Photometrics<br />
System Performance<br />
Mounting<br />
Height<br />
40'<br />
Energy<br />
Savings<br />
30'<br />
20'<br />
10'<br />
% Light<br />
Gain/Loss<br />
Part<br />
Number<br />
1000W MH<br />
-18%<br />
3HBOT<br />
T8<br />
72%<br />
3HBOT-<br />
832-<br />
EB/PLUS<br />
Coefficients of Utilization<br />
Effective floor cavity reflectance 20%<br />
rc 80% 50% 30%<br />
rw 70 50 30 10 50 30 10 50 30 10<br />
RCR<br />
0<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
3HBOT-854T5-UNV-EBT2-UPL<br />
(2) Electronic Ballasts<br />
(8) F54T5HO/841 54W T5 lamps 4500 lumens<br />
Spacing criterion: (II) 1 2 x mounting<br />
height, (⊥) 1 0 x mounting height<br />
Efficiency 90 3%<br />
Test Report: 3HB854T5UPL IES<br />
1000W MH<br />
T5<br />
58%<br />
14%<br />
3HBOT-<br />
854T5-<br />
EBT2<br />
% light gain/light loss<br />
utilize S/P adjusted<br />
lumens.<br />
System Performance Table<br />
106 106 106 106 98 98 98 93 93 93<br />
100 97 94 92 90 88 86 86 84 83<br />
93 88 84 80 82 79 76 79 76 74<br />
87 80 74 70 75 71 67 72 69 66<br />
81 73 67 62 69 64 60 66 62 59<br />
75 66 59 54 62 57 53 60 56 52<br />
70 60 54 49 57 52 48 55 50 47<br />
65 55 48 44 52 47 43 51 46 42<br />
61 50 43 39 48 42 38 46 41 37<br />
56 45 39 34 43 37 33 42 37 33<br />
52 41 35 30 40 34 30 39 33 30<br />
Zonal Lumen Summary<br />
Zone Lumens %Lamp %Fixture<br />
0-30 13023 36 2 40 0<br />
0-40 19856 55 2 61 1<br />
0-60 28801 80 0 88 6<br />
0-90 30819 85 6 94 8<br />
0-180 32523 90 3 100 0<br />
Dimensions<br />
3HBOT Lamp Configurations<br />
8-lamp<br />
5-3/16" [131mm]<br />
Dimensions for Top View<br />
32-5/16"<br />
[820mm]<br />
X=4"<br />
[102mm]<br />
Illuminance Estimator<br />
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />
Based on 100 ft. x 100 ft. Open Area<br />
3HBOT 8L 54W T5HO w/Uplight<br />
Spacing 15 ft 20 ft 25 ft 30 ft 35 ft 40 ft<br />
on Center FC LPD FC LPD FC LPD FC LPD FC LPD FC LPD<br />
20 ft 57 0.91 53 0.91 50 0.91 47 0.91 45 0.91 42 0.91<br />
25 ft 36 0.58 34 0.58 32 0.58 30 0.58 29 0.58 27 0.58<br />
30 ft 20 0.33 19 0.33 18 0.33 17 0.33 16 0.33 15 0.33<br />
35 ft 9 0.15 9 0.15 8 0.15 8 0.15 7 0.15 7 0.15<br />
Illuminance Levels (FC) & Watts Per Sq. Ft. (LPD)<br />
Based on 100 ft. x 100 ft. Open Area<br />
3HBOT 8L 32W T8 w/Uplight<br />
Choose the spacing and mounting height to determine the average footcandle and<br />
watts per square foot values.<br />
X X X X X X X<br />
32-11/16" [830mm]<br />
Ceiling Standoff<br />
Embossment<br />
41-1/2" [1054mm]<br />
33" [838mm]<br />
48" [1220mm]<br />
Top Connector<br />
Emboss<br />
7/8" KO (4)<br />
11/16" X 1"<br />
KO (2)<br />
Cost of<br />
1000 S/P<br />
Adj Lmns<br />
4000 hrs<br />
$0.08 kWh<br />
FOOTNOTES: 1 Lumen maintenance is based on lamp manufacturer's stated data 2 Design System Lumens is the fixture lumens at 40% of rated lamp life and is calculated as Quantity of Lamps x Lamp Lumens x<br />
Lumen Maintenance x Fixture Efficiency x Ballast Factor 3 S/P Ratio is the lamp manufacturers stated Scotopic/Photopic Ratio; accepted by some lighting designers to adjust for the relative strengths of scotopic<br />
and photopic vision, not yet adopted by IESNA 4 S/P Adjusted Lumens calculates the brightness perception scotopic/photopic ratio as Design System Lumens x (S/P)^ 0 5 based on 5000K lamps 5 LER (Luminaire<br />
Efficiency Ratio) is an accepted method of comparing fixture performance<br />
Mounting<br />
Height<br />
Mounting<br />
Height<br />
Design S/P<br />
No of Lamp Lumen Fixture Ballast System S/P Brightness Adjusted<br />
Spacing 15 ft 20 ft 25 ft 30 ft 35 ft 40 ft<br />
on Center FC LPD FC LPD FC LPD FC LPD FC LPD FC LPD<br />
20 ft 52 0.56 48 0.56 45 0.56 42 0.56 40 0.56 37 0.56<br />
25 ft 33 0.36 31 0.36 29 0.36 27 0.36 25 0.36 24 0.36<br />
30 ft 19 0.20 17 0.20 16 0.20 15 0.20 14 0.20 13 0.20<br />
35 ft 8 0.09 8 0.09 7 0.09 7 0.09 6 0.09 6 0.09<br />
3HBO System Comparison Lamps Lumens Maintenance 1 Efficiency Factor Lumens2 Ratio3 Perception Lumens4 Wattage LER5 3HBOT-832-EB/PLUS 8 3100 94% 90% 1.15 24128 1.95 1.40 33693 302 $2.77 115<br />
3HBOT-854T5-EBT2<br />
Comparison System<br />
8 5000 93% 90% 1.00 33480 1.90 1.38 46149 458 $3.53 91<br />
1000W Metal Halide High Bay 1 102800 45% 70% 1.00 32382 1.50 1.22 39660 1085 $12.51 26<br />