 35<br />

– MVJ 8 kV . . . . . . . . . . . . . . . . . . . . . . 36<br />

FLEXIBLE CORDS<br />

– MST H03VH-H . . . . . . . . . . . . . . . . . . . . . . 37<br />

– MSO H03VVH2-F . . . . . . . . . . . . . . . . . . . . 38<br />

– MSOY H03VV-F . . . . . . . . . . . . . . . . . . . . . 39<br />

– MSK H05VV-F . . . . . . . . . . . . . . . . . . . . . . 40<br />

INSTRUMENTATION CABLES<br />

– General:<br />

– Data transmission cables. . . . . . . . . . . . . . . . 42<br />

– Electrical properties. . . . . . . . . . . . . . . . . . . 42<br />

– Selection of the cable type . . . . . . . . . . . . . . . 43<br />

– Industrial networks . . . . . . . . . . . . . . . . . . . 44<br />

– Symmetrical halogen-free instrumentation cables . . . 44<br />

– Optical fibre cables in industry . . . . . . . . . . . . . 45<br />

INSTRUMENTATION CABLES<br />

– JAMAK . . . . . . . . . . . . . . . . . . . . . . 46<br />

– JAMAK ARM . . . . . . . . . . . . . . . . . . . . . . 47<br />

– JAMAK-C . . . . . . . . . . . . . . . . . . . . . . 48<br />

– NOMAK . . . . . . . . . . . . . . . . . . . . . . 50<br />

– NOMAK-E . . . . . . . . . . . . . . . . . . . . . . 51<br />

– FKAR-PG . . . . . . . . . . . . . . . . . . . . . . 52<br />

– KLAM . . . . . . . . . . . . . . . . . . . . . . 53<br />

– RD- . . . . . . . . . . . . . . . . . . . . . . 54<br />

– RD-Y(St)Y . . . . . . . . . . . . . . . . . . . . . . 55<br />

– JAMAK & JAMAK ARM JOINTIG . . . . . . . . . . . 56<br />

2<br />

CONTENTS<br />

SIGNAL CABLES<br />

– LON CABLING<br />

– Distributed data system of building technology . . . . . 57<br />

– LONAK 2 x 1,3 <strong>and</strong> LONAK ARM 2 x 1,3 . . . . . . . 58<br />

– LONAK 2 x 2 x 0,8 <strong>and</strong> LONAK 2 x 2 x 0,65. . . . . . 59<br />

– KLM . . . . . . . . . . . . . . . . . . . . . . 60<br />

– KLMA . . . . . . . . . . . . . . . . . . . . . . 61<br />

– MMSA . . . . . . . . . . . . . . . . . . . . . . 62<br />

– MMVDMA (MMPMA) . . . . . . . . . . . . . . . . . . 63<br />

DATA CABLES<br />

– Generic cabling systems<br />

– General . . . . . . . . . . . . . . . . . . . . . . 64<br />

– St<strong>and</strong>ards . . . . . . . . . . . . . . . . . . . . . . 64<br />

– Screening . . . . . . . . . . . . . . . . . . . . . . 64<br />

– Application <strong>and</strong> transmission classes . . . . . . . . . 64<br />

– Recommendations . . . . . . . . . . . . . . . . . . . 64<br />

– Data transmission cables. . . . . . . . . . . . . . . . 64<br />

– Generic cabling construction . . . . . . . . . . . . . . 65<br />

– Atm . . . . . . . . . . . . . . . . . . . . . . 65<br />

– Meaning of the symbols . . . . . . . . . . . . . . . . 65<br />

– Generic cabling cable type . . . . . . . . . . . . . . . 66<br />

– The colour system of the conductors. . . . . . . . . . 66<br />

– Compliance statement . . . . . . . . . . . . . . . . . 67<br />

– UC 300 S 24 4P/ UC 300 DS 24 2 x 4P . . . . . . . . 68<br />

– UC 300 24 4P/ UC 300 D 24 2 x 4P . . . . . . . . . . 70<br />

– UC 400 S 24 4P/ UC 400 DS 24 4P . . . . . . . . . . 72<br />

– UC 400 24 4P/ UC 400 D 24 2 x 4P . . . . . . . . . . 74<br />

– UC 600 SS 23/ 1 4P FRNC <strong>and</strong><br />

UC 1200 SS 22 4P FRNC. . . . . . . . . . . . . . . . 76<br />

– SUPERCAT . . . . . . . . . . . . . . . . . . . . . . 78<br />

FIBRE OPTIC CABLES<br />

FIBRE OPTIC ACCESSORIES<br />

– Fibre optic cables in premises data networks . . . . . . 80<br />

– General<br />

– Type coding of optical fibre cables . . . . . . . . . . . 81<br />

– Colour coding system of optical fibre cables. . . . . . 81<br />

– Optical fiber types . . . . . . . . . . . . . . . . . . . 81<br />

– Different constructions of optical fibre cables . . . . . 82<br />

– Optical fibre cables of NK <strong>Cables</strong> <strong>for</strong> different<br />

applications . . . . . . . . . . . . . . . . . . . . . . 82<br />

– Fymsu-term . . . . . . . . . . . . . . . . . . . . . . 83<br />

– Connectorised riser cables . . . . . . . . . . . . . . . 83<br />

– Distribution panels <strong>and</strong> cabinets . . . . . . . . . . . . 83<br />

– Data <strong>and</strong> instrumentation cable<br />

DATAJAMAK . . . . . . . . . . . . . . . . . . . . . . 84<br />

– Wiring <strong>and</strong> installation cables<br />

KLVMAAM, KLVMAM . . . . . . . . . . . . . . . . . . 86<br />

CATV/ RG CABLES<br />

– TELLU 13 . . . . . . . . . . . . . . . . . . . . . . 87<br />

– RG 58, (50 Ω), RG 59, (75 Ω) . . . . . . . . . . . . . 88<br />

– RG 213, RG 214, RG 223 (50 Ω) . . . . . . . . . . . . 89<br />

CABLE DRUMS<br />

– Maximum length of cable per drum, in meters . . . . . . 90<br />

– Dimensions <strong>and</strong> weights . . . . . . . . . . . . . . . . . 91


GE NE RAL IN FOR MA TI ON ABOUT CAB LES<br />

CATA LOGUE IN FOR MA TION<br />

The di men sions <strong>and</strong> weights are rounded nomi nal<br />

val ues.<br />

The let ters “D” <strong>and</strong> “A” ap pear ing in the prod uct<br />

speci fi ca tions in di cate:<br />

D = nomi nal over all di ame ter<br />

A = ca ble’s to tal cop per cross- section<br />

Bold print ing in di cates an item nor mally kept in stock<br />

AP PLI CA TION<br />

The har moni za tion docu ment HD 516 (Guide to use of<br />

low- voltage har mo nized ca bles) pro vides a guide to<br />

the pro posed safe use of har mo nized elec tric ca bles<br />

ac cord ing to HD 21.<br />

Ca bles should be se lected so that they are suit able <strong>for</strong><br />

the op er at ing con di tions.<br />

Ex am ples of op er at ing con di tions are:<br />

- volt age<br />

- over cur rent<br />

- pro tec tive meas ures<br />

- group ing of ca bles<br />

- method of in stal la tion<br />

- ac ces si bil ity<br />

Ca bles should be se lected so that they are suit able <strong>for</strong> any<br />

ex ter nal in flu ences which may ex ist.<br />

Ex am ples of ex ter nal in flu ences are:<br />

- am bi ent tem pera ture; mini mum <strong>and</strong> maxi mum<br />

- pre cence of rain, steam or ac cu mu la tion of wa ter<br />

- pre cense of cor ro sive, chemi cal or pol lut ing<br />

sub stances<br />

- me chani cal stresses (im pact, ten sion, com pres sion,<br />

sharp edges)<br />

- fauna (such as ro dents)<br />

- flora (such as mould)<br />

- ra dia tion (such as sun light)<br />

LI NYL<br />

Plastic- insulated con duc tors, ML, MK, MKEM <strong>and</strong><br />

plastic- sheated ca bles MMJ as well as plastic- sheated<br />

con trol ca bles MMO are coated with the Li nyl plas tic<br />

com pound. The Li nyl con pound makes the ca ble very slick<br />

<strong>and</strong> nearly fric tion less, <strong>and</strong> thus re quires only<br />

one- fifth of the pull ing <strong>for</strong>ce of an or di nary ca ble when<br />

drawn in ducts. As a re sult of this “fric tion less ness”,<br />

it is no longer nec es sary to use lu bri cants, which can be<br />

det ri men tal to plas tics. In stal la tion is eas ier, faster, lighter<br />

<strong>and</strong> con sid era bly more eco nomi cal <strong>and</strong> re li able.<br />

IN STAL LA TION OF THE CA BLE ON<br />

THE DRUM<br />

In stal la tion of a ca ble onto ca ble drum as well as<br />

wind ing to an other drum must be done in the man ner<br />

de picted be low.<br />

CE SYM BOL<br />

The CE sym bol on ca ble pack ages in di cates<br />

com pli ance with the EU’s low- voltage di rec tive.<br />

STAN DARDS<br />

The ca bles in the cata logue are manu fac tured<br />

ac cord ing to valid Fin nish SFS stan dards or<br />

in ter na tional CENE LEC stan dards.<br />

The in de pend ent <strong>and</strong> con trolled qual ity la bels,<br />

the sym bol <strong>and</strong> the pan- European sym bol,<br />

in di cate that the ca bles have been tested <strong>and</strong> cer ti fied.<br />

ISO 9001 QUAL ITY SYS TEM<br />

The Qual ity Man age ment Sys tem of <strong>Draka</strong> NK Ca bles Ltd<br />

has been ap proved by Lloyd’s Reg is ter Qual ity As sur ance<br />

Ltd to ISO 9001 <strong>and</strong> 14001:1994 Qual ity Man age ment<br />

Sys tem Stan dard.<br />

3


4<br />

RATED VOLT AGE<br />

The rated volt age of ca bles is marked Uo/U, where:<br />

- U o = rated volt age be tween the con duc tor <strong>and</strong> earth<br />

or me tal lic screen<br />

- U = rated volt age be tween con duc tors.<br />

DI RECT CUR RENT RE SIS TANCE OF<br />

CON DUC TORS<br />

The cata logue lists <strong>for</strong> each ca ble, the maxi mum di rect<br />

cur rent re sis tance val ues <strong>for</strong> the con duc tor at<br />

a tem pera ture of +20 °C, per mit ted by the con struc tion<br />

stan dard.The cur rent in a con duc tor heats up<br />

the con duc tor. The rise in tem pera ture in creases<br />

the con duc tor’s re sis tance. The fol low ing ta ble shows<br />

some pre- calculated cor rec tion fac tors <strong>for</strong> the di rect<br />

cur rent re sis tance of cop per con duc tor:<br />

Conductor temperature °C Correction factor<br />

20<br />

40<br />

60<br />

70<br />

80<br />

90<br />

ELECT RI CAL PRO PER TIES<br />

1,0<br />

1,079<br />

1,157<br />

1,196<br />

1,236<br />

1,275<br />

CA BLES CUR RENT CAR RY ING<br />

CA PAC ITY<br />

Cur rent car ry ing ca paci ties of in stal la tion ca bles are given<br />

in HD 384.5.523 (or IEC 364- 5- 523):<br />

Elec tri cal in stal la tion of build ings sec tion 523:<br />

Cur rent car ry ing ca paci ties.<br />

Cur rent rat ing ta bles are based on the re quire ments of<br />

the maxi mum per mis si ble con duc tor tem pera tures in<br />

con tinu ous use <strong>and</strong> as sumed in stal la tion con di tions.<br />

The cor rec tion fac tors must be used when the con di tions<br />

dif fer from the in stal la tion con di tions as sumed in<br />

the cur rent rat ing ta bles.<br />

Cur rent rat ings <strong>for</strong> flexi ble ca bles<br />

(PVC ca bles ac cord ing to HD 21)<br />

HD 516 Ta ble 7a<br />

Cross-section of<br />

conductors<br />

mm 2<br />

0,75<br />

1,0<br />

1,5<br />

2,5<br />

4<br />

Current rating<br />

2 cores load<br />

A<br />

6<br />

10<br />

16<br />

25<br />

32<br />

Current rating<br />

3 cores load<br />

A<br />

As sump tions <strong>for</strong> ta ble are:<br />

- Con duc tor tem pera ture in PVC- insulated ca bles<br />

+70 °C.<br />

- Am bi ent air tem pera ture +30 °C.<br />

Ta ble <strong>for</strong> con trol ca bles.<br />

6<br />

10<br />

16<br />

20<br />

25<br />

The maxi mum per mis si ble con tinu ous<br />

cur rent load in am peres <strong>for</strong> PVC- insulated con trol ca ble<br />

U o /U=450/750 V in stalled in open air.<br />

Number of<br />

conductors with<br />

load<br />

4<br />

7<br />

12<br />

19<br />

27<br />

37<br />

48<br />

Copper conductor cross-section<br />

mm 2<br />

0,75 1,5 2,5<br />

–<br />

8<br />

7<br />

6<br />

5<br />

4<br />

4<br />

As sump tions <strong>for</strong> ta ble are:<br />

- Con duc tor tem pera ture +70 °C<br />

- Am bi ent air tem pera ture +25 °C<br />

–<br />

13<br />

11<br />

9<br />

8<br />

7<br />

6<br />

20<br />

16<br />

13<br />

11<br />

10<br />

9<br />


IDEN TI FI CA TI ON OF IN SU LA TED<br />

CON DUC TORS<br />

PREVIOUS AND NEW STANDARD,<br />

HD 308 S2<br />

MMJ, MJAM <strong>and</strong> MPLM<br />

m<br />

e<br />

t<br />

s<br />

y<br />

s<br />

-<br />

N<br />

m<br />

e<br />

t<br />

s<br />

y<br />

-<br />

S<br />

Previous<br />

2-wires<br />

4-wires<br />

5-wires<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

MSK, MSO <strong>and</strong> MSOY<br />

m<br />

e<br />

t<br />

s<br />

y<br />

s<br />

-<br />

N<br />

Previous<br />

MCMK <strong>and</strong> MCCMK<br />

m<br />

e<br />

t<br />

s<br />

y<br />

-<br />

S<br />

Previous<br />

Previous<br />

Previous<br />

3-wires<br />

2-wires<br />

3-wires<br />

4-wires<br />

5-wires<br />

3-wires<br />

4-wires<br />

5-wires<br />

HD 308 S2<br />

New<br />

New<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

HD 308 S2<br />

New<br />

New<br />

HD 308 S2<br />

New<br />

AB BRE VIA TIONS OF COL OURS<br />

AP PEAR ING IN CATA LOGUE<br />

(on drum, reel or coil la bels)<br />

MU = BK Black<br />

SI = BU Blue<br />

KEVI = GNYE Green/yel low<br />

RU = BN Brown<br />

VA = WH White<br />

PU = RD Red<br />

KE = YE Yel low<br />

ORA = OG Or ange<br />

HA = GY Grey<br />

CON TROL CA BLES<br />

Con duc tors in con trol ca bles are of the same col our<br />

(black ) <strong>and</strong> con secu tively num bered start ing from<br />

the centre of the ca ble.<br />

SHEATH MARK INGS<br />

The fol low ing em bossed or col our mark ings are marked<br />

on the outer sheath of in stal la tion, power <strong>and</strong> con trol<br />

ca bles used in fixed in stal la tions<br />

- manu fac tur er’s code<br />

- type des ig na tion, number <strong>and</strong> cross- section of<br />

con duc tors, iden ti fi ca tion let ters of the in su la tion<br />

col ours, <strong>and</strong> rated volt age<br />

- manu fac tur er’s in ter nal code<br />

- con tinu ous me ter mark ing<br />

- SGS FIMKO cer ti fi ca tion mark<br />

Ex am ple:<br />

NK CABLES MMJ 5x2,5 mm 2 S 300/500 V 24AS45<br />

00001<br />

CER TI FI CA TIONS<br />

SGS FIMKO -ce rf ified<br />

HAR -marked<br />

Russian Certification St<strong>and</strong>ard<br />

5


6<br />

N<br />

SYM BOLS<br />

AP PLI CA TION<br />

MAXI MUM TEM PERA TURE<br />

LOW EST TEM PERA TURE<br />

BEND ING RA DIUS<br />

TEN SILE STRESS<br />

VOLT AGE<br />

STAN DARD<br />

CER TI FI CA TIONS<br />

IDEN TI FI CA TION OF CORES<br />

CON STRUC TION<br />

SELF- EXTINGUISHING IEC 332-1<br />

SELF-EXTINGUISHING IEC 332-3<br />

ELEC TRO MAG NETIC COM PATI BIL ITY<br />

HALO GEN FREE<br />

FIRE- RESISTANT IEC 331<br />

NOTE<br />

NOTES AND SYM BOLS<br />

See more info<br />

www.drakankc.fi all these<br />

cables you find in NK Club.<br />

EAN CODE<br />

The EAN number (Euro pean Ar ti cle Num ber) will be<br />

adopted in ad di tion to the na tional elec tri cal ar ti cle<br />

number. It is <strong>for</strong>med from the na tional elec tri cal ar ti cle<br />

number as fol lows:<br />

64 (= Fin l<strong>and</strong>’s coun try code)<br />

100 (= manu fac turer code ap plied <strong>for</strong> by<br />

Fin nish Elec tri cal Whole sal ers’ Fed era tion SSTL)<br />

04 067 22 (= SSTL’s elec tri cal number)<br />

2 (con trol number cal cu lated<br />

ac cord ing to the EAN regu la tion)<br />

Ex am ple. MMJ 3x1,5 S coil 64 100 04 067 22-2


1,5 mm 2<br />

AP PLI CA TION<br />

For fixed in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing in<br />

ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

– in con tinu ous use +70 °C<br />

– in short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

– dur ing in stal la tion 8xD<br />

– in a fi nal in stal la tion if bent only once 3xD<br />

INSTALLATION CABLES<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion: Ax50 N/mm²<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Cross-section of conductor<br />

<strong>and</strong> colour mm² 1,5 VA 1,5 RU 1,5 MU 1,5 SI 1,5 KEVI<br />

EAN code (SSTL code) 64 100+<br />

coil 04 008 00-3 04 008 02-7 04 008 03-4 04 008 07-2 04 008 08-9<br />

Nominal overall diameter mm 2,7 2,7 2,7 2,7 2,7<br />

Total weight kg/km 20 20 20 20 20<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 12,1 12,1 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length m 200 200 200 200 200<br />

2,5 mm 2<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 2,5 VA 2,5 RU 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+<br />

coil 04 008 20-1 04 008 22-5 04 008 23-2 04 008 27-0 04 008 28-7<br />

Nominal overall diameter mm 3,3 3,3 3,3 3,3 3,3<br />

Total weight kg/km 31 31 31 31 31<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 7,41 7,41 7,41 7,41 7,41<br />

St<strong>and</strong>ard delivery length m 200 200 200 200 200<br />

Coil = shrink-wrapped coil<br />

Plas tic- in su la ted con duc tor<br />

ML H07V-U<br />

So lid con duc tor<br />

N<br />

Self- extinguishing IEC 332-1<br />

In su la tion Lead- free Li nyl PVC,<br />

core iden ti fi ca tion by col ours<br />

7


IN STAL LA TION CA BLES<br />

8<br />

N<br />

AP PLI CA TION<br />

For per ma nent in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing<br />

in ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Plas tic- in su la ted con duc tor<br />

MK 90 H07V2-R<br />

Stran ded con duc tor<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed In su la tion Lead-free Li nyl PVC, core iden ti fi ca tion<br />

by col ours<br />

1,5 mm2 2,5 mm2<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 1,5 RU 1,5 MU 1,5 SI 1,5 KEVI 2,5 RU 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+<br />

coil 04 017 04-3 04 017 03-6 04 017 05-0 04 017 02-9 04 017 08-1 04 017 07-4 04 017 09-8 04 017 06-7<br />

Nominal overall diameter mm 3,0 3,0 3,0 3,0 3,7 3,7 3,7 3,7<br />

Total weight kg/km 22 22 22 22 35 35 35 35<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 12,1 12,1 12,1 12,1 7,41 7,41 7,41 7,41<br />

St<strong>and</strong>ard delivery length m 250 250 250 250 200 200 200 200<br />

Coil = shrink-wrapped coil<br />

Self- extinguishing IEC 332-1


Cross-section of conductor <strong>and</strong><br />

colour mm² 4 MU 4 SI 4 KEVI 6 RU 6 MU 6 SI 6 KEVI<br />

EAN code (SSTL code) 64 100+ 04 017 11-91 04 017 13-5 04 017 10-4 04 017 16-6 04 017 15-9 04 017 17-3 04 017 14-2<br />

Nominal overall diameter mm 4,2 4,2 4,2 4,8 4,8 4,8 4,8<br />

Total weight kg/km 52 52 52 70 70 70 70<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 4,61 4,61 4,61 3,08 3,08 3,08 3,08<br />

St<strong>and</strong>ard delivery length<br />

coil m 150 150 150 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 10 MU 10 SI 10 KEVI 16 MU 16 SI 16 KEVI<br />

EAN code (SSTL code) 64 100+ 04 017 19-5 04 017 20-3 04 017 18-0 04 017 22-7 04 017 23-4 04 017 21-0<br />

Nominal overall diameter mm 6,1 6,1 6,1 7,2 7,2 7,2<br />

Total weight kg/km 115 115 115 175 175 175<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 1,83 1,83 1,83 1,15 1,15 1,15<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 25 MU 25 SI 25 KEVI 35 MU 35 SI 35 KEVI<br />

EAN code (SSTL code) 64 100+ 04 022 14-6 04 022 15-3 04 022 16-0 04 522 22-6 04 522 23-3 04 522 27-1<br />

Nominal overall diameter mm 8,9 8,9 8,9 10,0 10,0 10,0<br />

Total weight kg/km 270 270 270 370 370 370<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,727 0,727 0,727 0,524 0,524 0,524<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100 100 100<br />

500/6C 500/6C 500/6C<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 50 MU 50 SI 50 KEVI 70 KEVI 95 KEVI 120 KEVI<br />

EAN code (SSTL code) 64 100+ 04 522 33-2 04 522 37-0 04 522 38-7 04 022 48-6 04 022 58-0 04 022 66-5<br />

Nominal overall diameter mm 11,7 11,7 11,7 13,4 16,0 18<br />

Total weight kg/km 510 510 510 710 1000 1200<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,387 0,387 0,387 0,268 0,193 0,153<br />

St<strong>and</strong>ard delivery length<br />

drum m 200/6C 200/6C 200/6C 200/6C 500/8E 800/11G<br />

Coil = shrink-wrapped coil<br />

Plas tic- in su la ted con duc tor<br />

MK90 H07V2-R<br />

Stran ded con duc tor<br />

INSTALLATION CABLES<br />

9


INSTALLATION CABLES<br />

10<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing in<br />

ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Plas tic- in su la ted con duc tor<br />

MKEM 90 H07V2-K<br />

Fle xib le con duc tor<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: – 25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed<br />

flexi ble<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Self- extinguishing IEC 332-1<br />

In su la tion Lead-free Li nyl PVC, core iden ti fi ca tion<br />

by col ours<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 1,5 RU 1,5 MU 1,5 SI 1,5 KEVI 2,5 RU 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 02-5 04 031 03-2 04 031 07-0 04 031 08-7 04 031 22-3 04 031 23-0 04 031 27-8 04 031 28-5<br />

Nominal overall diameter mm 3,0 3,0 3,0 3,0 3,6 3,6 3,6 3,6<br />

Total weight kg/km 21 21 21 21 32 32 32 32<br />

Direct current resistance of<br />

conductor at+20 °C max. Ω/km 13,3 13,3 13,3 13,3 7,98 7,98 7,98 7,98<br />

St<strong>and</strong>ard delivery length<br />

coil m 250 250 250 250 200 200 200 200


Plas tic- in su la ted con duc tor<br />

MKEM 90 H07V2-K<br />

Fle xib le con duc tor<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 4 MU 4 SI 4 KEVI 6 MU 6 SI 6 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 43-8 04 031 47-6 04 031 48-3 04 031 63-6 04 031 67-4 04 031 68-1<br />

Nominal overall diameter mm 4,1 4,1 4,1 5,0 5,0 5,0<br />

Total weight kg/km 45 45 45 70 70 70<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 4,95 4,95 4,95 3,30 3,30 3,30<br />

St<strong>and</strong>ard delivery length , coil m 100 100 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 10 MU 10 SI 10 KEVI 16 MU 16 SI 16 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 83-4 04 031 87-2 04 031 88-9 04 032 03-9 04 032 07-7 04 032 08-4<br />

Nominal overall diameter mm 6,5 6,5 6,5 7,6 7,6 7,6<br />

Total weight kg/km 115 115 115 170 170 170<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 1,91 1,91 1,91 1,21 1,21 1,21<br />

St<strong>and</strong>ard delivery length, coil m 100 100 100 100 100 100<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 25 MU 25 SI 25 KEVI 35 MU 35 SI 35 KEVI<br />

EAN code (SSTL code) 64 100+ 04 032 13-8 04 032 17-6 04 032 18-3 04 532 23-2 04 532 27-0 04 532 28-7<br />

Nominal overall diameter mm 9,4 9,4 9,4 11,0 11,0 11,0<br />

Total weight kg/km 270 270 270 370 370 370<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,780 0,780 0,780 0,554 0,554 0,554<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100 100 100<br />

INSTALLATION CABLES<br />

500/6C 500/6C 500/6C<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 50 MU 50 SI 50 KEVI 70 MU 70 SI 70 KEVI<br />

EAN code (SSTL code) 64 100+ 04 532 33-1 04 532 37-9 04 532 38-6 04 532 43-0 04 532 47-8 04 532 48-5<br />

Nominal overall diameter mm 13,0 13,0 13,0 13,0 15,0 15,0<br />

Total weight kg/km 520 520 520 730 730 730<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,386 0,386 0,386 0,272 0,272 0,272<br />

St<strong>and</strong>ard delivery length, drum m 200/6C 200/6C 200/6C 200/6C 200/6C 200/6C<br />

Cross-section of conductor <strong>and</strong><br />

colour mm² 95 MU 95 SI 120 MU 150 MU 240 MU<br />

EAN code (SSTL code) 64 100+ 04 032 53-4 04 032 57-2 04 032 63-3 04 032 73-2 04 032 93-0<br />

Nominal overall diameter mm 17,5 17,5 19 22 27<br />

Total weight kg/km 940 940 1200 1450 2400<br />

Direct current resistance of<br />

conductorat+20 °C max. Ω/km 0,206 0,206 0,161 0,129 0,0801<br />

St<strong>and</strong>ard delivery length, drum m 200/7E 200/7E 200/7E 200/7E 450/11G<br />

11


INSTALLATION CABLES<br />

12<br />

N<br />

AP PLI CA TION<br />

For fixed sur face or flush- mounted in stal la tions,<br />

in doors <strong>and</strong> out doors.<br />

- Suit able <strong>for</strong> in stal la tion in a slot cov ered with plas ter<br />

- Not <strong>for</strong> in stal la tion di rectly in ground nor di rectly in<br />

con crete with out pro tec tive duct ing.<br />

- Not <strong>for</strong> in stal la tions sub ject to elec tri cal in ter fer ence<br />

(see MCCMK <strong>and</strong> MJAM).<br />

- Di rect sun light may change col our of sheath<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per 1,5 <strong>and</strong> 2,5 mm², solid<br />

6...25 mm², str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by col ours<br />

Plas tic- sheat hed cab le<br />

MMJ<br />

RATED VOLT AGE<br />

U o /U = 300/500 V, 1,5 mm² <strong>and</strong> 2,5 mm²<br />

U o /U = 450/750 V, 6 mm² ... 25 mm²<br />

STAN DARD<br />

SFS 2091 <strong>and</strong> SFS 5524<br />

CORE IDEN TI FI CA TION<br />

WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5 S 3 x 2,5 S 3 x 6 S 3 x 10 S<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(reel) 64 100+<br />

(drum) 64 100+<br />

04 067 22-2<br />

04 567 72-2<br />

04 567 22-7<br />

04 067 23-9<br />

04 567 73-9<br />

04 567 23-4<br />

04 067 25-3<br />

–<br />

04 567 25-8<br />

–<br />

–<br />

04 067 26-0<br />

Nominal overall diameter mm 8,8 10,0 14,1 17,1<br />

Total weight kg/km 130 180 350 540<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

reel m<br />

drum m<br />

100<br />

300<br />

1000/K7<br />

2-wires<br />

3-wires<br />

4-wires<br />

5-wires<br />

100<br />

200<br />

1000/K7<br />

N-system<br />

Self- extinguishing IEC 332-1<br />

Fill ing Fill ing com pound<br />

Sheath White, lead free Li nyl PVC<br />

- marked by me ters<br />

50<br />

–<br />

500/K8<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

S-ystem<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

–<br />

–<br />

400/K8


WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 1,5 S 4 x 2,5 S 4 x 6 S 4 x 10 S 4 x 16 S<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(reel) 64 100+<br />

(drum) 64 100+<br />

04 067 32-1<br />

04 567 82-1<br />

04 567 32-6<br />

04 067 33-8<br />

–<br />

04 567 33-3<br />

–<br />

–<br />

04 567 35-7<br />

–<br />

–<br />

04 067 36-4<br />

–<br />

–<br />

04 567 37-1<br />

Nominal overall diameter mm 9,6 11,0 15,3 18,8 21,0<br />

Total weight kg/km 155 220 430 670 940<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83 1,15<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

reel m<br />

drum m<br />

100<br />

250<br />

1000/K7<br />

100<br />

–<br />

750/K7<br />

–<br />

–<br />

500/K8<br />

WITH PROTECTIVE CONDUCTOR<br />

–<br />

–<br />

400/K8<br />

–<br />

–<br />

250/K8<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 5 x 1,5 S 5 x 2,5 S 5 x 6 S 5 x 10 S 5 x 16 S 5 x 25 S<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(reel) 64 100+<br />

(drum) 64 100+<br />

04 067 42-0<br />

04 567 92-0<br />

04 567 42-5<br />

04 067 43-7<br />

04 567 93-7<br />

04 567 43-2<br />

–<br />

–<br />

04 567 45-6<br />

–<br />

–<br />

04 067 46-8<br />

–<br />

–<br />

04 067 47-5<br />

–<br />

–<br />

04 067 48-2<br />

Nominal overall diameter mm 10,3 11,8 16,6 21,0 23,0 31,0<br />

Total weight kg/km 180 260 510 830 1200 1900<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83 1,15 0,727<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

reel m<br />

drum m<br />

100<br />

200<br />

1000/K7<br />

50<br />

150<br />

750/K8<br />

–<br />

–<br />

500/K8<br />

–<br />

–<br />

250/K8<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

–<br />

–<br />

250/K9<br />

–<br />

–<br />

250/K11<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 2 x 1,5 N 2 x 2,5 N 3 x 1,5 N 4 x 1,5 N 5 x 1,5 N<br />

EAN code (SSTL code)<br />

(coil) 64 100+<br />

(drum) 64 100+<br />

04 064 12-2<br />

04 564-12-7<br />

04 064 13-9<br />

04 564 13-4<br />

04 064 22-1<br />

04 564 22-6<br />

04 064 32-0<br />

04 564 32-5<br />

04 064 42-9<br />

04 564 42-4<br />

Nominal overall diameter mm 8,4 9,6 8,8 9,6 10,3<br />

Total weight kg/km 105 150 130 155 180<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100<br />

1000/K7<br />

Plas tic- sheat hed cab le<br />

MMJ<br />

100<br />

1000/K7<br />

100<br />

1000/K7<br />

INSTALLATION CABLES<br />

100<br />

1000/K7<br />

100<br />

1000/K7<br />

13


INSTALLATION CABLES<br />

14<br />

N<br />

AP PLI CA TION<br />

For fixed sur face in stal la tion in doors.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

In su la tion PVC, core iden ti fi ca tion by col ours<br />

Fill ing Fill ing com pound<br />

Surfa ce instal la ti on cab le NOT KA<br />

MPLM<br />

WITH PROTECTIVE CONDUCTOR<br />

RATED VOLT AGE<br />

U o /U = 300/500 V<br />

STAN DARD<br />

SS 424 02 19-2<br />

CORE IDEN TI FI CA TION<br />

Self- extinguishing IEC 332-1<br />

Drain wire Tinned copper wires<br />

Metal sheath Lon gi tu di nal alu min ium tape<br />

Sheath White PVC<br />

WITHOUT<br />

PROTECTIVE<br />

CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5/1 S 3 x 2,5/1 S 4 x 1,5/1 S 5 x 1,5/1 S 2 x 1,5/1 N 3 x 1,5/1 N<br />

EAN code (SSTL code) 64 100+ 04 055 26-7 04 055 27-4 04 055 36-6 04 055 46-5 04 055 11-3 04 055 23-6<br />

Nominal overall diameter mm 8,5 9,8 9,2 10,0 8,0 8,5<br />

Total weight kg/km 130 185 165 185 110 130<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 12,1 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

coil m 50 50 50 50 50 50<br />

2-wires<br />

3-wires<br />

N-system S-ystem<br />

3-wires<br />

4-wires<br />

5-wires


N<br />

AP PLI CA TION<br />

For fixed in stal la tion mainly as a con nect ing ca ble <strong>for</strong><br />

post mounted lu mi naires.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -25 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing ca ble pull ing 10xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

Maxi mum per mis si ble ten sile stress: Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

In su la tion PVC<br />

Cab le <strong>for</strong> lamp- posts<br />

MKEMP<br />

Fle xib le con duc tor<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARDI<br />

SFS 5523 <strong>and</strong> SFS 2091<br />

Self- extinguishing IEC 332-1<br />

Sheath PVC<br />

INSTALLATION CABLES<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm² 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+ 04 034 03-3 04 034 07-1 04 034 08-8<br />

Nominal overall diameter mm 8,0 8,0 8,0<br />

Total weight kg/km 82 82 82<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 7,98 7,98 7,98<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100<br />

15


INSTALLATION CABLES<br />

16<br />

N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits of<br />

elec tri cal equip ment <strong>and</strong> feeder ca ble <strong>for</strong> elec tronic<br />

equip ment <strong>for</strong> fixed sur face <strong>and</strong> flush- mounted<br />

in stal la tions, in doors <strong>and</strong> out doors.<br />

The lapped Al- PE lami nate <strong>for</strong>ms a good screen against<br />

elec tri cal in ter fer ence <strong>and</strong> the lami nate<br />

com bined with the PE- sheath <strong>for</strong>ms a good mois ture<br />

bar rier.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Me tal sheat hed cab le<br />

MJAM<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SS 4240219<br />

CORE IDEN TI FI CA TION<br />

S-ystem<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

Control cables 7...19 wires; numbers<br />

Self- extinguishing IEC 332-1<br />

Elec tro mag netic com pati bil ity


CON STRUC TION<br />

Con duc tor An nealed cop per:<br />

1,5 <strong>and</strong> 2,5 mm 2 solid<br />

6 <strong>and</strong> 10 mm 2 str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by<br />

col ours <strong>and</strong>/or num bers<br />

WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5 S 3 x 2,5 S 3 x 6 S<br />

EAN code (SSTL code) 64 100+ 04 130 01-8 04 130 02-5 04 130 04-9<br />

Nominal overall diameter mm 10 11,5 15<br />

Total weight kg/km 145 200 360<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/K6 500/K7 250/K8<br />

WITH PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 5 x 1,5 S 5 x 2,5 S 5 x 6 S<br />

EAN code (SSTL code) 64 100+ 04 130 07-0 04 130 08-7 04 130 10-0<br />

Nominal overall diameter mm 11,5 13 18<br />

Total weight kg/km 200 280 520<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/K7 500/K7 250/K8<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 12 x 1,5 19 x 1,5<br />

EAN code (SSTL code) 64 100+ 04 130 15-5 04 130 18-6 04 130 20-9<br />

Nominal overall diameter mm 12,5 16 19<br />

Total weight kg/km 250 380 550<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

drum m 400/K7 400/K8 400/K9<br />

Electrical properties<br />

Capacitance between<br />

two adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of<br />

one conductor<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

130...160<br />

210...280<br />

Me tal sheat hed cab le<br />

MJAM<br />

130...160<br />

210...280<br />

INSTALLATION CABLES<br />

Fill ing Fill ing com pound<br />

Me tal lic screen AI- PE lami nate <strong>and</strong> drain wire,<br />

1,0 mm²<br />

Sheath White PE/lead free PVC<br />

- marked by me ters<br />

130...160<br />

210...280<br />

17


INSTALLATION CABLES<br />

18<br />

N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits of<br />

elec tri cal equip ment <strong>and</strong> feeder ca ble <strong>for</strong> elec tronic<br />

equip ment <strong>for</strong> fixed sur face <strong>and</strong> flush- mounted<br />

in stal la tions, in doors <strong>and</strong> out doors.<br />

The ar mour ing <strong>and</strong> the lapped AI- PE lami nate <strong>for</strong>ms<br />

a good me chani cal, elec tri cal <strong>and</strong> elec tro mag neti cal<br />

shield <strong>for</strong> the ca ble, <strong>and</strong> the lami nate com bined with the<br />

PE- sheath <strong>for</strong>ms a good mois ture bar rier.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Ar mou red me tal- sheat hed cab le<br />

MJAMARM<br />

3-wires<br />

4-wires<br />

4-wires*<br />

5-wires<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5247 <strong>and</strong> SS 4240219<br />

CORE IDEN TI FI CA TION<br />

S-ystem<br />

*Only <strong>for</strong> 1,5 <strong>and</strong> 2,5 mm 2 cables<br />

Control cables 7...19 wires; numbers<br />

Self- extinguishing IEC 332-1<br />

Elec tro mag netic com pati bil ity


CON STRUC TION<br />

Con duc tor An nealed cop per:<br />

1,5 <strong>and</strong> 2,5 mm 2 solid<br />

6 <strong>and</strong> 10 mm 2 str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by<br />

col ours <strong>and</strong>/or num bers<br />

Fill ing Fill ing com pound<br />

WITH PROTECTIVE CONDUCTORS<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5 S 3 x 2,5 S<br />

EAN code (SSTL code) 64 100+ 04 130 51-3 04 130 52-0<br />

Nominal overall diameter mm 13 15<br />

Total weight kg/km 290 360<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41<br />

St<strong>and</strong>ard delivery length<br />

drum m 300/6C 300/7E<br />

WITH PROTECTIVE CONDUCTORS<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 5 x 1,5 S 5 x 2,5 S<br />

EAN code (SSTL code) 64 100+ 04 130 57-5 04 130 58-2<br />

Nominal overall diameter mm 15 17<br />

Total weight kg/km 360 460<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41<br />

St<strong>and</strong>ard delivery length<br />

drum m 300/7E 300/8E<br />

WITHOUT PROTECTIVE CONDUCTORS<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 7 x 2,5 12 x 1,5 19 x 1,5<br />

EAN code (SSTL code) 64 100+ 04 130 65-0 04 130 66-7 04 130 68-1 04 130 70-4<br />

Nominal overall diameter mm 16 18 20 23<br />

Total weight kg/km 430 560 610 820<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 12,1 12,1<br />

St<strong>and</strong>ard delivery length<br />

drum m 400/8E 400/9E 400/11G 400/11G<br />

Electrical properties<br />

Capacitance between<br />

two adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of<br />

one conductor<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Ar mou red me tal- sheat hed cab le<br />

MJAMARM<br />

130...160<br />

210...280<br />

130...160<br />

220...290<br />

INSTALLATION CABLES<br />

Me tal lic screen AI- PE lami nate <strong>and</strong><br />

drain wire, 1,0 mm²<br />

Sheath White PE/lead free PVC<br />

Ar mour ing Two zinc- coated steel tapes<br />

Sheath Black lead free PVC<br />

- marked by me ters<br />

130...160<br />

210...280<br />

130...160<br />

210...280<br />

19


POWER INSTALLATION CABLES<br />

20<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in doors, out doors <strong>and</strong><br />

un der ground as well as in build ing struc tures,<br />

e.g. di rectly in con crete.<br />

Not <strong>for</strong> in stal la tions sub ject to se vere elec tri cal<br />

in ter fer ence (see MCCMK <strong>and</strong> MJAM).<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Elec tro mag netic com pati bil ity<br />

MCMK<br />

2-wires<br />

3-wires<br />

4-wires<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV U m = 1,2 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1<br />

CORE IDEN TI FI CA TION<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor An nealed cop per<br />

1,5 ... 6 mm², solid<br />

10 <strong>and</strong> 16 mm² , str<strong>and</strong>ed<br />

In su la tion Lead free PVC, core iden ti fi ca tion by<br />

col ours <strong>and</strong>/or num bers<br />

Fill ing Fill ing com pound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 2 x 1,5/1,5 2 x 1,5/1,5 2 x 2,5/2,5 2 x 2,5/2,5 2 x 6/6 2 x 10/10 RM<br />

EAN code (SSTL code) 64 100+ 06 021 12-3 06 021 22-2 06 021 13-0 06 021 23-9 06 021 25-3 06 021 26-0<br />

Nominal overall diameter mm 11,5 11,5 12,3 12,3 16,2 19,0<br />

Total weight kg/km 165 165 200 200 370 550<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 12,1 7,41 7,41 3,08 1,83<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100<br />

1000/8E<br />

100<br />

1000/K9 500/K8 500/K9<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 1,5/1,5 3 x 2,5/2,5 3 x 6/6 3 x 10/10 RM 3 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 021 52-9 06 021 53-6 06 021 55-0 06 021 56-7 06 021 57-4<br />

Nominal overall diameter mm 12 13 17 20,0 23,0<br />

Total weight kg/km 190 240 450 680 970<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 7,41 3,08 1,83 1,15<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/K8 1000/K9 500/K8 500/K9 500/K11<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 1,5/1,5 4 x 1,5/1,5 4 x 2,5/2,5 4 x 2,5/2,5 4 x 6/6 4 x 10/10 RM 4 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 021 92-5 06 021 72-7 06 021 93-2 06 021 43-7 06 021 45-1 06 021 76-5 06 021 47-5<br />

Nominal overall diameter mm 13 13 14 14 18,5 22 25<br />

Total weight kg/km 210 210 270 270 520 790 1150<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 12,1 12,1 7,41 7,41 3,08 1,83 1,15<br />

St<strong>and</strong>ard delivery length<br />

coil m<br />

drum m<br />

100<br />

MCMK<br />

1000/K9<br />

100<br />

POWER INSTALLATION CABLES<br />

Con cen tric<br />

con duc tor A layer of cop per wires <strong>and</strong> an open<br />

he lix of par al lel cop per wires<br />

Sheath Black, lead free PVC<br />

- marked by me ters<br />

1000/K9 500/K9 500/K11 500/K11<br />

21


POWER INSTALLATION CABLES<br />

22<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in doors, out doors <strong>and</strong><br />

un der ground as well as in build ing struc tures,<br />

e.g. di rectly in con crete.<br />

Not <strong>for</strong> in stal la tions sub ject to se vere elec tri cal<br />

in ter fer ence (see MCCMK).<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

MCMK 1kV<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV U m = 1,2 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1,<br />

IEC 60332-3<br />

CORE IDEN TI FI CA TION<br />

3-wires<br />

4-wires<br />

Self- extinguishing IEC 332-3


MCMK 3½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 25/16 AN 1kV 3 x 35/16 AN 1kV 3 x 50/25 AN 1kV 3 x 70/35 AN 1kV 3 x 95/50 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 30-9 06 001 31-6 06 001 32-3 06 001 33-3 06 001 34-7<br />

Nominal overall diameter mm 25 27 28 32 36<br />

Total weight kg/km 1450 1800 2100 2700 3600<br />

St<strong>and</strong>ard delivery length m 500 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K11 K12 K12 K14 K16<br />

Weight (gable + drum) kg 780 1000 1150 1470 2000<br />

MCMK 3½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 120/70 AN 1kV 3 x 150/70 AN 1kV 3 x 185/95 AN 1kV 3 x 240/120 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 35-4 06 001 36-1 06 001 37-8 06 001 38-5<br />

Nominal overall diameter mm 40 43 48 54<br />

Total weight kg/km 4500 5500 6750 9000<br />

St<strong>and</strong>ard delivery length m 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K18 K18 K20 K22<br />

Weight (gable + drum) kg 2500 3000 3750 4950<br />

MCMK 4½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 25/16 AN 1kV 4 x 35/16 AN 1kV 4 x 50/25 AN 1kV 4 x 70/35 AN 1kV 4 x 95/50 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 40-8 06 001 41-5 06 001 42-2 06 001 43-9 06 001 44-6<br />

Nominal overall diameter mm 28 30 33 35 41<br />

Total weight kg/km 1750 2200 2650 3400 4650<br />

St<strong>and</strong>ard delivery length m 500 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K12 K12 K14 K16 K18<br />

Weight (gable + drum) kg 970 1200 1450 1900 2550<br />

MCMK 4½<br />

CON STRUC TION<br />

Con duc tor Compacted, an nealed (AN), cop per<br />

conductor 25 <strong>and</strong> 35 mm²,<br />

round 50 mm² <strong>and</strong> larger , sector<br />

shaped<br />

Installation Lead-free PVC, core identification<br />

by colours<br />

MCMK 1kV<br />

POWER INSTALLATION CABLES<br />

Laying up Three phase conductors<br />

<strong>and</strong> neutral str<strong>and</strong>ed together<br />

PE/PEN-conductor A layer of cop per wires <strong>and</strong> an<br />

open he lix of cop per tape<br />

Sheath Black, lead free PVC compound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 120/70 AN 1kV 4 x 150/70 AN 1kV 4 x 185/95 AN 1kV 4 x 240/120 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 001 45-3 06 001 46-0 06 001 47-7 06 001 48-4<br />

Nominal overall diameter mm 44 49 55 59<br />

Total weight kg/km 5700 7000 8700 11500<br />

St<strong>and</strong>ard delivery length m 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K20 K22 K22 K24<br />

Weight (gable + drum) kg 3200 4900 4800 6200<br />

23


POWER INSTALLATION CABLES<br />

24<br />

N<br />

AP PLI CA TION<br />

For fixed in stal la tion in doors, out doors <strong>and</strong><br />

un der ground installation.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: –15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion<br />

AMCMK 1 kV<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV U m = 1,2 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1,<br />

IEC 60332-3B<br />

CORE IDEN TI FI CA TION<br />

3-wires<br />

4-wires<br />

Self- extinguishing IEC 332-1<br />

Self- extinguishing IEC 332-3


CON STRUC TION<br />

Con duc tor Compacted, an nealed (AN), aluminium<br />

conductor 25 <strong>and</strong> 35 mm²,<br />

round 50 mm² <strong>and</strong> larger , sector<br />

shaped<br />

Installation Lead-free PVC, core identification<br />

by colours<br />

AMCMK 3½<br />

AMCMK 1 kV<br />

Laying up Three phase conductors <strong>and</strong><br />

neutral str<strong>and</strong>ed together<br />

PE/PEN-conductor A layer of cop per wires <strong>and</strong> an<br />

open he lix of cop per tape<br />

Sheath Black, lead free PVC compound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x16/10 AN 1kV 3 x 35/10 AN 1kV 3 x 70/21 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 225 57-6 06 003 31-0 06 003 33-4<br />

Nominal overall diameter mm 22 27 32<br />

Total weight kg/km 600 1100 1400<br />

St<strong>and</strong>ard delivery length m 1000 500 500<br />

St<strong>and</strong>ard delivery drum K14 K12 K14<br />

Weight (gable + drum) kg 720 650 820<br />

AMCMK 3½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 120/41 AN 1kV 3 x 185/57 AN 1kV 3 x 240/72 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 003 35-8 06 003 37-2 06 003 38-9<br />

Nominal overall diameter mm 40 47 53<br />

Total weight kg/km 2100 3000 3900<br />

St<strong>and</strong>ard delivery length m 500 500 500<br />

St<strong>and</strong>ard delivery drum K16 K20 K22<br />

Weight (gable + drum) kg 1250 1850 2350<br />

AMCMK 4½<br />

POWER INSTALLATION CABLES<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 16/10 AN 1kV 4 x 35/16 AN 1kV 4 x 50/15 AN 1kV 4 x 70/21 AN 1kV 4 x 95/29 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 225 77-4 06 003 41-9 06 003 42-6 06 003 43-3 06 003 44-0<br />

Nominal overall diameter mm 23 31 32 36 41<br />

Total weight kg/km 680 1300 1400 1800 2400<br />

St<strong>and</strong>ard delivery length m 1000 500 500 500 500<br />

St<strong>and</strong>ard delivery drum K14 K14 K14 K16 K18<br />

Weight (gable + drum) kg 800 800 850 1100 1450<br />

AMCMK 4½<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 120/41 AN 1kV 4 x 150/41 AN 1kV 4 x 185/57 AN 1kV 4 x 240/72 AN 1kV 4 x 300/88 AN 1kV<br />

EAN code (SSTL code) 64 100+ 06 003 45-7 06 003 46-04 06 003 47-1 06 003 48-8 06 003 49-5<br />

Nominal overall diameter mm 44 49 53 60 68<br />

Total weight kg/km 2600 3100 3800 4850 6050<br />

St<strong>and</strong>ard delivery length m 500 500 500 500 250<br />

St<strong>and</strong>ard delivery drum K20 K20 K22 K24 K22<br />

Weight (gable + drum) kg 1650 1900 2300 2900 1950<br />

25


INTERFERENCE- PROTECTED 1 kV CA BLES<br />

26<br />

AP PLI CA TION<br />

Fixed indoor, outdoor <strong>and</strong> underground installation<br />

where EMC-properties are required<br />

The EU di rec tive 89/336/EEC on elec tro mag netic<br />

com pati bil ity (EMC) be came ef fec tive on 1st Jan 1996.<br />

The EMC di rec tive to elec tri cal equip ment <strong>and</strong> sys tems.<br />

The equip ment <strong>and</strong> sys tems tar geted in the di rec tive<br />

must be con structed so that their elec tro mag netic<br />

emis sion does not ex ceed a level that would af fect<br />

the proper op era tion of ra dio, tele com mu ni ca tions,<br />

medi cal equip ment, <strong>and</strong> other de vices. The equip ment<br />

must be im mune to in ter fer ence so it can op er ate as<br />

in tended.<br />

Screen ing is es sen tial in en vi ron ments where high<br />

fre quency dis tur bance cur rents <strong>and</strong> fields ex ist.<br />

Such en vi ron ments in clude in dus trial fa cili ties util is ing<br />

fre quency trans <strong>for</strong>mer drives. The in ter fer ing<br />

fre quen cies pro duced by these drives can rise to<br />

hun dreds of mega hertz. There <strong>for</strong>e, the im por tance of<br />

the ca ble’s trans fer im ped ance grows de ci sively.<br />

The smaller the ca ble’s trans fer im ped ance at high<br />

fre quen cies, the bet ter the ca ble’s screen ing abili ties.<br />

Cur rent car ry ing ca paci ties ac cord ing to HD 384.5.523<br />

(or IEC 364- 5- 523): “Elec tri cal in stal la tion of build ings”<br />

-se ction 523: Cur rent car ry ing ca paci ties.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

MCCMK<br />

N<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 12xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

RATED VOLT AGE<br />

U o /U = 0,6/1 kV<br />

STAN DARD<br />

SFS 4880, HD 603-3F S1, IEC 60502-1<br />

CORE IDEN TI FI CA TION<br />

3-wires<br />

4-wires<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor An nealed cop per<br />

2,5 <strong>and</strong> 6 mm² solid<br />

10 <strong>and</strong> 16 mm² str<strong>and</strong>ed<br />

In su la tion Lead- free PVC, core iden ti fi ca tion by<br />

num bers<br />

INTERFERENCE- PROTECTED 1 kV CA BLES<br />

MCCMK<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 3 x 2,5/2,5 3 x 6/6 3 x 10/10 RM<br />

3 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 020 53-9 06 020 55-3 06 020 56-0 06 020 57-7<br />

Nominal overall diameter mm 14 18 21 24<br />

Total weight kg/km 260 470 700 1050<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 7,41 3,08 1,83 1,15<br />

Bending radius m 0,16 0,22 0,25 0,3<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/K9 1000/K11 1000/K12 1000/15G<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 4 x 2,5/2,5 4 x 6/6 4 x 10/10 RM<br />

Fill ing Fill ing com pound<br />

Con cen tric<br />

con duc tor A layer of cop per wires, cop per foil <strong>and</strong><br />

an open he lix of par al lel cop per wires<br />

Sheath Black, lead- free PVC<br />

- marked by me ters<br />

4 x 16/16 RM<br />

EAN code (SSTL code) 64 100+ 06 020 73-7 06 020 75-1 06 020 76-8 06 020 77-5<br />

Nominal overall diameter mm 14,5 19 22 25<br />

Total weight kg/km 290 540 830 1200<br />

Direct current resistance of<br />

conductor at +20 °C.max. Ω/km 7,41 3,08 1,83 1,15<br />

Bending radius m 0,18 0,23 0,27 0,3<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/K9 1000/K11 1000/13G 1000/15G<br />

27


N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits<br />

of elec tri cal equip ment <strong>for</strong> fixed sur face <strong>and</strong><br />

flush- mounted in stal la tions, in doors <strong>and</strong> out doors.<br />

Di rect sun light may change col our of sheath.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion : Ax50 N/mm²<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

In su la tion Black lead free PVC,<br />

core iden ti fi ca tion by num bers<br />

Plas tic- sheat hed cont rol cab le<br />

MMO<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 3714<br />

Self- extinguishing IEC 332-1<br />

Sheath White lead free Li nyl PVC<br />

- marked by me ters<br />

CON TROL CA BLES<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 12 x 1,5 19 x 1,5 27 x 1,5 37 x 1,5 7 x 2,5 12 x 2,5 19 x 2,5<br />

EAN code (SSTL code) 64 100+ 04 120 22-4 04 120 23-1 04 120 24-8 04 120 25-5 04 120 26-2 04 120 33-0 04 120 34-7 04 120 35-4<br />

Nominal overall diameter mm 12 15 18 21 24 14 18 21<br />

Total weight kg/km 230 350 500 700 950 310 500 750<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 12,1 12,1 12,1 12,1 12,1 7,41 7,41 7,41<br />

St<strong>and</strong>ard delivery length<br />

drum m 1000/8E 500/8E 500/8E 500/11G 500/11G 500/8E 500/8E 500/11G<br />

Electrical properties<br />

Capacitance between two<br />

adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km 120...150 120...150 120...150 120...150 120...150 120...150 120...150 120...150<br />

29


CON TROL CA BLES<br />

30<br />

N<br />

AP PLI CA TION<br />

Ca ble <strong>for</strong> the con trol, meas ur ing <strong>and</strong> sig nal cir cuits<br />

of elec tri cal equip ment <strong>for</strong> fixed sur face <strong>and</strong><br />

flush- mounted in stal la tions, in doors <strong>and</strong> out doors.<br />

The con cen tric cop per con duc tor <strong>for</strong>ms a good<br />

elec tro me chani cal pro tec tion <strong>and</strong> a mod er ate<br />

pro tec tion against elec tri cal in ter fer ence.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: -15 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- in a fi nal in stal la tion if bent only once 8xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion Ax50 N/mm²<br />

Elec tro mag netic com pati bil ity<br />

Plas tic- sheat hed cont rol cab le<br />

MCMO<br />

with con cent ric cop per con duc tor<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 3713<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor An nealed cop per wire<br />

In su la tion Black lead free PVC,<br />

core iden ti fi ca tion by num bers<br />

Fill ing Fill ing com pound<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 1,5 12 x 1,5 19 x 1,5 27 x 1,5 37 x 1,5<br />

EAN code (SSTL code) 64 100+ 06 019 01-4 06 019 02-1 06 019 03-8 06 019 04-5 06 019 05-2<br />

Nominal overall diameter mm 15 19 22 26 28<br />

Total weight kg/km 350 500 680 950 1200<br />

Direct current resistance of<br />

conductor at +20 °C max.<br />

conductor’s Ω/km<br />

concentric conductor Ω/km<br />

12,1<br />

3,08<br />

12,1<br />

3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/8E 400/8E 500/11G 500/11G 400/11G<br />

Electrical properties<br />

Capacitance between two<br />

adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of one<br />

conductor at +20 °C <strong>and</strong> 50 Hz nF/km<br />

130...160<br />

200...270<br />

130...160<br />

200...270<br />

12,1<br />

3,08<br />

130...160<br />

200...270<br />

12,1<br />

3,08<br />

130...160<br />

200...270<br />

12,1<br />

2,60<br />

130...160<br />

200...270<br />

Number of conductors <strong>and</strong><br />

cross-section nxmm² 7 x 2,5 12 x 2,5 19 x 2,5 27 x 2,5 37 x 2,5<br />

EAN code (SSTL code) 64 100+ 06 019 21-2 06 019 22-9 06 019 23-6 06 019 24-3 06 019 25-0<br />

Nominal overall diameter mm 18 21 25 29 32<br />

Total weight kg/km 480 690 950 1350 1700<br />

Direct current resistance of<br />

conductor at +20 °C max.<br />

conductor’s Ω/km<br />

concentric conductor Ω/km<br />

7,41<br />

3,08<br />

7,41<br />

3,08<br />

St<strong>and</strong>ard delivery length<br />

drum m 500/8E 500/11G 500/11G 400/11G 300/11G<br />

Electrical properties<br />

Capacitance between two<br />

adjacent conductors<br />

at +20 °C <strong>and</strong> 50 Hz nF/km<br />

Capacity to earth of one<br />

conductor at +20 °C <strong>and</strong> 50 Hz nF/km<br />

130...160<br />

210...280<br />

Plas tic- sheat hed cont rol cab le<br />

MCMO<br />

with con cent ric cop per con duc tor<br />

130...160<br />

210...280<br />

7,41<br />

3,08<br />

130...160<br />

210...280<br />

7,41<br />

2,60<br />

130...160<br />

210...280<br />

CON TROL CA BLES<br />

Con cen tric<br />

con duc tor A layer of cop per wires <strong>and</strong> an open<br />

he lix of par al lel cop per wires<br />

Sheath Black lead free PVC<br />

7,41<br />

2,60<br />

130...160<br />

210...280<br />

31


JUMPER WIRES<br />

32<br />

Plas tic- in su la ted jum per wi res<br />

MKJE 90 H05V2-U, MKJ 90 H05V2-K,<br />

MKJT 90 H05V2-K<br />

AP PLI CA TION<br />

For per ma nent in stal la tion as in te rior ca bling in light ing<br />

<strong>and</strong> other equip ment.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended han dling<br />

tem pera ture: +5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- in a fi nal in stal la tion if bent only once 2xD<br />

MKJE 90 H05V2-U<br />

MKJ 90 H05V2-K<br />

MKJT 90 H05V2-K<br />

RATED VOLT AGE<br />

U o /U = 300/500 V<br />

STAN DARD<br />

SFS 5527 = CENE LEC HD 21<br />

H05V2-U (MKJE 90)<br />

H05V2-K (MKJ 90, MKJT 90)<br />

Self- extinguishing IEC 332-1


CON STRUC TION<br />

Con duc tor MKJE 90 annealed cop per wire,<br />

solid<br />

MKJ 90 an nealed c opper wires,<br />

str<strong>and</strong>ed flexible<br />

MKJT 90 tinned, an nealed c opper<br />

wires, str<strong>and</strong>ed flexible<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm²<br />

MKJE 90<br />

H05V2-U<br />

0,75 VA<br />

MKJE 90<br />

H05V2-U<br />

0,75 RU<br />

MKJE 90<br />

H05V2-U<br />

0,75 MU<br />

MKJE 90<br />

H05V2-U<br />

0,75 SI<br />

EAN code (SSTL code) 64 100+ 04 162 20-0 04 162 22-4 04 156 03-2 04 156 07-0<br />

Nominal overall diameter mm 2,2 2,2 2,2 2,2<br />

Total weight kg/km 11 11 11 11<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 24,5 24,5 24,5 24,5<br />

St<strong>and</strong>ard delivery length<br />

spool m 500 500 500 500<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm²<br />

MKJ 90<br />

H05V2-K<br />

0,75 VA<br />

MKJ 90<br />

H05V2-K<br />

0,75 RU<br />

MKJ 90<br />

H05V2-K<br />

0,75 MU<br />

MKJ 90<br />

H05V2-K<br />

0,75 PU<br />

MKJ 90<br />

H05V2-K<br />

0,75 SI<br />

EAN code (SSTL code) 64 100+ 04 156 50-6 04 162 02-6 04 156 53-7 04 162 26-4 04 156 57-5<br />

Nominal overall diameter mm 2,3 2,3 2,3 2,3 2,3<br />

Total weight kg/km 11 11 11 11 11<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,0 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 500 500 500 500 500<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm²<br />

MKJ 90<br />

H05V2-K<br />

0,75 SI<br />

MKJ 90<br />

H05V2-K<br />

0,75 KEVI<br />

MKJT 90<br />

H05V2-K<br />

0,75 SI<br />

MKJT 90<br />

H05V2-K<br />

0,75 MU<br />

EAN code (SSTL code) 64 100+ 04 162 07-1 04 156 58-2 04 161 07-4 04 156 73-5<br />

Nominal overall diameter mm 2,3 2,3 2,3 2,3<br />

Total weight kg/km 11 11 11 11<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,7 26,7<br />

St<strong>and</strong>ard delivery length<br />

spool m 500 500 500 500<br />

JUMPER WIRES<br />

Plas tic- in su la ted jum per wi res<br />

MKJE 90 H05V2-U, MKJ 90 H05V2-K,<br />

MKJT 90 H05V2-K<br />

In su la tion PVC, core iden ti fi ca tion by colours<br />

33


JUMPER WIRES<br />

34


AP PLI CA TION<br />

For fixed in stal la tion in a con duit, <strong>and</strong> <strong>for</strong> wir ing in<br />

ap pli ances, switch gear <strong>and</strong> con trol gear with<br />

a maxi mum volt age of 1000 V (a.c.) or a maxi mum of<br />

750 V (d.c.) to earth.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +90 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -25 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 3xD<br />

CON STRUC TION<br />

Con duc tor Tinned, an nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

Plas tic- in su la ted jum per wire<br />

MKEMT 90 H07V2-K<br />

Tin ned, fle xib le con duc tor<br />

RATED VOLT AGE<br />

U o /U = 450/750 V<br />

STAN DARD<br />

SFS 5523 <strong>and</strong> CENE LEC HD 21<br />

Self- extinguishing IEC 332-1<br />

JUMPER WIRES<br />

In su la tion Lead-free Li nyl PVC, core iden ti fi ca tion<br />

by col ours<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm² 1,5 MU 1,5 SI 1,5 KEVI 2,5 MU 2,5 SI 2,5 KEVI<br />

EAN code (SSTL code) 64 100+ 04 031 53-7 04 031 57-5 04 031 58-2 04 031 73-5 04 031 77-3 04 031 78-0<br />

Nominal overall diameter mm 3,1 3,1 3,1 3,7 3,7 3,7<br />

Total weight kg/km 21 21 21 32 32 32<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 13,7 13,7 13,7 8,21 8,21 8,21<br />

St<strong>and</strong>ard delivery length<br />

spool m 250 250 250 200 200 200<br />

35


JUMPER WIRES<br />

36<br />

AP PLI CA TION<br />

For fixed in stal la tion in neon lu mi naires.<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +70 °C<br />

- in a short cir cuit (max. 5 s) +160 °C<br />

Low est rec om mended<br />

han dling tem pera ture: -15 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- dur ing in stal la tion 8xD<br />

- in a fi nal in stal la tion if bent only once 4xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

Plas tic- in su la ted con duc tor<br />

MVJ 8 kV<br />

Fle xib le con duc tor<br />

RATED VOLT AGE<br />

U o /U = 8/8 kV<br />

STAN DARD<br />

SFS 5680<br />

Cross-section of conductors<br />

<strong>and</strong> colour mm² 1,5 KE<br />

EAN code (SSTL code) 64 100+ 04 201 03-9<br />

Nominal overall diameter mm 6,7<br />

Total weight kg/km 56<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100<br />

Self- extinguishing IEC 332-1<br />

In su la tion PVC, yel low


AP PLI CA TION<br />

Non- sheat hed, flat, fle xib le, plas tic- in su la ted cord<br />

MST H03VH-H<br />

Cord <strong>for</strong> very light duty use <strong>for</strong> light port able ap pli ences<br />

in do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- Not <strong>for</strong> kitchen or heat ing ap pli ances<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use or<br />

<strong>for</strong> port able tools<br />

- Not <strong>for</strong> sus pend ing light ing fix tures<br />

Maxi mum per mis si ble tem pera ture of con duc tor:<br />

- in con tinu ous use +40 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

In su la tion PVC cov er ing two par al lel con duc tors<br />

RATED VOLT AGE<br />

U o /U = 300/300 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H03VH-H<br />

Self- extinguishing IEC 332-1<br />

Iden ti fi ca tion<br />

of con duc tors A lon gi tu di nal ridge on the sur face of<br />

in su la tion on one of the con duc tor’s<br />

Number <strong>and</strong> cross-section of conductors<br />

<strong>and</strong> insulation colour nxmm² 2 x 0,75 VA 2 x 0,75 HA 2 x 0,75 KIR 2 x 0,75 MU<br />

EAN code (SSTL code) 64 100+ 04 171 20-2 04 171 21-9 04 171 28-8 04 171 23-3<br />

Nominal overall diameter mm 2,8x5,6 2,8x5,6 2,8x5,6 2,8x5,6<br />

Total weight kg/km 26 26 26 26<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 200 200 200 200<br />

FLEXI BLE CORDS<br />

37


FLEXI BLE CORDS<br />

38<br />

N<br />

AP PLI CA TION<br />

Cord <strong>for</strong> light duty use <strong>for</strong> port able ap pli ences in<br />

do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- Not <strong>for</strong> kitchen or heat ing ap pli ances<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use or<br />

<strong>for</strong> non do mes tic port able tools<br />

The weight of the light ing fix ture hang ing from the ca ble<br />

must not ex ceed 2 kg.<br />

Maxi mum per mis si bletem pera ture of con duc tor:<br />

- in con tinu ous use +60 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed<br />

flexi ble<br />

Light, flat, fle xib le, plas tic- in su la ted cord<br />

MSO H03VVH2-F<br />

2-wires<br />

RATED VOLT AGE<br />

U o /U = 300/300 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H03VVH2-F<br />

CORE IDEN TI FI CA TION<br />

N-system<br />

Self- extinguishing IEC 332-1<br />

Insulation PVC, core identification by colours<br />

Sheath PVC cov er ing two in su lated <strong>and</strong> par al lel<br />

con duc tors, flat<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 2 x 0,75 N VA 2 x 0,75 N HA 2 x 0,75 N RU 2 x 0,75 N MU<br />

EAN code (SSTL code) 64 100+ 04 181 20-1 04 181 21-8 04 181 22-5 04 181 23-2<br />

Nominal overall diameter mm 3,3x5,4 3,3x5,4 3,3x5,4 3,3x5,4<br />

Total weight kg/km 31 31 31 31<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 200 200 200 200


N<br />

AP PLI CA TION<br />

Cord <strong>for</strong> light duty use <strong>for</strong> port able ap pli ences in<br />

do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- Not <strong>for</strong> kitchen or heat ing ap pli ances<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use or<br />

<strong>for</strong> non do mes tic port able tools<br />

The weight of the light ing fix ture hang ing from the ca ble<br />

must not ex ceed 2 kg.<br />

Maxi mum per mis si bletem pera ture of con duc tor:<br />

- in con tinu ous use +60 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

CON STRUC TION<br />

Con duc tor An nealed cop per wires, str<strong>and</strong>ed<br />

flexi ble<br />

Light, round, fle xib le, plas tic- in su la ted cord<br />

MSOY H03VV-F<br />

2-wires<br />

RATED VOLT AGE<br />

U o /U = 300/300 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H03VV-F<br />

CORE IDEN TI FI CA TION<br />

N-system<br />

Self- extinguishing IEC 332-1<br />

Insulation PVC, core identification by colours<br />

Sheath PVC cov er ing two in su lated str<strong>and</strong>ed<br />

con duc tors, round<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 2 x 0,75 N VA 2 x 0,75 N MU<br />

EAN code (SSTL code) 64 100+ 04 181 70-6 04 181 73-7<br />

Nominal overall diameter mm 5,4 5,4<br />

Total weight kg/km 41 41<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 26,0<br />

St<strong>and</strong>ard delivery length<br />

spool m 100 100<br />

FLEXI BLE CORDS<br />

39


FLEXI BLE CORDS<br />

40<br />

N<br />

AP PLI CA TION<br />

Cord <strong>for</strong> or di nary duty use <strong>for</strong> port able ap pli ences in<br />

do mes tic prem ises, kitch ens <strong>and</strong> of fices.<br />

- For house hold ap pli ences in dry <strong>and</strong> damp prem ises.<br />

- Not <strong>for</strong> out door use, in dus trial use, ag ri cul tural use<br />

The weight of a light ing fix ture hang ing from the ca ble<br />

must not ex ceed 2 kg.<br />

Maxi mum per mis si bletem pera ture of con duc tor:<br />

- in con tinu ous use +60 °C<br />

- in a short cir cuit (max. 5 s) +150 °C<br />

Low est rec om mended<br />

han dling tem pera ture: +5 °C<br />

Mini mum rec om mended<br />

bend ing ra dius:<br />

- in nor mal us age 6xD<br />

Fle xib le, plas tic- in su la ted cord<br />

MSK H05VV-F<br />

2-wires<br />

RATED VOLT AGE<br />

U o /U = 300/500 V<br />

STAN DARD<br />

SFS 5525 = CENE LEC HD 21<br />

H05VV-F<br />

CORE IDEN TI FI CA TION<br />

N-system<br />

3-wires<br />

4-wires<br />

5-wires<br />

Self- extinguishing IEC 332-1<br />

S-ystem


CON STRUC TION<br />

Con duc tor An nealed cop per wires,<br />

str<strong>and</strong>ed flexi ble<br />

Fle xib le, plas tic- in su la ted cord<br />

MSK H05VV-F<br />

In su la tion PVC, core iden ti fi ca tion by col ours<br />

Sheath PVC, round<br />

WITH PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 3 x 0,75 S VA 3 x 1,0 S VA 3 x 1,5 S VA 4 x 0,75 S VA 4 x 1,5 S VA<br />

EAN code (SSTL code) 64 100+ 04 197 20-2 04 197 21-9 04 197 22-6 04 197 30-1 04 197 32-5<br />

Nominal overall diameter mm 6,6 7,0 8,3 7,2 9,3<br />

Total weight kg/km 61 72 100 75 130<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 19,5 13,3 26,0 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100 100 100<br />

WITH PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 5 x 1,0 S VA 5 x 1,5 S VA 5 x 2,5 S VA 3 x 1,5 S HA<br />

EAN code (SSTL code) 64 100+ 04 197 41-7 04 197 42-4 04 197 43-1 04 198 22-3<br />

Nominal overall diameter mm 8,6 10,3 12,2 8,3<br />

Total weight kg/km 110 165 250 102<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 19,5 13,3 7,98 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 50 100<br />

WITHOUT PROTECTIVE CONDUCTOR<br />

Number <strong>and</strong> cross-section of<br />

conductors <strong>and</strong> sheath colour nxmm² 2 x 0,75 N VA 2 x 1,0 N VA 2 x 1,5 N VA<br />

EAN code (SSTL code) 64 100+ 04 194 10-2 04 194 11-9 04 194 12-6<br />

Nominal overall diameter mm 6,2 6,6 7,6<br />

Total weight kg/km 51 60 80<br />

Direct current resistance of<br />

conductor at +20 °C max. Ω/km 26,0 19,5 13,3<br />

St<strong>and</strong>ard delivery length<br />

coil m 100 100 100<br />

FLEXI BLE CORDS<br />

41


42<br />

DATA TRANS MIS SION CA BLES<br />

All auto ma tion ca bles, such as in stru men ta tion, sig nal <strong>and</strong><br />

data net work ca bles, are data trans mis sion ca bles.<br />

They are cop per ca bles with a maxi mum op er at ing<br />

volt age of 75 V or op ti cal fi bre ca bles.<br />

They trans mit in <strong>for</strong> ma tion in an elec tric or op ti cal <strong>for</strong>m.<br />

The trans mit ted in <strong>for</strong> ma tion may con sist of speech, sound,<br />

mov ing or still pic tures, text, data, meas ur ing or con trol<br />

data or it may be the sig nal of a fire de tec tor or<br />

a bur glar alarm.<br />

The trans mit ted sig nal may be ana log or digi tal.<br />

The ca pac ity of an ana log trans mis sion is meas ured by<br />

a b<strong>and</strong> width which is the fre quency range re quired to<br />

trans mit a cer tain sig nal. In digi tal trans mis sion a cer tain<br />

number of sig nals are trans mit ted in a time unit <strong>and</strong> this is<br />

called trans mis sion speed. A cer tain trans mis sion speed<br />

cor re sponds to a cer tain b<strong>and</strong> width. That is why the term<br />

b<strong>and</strong> width can also be used in digi tal trans mis sion.<br />

The b<strong>and</strong> width re quired by a digi tal sig nal is al ways<br />

wider than that of a cor re spond ing ana log sig nal.<br />

Ca ble de sign<br />

Data trans mis sion ca bles are di vided into three groups:<br />

sym met ri cal ca bles, co ax ial ca bles <strong>and</strong> op ti cal fi bre<br />

ca bles.<br />

a)<br />

b)<br />

c)<br />

conductor<br />

insulation<br />

inner conductor<br />

insulation<br />

outer conductor<br />

core<br />

shell<br />

(a) The ba sic struc ture of a sym met ri cal pair, (b) a co ax ial<br />

pair <strong>and</strong> (c) an op ti cal fi bre.<br />

A sym met ri cal ca ble con sist of one or sev eral sym met ri cal<br />

pairs. A pair con sists of two or four iden ti cal in su lated<br />

con duc tors which are mutually twisted into a pair.<br />

The con duc tors of a pair are alike in their elec tric<br />

dis po si tion. Sym met ri cal ca bles are either screened or<br />

un screened.<br />

A co ax ial pair is the ba sic ele ment of the co ax ial ca ble.<br />

It con sists of two con duc tors, an in ner con duc tor <strong>and</strong><br />

an outer con duc tor. These are dif fer ent in their struc ture<br />

<strong>and</strong> elec tric dis po si tion. The cy lin dri cal outer con duc tor<br />

is con cen tri cally around the in ner con duc tor.<br />

In an op ti cal fi bre ca ble, the sig nal pro ceeds in the <strong>for</strong>m of<br />

light along the op ti cal fi bre. The fi bre, con sist ing of a core<br />

<strong>and</strong> a shell, is made from quartz glass or plas tic.<br />

The re frac tive in dex of the core is higher than that of<br />

the shell, <strong>and</strong> this causes a re flec tion when the light hits<br />

the shell.<br />

GE NE RAL<br />

De pend ing on the dif fer ent in stal la tion con di tions,<br />

the ca bles are also di vided into in door ca bles <strong>and</strong> out door<br />

ca bles. Sel fex tin guish ing <strong>and</strong> bend abil ity are typi cal<br />

prop er ties of in door ca bles. They are also lighter in<br />

con struc tion <strong>and</strong> smaller in size than the cor re sponding<br />

out door ca bles. The serv ice tem pera ture range of out door<br />

ca bles is wide. They are re sis tant to e.g. hu mid ity, sun light<br />

<strong>and</strong> han dling in out door con di tions. De pend ing on<br />

the in stal lat ion site, out door ca bles can also be di vided<br />

into duct, bur ied, sub ma rine <strong>and</strong> aer ial ca bles.<br />

ELEC TRI CAL PROP ER TIES<br />

The trans mis sion ca pac ity of the ca ble is es sen tially<br />

ef fected by re sis tance, ca paci tance, im ped ance,<br />

at tenua tion <strong>and</strong> cros stalk.<br />

Re sis tance<br />

Re sis tance is caused by the con duc tor to<br />

the elec tric cur rent <strong>and</strong> it is de pend ent on the cross<br />

sec tion <strong>and</strong> the ma te rial of the con duc tor,<br />

the tem pera ture, the sig nal fre quency <strong>and</strong> the metals<br />

close to the con duc tor.<br />

For twisted- pair ca bles it is given as loop re sis tance which<br />

in cludes the ef fect of both the sup ply con duc tor <strong>and</strong><br />

the re turn con duc tor. The re sis tance is given per unit of<br />

the length, i.e Ω /km.<br />

Ca paci tance<br />

Ca paci tance is in er tia to volt age changes be tween<br />

the con duc tors of a pair. It is de pend ent on the di ame ter of<br />

the con duc tors, the dis tance be tween them,<br />

the in su la tion, the ma te rial around the in su la tion <strong>and</strong><br />

the elec tric po ten tial of the in su la tion.<br />

The ca paci tance in creases if the dis tance be tween<br />

the con duc tors is re duced or if the di ame ter of<br />

the con duc tors in creases. It is di rectly pro por tional to<br />

the di elec tric con stant which is spe cific to every in su la tion<br />

ma te rial. The ca paci tance is given per unit of the length,<br />

i.e. nF/km.<br />

Im ped ance<br />

Im ped ance gives the ra tio of the volt age be tween<br />

the con duc tors to the cur rent car ried therein. It is also<br />

known as surge im ped ance or char ac ter is tic im ped ance.<br />

With trans mis sion ca bles all these terms have the same<br />

mean ing. The unit of im ped ance is ohm (Ω).<br />

The im ped ance of ho mo ge ne ous pair is con stant across<br />

the whole length of the pair. The volt age <strong>and</strong> the cur rent<br />

are at tenu ated but their ra tio is con stant, i.e. equal to<br />

the im ped ance. The im ped ance is there <strong>for</strong>e one of<br />

the char ac ter is tics of a pair. At low fre quen cies,<br />

the im ped ance is sig nifi cant only with long ca bles.<br />

For ex am ple at a fre quency be low 29 kHz it be gins to have<br />

sig nifi cance if the ca ble is longer than 1,000 m.<br />

At a fre quency of 1,000 kHz or higher, the im ped ance is<br />

very im por tant <strong>for</strong> match ing. This means that<br />

the im ped ance of the unit or com po nent con nected to<br />

the pair must be equiva lent to that of the pair.


At tenua tion<br />

When the sig nal pro ceeds in the pair, it loses some of its<br />

ef fect, while both the volt age <strong>and</strong> the cur rent de crease<br />

as a func tion of the dis tance. The at tenua tion is given in<br />

deci bels per unit of length, e.g. dB/100 m, <strong>and</strong> it is<br />

af fected by the di ame ter of the in su la tion, the con duc tance<br />

of the con duc tor <strong>and</strong> the in su la tion prop er ties. The<br />

at tenua tion in creases with a higher fre quency <strong>and</strong> at a<br />

ris ing tem pera ture. With an in crease of one de gree in the<br />

tem pera ture, the in cre ment in the at tenua tion is 2 ‰.<br />

Cros stalk<br />

Cros stalk ap pears when sig nals are cou pled from one pair<br />

to an other. In sym met ri cal ca bles the cros stalk arises<br />

above all be cause of in com plete sym me try.<br />

Also the im ped ance match ings <strong>and</strong> cou pling modes of<br />

the pairs play a role in cros stalk which is an un de sired<br />

phe nome non. For a suc cess ful sig nal trans mis sion, it is<br />

im por tant to keep cros stalk within cer tain lim its.<br />

In ap pli ca tions with great dif fer ences in the sig nal lev els of<br />

the pairs, the ca ble must be es pe cially re sis tant to<br />

cros stalk.<br />

SE LEC TION OF THE CA BLE TYPE<br />

Data trans mis sion ca bles are speci fied in great de tail <strong>for</strong><br />

a number of ap pli ca tions. The choice is to be made<br />

ac cord ing to a speci fi ca tion or a stan dard. But this is not<br />

al ways pos si ble, which is why the fol low ing facts are very<br />

use ful.<br />

It is im por tant to con sider the pur pose <strong>for</strong> the use of<br />

the ca ble <strong>and</strong> the serv ice en vi ron ment be <strong>for</strong>e the ca bling<br />

plan is made.<br />

A ca ble is sub jected to me chani cal loads dur ing<br />

the in stal la tion. It may also be ex posed to vi bra tion, shock<br />

<strong>and</strong> fric tion in its serv ice en vi ron ment. These can of ten be<br />

avoided by proper rout ing or by shield ing the ca ble with<br />

a tube. Str<strong>and</strong>ed con duc tors are rec om mended <strong>for</strong> use in<br />

dif fi cult in stal la tion con di tions, be cause they are eas ier to<br />

bend <strong>and</strong> fatigue- resistant <strong>and</strong> will not break as eas ily as<br />

JA MAK ®<br />

JA MAK ® ARM<br />

CONTENTS<br />

wire con duc tors. Most str<strong>and</strong>ed con duc tors are tinned<br />

to pre vent cor ro sion.<br />

Ca bles are sub jected to chemi cal loads es pe cially in<br />

in dus trial en vi ron ments where they may be ex posed to oil<br />

<strong>and</strong> chemi cal spills <strong>and</strong> cor ro sive gases like sul phur<br />

di ox ide.<br />

Also high tem pera tures, a high rela tive hu mid ity <strong>and</strong><br />

fire risks must be taken into ac count when the ca ble is<br />

se lected.<br />

The sheath ing ma te rial has also a great sig nifi cance when<br />

air prop er ties are con sidered. The most com monly used<br />

ma te ri als are poly eth yl ene (PE) <strong>and</strong> poly vinyl chlo ride<br />

(PVC). PVC is the most popu lar sheath ing ma te rial in<br />

in door in stal la tions be cause it meets the re quire ments of<br />

the IEC 332-1 burn ing test, in which the ca ble is clas si fied<br />

as self- extinguishing. A PVC- sheathed ca ble is not<br />

self- burning <strong>and</strong> will not spread the fire. But, al most all<br />

or ganic mat ter is de stroyed by fire, which is why also<br />

the emis sion of smoke <strong>and</strong> the com bus tion resi due of<br />

the ca ble need to be taken into ac count. Burn ing PVC<br />

re leases chlo rine <strong>and</strong> it <strong>for</strong>ms with wa ter va pour<br />

haz ard ous hy dro chlo ric acid. This is why halogen- free<br />

ca bles are getting more popular (see sym met ri cal<br />

halogen- free lnstru men ta tion ca bles).<br />

And fluoro plas tics are the best of all - both elec tri cally <strong>and</strong><br />

me chani cally.<br />

The maxi mum serv ice tem pera ture with or di nary PE <strong>and</strong><br />

PVC ca bles is + 70 de grees Cel sius.<br />

The ca bles which are to be bur ied di rectly are gen er ally<br />

ar moured.<br />

Screen ing<br />

The elec tro mag netic in ter fer ence in the ca bles are<br />

ca paci tive, in duc tive or caused by a ra dia tion field.<br />

A gal vanic cou pling may also cause in ter fer ence.<br />

43


44<br />

The ta ble be low shows the types of in ter fer ence <strong>and</strong><br />

re spec tive screen ing:<br />

In ter fer ence Cause Screen ing<br />

Ca paci tive<br />

In duc tive<br />

Ra dia tion<br />

Gal vanic<br />

Cros stalk<br />

Elec tric field<br />

e.g. high- voltage ca ble<br />

Mag netic field<br />

e.g. power ca ble<br />

Ra dia tion field<br />

e.g. Radiotransmitter,<br />

ra dar, re lay or tran sis tor<br />

E.g. in cor rectly earthed<br />

serv ice net work<br />

Elec tro mag netic<br />

cou pling be tween the<br />

dif fer ent pairs of<br />

the ca ble<br />

Pair twist ing,con duct ing<br />

metal shields<br />

Pair twist ing, ar mour ing,<br />

fer ro mag netic screen ing<br />

Pair twist ing, con duct ing<br />

metal shields, proper<br />

earth ing<br />

The cir cuits are in su lated<br />

from each other <strong>and</strong> the<br />

ground<br />

Suit able twist length<br />

pairshielding<br />

Of course price is also an im por tant fac tor in<br />

the se lec tion of a ca ble. When you com pare the costs of<br />

e.g. screened <strong>and</strong> un screened ca bles, the fol low ing<br />

de tails are im por tant to re mem ber:<br />

— ca ble in vest ments are small com pared with<br />

the equip ment in vest ments<br />

— fail ures, <strong>for</strong> ex am ple be cause of in ade quate<br />

screen ing, are usu ally de tected in the serv ice -<br />

not be <strong>for</strong>e<br />

— re place ment of a ca ble af ter wards is ex pen sive,<br />

time- consuming <strong>and</strong> dif fi cult<br />

Ease of in stal la tion<br />

The slid ing prop er ties of the ca ble are im por tant <strong>for</strong><br />

in stal la tion.<br />

The ca ble is eas ier to pull if the sheath is made of<br />

low fric tion LINYL- PVC. This is the sheath ing ma te rial<br />

used by NK Ca bles uses in our in door ca bles. The rat ings<br />

should be ob served in the in stal la tion of each ca ble type.<br />

Avail abil ity, qual ity <strong>and</strong> tech ni cal sup port are other<br />

ma jor con sid era tions in the se lec tion of a ca ble.<br />

The fol low ing sum ma rized ques tions cover most of<br />

the es sen tial de tails:<br />

CONTENTS<br />

1. What is the type of the ca ble? (Even if the type is<br />

not known, get in touch <strong>and</strong> check if there is<br />

a simi lar type.)<br />

2. What kind of con nec tion or cou pling is used in<br />

the sys tem?<br />

3. What is the trans mis sion fre quency or the data<br />

trans mis sion speed?<br />

4. How many con duc tors or fi bres are needed in<br />

the ca ble?<br />

5. What is the im ped ance of the equip ment?<br />

6. What in ter fer ence is there in the en vi ron ment?<br />

(See the sec tion on screen ing.)<br />

7. What is the serv ice en vi ron ment <strong>for</strong> the ca bles <strong>and</strong><br />

what are they used <strong>for</strong>? Are they in door or out door<br />

ca bles? Is the in stal la tion fixed, semi fixed or mo bile?<br />

8. Is the ca ble sub jected to me chani cal or chemi cal<br />

loads?<br />

9. Con <strong>for</strong>mity to stan dards?<br />

IN DUS TRIAL NET WORKS<br />

In dus trial auto ma tion has developed rap idly in the past few<br />

years <strong>and</strong> will de velop at an ac cel er ated speed in<br />

the fu ture. Ca ble de sign fol low the lat est trends very<br />

closely. The ex ist ing ca ble de signs can be used in digi tal<br />

field buses, but also new designs are to come. Lo cal area<br />

net works have be come a part of in dus trial net works.<br />

At the mo ment they are used to han dle the trans mis sion<br />

at the high est level of in dus trial net works, i.e. Between<br />

the plant com puter <strong>and</strong> the pro cess com puter.<br />

More de tails must be taken into consideration in<br />

the de sign of in dus trial auto ma tion than in of fice.<br />

The buses of in dus trial auto ma tion sys tems are in tended<br />

<strong>for</strong> con tinu ing serv ice. It is im por tant that the mes sages<br />

are ab so lutely fault less <strong>and</strong> the re sponse times ac cu rate.<br />

Pro tec tion against in ter fer ences must be firm. This is seen<br />

e.g.in the ca ble con struc tions <strong>and</strong> their routings.<br />

Ca bles have a long serv ice life <strong>and</strong> are there <strong>for</strong>e<br />

an im por tant part of the in dus trial plant. Well- designed<br />

ca bling works <strong>for</strong> sev eral ma chine gen era tion. That is why<br />

spe cial at ten tion should be paid to the de sign <strong>and</strong><br />

im ple men ta tion of the ca bling.<br />

SYM MET RI CAL HALOGEN- FREE<br />

IN STRU MEN TA TION CA BLES<br />

Halogen free, HF-ca bles, pro vide bet ter fire safety than<br />

tra di tional PVC- sheathed ca bles. They are selfex<br />

tin guish ing like PVC- sheathed ca bles <strong>and</strong> do not spread<br />

the fire. In a fire they emit much less visi bil ity-re duc ing<br />

smoke than PVC- sheathed ca bles giv ing peo ple more time<br />

to es cape from the haz ard ous area <strong>and</strong> also more time <strong>for</strong><br />

fire fight ing. The smoke is also less ir ri tat ing <strong>and</strong> toxic. It<br />

doesn’t con tain harmfull hydrochloric acid or other<br />

cor ro sive gases <strong>for</strong> equipment of the structures. This<br />

pre vents smoke dam ages which are of ten larger than<br />

those caused by the fire.<br />

The self- extinguishing prop erty of the halogen free<br />

sheath ing ma te rial is based on eth yl ene co poly mers <strong>and</strong><br />

it’s sub stance which de com poses respond to heat with<br />

cool ing the ca ble <strong>and</strong> re leas ing wa ter va pour. The re sult<br />

of a pro tect ing layer of ash is <strong>for</strong>med on the ca ble <strong>and</strong><br />

around the ca ble an ex tin guish ing shield ing<br />

at mos phere of wa ter va pour. A dis ad van tage of<br />

the halogen- free ma te rial is that the sheath is less re sis tant<br />

to me chani cal loads <strong>and</strong> stiffer than a PVC sheath.<br />

Halogenfree ca bles are also sup plied by NK Ca bles.<br />

Fir e per<strong>for</strong>mance prop er ties of ca bles<br />

Prop erty Stan dard<br />

Flame re tar dant<br />

Fire re tar dant<br />

Fire re sis tant<br />

IEC 332-1<br />

IEC 332-3<br />

IEC 331<br />

Low smoke IEC 1034-1 ja IEC 1034-2<br />

Halo gen free,<br />

zero halo gen<br />

IEC 754-1 ja IEC 754-2<br />

(hal.quan tity


OP TI CAL FI BRE CA BLES IN IN DUS TRY<br />

Op ti cal fi bre ca bles are in creas ingly used in in dus try.<br />

This is di rectly pro por tional to the ex p<strong>and</strong> ing data<br />

trans mis sion. Op ti cal fi bre cables are used gen er ally at<br />

the high est level of in dus trial net works. There is also more<br />

<strong>and</strong> more needed <strong>for</strong> data trans mis sion at the lower lev els<br />

of the net work hi er ar chy. The mi cro com put ers used <strong>for</strong><br />

pro duc tion con trol are of ten next to the pro duc tion<br />

equip ment.<br />

The closer to the ma chines <strong>and</strong> equip ment the data<br />

trans mis sion lines run, the greater the elec tro mag netic<br />

in ter fer ence. Power trans fers, elec tric mo tor fields,<br />

thy ris tor con trols <strong>and</strong> elec tric weld ing are some of<br />

the ma jor sources of in ter fer ence. Also earth po ten tial<br />

dif fer ences <strong>and</strong> light ning may cause dis tur bances.<br />

The op ti cal fi bre ca ble is an ideal so lu tion <strong>for</strong><br />

an en vi ron ment ex posed to in ter fer ence. Since it is to tally<br />

in sen si tive to elec tro mag netic in ter fer ence, <strong>for</strong> ex am ple<br />

the ca ble rout ing can be made in the easi est pos si ble way.<br />

Even po ten tial dif fer ences are not a prob lem be cause<br />

fi bres are glass. A small at tenua tion will not cause<br />

prob lems at long trans mis sion dis tances. The large<br />

trans mis sion ca pac ity of the op ti cal fi bre ca ble can also be<br />

util ized in the fu ture, be cause the same ca ble sys tem will<br />

be suf fi cient <strong>for</strong> fu ture gen era tions of com put ers.<br />

Op ti cal fi bre ca ble does not cause spark ing <strong>and</strong> its small<br />

size is ad van ta geous <strong>for</strong> ex am ple in rout ing so lu tions.<br />

CONTENTS<br />

Price of fibre optics is high but in the in ter fer ence<br />

conditions to day fi bre op tics are also an eco nomi cally<br />

sen si ble so lu tion. Be sides it is of ten the only way of<br />

mak ing the con nec tion.<br />

Knowl edge of fi bre op tics is not nec es sary <strong>for</strong><br />

the con struc tion of an op ti cal fi bre con nec tion be cause<br />

there are ready- made so lu tions. The op ti cal fi bre<br />

con nec tion may be be tween two elec tric in ter faces or<br />

be tween two op ti cal fi bre con nec tors. The cli ent must only<br />

spec ify the length of the ca ble, the number of fi bres <strong>and</strong><br />

the con nec tor suited <strong>for</strong> the equip ment or the elec tric<br />

con nec tion. Es pe cially <strong>for</strong> short dis tances, it is sen si ble to<br />

in stall ready- made har nes sies in which the con nec tors are<br />

pro tected against me chani cal loads dur ing the in stal la tion.<br />

At long dis tances <strong>and</strong> with a large number of fi bres,<br />

the op ti cal fi bre ca ble should be ter mi nated at<br />

the in stal la tion site. This is a pro cess that re quires spe cial<br />

equip ment <strong>and</strong> knowl edge, <strong>and</strong> it may be pur chased as<br />

a serv ice from e.g. NK Ca bles, to gether with the ca ble <strong>and</strong><br />

the ter mi nal equip ment.<br />

More in <strong>for</strong> ma tion about op ti cal fi bre trans <strong>for</strong>m ers <strong>and</strong><br />

ca bles, ter mi na tion boxes <strong>and</strong> cross- connection sys tems<br />

<strong>for</strong> fi bre op tics are found in the prod uct cata logues<br />

“Op ti cal Tele com mu ni ca tions <strong>and</strong> Lo cal Area Ca bles” <strong>and</strong><br />

“Ac ces so ries <strong>and</strong> Sup plies <strong>for</strong> Op ti cal Fi bre Ca bles”.<br />

45


IN STRU MEN TA TION CA BLES<br />

46<br />

AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Audio sys tems<br />

— Auto ma tion — Suit able <strong>for</strong> Maxi<br />

— In stru men ta tion Ter mipoint con nec tions<br />

Suit able spe cially <strong>for</strong> digi tal <strong>and</strong> low level analog sig nal<br />

trans mis sion. The con struc tion gives an ex cel lent<br />

pro tec tion against elec tro mag netic in ter fer en cies.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

JA MAK ®<br />

IDEN TI FI CA TION<br />

Units marked with numbers,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Shield Plas tic-alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x( 2+1) x 0,5 4 x (2+1) x 0,5 8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 52-0 02 642 54-4 02 642 58-2 02 642 62-9 02 642 64-3 02 642 68-1<br />

Nomi nal di ame ter mm 8,0 9,5 13,0 15,0 21,0 29,0<br />

Mass kg/km 70 110 200 280 530 1000<br />

De liv ery length m 1000/200 1000/200 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES, 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10 %<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

JA MAK is also available as halo gen free (JAMAK- HF) <strong>and</strong> more effectively shielded (JAMAK-C) ver sion.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5


AP PLI CA TIONS<br />

— Fixed out door — Proc ess con trol<br />

in stal la tions — Audio sys tems<br />

— Auto ma tion — Suit able <strong>for</strong> Maxi<br />

— In stru men ta tion Ter mipoint con nec tions<br />

Suit able spe cially <strong>for</strong> digi tal <strong>and</strong> low level analog sig nal<br />

trans mis sion. The con struc tion gives an ex cel lent<br />

pro tec tion against elec tro mag netic in ter ference.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

CONSTRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 4 x (2+1) x 0,5<br />

Instru men ta ti on cab le<br />

JA MAK ® ARM<br />

IN STRU MEN TA TION CA BLES<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

Shield Plas tic/alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Ar mour ing Wrapped steel b<strong>and</strong><br />

Outersheath Black PVC<br />

8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 72-4 02 642 78-0 02 642 82-7 02 642 84-1 02 642 88-9<br />

Nomi nal di ame ter mm 9,5 13,0 15,0 21,0 29,0<br />

Nomi nal di ame ter mm 13,5 17,0 19,0 25,0 33,0<br />

Mass kg/km 240 350 470 820 1420<br />

De liv ery lenght m 1000 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10 %<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

IDEN TI FI CA TION<br />

Units marked with number tape,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

JA MAK ARM is also available as halo gen free (JAMAK ARM- HF) <strong>and</strong> more effectively shielded (JAMAK-C-ARM) ver sion.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5<br />

47


IN STRU MEN TA TION CA BLES<br />

48<br />

USE<br />

The EMC-directive came into <strong>for</strong>ce 1.1.1996. EMC means<br />

Elec tro mag netic Com pat ibil ity. This EMC- directive is<br />

applied to equipment <strong>and</strong> sys tems, but not <strong>for</strong><br />

com po nents <strong>and</strong> equip ment, so ca bles alone are out side<br />

this directive. How ever ca bles are a part of a sys tem <strong>and</strong> it<br />

is clear that cables with bet ter EMC- properties are<br />

required.<br />

NK Ca bles has developed a more effectively shielded<br />

version of in stru men ta tion ca ble JA MAK called JAMAK-C<br />

which has bet ter EMC- properties.<br />

In stal la tions which de m<strong>and</strong> bet ter EMC- properties, where<br />

in stru ments <strong>and</strong> sys tems, are ex pected to work de spite of<br />

elec tro mag netic dis tur bances <strong>and</strong> wi thout dis turb ing other<br />

in stru ments <strong>and</strong> sys tems elec tro mag neti cally.<br />

CON STRUC TION<br />

Dou ble alu mini um foil pro tec tion: two plas tic-alu min ium<br />

tapes <strong>and</strong> ground wire be tween tapes with thicker<br />

alu min ium tape having the met al coating on the out side<br />

(plas tic-alu min ium tape) it is pos si ble to make a contact<br />

with the shield in lead- throughs <strong>and</strong> con nec tors in<br />

a an gle of 360°.<br />

Instal la ti ons which de m<strong>and</strong> bet ter EMC- pro per ties<br />

JA MAK ® -C<br />

ELEC TRI CAL PROP ER TIES<br />

Screening effectiveness of ca bles can be de scribed with<br />

trans fer impedance, unit is mΩ/m. The smaller<br />

the trans fer impedance, the bet ter are the EMC/shield ing<br />

prop er ties of the ca bles.<br />

In the ta ble be low are compared or di nary JA MAK <strong>and</strong><br />

JAMAK-C, trans fer impedances.<br />

Fre quency<br />

MHz<br />

50<br />

100<br />

IN STAL LA TION<br />

Trans fer impedance, nominal<br />

mΩ/m<br />

JA MAK JAMAK-C<br />

2,0<br />

3,0<br />

0,4<br />

0,3<br />

When the sheath is taken away, the outer plas ticalu<br />

min ium tape can also be taken away. Then comes the<br />

in ner plas tic-alu min ium tape the metalcoating on the<br />

outside. Af ter this it is pos si ble to make a contact with the<br />

shield <strong>and</strong> connector ac cord ing to connector<br />

manu fac torer’s ad vice in a angle of 360°.<br />

In ner<br />

alu min ium tape<br />

Outer<br />

alu min ium tape Ground wire<br />

The right to al tera tions re served.


Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CONSTRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally with<br />

plas tic-alu min ium tape shielded pair,<br />

earth con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

JA MAK ® -C<br />

IN STRU MEN TA TION CA BLES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x (2+1) x 0,5 4 x (2+1) x 0,5 8 x (2+1) x 0,5 12 x (2+1) x 0,5 24 x (2+1) x 0,5 48 x (2+1) x 0,5<br />

EAN code (SSTL code) 64 100+ 02 642 22-3 02 642 24-7 02 642 26-1 02 642 28-5 02 642 30-8 02 642 32-2<br />

Nomi nal di ame ter mm 8,5 10,0 13,5 15,5 21,5 29,5<br />

Mass kg/km 75 115 210 290 540 1030<br />

De liv ery lenght m 1000 1000 1000 1000 1000 500<br />

ELEC TRI CAL PROP ER TIES<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 85<br />

Im ped ance, 10 MHz Ω 70 ± 10<br />

Mini mum in su la tion re sis tance GΩ x km 2<br />

Ve loc ity fac tor 0,66<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

IDEN TI FI CA TION<br />

Unit marked with number tape,<br />

a- conductors are blue <strong>and</strong> b- conductors are red.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant)<br />

Com mon Two plas tic-alu min ium tapes <strong>and</strong><br />

a ground<br />

Shield wire be tween tapes<br />

Sheath Grey LINYL- PVC<br />

JAMAK-C is also available as halo gen free (JAMAK- C- HF) ver sion. The right to al tera tions re served.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,6<br />

4,5<br />

49


IN STRU MEN TA TION CA BLES<br />

50<br />

AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Suit able <strong>for</strong> Maxi Ter mipoint<br />

— Auto ma tion con nec tions<br />

— In stru men ta tion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2<br />

Instru men ta ti on cab le<br />

NO MAK ®<br />

IDEN TI FI CA TION<br />

Pairs marked with num bers,<br />

a- conductors are or ange <strong>and</strong> b- conductors are white.<br />

Over all shield Plas tic/alu min ium tape with earth<br />

con duc tor<br />

Shealth Grey LINYL- PVC<br />

2 x 2 x 0,5 4 x 2 x 0,5 8 x 2 x 0,5 12 x 2 x 0,5 24 x 2 x 0,5 48 x 2 x 0,5<br />

EAN code (SSTL code) 64 100+ 02 649 52-9 02 649 54-3 02 649 58-1 02 649 62-8 02 649 64-2 02 649 68-0<br />

Nomi nal di ame ter mm 7,5 8,5 11,0 14,0 19,0 25,0<br />

Mass kg/km 60 85 150 210 400 720<br />

De liv ery length m 1000/200 1000/200 1000 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 90 85<br />

Im ped ance, 10 MHz Ω 100 ± 10 %<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Ve loc ity fac tor 0.60<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

NO MAK is also available as halo gen free (NOMAK- HF) ver sion. The right to al tera tions re served.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,5<br />

2,9


AP PLI CA TIONS<br />

— Fixed in door — Proc ess con trol<br />

in stal la tions — Suit able <strong>for</strong> Maxi Ter mipoint<br />

— Auto ma tion con nec tions<br />

— In stru men ta tions<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

NO MAK-E ®<br />

IN STRU MEN TA TION CA BLES<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

IDEN TI FI CA TION<br />

Pair a-wire b-wire Pair a-wire b-wire<br />

1 blue red 3 green brown<br />

2 grey yellow 4 white black<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x 2 x 0,5 4 x 2 x 0,5 8 x 2 x 0,5 12 x 2 x 0,5 24 x 2 x 0,5<br />

EAN code (SSTL code) 64 100+ 02 649 53-6 02 649 55-0 02 649 59-8 02 649 63-5 02 649 65-9<br />

Nomi nal di ame ter mm 7,5 8,5 11,0 14,0 19,0<br />

Mass kg/km 60 85 150 210 400<br />

De liv ery length m 1000 1000 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 81<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km 90 85<br />

Im ped ance, 10 MHz Ω 100 ± 10 %<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Ve loc ity fac tor 0.60<br />

Maxi mum volt age V 75<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

Every four -pair unit marked with a number tape.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Overall Plas tic/alu min ium tape with<br />

earth con duc tor shield<br />

Shealth Grey LINYL- PVC<br />

NOMAK-E is also available as halo gen free (NOMAK- E- HF) ver sion. The right to al tera tions re served.<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,5<br />

2,9<br />

51


IN STRU MEN TA TION CA BLES<br />

52<br />

AP PLI CA TIONS<br />

Automation/ Istru men ta ti on cab les<br />

FKAR-PG n x 2 x 0,5 mm 2<br />

— In door — Proc ess con trol<br />

in stal la tions — Auto ma tion<br />

— In stru men ta tion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –30 °C<br />

- During installation -5 °C<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per 0,5 mm 2<br />

In su la tion Black PVC<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

STANDARD<br />

SS 4240323<br />

SS 4241475 Class 3, (Flame re tar dant).<br />

IDEN TI FI CA TION<br />

Insulation colour: black<br />

Each conductor with white number marking<br />

Over all shield Plas tic/alu min ium foil with drain<br />

wire<br />

Shealth Grey PVC<br />

Type 1 x 2 x 0,5 2 x 2 x 0,5 4 x 2 x 0,5 8 x 2 x 0,5 16 x 2 x 0,5 24 x 2 x 0,5 48 x 2 x 0,5<br />

Nomi nal di ame ter mm 6,0 9,0 10,5 14,0 18,0 21,5 29,0<br />

Mass kg/km 56 88 125 210 370 520 980<br />

ELEC TRI CAL PROP ER TIES<br />

Maxi mum loop re sis tance Ω/km 81<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Maxi mum volt age V 150/ 250<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 9,6 kHz<br />

fre quency 19,2 kHz<br />

0,4<br />

0,6


AP PLI CA TIONS<br />

— Fixed in door — In stru men ta tion<br />

in stal la tions — Auto ma tion<br />

Suit able <strong>for</strong> long dis tance trans mis sion.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Instru men ta ti on cab le<br />

KLAM 3 x 1,5 + 1,5<br />

IDEN TI FI CA TION<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 3 x 1,5+1,5<br />

EAN code (SSTL code) 64 100+ 02 640 03-8<br />

Nomi nal di ame ter mm 8,5<br />

Mass kg/km 115<br />

De liv ery length m 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 24<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

IN STRU MEN TA TION CA BLES<br />

a- conductor is blue, b- conductor is red <strong>and</strong><br />

c- conductor is white.<br />

The cable ful fils the fire con di tion re quire ments of<br />

IEC 332-1 (Flame re tar dant).<br />

Unit Twisted con duc tors shielded with<br />

plas tic/alu min ium tape, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

KLAM is also available as halo gen free (KLAM- HF) ver sion. The right to al tera tions re served.<br />

53


IN STRU MEN TA TION CA BLES<br />

54<br />

APPLICATION<br />

These symmetrical data transmission cables are used in<br />

control <strong>and</strong> supervision centres <strong>for</strong> industrial units. They<br />

are suitable <strong>for</strong> fixed installation inside housing. <strong>Cables</strong><br />

with rein<strong>for</strong>ced or douple outer sheath can be installed<br />

also outdoors <strong>for</strong> direct burial.<br />

CONSTRUCTION<br />

Multi-wired conductor or plain copper adapted to<br />

Maxi-Termi-Point connection; conductor insulation<br />

consists of PVC or halogen free material. Cores ar twisted<br />

to pairs with short loops inside a unit featuring good<br />

nearend crosstalk attenuation. Overall shielding of either<br />

aluminium laminated plastic foil or copper braid prevents<br />

EMC interference.<br />

IDENTIFICATION<br />

Conductors<br />

Pair no.<br />

Every unit with number coding<br />

Sheath colours<br />

Grey, resp. Blue <strong>for</strong> intrinsic safe systems at inhouse<br />

application; black <strong>for</strong> outdoor installation<br />

Sheath printing<br />

Manufacturer, type coding including conductor dimension<br />

<strong>and</strong> number of pairs, metre marking<br />

Symmetrical data transmission cables<br />

RD-<br />

Color<br />

a-conductor a-conductor<br />

1 blue red<br />

2 grey yellow<br />

3 green brown<br />

4 white black<br />

Cable description<br />

RD Y (St) Y n x 2 x 0,5<br />

number of pairs x conductor cross<br />

section<br />

Y outer sheath PVC (+70 °C)<br />

Yv rein<strong>for</strong>ced outer sheath PVC<br />

<strong>for</strong> direct burial<br />

Yw outer sheath heat resistant<br />

PVC (+90 °C)<br />

Yu outer sheath flame retardent PVC<br />

(LOI s30), IEC 332-1<br />

YuFR outer sheath fire retardent PVC<br />

(LOI s30), IEC 332-3C<br />

H outer sheath halogen free,<br />

IEC 332-3C<br />

St static shielding (foil)<br />

C copper braid shielding<br />

Y conductor insulation PVC (+70 °C)<br />

Yw conductor insulation heat resistant<br />

PVC (+90 °C)<br />

H conductor insulation halogen free<br />

R “Rechnerkabel”<br />

(str<strong>and</strong>ing min. 20 loops/m)<br />

D DECONTIC<br />

(registered trade mark of ABB)<br />

Also available<br />

RD-Y(St)Y with PVC outer sheath<br />

RD-Y(St)Yu with special flame retardent PVC<br />

outer sheath<br />

RD-H(St)H with halogen free outer sheath<br />

RD-Yw(C)Yw with heat resistant PVC outer sheath<br />

<strong>and</strong> braided copper


AP PLI CA TIONS<br />

Fixed installation inside housing<br />

Maxi mum ambient tem pera ture:<br />

- in operating -40 °C ...+70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Fire behaviour:<br />

oxygen index LOI acc. To ASTM-D-2863 no limit<br />

smoke density acc. To ASTM-D-2843 90 %<br />

HCL emission acc. To IEC 754-1 >25 %<br />

fire propagation acc. To IEC 332-1<br />

CON STRUC TION<br />

Con duc tor plain copper wire,<br />

0,5 mm 2 /7x0,3 mm 2 Ø)<br />

In su la tion PVC, Ø 1,5 mm<br />

Str<strong>and</strong>ing 2 conductors per pair<br />

CA BLE SIZES<br />

Symmetrical data transmission cables<br />

RD-Y(St)Y<br />

IDEN TI FI CA TION<br />

Core str<strong>and</strong>ing (0+4)<br />

Shielding Al-laminated plastic foil +<br />

drain wire 0,5 mm 2<br />

Outer shealth PVC<br />

Pert. no C17582000 C17582100 C17582200 C17582300 C17582400 C17582500 C17582600 C17582700 C17582800<br />

Type 2x2x0,5 4x2x0,5 8x2x0,5 12x2x0,5 16x2x0,5 24x2x0,5 32x2x0,5 48x2x0,5 96x2x0,5<br />

Outer di ame ter mm 6,5 ± 0,5 9,0 ± 0,5 11,5 ± 0,5 13,0 ± 0,8 14,5 ± 0,8 17,5 ± 1,0 20,0 ± 1,0 24,0 ± 1,0 32,5 ± 1,5<br />

Mass kg/km 65 110 190 240 300 420 570 800 1500<br />

Cu-content 25 45 85 125 165 245 325 485 965<br />

Bending radius mm 50 70 90 100 110 135 150 180 250<br />

De liv ery length m 4000 2000 2000 2000 2000 2000 2000 1000 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 73,6<br />

Nomi nal mu tual ca paci tance<br />

(800 Hz) nF/km<br />

4x2 nF/km<br />

Mini mum in su la tion re sis tance MΩ x km 100<br />

Nominal impedance<br />

(at 1 kHz) Ω<br />

(at 1 kHz) Ω<br />

Maxi mum volt age V 600<br />

Test voltage (at 50 Hz, 2 min)<br />

cond./conductor V<br />

cond./shield<br />

Nomi nal at tenua tion dB/100 m<br />

fre quency 1,0 kHz<br />

fre quency 10,0 kHz<br />

Pair no.<br />

100<br />

120<br />

370<br />

130<br />

2000<br />

2000<br />

1,2<br />

3,0<br />

IN STRU MEN TA TION CA BLES<br />

Color<br />

a-conductor a-conductor<br />

1 blue red<br />

2 grey yellow<br />

3 green brown<br />

Every unit with number coding<br />

The right to al tera tions re served.<br />

55


IN STRU MEN TA TION CA BLES<br />

56<br />

JA MAK ® & JA MAK ® ARM<br />

JOIN TING<br />

Pair shields <strong>and</strong> the com mon shield are spliced <strong>and</strong><br />

earthed by a cop per con duc tor. It is im por tant in the<br />

joint ing <strong>and</strong> ter mi nal con nec tions that the pair shields are<br />

in su lated one from<br />

the an other, ex cept <strong>for</strong> the com mon ground ing point.<br />

If the joint ing has to be EMC pro tected, the shields have to<br />

be jointed all around i.e. 360°.<br />

SPLIC ING<br />

1. The sheath is stripped. The in ner sheath is pulled<br />

open by the tear- off wire.<br />

2. The pair shield is opened <strong>and</strong> re moved<br />

1<br />

1<br />

1<br />

pull off<br />

1<br />

3. Splic ing of a pair<br />

pair sleeve<br />

2-12 pair<br />

25<br />

30<br />

50 40<br />

24 <strong>and</strong> 48 pairs<br />

2. cut<br />

1. cut<br />

earth conductor<br />

1<br />

2<br />

strip<br />

100<br />

1<br />

3<br />

1<br />

2<br />

1<br />

2<br />

1<br />

3 3<br />

2<br />

4 4<br />

3<br />

2<br />

4<br />

3<br />

4<br />

4<br />

1<br />

1<br />

1<br />

conductor sleeve<br />

joint gap<br />

1 1 1 1<br />

An in door ca ble is jointed with out steps 6 <strong>and</strong> 7.<br />

1<br />

1<br />

1 1<br />

The length of the splice de pends on the number of<br />

the pairs:<br />

Number of pairs 2 4 8 12 24 48<br />

Joint gap mm 280 280 280 280 400 400<br />

4. Splic ing of the earth con duc tor of the pair shield<br />

5. Com plete pair joint<br />

pair insulation<br />

Note! If the joint ing has to be EMC pro tected,<br />

the shields have to be jointed all around i.e. 360°.<br />

6. Splic ing of the in ner sheath<br />

7. Splic ing of the ar mour ing<br />

8. Com plete joint<br />

earth conductor splice<br />

1 1 1 1 1<br />

thermal protection earth conductor splice <strong>for</strong><br />

the common shield<br />

copper braid<br />

shrink-on tube<br />

soldering<br />

outer shrink-on tube inner shrink-on tube<br />

shrink-on tube<br />

The right to al tera tions re served.


DISTRIBUTED DATA SYS TEMS OF<br />

BUIL DING TECH NO LOGY<br />

LON (Lo cal Op er at ing Net work)<br />

- LON is field bus that en ables the distributed data<br />

sys tems in build ings<br />

- based on the Neuron- prosessor of Eche lon Co<br />

- cho sen by the Fin nish build ing as so cia tion as<br />

the ba sis of SaMBA- project<br />

- LON is a build ing auto ma tion sys tem which con trols<br />

lights, heat ing, air con di tion ing, elec tric ity, se cu rity<br />

sys tems of build ings with in tel li gent auto ma tion sys tems<br />

- LON- net/In tel li gent nodes. They use the same lan guage,<br />

which is Lon Talk. LON- bus is open <strong>and</strong> suit able <strong>for</strong><br />

prod ucts of dif fer ent manu fac turers<br />

- LON- net does not need cen tral ized con trol<br />

- Ap pli ca tions are build ings, in dus try <strong>and</strong> pro cess<br />

auto ma tion, ve hi cles <strong>and</strong> small sys tems<br />

- Lon Works networks is becoming the dominant st<strong>and</strong>art<br />

<strong>for</strong> home networking around the world.<br />

It is very im por tant to plan ca bling sys tems so that it is<br />

pos si ble to con nect in tel li gent switches <strong>and</strong> nodes eas ily<br />

<strong>and</strong> make so lu tions which work prop erly in the fu ture too.<br />

The LON ca bles of NK Ca bles ful fil re quire ments of<br />

Echelon specification, which describes ca bling sys tems<br />

<strong>and</strong> re quire ments.<br />

LON<br />

4-way breakout box<br />

The last outlet includes terminating resistor<br />

RJ 45-female connector<br />

LON-outlet<br />

Connection cable<br />

RJ 45 - RJ 45<br />

LON- Cabling<br />

LON -Ca bling can be realized with three dif fer ent con duc tor<br />

sizes (1,3 mm, 0,8 mm <strong>and</strong> 0,65 mm).<br />

LON- cables of NK Ca bles are:<br />

LO NAK ®<br />

2 x 1,3<br />

LO NAK ® ARM 2 x 1,3<br />

LO NAK ® 2 x 2 x 0,8<br />

LO NAK ®<br />

2 x 2 x 0,65<br />

LON Ca bling works also with Cat. 5 ca bles, but only with<br />

shorter con nec tions <strong>and</strong> smaller node amounts.<br />

Readiness of LON- Cabling<br />

Readiness <strong>for</strong> LON can be improved by installing<br />

a sufficient amount of LON boxes with RJ 45 female<br />

connectors to connect the nodes.<br />

LON outlets should be installed in such amounts <strong>and</strong> at<br />

such distances that a allow a readiness <strong>for</strong> LON in all<br />

premises can be achieved.<br />

The type of cable used as a connecting wire <strong>and</strong> its lenght<br />

should be chosen according to the tranceivers <strong>and</strong> in<br />

compliance with the allowed lengths of cable <strong>and</strong><br />

distances between nodes.<br />

Cabling implemented in the right way is a basic<br />

prerequisite <strong>for</strong> error-free <strong>and</strong> reliable data transmission<br />

between intelligent nodes. Cabling has a great effect on<br />

how the LON network will serve its users in the future when<br />

it is need to change <strong>and</strong> grow.<br />

Implementation of LON- Cabling<br />

LON-pair<br />

0,65 mm cable<br />

1 2 3 4 5 6 7 8<br />

Connection cable<br />

RJ 45 - screw connection<br />

LON CABLING<br />

57


SIGNAL CABLES<br />

58<br />

Buil ding au to ma ti on cab le<br />

LO NAK 2 x 1,3 <strong>and</strong> LONAK ARM 2 x 1,3<br />

AP PLI CA TIONS<br />

— LONAK: Fixed in door — LONAK ARM: Outdoor<br />

in stal la tions installations<br />

— LON net ca bling — Build ing auto ma tion<br />

ca bling<br />

De signed spe cially <strong>for</strong> LON net work ca bling sys tems.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

LONAK 2 x 1,3<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

Sheath Grey LINYL- PVC<br />

Sheath NK CABLES LO NAK 2 x 1,3<br />

mark ing trace abil ity code, me tre mark ing<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x 1,3 2 x 1,3<br />

EAN code (SSTL code) 64 100+ 02 649 20-8 02 649 30-7<br />

Nomi nal di ame ter mm 7,0 10,5<br />

Mass kg/km 65 155<br />

De liv ery length m 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 28 28<br />

Nomi nal mu tual ca paci tance nF/km 72 72<br />

Nomi nal im ped ance Ω 82<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion: 130 N<br />

IDEN TI FI CA TION<br />

a- conductor is white, b- conductor is blue<br />

The LONAK ca ble fulfils the fire con di tion re quire ments<br />

of IEC 332-1.<br />

LONAK ARM 2 x 1,3<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted pair<br />

Sheath Grey PVC<br />

Ar mour ing Heli cally wrapped steel b<strong>and</strong>s<br />

Outersheath Black PE<br />

Mini mum in su la tion re sis tance MΩ x km 100 100<br />

Veloci ty fac tor 0,55 0,55<br />

Maxi mum volt age V 75 75<br />

LO NAK is also available as halo gen free LONAK- HF ver sion. LO NAK ARM is also available as halo gen free LO NAK ARM- HF ver sion.<br />

N


AP PLI CA TIONS<br />

Buil ding au to ma ti on cab le<br />

LO NAK 2 x 2 x 0,8 <strong>and</strong><br />

LONAK 2 x 2 x 0,65<br />

— 2 x 2 x 0,8: Fixed in door — 2 x 2 x 0,65: Outin<br />

stal la tions door installations<br />

— LON net ca bling — Build ing auto ma tion<br />

ca bling<br />

De signed spe cially <strong>for</strong> LON net work ca bling sys tems.<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

LONAK 2 x 2 x 0,8<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

Unit Twisted pair<br />

Shield Aluminium tape <strong>and</strong> earth conductor<br />

Sheath Grey LINYL- PVC<br />

CA BLE SIZES<br />

LO NAK 2 x 2 x 0,8 is also available as halo gen free LONAK- HF ver sion.<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

2 x 2 x 0,8 100 N<br />

2 x 2 x 0,65 65 N<br />

IDEN TI FI CA TION<br />

Pair Con duc tor<br />

1 white / blue<br />

2 white / orange<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.<br />

LONAK 2 x 2 x 0,65<br />

Con duc tor Tinned cop per<br />

In su la tion PE<br />

Unit Twisted pair<br />

Shield Alu min ium tape <strong>and</strong> earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> diameter of<br />

the con duc tors mm 2 x 2 x 0,8 2 x 2 x 0,65<br />

EAN code (SSTL code) 64 100+ 02 649 38-3 02 649 36-9<br />

Nomi nal di ame ter mm 6,5 4,5<br />

Mass kg/km 58 32<br />

De liv ery length m 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum loop re sis tance Ω/km 73 106<br />

Nomi nal mu tual ca paci tance nF/km 98 49<br />

Mini mum in su la tion re sis tance MΩ x km 100 100<br />

Ve loc ity fac tor 0,55 0,67<br />

Re sis tance un bal ance, max % 3<br />

Max. ca paci tance un bal ance pF/m 1600<br />

Maxi mum volt age V 75 75<br />

N<br />

SIGNAL CABLES<br />

The right to al tera tions re served.<br />

59


SIGNAL CABLES<br />

60<br />

AP PLI CA TIONS<br />

— Fixed in door — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2751<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Sig nal cab le<br />

KLM<br />

Unit In su lated con duc tors twisted to gether<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> di ame ter of<br />

the con duc tors mm 2 x 0,8 4 x 0,8<br />

EAN code (SSTL code) 64 100+ 02 910 01-8 02 910 03-2<br />

Nomi nal di ame ters mm 4,5 5,0<br />

Mass kg/km 25 40<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

KLM is also available as halo gen free KLM- HF ver sion.<br />

IDEN TI FI CA TION<br />

1. Conductor blue<br />

2. Conductor yel low<br />

3. Conductor white<br />

4. Conductor red<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.


AP PLI CA TIONS<br />

— Fixed in door — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2755<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Sig nal cab le<br />

KLMA<br />

Num ber <strong>and</strong> di ame ter of<br />

the con duc tors mm 2 x 0,8+0,8 4 x 0,8+0,8<br />

EAN code (STTL code) 64 100+ 02 920 01-7 02 920 03-1<br />

Nomi nal di ame ters mm 4,5 5,0<br />

Mass kg/km 30 45<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

KLMA is also available as halo gen free KLMA- HF ver sion.<br />

IDEN TI FI CA TION<br />

1. Conductor blue<br />

2. Conductor yel low<br />

3. Conductor white<br />

4. Conductor red<br />

SIG NAL CA BLES<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.<br />

Unit Twisted con duc tors shielded with<br />

plas tic-alu min ium tape, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

The right to al tera tions re served.<br />

61


SIG NAL CA BLES<br />

62<br />

AP PLI CA TIONS<br />

— Fixed in door — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2752<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

CA BLE SIZES<br />

Fire alarm cab le<br />

MMSA<br />

IDEN TI FI CA TION<br />

Num ber<br />

in con cen tric<br />

layer<br />

1<br />

2, 5, 8 ...<br />

3, 6, 9...<br />

4, 7, 10<br />

last<br />

Con duc tors Str<strong>and</strong> ing<br />

Col our Type Make- up<br />

Blue<br />

(mark col our)<br />

yellow<br />

white<br />

brown<br />

red<br />

(direction<br />

indication)<br />

Num ber <strong>and</strong> di ame ter of<br />

the con duc tors mm 4 x 0,8+0,8 12 x 0,8+0,8 20 x 0,8+0,8<br />

EAN code (SSTL code) 64 100+ 02 630 70-1 02 630 72-5 02 630 74-9<br />

Nomi nal di ame ters mm 5,5 8,5 10,0<br />

Mass kg/km 45 115 180<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

4x<br />

12x<br />

20x<br />

0+4<br />

3+9<br />

1+7+12<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.<br />

Earth shield Aluminium tape on insulated conductor<br />

Str<strong>and</strong>ing Twisted con duc tors, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

The right to al tera tions re served.


AP PLI CA TIONS<br />

— Fixed outdoor — Alarm, sig nal <strong>and</strong><br />

in stal la tions se cu rity con trol<br />

— Build ing auto ma tion trans mis sion<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 15xD<br />

- during operation 10xD<br />

CON STRUC TION<br />

Ac cord ing to SFS 2752<br />

Con duc tor Tinned cop per<br />

In su la tion PVC<br />

Earth shield Aluminium tape on insulated conductor<br />

CA BLE SIZES<br />

Fire alarm cab le<br />

MMVDMA (MMPMA)<br />

IDEN TI FI CA TION<br />

Num ber<br />

in con cen tric<br />

layer<br />

1<br />

2, 5, 8 ...<br />

3, 6, 9...<br />

4, 7, 10<br />

last<br />

Con duc tors Str<strong>and</strong> ing<br />

Col our Type Make- up<br />

Blue<br />

(mark colour)<br />

yellow<br />

white<br />

brown<br />

red<br />

(direction<br />

indication)<br />

Str<strong>and</strong>ing Twisted con duc tors, earth con duc tor<br />

Sheath Grey LINYL- PVC<br />

Ar mour ing Steel wire ar mour ing<br />

Outersheath Black PVC<br />

Num ber <strong>and</strong> di ame ter of<br />

con duc tors mm 4 x 0,8+0,8 12 x 0,8+0,8 20 x 0,8+0,8<br />

EAN code (SSTL code) 64 100+ 02 633 00-9 02 633 02-3 02 633 04-7<br />

Nomi nal di ame ters mm 11,5 15,0 17,5<br />

Mass kg/km 230 390 520<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

MMVDMA<br />

MMPMA<br />

Maxi mum con duc tor re sis tance Ω/km 36,7<br />

Mini mum in su la tion re sis tance MΩ x km 500<br />

Maxi mum volt age V 75<br />

SIGNAL CA BLES<br />

4x<br />

12x<br />

20x<br />

0+4<br />

3+9<br />

1+7+12<br />

The right to al tera tions re served.<br />

63


DATA CA BLES<br />

64<br />

GEN ERAL<br />

GE NE RIC CAB LING SYS TEMS<br />

Generic cabling is applied to telecommunication cabling<br />

as a permanent part of the office to meet the exp<strong>and</strong>ing<br />

needs of the user’s. It meets also the future data<br />

transmission requirements including new computers <strong>and</strong><br />

relocation of the workstations on the premises<br />

- minimizing the need <strong>for</strong> new cabling.<br />

The physical structure of a generic cabling system is<br />

star-shaped. This makes the network control easier which<br />

is important especially now when the telecommunication<br />

<strong>and</strong> data networks in buildings are the property of<br />

the owner. A star-shape cable system allows to change<br />

the network topology from the cross-connection to a bus<br />

or a ring. In a star-shape system all the active components<br />

can be placed together in one space which is easy to<br />

control <strong>and</strong> can be locked <strong>and</strong> which improves data<br />

security. Also measurements <strong>and</strong> maintenance are easier<br />

to carry out in the cross-connection area. lf one branch of<br />

the star network falls off the whole system is not paralyzed<br />

because the faulty branch can be disconnected from the<br />

network.<br />

The generic cabling system is not really open until its<br />

components are vendorindependent. They just have to<br />

con<strong>for</strong>m to the st<strong>and</strong>ards. When planning a cable system<br />

it is important to consider what the openness really means<br />

<strong>and</strong> how open the non-compatible <strong>and</strong> vendor-dependent<br />

cable systems are.<br />

STAN DARDS<br />

The European st<strong>and</strong>ard <strong>for</strong> the generic cabling systems<br />

is EN 50173 which was set up on the basis of the<br />

international ISO/IEC 11801. The corresponding st<strong>and</strong>ard<br />

in the U.S. is ANSI/TIA/EIA 568-A supported by TIA <strong>and</strong><br />

EIA. The EN 50173 applicable in Europe defines the<br />

different transmission line applications <strong>and</strong> classes as well<br />

as the categories 3 <strong>and</strong> 5 <strong>for</strong> the line components.<br />

For example, a data network that fulfills the requirements<br />

of class D can be set up from components of category 5.<br />

EN 50173 recommends the use of 100 Ω twisted-pair<br />

cables in horizontal cabling.<br />

Cat. 6 st<strong>and</strong>ard will be ready in 2001.<br />

SCREENING<br />

The abbreviations UTP, FTP <strong>and</strong> STP-screening<br />

construction are used to refer to the cable. UTP is a cable<br />

where symmetrical twisted pairs are used <strong>for</strong> screening.<br />

A FTP cable has an overall metal shield, <strong>and</strong> in a STP<br />

cable all the pairs are screened separately. The cable type<br />

is chosen to suit the environment where it’s used.<br />

In Finl<strong>and</strong> most of the installations are made with FTP <strong>and</strong><br />

UTP cables. Optical fibre cables are recommended <strong>for</strong><br />

local <strong>and</strong> rising cabling.<br />

The STP may also be marked ScTP <strong>and</strong> S/STP, meaning<br />

a construction with a pair <strong>and</strong> an overall shield.<br />

AP PLI CA TION AND TRANS MIS SION<br />

CLASSES<br />

Transmission<br />

classes<br />

A<br />

B<br />

C<br />

D<br />

Application Maximum<br />

frequency<br />

Voice b<strong>and</strong> <strong>and</strong><br />

low-frequency<br />

applications<br />

100 kHz<br />

Medium-speed<br />

data applications 1 MHz<br />

Fast data<br />

applications 16 MHz<br />

Very fast data<br />

applications 100 MHz<br />

E Very fast data<br />

applications 200 MHz<br />

OPTICAL<br />

Very fast data<br />

applications<br />

A ge neric ca bling sys tem con structed <strong>for</strong> a cer tain<br />

ap pli ca tion con sists of one or sev eral trans mis sion lines.<br />

REC OM MEN DA TIONS<br />

— It is important to examine the building needs very<br />

carefully, including e.g. the existing network <strong>and</strong><br />

the desires <strong>for</strong> more extended data transmission<br />

in the future.<br />

— The maximum length of horizontal cabling is 90 m.<br />

The maximum length of cross-connection <strong>and</strong><br />

equipment cabling is 10 m.<br />

— An optical fibre cable is recommended <strong>for</strong> local <strong>and</strong><br />

rising cabling.<br />

— Two double cables should be installed <strong>for</strong> each work<br />

area, in order to meet the increasing need of<br />

telecommunication.<br />

DATA TRANSMISSION CABLES<br />

Our complete range of UC cables fulfills tomorrow’s<br />

needs. Our new product family UC 400 is designed <strong>for</strong><br />

applications beyond CAT 5 with good properties.<br />

Our new development <strong>for</strong> the high-end field is UC 1000.<br />

A cable class that not only fulfills the above mentioned<br />

st<strong>and</strong>ards, but also offers reserves, allowing base b<strong>and</strong><br />

transmission of Gigabit-Ethernet.<br />

_


GE NERIC CA BLING CON STRUC TION<br />

Building distributor<br />

Building backbone cabling<br />

Floor distributor<br />

Horizontal cabling<br />

FD<br />

Telecommunication outlets<br />

CONTENTS<br />

Campus distributor<br />

Campus backbone cabling<br />

CD<br />

BD BD<br />

BD<br />

FD FD<br />

TO TO TO TO TO TO<br />

ATM<br />

DATA CA BLES<br />

FD<br />

ATM, or the Asynchronous Transfer Mode, is a network<br />

technology which use is very rapidly increasing. ATM can<br />

be used to transfer sound, picture <strong>and</strong> data. ATM is based<br />

on data transfer with cells of the same size which reserve<br />

the line only <strong>for</strong> the duration of the actual transmission.<br />

MEAN ING OF THE SYM BOLS<br />

UC = Uni ver sal Ca ble<br />

300 = Maxi mum fre quency 300 MHz,<br />

fast data ap pli ca tions<br />

400, 600 = Maxi mum fre quency 400, 600 MHz,<br />

fast data ap pli ca tions<br />

S = Screen alu min ium shield<br />

D = Dou ble<br />

SS = Su per Screen pair foil screen<br />

with com mon braid<br />

24 = AWG- number<br />

di ame ter of con duc tor 0,51 mm<br />

22 = AWG- number<br />

di ame ter of con duc tor 0,64 mm<br />

4 P = four pair<br />

2 x 4 P = Dou ble<br />

FRNC = Halogen- free ma te rial<br />

Ex am ple. UC 300 D S 24 2x4 P<br />

UC = Uni ver sal Ca ble,<br />

300 = Maxi mum fre quency 300 MHz,<br />

fast data ap pli ca tions<br />

D = Dou ble<br />

S = Screen alu min ium shield<br />

24 = AWG- number<br />

di ame ter of con duc tor 0,51 mm<br />

2 x 4 P = Dou ble<br />

65


DATA CA BLES<br />

66<br />

GE NERIC CA BLING CA BLE TYPE<br />

HORIZONTAL<br />

CABLING<br />

BUILDING<br />

BACKBONE<br />

CABLING<br />

Cable type<br />

THE COL OUR SYS TEM OF THE<br />

CON DUC TORS<br />

NK Ca bles rec om mend that the con duc tors of UC 300<br />

ca bles could be con nected as fol lows:<br />

Pair a b<br />

1 white blue<br />

2 white or ange<br />

3 white green<br />

4 white brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

Design/protection against<br />

electromagnetic<br />

disturbancies<br />

UC 300 S 24 4P FTP<br />

Overall shield 100/125<br />

UC 300 DS 24 2 x 4P FTP<br />

Overall shield<br />

Shotgun version<br />

UC 300 24 4P UTP<br />

UC 300 D 24 2 x 4P UTP<br />

Shotgun version<br />

UC 400 24 4P<br />

High<br />

Per<strong>for</strong>mance UTP<br />

UC 400 D 24 2 x 4P High<br />

Per<strong>for</strong>mance UTP<br />

Shotgun version<br />

UC 400 S 24 2 x 4P<br />

High<br />

Per<strong>for</strong>mance FTP<br />

UC 400 DS 24 2 x 4P High<br />

Per<strong>for</strong>mance FTP<br />

Shotgun version<br />

Frequency, max. MHz Classification<br />

EN 50173<br />

100/125<br />

200/250<br />

200/250<br />

UC 600 SS 23 4P Overall shield<br />

Screened pair 600<br />

UC 1000 SS 22 4P<br />

FYMSU n x 62.5/125<br />

(Spiral Space ® )<br />

S/STP<br />

Fibre optic cable<br />

CONTENTS<br />

1000<br />

Category 5/5e<br />

Category 5/5e<br />

Category 5/5e<br />

Category 5/5e<br />

Cat 6<br />

Cat 6<br />

Cat 7<br />

Application<br />

Telephone network<br />

ISDN<br />

Ethernet 10, 100 Mbit/s<br />

Token Ring 4/16 Mbit/s<br />

CDDI /TP-PMD<br />

ATM<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Gigabit-Ethernet<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Gigabit-Ethernet<br />

Tele phone net work<br />

ISDN<br />

Eth er net 100 Mbit/s<br />

To ken Ring 4/16 Mbit/s<br />

CDDI /TP- PMD<br />

ATM<br />

Gigabit-Ethernet<br />

ISDN<br />

Ethernet 10 Mbit/s<br />

Token Ring 4/16 Mbit/s<br />

CDDI /TP-PMD<br />

ATM<br />

Gigabit-Ethernet<br />

The stan dard does not de fine the col our sys tems but, <strong>for</strong><br />

rea sons of con <strong>for</strong> mity, the above sys tem is rec om mended.


CONTENTS<br />

All these new UC- cables have been tested by the EC group of Delta, <strong>and</strong> here is an example of a statement on UC 300 S.<br />

DATA CA BLES<br />

67


DATA CA BLES<br />

68<br />

Data cab le, category 5, FTP<br />

UC 300 S 24 4P / UC 300 DS 24 2 x 4P<br />

N<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — To ken Ring 4/16 Mbit/s<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 300 S 24 4P 80 N<br />

UC 300 DS 24 2 x 4P 160 N<br />

STAN DARDS<br />

EN 50173; prEN 50288-3-1<br />

ISO/IEC 11801 2 rd ed<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 100 base T<br />

IDEN TI FI CA TION<br />

UC 300 S 24 4P is available as halogenfree UC 300 DS 24 2 x 4P- FRNC-B/C version.<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.


DATA CA BLES<br />

Data cab le,category 5, FTP<br />

UC 300 S 24 4P / UC 300 DS 24 2 x 4P<br />

CON STRUC TION<br />

Con duc tor Cop per wire, d = 0,51 mm<br />

In su la tion PE<br />

Unit Twisted pair<br />

Earth wire Tinned cop per<br />

CA BLE SIZES<br />

Type UC 300 S 24 4P UC 300 DS 24 2 x 4P<br />

EAN code (STTL code) 64 100+ 02 640 01 02 640 64<br />

Nomi nal di ame ters mm 5,8 5,8 x 11,6<br />

Mass kg/km 36 72<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re cis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />

Maxi mum trans fer im ped ance MΩ x m 100<br />

Ve loc ity fac tor 0,67<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 5e (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,9<br />

6,3<br />

8,0<br />

9,0<br />

11,4<br />

16,5<br />

21,3<br />

1,9<br />

3,7<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,7<br />

19,8<br />

22,3<br />

24,2<br />

25,7<br />

27,5<br />

29,2<br />

32,0<br />

65<br />

56<br />

50<br />

47<br />

46<br />

43<br />

38<br />

35<br />

71<br />

62<br />

56<br />

53<br />

51<br />

49<br />

40<br />

41<br />

40<br />

38<br />

37<br />

36<br />

35<br />

34<br />

62<br />

53<br />

47<br />

44<br />

43<br />

40<br />

35<br />

32<br />

68<br />

59<br />

53<br />

50<br />

48<br />

46<br />

41<br />

38<br />

37<br />

35<br />

34<br />

33<br />

32<br />

31<br />

Screen Plas tic/alu min ium tape as a over all<br />

shield<br />

Sheath Grey PVC<br />

63,3<br />

52,4<br />

44,0<br />

39,3<br />

36,8<br />

31,5<br />

21,9<br />

14,0<br />

69,1<br />

58,3<br />

50,0<br />

45,3<br />

43,0<br />

37,9<br />

28,4<br />

21,2<br />

17,2<br />

13,9<br />

11,6<br />

9,0<br />

5,8<br />

1,8<br />

60,3<br />

49,4<br />

41,0<br />

36,3<br />

33,8<br />

28,5<br />

18,9<br />

11,0<br />

66,1<br />

55,3<br />

47,0<br />

42,3<br />

40,0<br />

34,9<br />

25,4<br />

18,2<br />

14,2<br />

10,9<br />

8,6<br />

6,0<br />

2.8<br />

-1,2<br />

64<br />

52<br />

44<br />

40<br />

38<br />

34<br />

28<br />

24<br />

68<br />

56<br />

48<br />

44<br />

42<br />

38<br />

32<br />

28<br />

26<br />

24<br />

23<br />

22<br />

20<br />

16<br />

61<br />

49<br />

41<br />

37<br />

35<br />

31<br />

25<br />

21<br />

65<br />

53<br />

45<br />

41<br />

39<br />

35<br />

29<br />

25<br />

23<br />

21<br />

20<br />

19<br />

17<br />

13<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

The right to al tera tions re served.<br />

69


DATA CA BLES<br />

70<br />

N<br />

Data cab le, category 5, UTP<br />

UC 300 24 4P / UC 300 D 24 2 x 4P<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — To ken Ring 4/16 Mbit/s<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 300 24 4P 80 N<br />

UC 300 D 24 2 x 4P 160 N<br />

STAN DARDS<br />

UC 300 24 4P is available as halogenfree UC 300 D 24 2 x 4P- FRNC-B/C version.<br />

EN 50173; prEN 50288-3-1<br />

ISO/IEC 11801 2 rd ed<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 100 base T<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

On the a-wire there is a stripe of the same colour as<br />

the corresponding b-wire.<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-1.


Data cab le, category 5, UTP<br />

UC 300 24 4P / UC 300 D 24 2 x 4P<br />

CON STRUC TION<br />

Con duc tor Cop per wire, d = 0,51 mm<br />

In su la tion PE<br />

CA BLE SIZES<br />

Type UC 300 24 4P UC 300 D 24 2 x 4P<br />

EAN code (STTL code) 64 100+ 02 640 05 02 640 07<br />

Nomi nal di ame ters mm 5,0 5,0 x 10,0<br />

Mass kg/km 35 70<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re cis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 Mhz 100 ± 15<br />

Ve loc ity fac tor 0,67<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 5e (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

DATA CA BLES<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,9<br />

6,3<br />

8,0<br />

9,0<br />

11,4<br />

16,5<br />

21,3<br />

1,9<br />

3,7<br />

6,0<br />

7,6<br />

8,4<br />

10,7<br />

15,7<br />

19,8<br />

22,3<br />

24,2<br />

25,7<br />

27,5<br />

29,2<br />

32,0<br />

65<br />

56<br />

50<br />

47<br />

46<br />

43<br />

38<br />

35<br />

71<br />

62<br />

56<br />

53<br />

51<br />

49<br />

44<br />

41<br />

40<br />

38<br />

37<br />

36<br />

35<br />

34<br />

62<br />

53<br />

47<br />

44<br />

43<br />

40<br />

35<br />

32<br />

68<br />

59<br />

53<br />

50<br />

48<br />

46<br />

41<br />

38<br />

37<br />

35<br />

34<br />

33<br />

32<br />

31<br />

Unit Twisted pair<br />

Sheath Grey PVC<br />

63,3<br />

52,4<br />

44,0<br />

39,3<br />

36,8<br />

31,5<br />

21,9<br />

14,0<br />

69,1<br />

58,3<br />

50,0<br />

45,3<br />

43,0<br />

37,9<br />

28,4<br />

21,2<br />

17,2<br />

13,9<br />

11,6<br />

9,0<br />

5,8<br />

1,8<br />

60,3<br />

49,4<br />

41,0<br />

36,3<br />

33,8<br />

28,5<br />

18,9<br />

11,0<br />

66,1<br />

55,3<br />

47,0<br />

42,3<br />

40,0<br />

34,9<br />

25,4<br />

18,2<br />

14,2<br />

10,9<br />

8,6<br />

6,0<br />

2,8<br />

-1,2<br />

64<br />

52<br />

44<br />

40<br />

38<br />

34<br />

28<br />

24<br />

68<br />

56<br />

48<br />

44<br />

42<br />

38<br />

32<br />

28<br />

26<br />

24<br />

23<br />

22<br />

20<br />

16<br />

61<br />

49<br />

41<br />

37<br />

35<br />

31<br />

25<br />

21<br />

65<br />

53<br />

45<br />

41<br />

39<br />

35<br />

29<br />

25<br />

23<br />

21<br />

20<br />

19<br />

17<br />

13<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

The right to al tera tions re served.<br />

71


DATA CA BLES<br />

Data cab le, category 6, STP, Patented<br />

UC 400 S 23/1 4P/UC 400 DS 23/1 2x4P<br />

72<br />

N<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 10 Mbit/s, 100 Mbit/s<br />

in stal la tions — Gigabit- Ethernet<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 400 S 23/1 4P 100 N<br />

UC 400 DS 23/1 2 x 4P 200 N<br />

STAN DARDS<br />

UC 400 S 23/1 4P is available as halogenfree UC 400 S 24 4P- FRNC-B/C version.<br />

EN 50173-1; prEN 50288-5-1<br />

ISO/IEC 11801 2 nd edition<br />

TIA/EIA 568-B<br />

ISO 8802.3/IEEE 802.3 10 base T, 100 base T<br />

ISO 8802.5/IEEE 802.5<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The cable fulfils the fire condition requirements of<br />

IEC 332-1.<br />

Halogenfree cable fulfils the fire condition requirements<br />

of IEC 332-3


DATA CA BLES<br />

Data cab le, category 6, STP, Patented<br />

UC 400 S 23/1 4P/UC 400 DS 23/1 2x4P<br />

CON STRUC TION<br />

Conductor Copper wire, d=0,56 mm<br />

Insulation PE<br />

Unit Twisted pair<br />

CA BLE SIZES<br />

Type UC 400 S 23/1 4P UC 400 DS 23/1 2x4P<br />

EAN code (SSTL code) 64 100+ 02 640 75 02 640 76<br />

Nomi nal di ame ters mm 6,5 6,5/13,0<br />

Mass kg/km 41 82<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re sis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />

Trans fer imped ance, max mΩ/m 100<br />

Ve loc ity fac tor 0,78<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 6 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

400<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2,2<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,5<br />

19,9<br />

22,5<br />

25,4<br />

27,1<br />

29,2<br />

33,0<br />

2<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,1<br />

19,1<br />

21,3<br />

23,8<br />

25,3<br />

27,0<br />

32,6<br />

35,7<br />

41,2<br />

74<br />

65<br />

59<br />

56<br />

55<br />

52<br />

47<br />

44<br />

43<br />

42<br />

41<br />

40<br />

38<br />

87<br />

78<br />

72<br />

69<br />

68<br />

65<br />

60<br />

57<br />

56<br />

54<br />

53<br />

53<br />

51<br />

50<br />

48<br />

71<br />

62<br />

56<br />

53<br />

52<br />

49<br />

44<br />

41<br />

40<br />

39<br />

38<br />

37<br />

35<br />

84<br />

75<br />

69<br />

66<br />

65<br />

62<br />

57<br />

54<br />

53<br />

51<br />

50<br />

50<br />

48<br />

47<br />

45<br />

Earth wire Tinned copper<br />

Screen Special wrapping of Al laminated foil<br />

Sheath Blue PVC<br />

71,8<br />

61,2<br />

53,0<br />

48,4<br />

46,5<br />

41,3<br />

31,5<br />

24,1<br />

20,5<br />

16,6<br />

13,9<br />

10,8<br />

5,0<br />

85,0<br />

74,2<br />

66,0<br />

61,3<br />

59,0<br />

54,0<br />

45,0<br />

37,9<br />

34,2<br />

30,3<br />

28,1<br />

25,5<br />

18,5<br />

14,2<br />

6,8<br />

68,8<br />

58,2<br />

50,0<br />

45,4<br />

43,5<br />

38,3<br />

28,5<br />

21,1<br />

17,5<br />

13,6<br />

10,9<br />

7,8<br />

2,0<br />

82,0<br />

71,2<br />

63,0<br />

58,3<br />

56,0<br />

51,0<br />

42,0<br />

34,9<br />

31,2<br />

27,3<br />

25,1<br />

22,5<br />

15,5<br />

11,2<br />

3,8<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

19<br />

75<br />

75<br />

75<br />

71<br />

69<br />

65<br />

59<br />

55<br />

53<br />

51<br />

50<br />

49<br />

47<br />

45<br />

53<br />

64<br />

52<br />

44<br />

40<br />

38<br />

34<br />

28<br />

24<br />

22<br />

20<br />

19<br />

18<br />

16<br />

72<br />

72<br />

72<br />

68<br />

66<br />

62<br />

56<br />

52<br />

50<br />

48<br />

47<br />

46<br />

44<br />

42<br />

40<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

21<br />

21<br />

21<br />

19<br />

The right to al tera tions re served.<br />

73


DATA CA BLES<br />

74<br />

N<br />

Data cab le, category 6, UTP (4 x 2 x 0,56 / AWG 23)<br />

UC 400 24 4P/UC 400 D 24 2 x 4P<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 10 Mbit/s, 100 Mbit/s<br />

in stal la tions — Gigabit- Ethernet<br />

— CDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion:<br />

UC 400 24 4P 80 N<br />

UC 400 D 24 2 x 4P 160 N<br />

STAN DARDS<br />

UC 400 24 4P is available as halogenfree UC 400 D 24 2 x 4P- FRNC-B/C version.<br />

EN 50173; prEN 50288-6-1<br />

ISO/IEC 11801 2 nd edition<br />

TIA/EIA 568-A<br />

ISO 8802.3/IEEE 802.3 10 base T, 100 base T<br />

ISO 8802.5/IEEE 802.5<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The cable fulfils the fire condition requirements of<br />

IEC 332-1.<br />

Halogenfree cable fulfils the fire condition requirements<br />

of IEC 332-3


CA BLE SIZES<br />

Data cab le, category 6, UTP (4 x 2 x 0,56 / AWG 23)<br />

UC 400 24 4P/UC 400 D 24 2 x 4P<br />

CON STRUC TION<br />

Conductor Copper wire, d=0,56 mm<br />

Insulation PE<br />

Type UC 400 24 4P UC 400 D 24 2 x 4P<br />

EAN code (SSTL code) 64 100+ 02 640 71 02 640 72<br />

Nomi nal di ame ters mm 5,2 5,2/10,4<br />

Mass kg/km 35 70<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 176<br />

In su la tion re sis tance, min GΩ x km 2<br />

Nomi nal mu tual ca paci tance nF/km 48<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1500<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15<br />

Ve loc ity fac tor 0,78<br />

Maxi mum volt age V 75<br />

TRANSMISSION CHARACTERISTICS ACC. TO CATEGORY 6 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

400<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

DATA CA BLES<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2,0<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,5<br />

19,9<br />

22,5<br />

25,4<br />

27,1<br />

29,2<br />

33,0<br />

1,9<br />

3,8<br />

6,0<br />

7,6<br />

8,5<br />

10,7<br />

15,1<br />

19,1<br />

21,3<br />

23,8<br />

25,3<br />

27,0<br />

33,0<br />

36,1<br />

41,7<br />

74<br />

65<br />

59<br />

56<br />

55<br />

52<br />

47<br />

44<br />

43<br />

42<br />

41<br />

40<br />

38<br />

78<br />

69<br />

63<br />

60<br />

59<br />

56<br />

51<br />

48<br />

47<br />

45<br />

44<br />

44<br />

42<br />

41<br />

39<br />

71<br />

62<br />

56<br />

53<br />

52<br />

49<br />

44<br />

41<br />

40<br />

39<br />

38<br />

37<br />

36<br />

75<br />

66<br />

60<br />

57<br />

56<br />

53<br />

48<br />

45<br />

44<br />

42<br />

41<br />

41<br />

39<br />

38<br />

36<br />

Unit Twisted pair<br />

Sheath Blue PVC<br />

72,0<br />

61,2<br />

53,0<br />

48,4<br />

46,5<br />

41,3<br />

31,5<br />

24,1<br />

20,5<br />

16,6<br />

13,9<br />

10,8<br />

5,0<br />

76,1<br />

65,2<br />

57,0<br />

52,3<br />

50,0<br />

45,0<br />

36,0<br />

28,9<br />

25,2<br />

21,3<br />

19,1<br />

16,5<br />

9,1<br />

4,8<br />

-2,7<br />

69,0<br />

58,2<br />

50,0<br />

45,4<br />

43,5<br />

38,3<br />

28,5<br />

21,1<br />

17,5<br />

13,6<br />

10,9<br />

7,8<br />

2,0<br />

73,1<br />

62,2<br />

54,0<br />

49,3<br />

47,0<br />

42,0<br />

33,0<br />

25,9<br />

22,2<br />

18,3<br />

16,1<br />

13,5<br />

6,1<br />

1,8<br />

-5,7<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

20<br />

82<br />

70<br />

62<br />

58<br />

56<br />

52<br />

46<br />

42<br />

40<br />

38<br />

37<br />

36<br />

34<br />

32<br />

30<br />

65<br />

53<br />

45<br />

41<br />

39<br />

35<br />

29<br />

25<br />

23<br />

21<br />

20<br />

19<br />

17<br />

80<br />

68<br />

60<br />

56<br />

54<br />

50<br />

44<br />

40<br />

38<br />

36<br />

35<br />

34<br />

32<br />

30<br />

28<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

18,8<br />

18,4<br />

18,0<br />

17,3<br />

The right to al tera tions re served.<br />

75


DATA CA BLES<br />

76<br />

N<br />

Data cab le, category 7, STP<br />

UC 600 SS 23/1 4P FRNC <strong>and</strong><br />

UC 1200 SS 22 4P FRNC<br />

AP PLI CA TIONS<br />

— Fixed in door — Eth er net 100 Mbit/s<br />

in stal la tions — Gigabit-Ethernet<br />

— FDDI — Tele phone net works<br />

— TP- PMD — ISDN<br />

— ATM — Ge neric ca bling sys tem<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 5xD<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion<br />

UC 600 340 N<br />

UC 1000 370 N<br />

CON STRUC TION<br />

UC 600 SS 23/1 4P FRNC-B<br />

Con duc tor Str<strong>and</strong>ed tinned cop per, d = 0,56 mm<br />

In su la tion PE<br />

Unit Twisted pair with alu min ium tape<br />

Earth Tin ned cop per con duc tor<br />

Shield Cop per wire braid as a com mon shield<br />

Sheath Or ange, halogen- free ma te rial<br />

Struc ture PVC- sheath also.<br />

STAN DARDS<br />

EIA/TIA 568A; TSB 36<br />

ISO/IEC 11801 2 nd ed.; JTC1 SC25 WG3 N552<br />

EN 50173; prEN 50288-4-1<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The ca ble fulfils the fire con di tion re quire ments of<br />

IEC 332-3.<br />

Halogen free ca bles have bet ter fire re sis tant prop er ties.<br />

UC 1200 SS 22 4P FRNC-B<br />

Con duc tor Str<strong>and</strong>ed tinned cop per, d = 0,64 mm<br />

In su la tion PE<br />

Unit Twisted pair with alu min ium tape<br />

Earth Tin ned cop per con duc tor<br />

Shield Cop per wire braid as a com mon shield<br />

Sheath UC 1000 Yellow, halogen-free material<br />

The right to al tera tions re served.


CA BLE SIZES<br />

Type UC 600 SS 23/1 4P UC 1200 SS 22 4P<br />

EAN code (SSTL code) 64 100+ 02 640 56 02 640 91<br />

Nomi nal di ame ters mm 7,5 8,9<br />

Mass kg/km 75 90<br />

De liv ery length m 500 500<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Data cab le, category 7, STP<br />

UC 600 SS 23/1 4P FRNC <strong>and</strong><br />

UC 1200 SS 22 4P FRNC<br />

Loop re sis tance, max Ω/km 165 130<br />

In su la tion re sis tance, min GΩ x km 2 2<br />

Nomi nal mu tual ca paci tance nF/km 43 43<br />

Maxi mum ca paci tance<br />

un bal ance, pair to ground pF/km ≤1200 ≤1200<br />

DATA CA BLES<br />

Nomi nal im ped ance Ω ƒ =1 - 100 MHz 100 ± 15 ƒ =1 - 100 MHz 100 ± 15<br />

Trans fer imped ance, max mΩ/m 100 100<br />

Ve loc ity fac tor 0,78 0,80<br />

Maxi mum volt age V 75 75<br />

UC 600 SS 23/1 4P FRNC: TRANSMISSION CHARACTERUSTICS ACC. TO CATEGORY 7 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

450<br />

600<br />

750<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,7<br />

5,9<br />

7,4<br />

8,3<br />

10,4<br />

14,9<br />

19,0<br />

21,4<br />

24,0<br />

25,6<br />

27,5<br />

31,0<br />

34,2<br />

42,7<br />

50,1<br />

2<br />

3,7<br />

5,9<br />

7,4<br />

8,3<br />

10,4<br />

14,9<br />

19,0<br />

21,3<br />

23,8<br />

25,3<br />

27,0<br />

30,1<br />

33,0<br />

42,6<br />

49,2<br />

55,5<br />

UC 1200 SS 22 4P FRNC: TRANSMISSION CHARACTERUSTICS ACC. TO CATEGORY 7 (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

125<br />

155,5<br />

175<br />

200<br />

250<br />

300<br />

450<br />

600<br />

1200<br />

Attenuation<br />

(dB/100 m)<br />

80<br />

80<br />

80<br />

80<br />

80<br />

80<br />

75<br />

72<br />

71<br />

70<br />

69<br />

68<br />

66<br />

65<br />

63<br />

61<br />

NEXT<br />

(dB)<br />

90<br />

90<br />

90<br />

90<br />

90<br />

90<br />

90<br />

87<br />

85<br />

84<br />

83<br />

82<br />

81<br />

80<br />

77<br />

75<br />

73<br />

80<br />

80<br />

80<br />

80<br />

80<br />

75<br />

71<br />

68<br />

66<br />

65<br />

64<br />

63<br />

62<br />

60<br />

58<br />

56<br />

87<br />

87<br />

87<br />

87<br />

87<br />

87<br />

87<br />

84<br />

82<br />

81<br />

80<br />

79<br />

78<br />

77<br />

74<br />

72<br />

70<br />

PS-NEXT<br />

(dB)<br />

78,0<br />

76,3<br />

74,1<br />

72,6<br />

71,7<br />

69,6<br />

60,1<br />

53,0<br />

49,6<br />

46,0<br />

43,4<br />

40,5<br />

35,0<br />

30,8<br />

20,3<br />

10,9<br />

ACR<br />

88,0<br />

86,3<br />

84,1<br />

82,6<br />

81,7<br />

79,6<br />

74,8<br />

67,7<br />

63,9<br />

60,0<br />

57,8<br />

55,2<br />

50,6<br />

46,5<br />

34,3<br />

25,8<br />

17,5<br />

(dB/100 m)<br />

78,0<br />

76,3<br />

74,1<br />

72,6<br />

71,7<br />

64,6<br />

56,1<br />

49,0<br />

44,6<br />

41,0<br />

38,4<br />

35,5<br />

31,0<br />

25,8<br />

15,3<br />

5,9<br />

PS-ACR<br />

85,0<br />

83,3<br />

81,1<br />

79,6<br />

78,7<br />

76,6<br />

71,8<br />

64,7<br />

60,9<br />

57,0<br />

54,8<br />

52,2<br />

47,6<br />

43,5<br />

31,3<br />

22,8<br />

14,5<br />

(dB/100 m)<br />

70<br />

58<br />

50<br />

46<br />

44<br />

40<br />

34<br />

30<br />

28<br />

26<br />

25<br />

24<br />

22<br />

20<br />

17<br />

14<br />

ELFEXT<br />

80<br />

80<br />

80<br />

76<br />

74<br />

70<br />

64<br />

60<br />

58<br />

56<br />

55<br />

54<br />

52<br />

50<br />

47<br />

44<br />

42<br />

(dB/100 m)<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

19<br />

17<br />

14<br />

11<br />

77<br />

77<br />

77<br />

73<br />

71<br />

67<br />

61<br />

57<br />

55<br />

53<br />

52<br />

51<br />

49<br />

47<br />

44<br />

41<br />

39<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2<br />

3,7<br />

5,9<br />

7,4<br />

8,3<br />

10,4<br />

14,9<br />

19,0<br />

21,4<br />

24,0<br />

25,6<br />

27,5<br />

31,0<br />

34,2<br />

42,7<br />

50,1<br />

1,7<br />

3,1<br />

5,2<br />

6,5<br />

7,0<br />

9,0<br />

13,0<br />

16,5<br />

19,0<br />

21,5<br />

22,5<br />

24,1<br />

26,9<br />

28,5<br />

34,9<br />

43,5<br />

58,0<br />

80<br />

80<br />

80<br />

80<br />

80<br />

80<br />

75<br />

72<br />

71<br />

70<br />

69<br />

68<br />

66<br />

65<br />

63<br />

61<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

99<br />

97<br />

96<br />

95<br />

94<br />

93<br />

90<br />

88<br />

85<br />

77<br />

77<br />

77<br />

77<br />

77<br />

77<br />

72<br />

69<br />

68<br />

67<br />

66<br />

65<br />

63<br />

62<br />

60<br />

58<br />

97<br />

97<br />

97<br />

97<br />

97<br />

97<br />

97<br />

97<br />

96<br />

94<br />

93<br />

92<br />

91<br />

90<br />

87<br />

85<br />

82<br />

78,0<br />

76,3<br />

74,1<br />

72,6<br />

71,7<br />

69,6<br />

60,1<br />

53,0<br />

49,6<br />

46,0<br />

43,4<br />

40,5<br />

35,0<br />

30,8<br />

20,3<br />

10,9<br />

98,3<br />

96,9<br />

94,8<br />

93,5<br />

93,0<br />

91,0<br />

87,0<br />

83,5<br />

79,5<br />

75,6<br />

73,9<br />

71,4<br />

67,1<br />

64,3<br />

55,3<br />

44,8<br />

27,0<br />

75,0<br />

73,3<br />

71,1<br />

69,6<br />

68,7<br />

66,6<br />

57,1<br />

50,0<br />

46,6<br />

43,0<br />

40,4<br />

37,5<br />

32,0<br />

27,8<br />

17,3<br />

7,9<br />

95,3<br />

93,9<br />

91,8<br />

90,5<br />

90,0<br />

88,0<br />

84,0<br />

80,5<br />

76,5<br />

72,6<br />

70,9<br />

68,4<br />

64,1<br />

61,3<br />

52,3<br />

41,8<br />

24,0<br />

70<br />

58<br />

50<br />

46<br />

44<br />

40<br />

34<br />

30<br />

28<br />

26<br />

25<br />

24<br />

22<br />

20<br />

17<br />

14<br />

98<br />

97<br />

95<br />

94<br />

93<br />

91<br />

87<br />

84<br />

81<br />

79<br />

78<br />

76<br />

73<br />

72<br />

65<br />

57<br />

42<br />

67<br />

55<br />

47<br />

43<br />

41<br />

37<br />

31<br />

27<br />

25<br />

23<br />

22<br />

21<br />

19<br />

17<br />

14<br />

11<br />

95<br />

94<br />

92<br />

91<br />

90<br />

88<br />

84<br />

81<br />

78<br />

76<br />

75<br />

73<br />

70<br />

69<br />

62<br />

54<br />

39<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

21<br />

21<br />

21<br />

19<br />

19<br />

19<br />

19<br />

Return<br />

loss<br />

(dB)<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

23<br />

21<br />

21<br />

21<br />

21<br />

19<br />

19<br />

19<br />

19<br />

77


DATA CA BLES<br />

78<br />

AP PLI CA TIONS<br />

Aerial, duct or direct buried installations<br />

— Fixed outdoor — Eth er net 1000 Mbit/s, 100 Mbit/s<br />

in stal la tions — Tele phone net works<br />

— CDDI — ISDN<br />

— TP- PMD — Ge neric ca bling sys tem<br />

— ATM<br />

Maxi mum ambient tem pera ture:<br />

- in operation +75 °C<br />

Low est rec om mended installation<br />

tem pera ture: –70 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- without load ≥ 35 mm<br />

- with load ≥ 70 mm<br />

Category 5 outdoor cable, UTP/armoured UTP<br />

SuperCAT<br />

STAN DARDS<br />

EIA/TIA 568A<br />

ISO/IEC 11801 2 nd edition; JTC1 SC25 WG3 N552<br />

EN 50173<br />

IDEN TI FI CA TION<br />

Pair Col our code Pair Col our code<br />

1 white/blue 3 white/green<br />

2 white/orange 4 white/brown<br />

The right to al tera tions re served.


CON STRUC TION<br />

Con duc tor Bare cop per wire, d = 0,50 mm<br />

In su la tion PE<br />

Twisting 2 cores to the pair<br />

Cable lay up 4 pairs to the core<br />

CA BLE SIZES<br />

Category 5 outdoor cable, UTP/armoured UTP<br />

SuperCAT<br />

Filling Specially jelly<br />

compound<br />

Sheath Black PVC<br />

Fylly flooded - waterproof<br />

Tough UV <strong>and</strong> abrasion resistant jacket<br />

DATA CA BLES<br />

Armoured UTP:<br />

Optional aluminium or steel shielding system<br />

Type Supercat 5 UTP Supercat 5 armoured UTP<br />

EAN code (SSTL code) 64 100+ 02 601 00 02 601 01<br />

Nomi nal di ame ters mm 5,8 8,6<br />

Mass kg/km 50 130<br />

De liv ery length m 305 305<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km ≤188<br />

Re sis tance, min Ω x 100 m ≤9,38<br />

Resistance unbalance % ≤3<br />

Ca paci tance at 800 Hz pF/m 55,8<br />

Insulation resistance<br />

(500 V) MΩ x km ≥ 2000<br />

Max propagation delay skew ns/100 m ≤ 45<br />

Ve loc ity of propagation % 69<br />

TRANSMISSION CHARACTERUSTICS ACC. TO CATEGORY 5e (at 20 °C)<br />

Fre quency<br />

MHz<br />

1<br />

4<br />

10<br />

16<br />

20<br />

31,2<br />

62,5<br />

100<br />

Attenuation<br />

(dB/100 m)<br />

NEXT<br />

(dB)<br />

PS-NEXT<br />

(dB)<br />

ACR<br />

(dB/100 m)<br />

PS-ACR<br />

(dB/100 m)<br />

ELFEXT<br />

(dB/100 m)<br />

PS-ELFEXT<br />

(dB/100 m)<br />

max. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min. nom. min.<br />

2,0<br />

4,1<br />

6,5<br />

8,2<br />

9,3<br />

11,7<br />

17,0<br />

22,0<br />

1,9<br />

3,9<br />

6,2<br />

7,9<br />

9,0<br />

11,3<br />

16,4<br />

21,2<br />

85,0<br />

79,2<br />

59<br />

56<br />

55<br />

52<br />

47<br />

44<br />

65,0<br />

56,3<br />

63<br />

60<br />

59<br />

56<br />

51<br />

48<br />

79<br />

73<br />

62,7<br />

61,1<br />

61,1<br />

53,2<br />

52,6<br />

44,8<br />

62<br />

53,3<br />

47,3<br />

44,3<br />

42,8<br />

39,9<br />

35,4<br />

32,3<br />

83,1<br />

75,3<br />

62,2<br />

58,6<br />

58,3<br />

50,4<br />

42,4<br />

30,5<br />

63,3<br />

52,2<br />

43,8<br />

39,1<br />

36,5<br />

30,2<br />

21,4<br />

13,3<br />

77,1<br />

69,2<br />

56,5<br />

53,2<br />

52,0<br />

41,8<br />

36,2<br />

23,6<br />

60,3<br />

49,2<br />

40,8<br />

39,1<br />

33,5<br />

28,2<br />

18,4<br />

10,3<br />

84,9<br />

74,3<br />

66,5<br />

62,5<br />

61,6<br />

57,0<br />

50,6<br />

44,9<br />

63,8<br />

51,7<br />

43,8<br />

39,7<br />

37,7<br />

33,8<br />

27,8<br />

23,8<br />

78,8<br />

67,8<br />

60,0<br />

55,8<br />

53,7<br />

49,7<br />

43,6<br />

39,1<br />

60,8<br />

48,7<br />

40,8<br />

36,7<br />

34,7<br />

30,8<br />

24,8<br />

20,8<br />

Return<br />

loss<br />

(dB)<br />

20,0<br />

23<br />

25,5<br />

25,0<br />

25,0<br />

23,6<br />

21,5<br />

20,1<br />

The right to al tera tions re served.<br />

79


80<br />

Fibre optic cables in premises<br />

data networks


TYPE COD ING OF OP TI CAL FI BRE<br />

CA BLES<br />

An ex am ple of the ca ble des ig na tion<br />

Cable construction<br />

Number <strong>and</strong> grouping of the fibres<br />

Type of the fibre <strong>and</strong> the coating<br />

Characteristics of the fibres<br />

Ca ble con struc tion<br />

First let ter:<br />

F = op ti cal fi bre ca ble<br />

FYOVD2PMU 4 x 6 x SML 04S03T<br />

Sec ond let ter:<br />

Y = sin gle loose tube con struc tion (SPI RAL SPACE ® )<br />

Z = str<strong>and</strong>ed loose tube con struc tion<br />

T = str<strong>and</strong>ed tight buffer con struc tion<br />

X = slot ted core con struc tion<br />

Next let ters:<br />

B = laminated O = filling compound<br />

C = copper P = round steel wire<br />

D = corrugated R = nonmetallic<br />

H = metal (aluminium) strength member<br />

tape V = steel tape<br />

J = jute S = indoor installation<br />

K = messenger U = outdoor installation<br />

wire<br />

L = lead<br />

M = plastic W = submarine<br />

-Y = combination cable (the last letter)<br />

Ex am ple: FYOVD2PMU (op ti cal fi bre ca ble,<br />

SPI RAL SPACE ® de sign, jelly filled, cor ru gated steel tape,<br />

plas tic sheath with two steel wires, <strong>for</strong> out door in stal la tion)<br />

Num ber <strong>and</strong> group ing of the fi bres<br />

The num bers fol low ing the let ter code in di cate the number<br />

of the fi bre groups (i.e. tubes or bun dles) <strong>and</strong> the number<br />

of the fi bres in each group.<br />

Ex am ple: 4x6 (four groups of six fi bres)<br />

Type of the fi bre <strong>and</strong> its coat ing<br />

The first two let ters of the code in di cate the type of the<br />

fi bre:<br />

SM = Single- mode fi bre (10/125 µm) ITU-T G.652<br />

GI = Mul ti mode fi bre (50/125 µm) ITU-T G.651<br />

GK = Mul ti mode fi bre (62.5/125 µm)<br />

GL = Mul ti mode fi bre (85/125 µm)<br />

GN = Mul ti mode fi bre (100/140 µm)<br />

The third let ter in di cates the outer di ame ter or the type of<br />

the coat ing<br />

L = 250 µm T = 900 µm<br />

W = 500 µm R = Rib bon<br />

Ex am ple: MSL<br />

(Single- mode fi bre ITU-T G.652 with 250 µm coat ing)<br />

GENERAL<br />

Char ac ter is tics of the fi bres<br />

The at tenua tion of the fi bre is given in tenths of deci bels<br />

per kilo me tre with two num bers fol lowed by the let ter<br />

in di cat ing the cor re spond ing wave length:<br />

F =850 nm, S =1300 nm, T = 550 nm<br />

Ex am ple: 04S03T<br />

(0.4 dB/km at 1300 nm: 0.3 dB/km at 1550 nm)<br />

For mul ti mode fi bres also the b<strong>and</strong> width is given in<br />

hun dreds of MHz km with two fig ures fol low ing the<br />

at tenua tion value.<br />

Ex am ple: 1008S (1.0 dB/km, 800 Mhz km at 300 nm)<br />

COL OUR COD ING SYS TEM OF<br />

OP TI CAL FI BRE CA BLES<br />

A col our cod ing sys tem is used <strong>for</strong> iden ti fi ca tion of op ti cal<br />

fi bres, fi bre groups <strong>and</strong> tubes. A fi bre group has nor mally<br />

not more than 6 fi bres, which are col oured as fol lows:<br />

— blue (al ways the first one)<br />

— white<br />

— yel low<br />

— green<br />

— grey<br />

— red (al ways the last one)<br />

The same col our cod ing sys tem is adapted to the bind ers<br />

over the fi bre bun dles.<br />

OPTICAL FIBRE TYPES<br />

Core Cladding<br />

Primary coating<br />

The construction <strong>and</strong> the operation principle of a single-mode<br />

fibre<br />

Core Cladding<br />

Primary coating<br />

The construction <strong>and</strong> the operation principle of a multimode<br />

fibre<br />

81


82<br />

DIFFERENT CONSTRUCTIONS OF OPTICAL FIBRE CABLES<br />

Single loose-tube<br />

FY...<br />

SPIRAL SPACE ®<br />

OPTICAL FIBRE CABLES OF NK CABLES FOR DIFFERENT APPLICATIONS<br />

Duct <strong>and</strong> buried cables<br />

SPIRAL SPACE®<br />

FYOVD2PMU steel tape armoured Spiral Space®<br />

FYO2RMU non-metallic Spiral Space® cable<br />

FZOMU non-metallic str<strong>and</strong>ed loose tube cable<br />

SPIRAL SPACE ®<br />

Buried <strong>and</strong> duct cable FYOHB2PMU<br />

Buried <strong>and</strong> duct cable FZOMVDMU<br />

CONTENTS<br />

Str<strong>and</strong>ed loose-tube<br />

FZ...<br />

Indoor cables<br />

FMS non-metallic jumper cables<br />

FMMS non-metallic breakout cable<br />

FYMSU non-metallic Spiral Space® cable<br />

Indoor installation cable FLMS<br />

Indoor cable FMMS<br />

Slotted core<br />

FX...<br />

SPIRAL SPACE ®<br />

SPIRAL SPACE ®<br />

Non-metallic buried <strong>and</strong> duct cable<br />

FYO2RMU


FYMSU-TERM DISTRIBUTION PANELS AND<br />

CABINETS<br />

CONNECTORISED RISER CABLES<br />

FYMSU-PACK 100<br />

Pigtails<br />

CONTENTS<br />

PK-100A <strong>and</strong> PK-200<br />

ORP-250<br />

PK 300<br />

83


DATA CA BLES<br />

84<br />

AP PLI CA TIONS<br />

— Fixed in door — To ken Ring 4/16 Mbit/s<br />

in stal la tions — Tele phone net works<br />

— Eth er net 10 Mbit/s — RS 232/422/423<br />

Maxi mum ambient tem pera ture:<br />

- in operation +70 °C<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

Mini mum rec om mended bend ing ra dius:<br />

- dur ing in stal la tion 10xD<br />

- during operation 15xD<br />

Data <strong>and</strong> instru men ta ti on cab le<br />

DA TA JA MAK<br />

DA TA JA MAK is available as halo gen free, DATAJAMAK- HF ver sion.<br />

STAN DARDS<br />

ISO 8802.3/IEEE 802.3 10 base T<br />

IDEN TI FI CA TION<br />

a- conductor is white <strong>and</strong> b- conductor is or ange<br />

The ca ble fufils the fire con di tion re quire ments of<br />

IEC 332-1.


CON STRUC TION<br />

Con duc tor Str<strong>and</strong>ed tinned cop per<br />

In su la tion PE<br />

Unit Twisted <strong>and</strong> in di vidu ally shielded pair<br />

with plas tic-alu min ium tape, earth<br />

con duc tor <strong>and</strong> a number tape<br />

CA BLE SIZES<br />

Data <strong>and</strong> instru men ta ti on cab le<br />

DA TA JA MAK<br />

Shield Plas tic-alu min ium tape with earth<br />

con duc tor<br />

Sheath Grey LINYL- PVC<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2 2 x (2+1) x 0,24 4 x (2+1) x 0,24 8 x (2+1) x 0,24<br />

EAN code (STTL code) 64 100+ 02 642 53-7 02 642 55-1 02 642 60-5<br />

Nomi nal di ame tersr mm 7,5 9,0 12<br />

Mass kg/km 50 75 140<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Loop re sis tance, max Ω/km 165<br />

Nomi nal mutual ca paci tance pF/m 52<br />

Capacitance earth unbalance<br />

pair to ground 1 Khz, max pF/km<br />

Nominal impedance Ω 100±15<br />

Insulatio resistance, min GΩ x km 2<br />

Ve loc ity fac tor 0,7<br />

Maximum voltage V 75<br />

Frequency 9,6 kHz<br />

fre quency 9,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

fre quency 4,0 MHz<br />

fre quency 10 MHz<br />

fre quency 16 Mhz<br />

Frequency 9,6 kHz<br />

fre quency 9,2 kHz<br />

fre quency 64 kHz<br />

fre quency 100 kHz<br />

fre quency 200 kHz<br />

fre quency 1,0 MHz<br />

fre quency 4,0 MHz<br />

fre quency 10 MHz<br />

fre quency 16 Mhz<br />

DA TA JA MAK is available as halo gen free, DATAJAMAK- HF ver sion.<br />

1500<br />

Max at tenua tion dB/100 m<br />

0,3<br />

0,5<br />

0,7<br />

0,9<br />

1,5<br />

3,3<br />

6,6<br />

9,5<br />

11,5<br />

NEXT min dB<br />

90<br />

90<br />

85<br />

85<br />

80<br />

80<br />

70<br />

70<br />

70<br />

DATA CA BLES<br />

The right to al tera tions re served.<br />

85


DATA CA BLES<br />

86<br />

AP PLI CA TIONS<br />

Wiring of digital exchanges <strong>and</strong> PCM equipment.<br />

CON STRUC TION<br />

KLVMAAM<br />

Installation cables <strong>for</strong> exchanges with screened pairs<br />

KLVMAAM, KLVMAM<br />

Con duc tor Annealed, tinned cop per wire<br />

In su la tion Cellular PE<br />

Group Two insulated conductors in a pair<br />

Group screen Plastic aluminium foil <strong>and</strong> ground wire<br />

Collective Two layers of plastic aluminium foil <strong>and</strong><br />

screen ground wire<br />

Sheath Grey Linyl<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2<br />

IDEN TI FI CA TION<br />

a- conductor is white <strong>and</strong> b- conductor is blue<br />

Screened groups numbered<br />

KLVMAAM KLVMAM<br />

2 x (2+1) x 0,4 8 x (2+1) x 0,4 16 x (2+1) x 0,4 24 x (2+1) x 0,4 2 x 0,4 x 0,4<br />

EAN code (STTL code) 64 100+ 02 021 52-3 02 021 58-5 02 021 61-5 02 021 64-6 02 021 02-8<br />

Nomi nal seath thickness mm 0,6 0,6 1,2 1,2 0,6<br />

Nominal outer diameter mm 4 x 6,5 9,0 12,5 15,0 3,5<br />

Nominal cable mass kg/km 30 75 160 220 14<br />

St<strong>and</strong>ard de liv ery length m 1000/200 1000/100 500/100 500 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

KLVMAM<br />

Characteristic impedance 1 MHz Ω 120<br />

Nomi nal mu tual ca paci tance<br />

800 MHz nF/km 47<br />

Minimum in su la tion re sis tance<br />

500 V, 1 min GΩ x km 2<br />

Attenuation<br />

1 MHz dB/100 m 3,7<br />

Minimum near-end crosstalk<br />

attenuation 1 MHz dB/100 m 80<br />

Con duc tor Annealed, tinned cop per wire<br />

In su la tion Cellular PE<br />

Group Two insulated conductors in a pair<br />

Screen Plastic aluminium foil <strong>and</strong> ground wire<br />

Sheath Black Linyl<br />

The right to al tera tions re served.


AP PLI CA TIONS<br />

Indoor cable <strong>for</strong> CATV systems<br />

Low est rec om mended installation<br />

tem pera ture: –5 °C<br />

CON STRUC TION<br />

Inner conductor Annealed copper wire<br />

Insulation Foamed PE<br />

CA BLE SIZES<br />

Num ber <strong>and</strong> size of<br />

the con duc tors mm 2<br />

Indoor cable <strong>for</strong> community antenna system<br />

TELLU 13<br />

TELLU 13 WHITE drum TELLU 13 WHITE coil<br />

EAN code (STTL code) 64 100+ 02 821 86-4 02 321 86-9<br />

Nomi nal di ame ter of<br />

the inner conductor mm 1,0 1,0<br />

Nomi nal di ame ter of<br />

the insulated conductor mm 4,8 4,8<br />

Nominal outer diameter mm 7,0 7,0<br />

Mass kg/km 56 56<br />

De liv ery length m 1000 200<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Nominal loop DC-re sis tance Ω/km 34<br />

Nomi nal ca paci tance pF/m 56<br />

Characteristic im ped ance Ω 75 ±2<br />

Ve loc ity fac tor 80<br />

Structural return loss, min. dB<br />

30 - 470 MHz<br />

470 - 860 Mhz<br />

860 - 1750 MHz<br />

Screening attenuation, min. dB 80<br />

Max at tenua tion dB/100 m<br />

fre quency 68 MHz<br />

fre quency 108 MHz<br />

fre quency 174 MHz<br />

fre quency 230 MHz<br />

fre quency 300 MHz<br />

fre quency 400 MHz<br />

fre quency 470 MHz<br />

fre quency 606 MHz<br />

fre quency 790 MHz<br />

fre quency 860 MHz<br />

fre quency 1750 MHz<br />

fre quency 2050 MHz<br />

N<br />

Mini mum rec om mended single bend ing<br />

ra dius 15 mm<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion 120 N<br />

SFS 5711<br />

Outer conductor Copper tape covered with<br />

a copper braid<br />

Sheath White Linyl<br />

18<br />

16<br />

14<br />

5,1<br />

6,5<br />

8,4<br />

9,7<br />

11,3<br />

13,2<br />

14,5<br />

16,7<br />

19,5<br />

20,5<br />

31,2<br />

34,4<br />

FORMULA FOR THE<br />

ATTENUATION COEFFICIENT OF<br />

TELLU INDOOR CABLE f ≥10 MHz<br />

α = A 1 f f + A 2f, where<br />

α = attenuation coefficient, dB/100 m<br />

f = frequency, MHz<br />

A 1 <strong>and</strong> A 2 are constants<br />

DATA CA BLES<br />

87


DATA CA BLES<br />

88<br />

AP PLI CA TIONS<br />

Indoor cable <strong>for</strong> CATV systems<br />

CA BLE SIZES<br />

Military cable<br />

RG 58, (50 Ω), RG 59, (75 Ω)<br />

Low est rec om mended installation<br />

tem pera ture: -5 °C<br />

CON STRUC TION<br />

Inner conductor<br />

RG 58r Str<strong>and</strong>ed copper wire, tin plated<br />

RG 59 Copperclad steel wire<br />

Insulation PE<br />

Type RG 58 C/U RG 59 B/U<br />

Nomi nal di ame ter of<br />

the inner conductor mm 0,9 0,59<br />

Nominal outer diameter mm 5,0 6,2<br />

Mass kg/km 40 57<br />

De liv ery length m 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

Nominal loop DC-re sis tance Ω/km 50 165<br />

Mutual ca paci tance pF/m 100 67<br />

Characteristic im ped ance Ω 50 ±2 75 ±3<br />

Ve loc ity ratio % 66 66<br />

Max at tenua tion dB/100 m<br />

fre quency 5 MHz<br />

fre quency 10 MHz<br />

fre quency 200 MHz<br />

fre quency 400 MHz<br />

fre quency 1000 MHz<br />

Transfer impedance at 3 MHz<br />

specified value mΩ/m<br />

measurement value mΩ/m<br />

operating voltage kV eff<br />

3,0<br />

4,2<br />

23<br />

34,5<br />

60<br />

50<br />

36<br />

1,8<br />

N<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion RG 58: 120 N<br />

RG 59: 145 N<br />

Copper braid<br />

RG 58r Tin plated<br />

RG 59 Bare<br />

Sheath Black PVC<br />

2,5<br />

3,5<br />

16<br />

24<br />

38<br />

36<br />

2,0


Military cable<br />

RG 213, RG 214, RG 223, (50 Ω)<br />

AP PLI CA TIONS<br />

Indoor cable <strong>for</strong> CATV systems<br />

Low est rec om mended installation<br />

tem pera ture: -5 °C<br />

CON STRUC TION<br />

Inner conductor<br />

RG 213 Str<strong>and</strong>ed copper wire,<br />

bare 7x0,75<br />

RG 214 Str<strong>and</strong>ed copper wire,<br />

silver plated 7x0,75<br />

RG 223 Copper wire, silver plated<br />

Insulation PE<br />

CA BLE SIZES<br />

Maxi mum per mis si ble ten sile stress<br />

dur ing in stal la tion RG 213 470 N<br />

RG 214 730 N<br />

RG 223 220 N<br />

RG 213 bare<br />

RG 214, RG 223<br />

1st braid Silver plated<br />

2nd braid Silver plated<br />

Sheath PVC<br />

Type RG 213 RG 214 RG 223<br />

Nomi nal di ame ter of<br />

the inner conductor mm 2,25 2,25 0,9<br />

Nominal outer diameter mm 10,3 10,8 5,5<br />

Mass kg/km 157 226 60<br />

De liv ery length m 1000 1000 1000<br />

ELEC TRI CAL PROP ER TIES 20 °C<br />

DC-re sis tance Ω/km<br />

inner conductor<br />

1st braid<br />

2nd braid<br />

5,7<br />

3,9<br />

Mutual ca paci tance pF/m 100 100 100<br />

Characteristic im ped ance Ω 50 ±2 50 ±2 50 ±2<br />

Ve loc ity ratio % 0,66 0,66 0,66<br />

Max at tenua tion dB/100 m<br />

fre quency 60 MHz<br />

fre quency 80 MHz<br />

fre quency 200 MHz<br />

fre quency 400 MHz<br />

fre quency 1000 MHz<br />

Transfer impedance at 3 MHz<br />

operating voltage kV eff<br />

test voltage kV eff<br />

5<br />

6<br />

10<br />

15<br />

4,5<br />

10,0<br />

N<br />

5,7<br />

9,4<br />

8,2<br />

6,0<br />

7,5<br />

11<br />

17<br />

4,5<br />

10,0<br />

DATA CA BLES<br />

29,1<br />

13,5<br />

15,5<br />

18,2<br />

15,5<br />

21<br />

31<br />

1,9<br />

4,1<br />

89


90<br />

Diameter of cable<br />

Type of drum<br />

5C 6C 7E 8E 9F 11G 13G 15G 16L 18M 20P 22P<br />

3<br />

4<br />

4500<br />

2460<br />

7850<br />

4410 7250 9790<br />

5<br />

6<br />

1570<br />

1120<br />

2790<br />

1950<br />

4710<br />

3210<br />

6220<br />

4400<br />

9000<br />

6130<br />

7<br />

8<br />

780<br />

580<br />

1410<br />

1080<br />

2360<br />

1800<br />

3190<br />

2370<br />

4560<br />

3480 5720 7950<br />

9<br />

10<br />

480<br />

390<br />

840<br />

660<br />

1460<br />

1170<br />

1950<br />

1490<br />

2770<br />

2170<br />

4420<br />

3720<br />

6280<br />

5090 6930 9360<br />

11<br />

12<br />

320<br />

260<br />

570<br />

480<br />

930<br />

800<br />

1300<br />

1050<br />

1790<br />

1470<br />

2960<br />

2500<br />

4210<br />

3530<br />

5520<br />

4785<br />

7820<br />

6490<br />

8260<br />

7020<br />

13<br />

14<br />

200<br />

190<br />

410<br />

350<br />

680<br />

580<br />

910<br />

790<br />

1290<br />

1130<br />

2200<br />

1800<br />

3020<br />

2590<br />

3950<br />

3465<br />

5610<br />

4830<br />

5950<br />

5030 8420<br />

15<br />

16<br />

150<br />

140<br />

290<br />

240<br />

500<br />

420<br />

680<br />

590<br />

990<br />

870<br />

1620<br />

1410<br />

2260<br />

1990<br />

3040<br />

2565<br />

4150<br />

3750<br />

4480<br />

4000<br />

7310<br />

6320<br />

8900<br />

7780<br />

17<br />

18<br />

110<br />

100<br />

230<br />

190<br />

400<br />

340<br />

500<br />

480<br />

750<br />

650<br />

1250<br />

1100<br />

1750<br />

1570<br />

2310<br />

2070<br />

3190<br />

2870<br />

3300<br />

2960<br />

5740<br />

4930<br />

6770<br />

6170<br />

19<br />

20<br />

100 180<br />

150<br />

320<br />

270<br />

410<br />

340<br />

560<br />

540<br />

960<br />

930<br />

1410<br />

1270<br />

1840<br />

1685<br />

2590<br />

2330<br />

2830<br />

2510<br />

4460<br />

4040<br />

5630<br />

4860<br />

21<br />

22<br />

140<br />

140<br />

260<br />

210<br />

330<br />

320<br />

460<br />

440<br />

800<br />

710<br />

1150<br />

1050<br />

1480<br />

1420<br />

2080<br />

1860<br />

2220<br />

1960<br />

3650<br />

3290<br />

4410<br />

4010<br />

23<br />

24<br />

200 210<br />

160<br />

270<br />

260<br />

370<br />

360<br />

680<br />

590<br />

960<br />

880<br />

1290<br />

1155<br />

1800<br />

1610<br />

1890<br />

1670<br />

2960<br />

2870<br />

3630<br />

3520<br />

25<br />

26<br />

160<br />

150<br />

210<br />

210<br />

350<br />

290<br />

570<br />

540<br />

810<br />

750<br />

1110<br />

990<br />

1430<br />

1390<br />

1600<br />

1400<br />

2580<br />

2310<br />

3190<br />

2880<br />

27<br />

28<br />

150<br />

110<br />

200<br />

160<br />

290<br />

230<br />

470<br />

450<br />

690<br />

650<br />

940<br />

830<br />

1230<br />

1200<br />

1360<br />

1180<br />

2240<br />

2000<br />

2600<br />

2520<br />

29<br />

30<br />

110<br />

110<br />

160<br />

150<br />

230<br />

220<br />

430<br />

380<br />

600<br />

560<br />

790<br />

725<br />

1050<br />

1030<br />

1140<br />

1110<br />

1950<br />

1730<br />

2260<br />

2210<br />

31<br />

32<br />

110<br />

100<br />

150<br />

150<br />

220<br />

170<br />

360<br />

345<br />

530<br />

500<br />

690<br />

630<br />

890<br />

870<br />

950<br />

930<br />

1690<br />

1490<br />

1970<br />

1930<br />

33<br />

34<br />

110<br />

110<br />

170<br />

170<br />

300<br />

315<br />

470<br />

440<br />

595<br />

560<br />

860<br />

740<br />

900<br />

770<br />

1450<br />

1420<br />

1720<br />

1680<br />

35<br />

36<br />

110<br />

100<br />

160<br />

160<br />

305<br />

280<br />

410<br />

390<br />

555<br />

480<br />

720<br />

710<br />

750<br />

730<br />

1250<br />

1220<br />

1640<br />

1450<br />

37<br />

38<br />

100 120<br />

120<br />

270<br />

240<br />

370<br />

350<br />

470<br />

445<br />

610<br />

610<br />

720<br />

600<br />

1190<br />

1040<br />

1420<br />

1390<br />

39<br />

40<br />

120<br />

120<br />

230<br />

225<br />

330<br />

320<br />

420<br />

410<br />

580<br />

570<br />

580<br />

570<br />

1020<br />

1000<br />

1220<br />

1200<br />

41<br />

42<br />

110<br />

110<br />

210<br />

200<br />

300<br />

280<br />

405<br />

385<br />

560<br />

480<br />

560<br />

550<br />

980<br />

840<br />

1180<br />

1030<br />

43<br />

44<br />

195<br />

175<br />

270<br />

260<br />

370<br />

355<br />

470<br />

460<br />

450<br />

440<br />

830<br />

810<br />

1010<br />

990<br />

45<br />

46<br />

170<br />

165<br />

250<br />

240<br />

320<br />

325<br />

450<br />

380<br />

430<br />

420<br />

800<br />

680<br />

970<br />

840<br />

47<br />

48<br />

160<br />

150<br />

230<br />

220<br />

310<br />

290<br />

370<br />

360<br />

420<br />

410<br />

670<br />

660<br />

820<br />

810<br />

49<br />

50<br />

145<br />

140<br />

210<br />

200<br />

280<br />

275<br />

360<br />

350<br />

400<br />

320<br />

650<br />

640<br />

800<br />

790<br />

51<br />

52<br />

135 190<br />

180<br />

270<br />

250<br />

350<br />

280<br />

310<br />

310<br />

630<br />

520<br />

670<br />

660<br />

53<br />

54<br />

180<br />

170<br />

240<br />

230<br />

280<br />

270<br />

300<br />

300<br />

510<br />

510<br />

650<br />

640<br />

55<br />

56<br />

170<br />

160<br />

220<br />

210<br />

270<br />

270<br />

300<br />

290<br />

500<br />

490<br />

630<br />

620<br />

57<br />

58<br />

150<br />

150<br />

210<br />

200<br />

260<br />

260<br />

290<br />

280<br />

490<br />

400<br />

520<br />

510<br />

59<br />

60<br />

140<br />

140<br />

195<br />

190<br />

260<br />

200<br />

210<br />

210<br />

390<br />

390<br />

510<br />

500<br />

MA XI MUM LENGTH OF CAB LE<br />

PER DRUM, IN ME TERS<br />

CA BLE DRUMS


Type of<br />

drum<br />

5C<br />

6A<br />

7E<br />

8E<br />

9F<br />

11G<br />

13G<br />

15G<br />

16L<br />

18M<br />

20P<br />

22P<br />

K6<br />

K7<br />

K8<br />

K9<br />

K11<br />

K12<br />

K14<br />

K16<br />

K18<br />

EAN code<br />

(STTL-code)<br />

64 100 +<br />

99 994 05-2<br />

99 994 06-9<br />

99 994 07-6<br />

99 994 08-3<br />

99 994 09-0<br />

99 994 59-5<br />

99 994 63-2<br />

99 994 65-6<br />

99 994 16-8<br />

99 994 18-2<br />

99 994 21-2<br />

99 994 22-9<br />

DI MEN SI ONS AND WEIGHTS<br />

Drum dimensions, mm Drum weight<br />

A B C D E<br />

500<br />

600<br />

700<br />

800<br />

900<br />

1100<br />

1300<br />

1500<br />

1600<br />

1800<br />

2000<br />

2200<br />

600<br />

700<br />

800<br />

900<br />

1100<br />

1200<br />

1400<br />

1600<br />

1800<br />

500<br />

500<br />

610<br />

610<br />

660<br />

725<br />

760<br />

760<br />

970<br />

1025<br />

1155<br />

1155<br />

468<br />

580<br />

580<br />

630<br />

762<br />

982<br />

982<br />

1018<br />

1075<br />

D<br />

B<br />

250<br />

250<br />

325<br />

375<br />

425<br />

500<br />

600<br />

700<br />

800<br />

1100<br />

1100<br />

1200<br />

250<br />

325<br />

375<br />

425<br />

575<br />

675<br />

800<br />

950<br />

1100<br />

E C<br />

A<br />

400<br />

400<br />

500<br />

500<br />

550<br />

600<br />

600<br />

600<br />

800<br />

850<br />

960<br />

960<br />

400<br />

500<br />

500<br />

550<br />

650<br />

850<br />

850<br />

850<br />

850<br />

55<br />

55<br />

55<br />

55<br />

82<br />

82<br />

82<br />

82<br />

82<br />

82<br />

82<br />

82<br />

75<br />

75<br />

75<br />

75<br />

106<br />

106<br />

106<br />

106<br />

106<br />

CA BLE DRUMS<br />

kg<br />

10<br />

16<br />

20<br />

26<br />

40<br />

70<br />

105<br />

150<br />

185<br />

260<br />

350<br />

445<br />

12<br />

20<br />

25<br />

34<br />

55<br />

90<br />

115<br />

195<br />

230<br />

91


<strong>Draka</strong> NK <strong>Cables</strong> Ltd • Kimmeltie 1, 02110 Espoo, P.O. BOX 419, FIN-00101 Helsinki, Finl<strong>and</strong><br />

Tel. +358 10 5661 • Telefax +358 9 682 1007<br />

www.drakankc.fi

Hooray! Your file is uploaded and ready to be published.