Instant On/Off and Occupancy Sensors<br />

<strong>Fluorescent</strong> systems can be used with occupancy sensors to provide instant on/off capabilities to maximize energy savings.<br />

When using T8 lamps and occupancy sensors, Cooper Lighting industrial fluorescent luminaires use only softer starting<br />

“program start” ballasts to minimize damage to the lamp. Under frequent on/off cycles, program start ballasts will dramatically<br />

extend lamp life over “instant start” ballasts.<br />

Metalux integral Occupancy Sensors<br />

are available in Aisle or 360°<br />

distributions.<br />

T8 or T5HO?<br />

If your facility currently has T8 or T5HO lamps installed, the decision on lamp choice may be easy and allow for inventory<br />

consolidation. Both lamp types provide excellent performance but the attributes of each lamp type vary. Selection of lamp<br />

type is an important consideration. The following operating characteristics should be considered when making the selection:<br />

<strong>Fluorescent</strong> High Bay System Comparison<br />

First Costs<br />

Lamp Replacement Costs<br />

Lumens Per Watt<br />

Application Heights<br />

Ambient Environments<br />

Frequency of Starts<br />

Ballasts Light Level<br />

Flexibility<br />

Luminaires in Comparison<br />

HRS/LAMP LIFE<br />

40000<br />

35000<br />

30000<br />

25000<br />

20000<br />

15000<br />

10000<br />

5000<br />

0<br />

T8 Lighting Systems T5HO Lighting Systems<br />

Similar within ranges to T5 systems with lower lamp costs offset<br />

by larger luminaire sizes.<br />

Lower cost lamps offset with higher quantity<br />

for similar light output<br />

77 77<br />

Suitable in wide ranges. Lower lumen output T8’s ideal<br />

for lower mounting heights below 15' and less ideal in<br />

mounting heights above 30'.<br />

Dependent on luminaire. T8 systems achieve maximum output<br />

in 78°F (25°C) ambient environments. Starting temperature<br />

ranges as low as 0°F (-18°C) dependent on manufacturer of<br />

lamp, ballast, age of lamps and luminaire design<br />

Standard T8 systems with instant start ballasts and frequent<br />

on/off cycles can dramatically reduce lamp life. Program<br />

Start T8 ballasts should be specified when used with high<br />

occurrence of on/off cycles.<br />

Lamp Life Comparison<br />

15 min. 30 min. 1 hr. 3 hr. 12 hr. Continuous<br />

START FREQUENCY<br />

Similar within ranges to T8 systems with higher lamp costs offset<br />

by smaller luminaire sizes.<br />

Higher cost lamps offset with lower required quantity<br />

for similar light output<br />

Suitable in wide ranges. Higher output T5HO lamps ideal for higher<br />

mounting heights where higher lumen values allow for a reduced<br />

number of lamps.<br />

Dependent on luminaire. T5HO systems achieve maximum output<br />

in 95°F (35°C) ambient environments. Starting temperature<br />

ranges as low as -20°F (-29°C) dependent on manufacturer of<br />

lamps, ballast, age of lamps and luminaire design<br />

Standard Program Start ballasted systems ideal for frequent starts<br />

and with use of occupancy sensors.<br />

Offered in multiple light output ranges typically from<br />

71% to 115% of rated lamp life output allowing for<br />

flexibility in application without changing lamp type. Currently offered in fixed Light output ranges.<br />

Metalux 2HB632/PLUS using (6) 80+CRI T8 lamps with<br />

High Output ballasts.<br />

Metalux I5455 using (4) T5HO 80+CRI lamps.<br />

Net Lumens: 17100 Wattage: 221 Net Lumens: 17600 Wattage: 229<br />

Program Start Ballasts<br />

Instant Start Ballasts<br />

4