14<br />

4<br />

Installing the boiler<br />

4.2 Burner door opening<br />

To open the burner door, electrically disconnect<br />

the burner first if burner is already mounted on the<br />

boiler.<br />

- Remove the 2 hex bolts (Fig. 4a, item 2) below the<br />

burner door opening.<br />

- Swing the burner door open<br />

- Now use top handle to open access door to flue passages.<br />

4.3 Flue gas collector installation<br />

If not pre-assembled, install collector by following steps below:<br />

– Loosen the mounting nuts.<br />

- Apply supplied sealing material on rear boiler<br />

section to tighten the exhaust collector on the<br />

rear section properly (Fig. 4b).<br />

– Mount the collector and tighten the nuts.<br />

- Do not use excessive force to avoid cracking the<br />

collector<br />

4.4 Flue pipe installation<br />

4.4.1 Chimney venting<br />

Refer to Table 11 to determine chimney size requirements<br />

based on boiler size, chimney height and internal flue chase.<br />

Always use a stainless steel chimney liner and cap off at the<br />

top of the chimney in the space between chimney interior<br />

and outside of chimney liner per NFPA 211 Section 12.4.1.2.<br />

Recommended chimney materials are Selkirk SureTemp or<br />

Supervent (JSC) venting materials, or Security Chimneys<br />

Secure Temp ASHT venting materials. All these materials<br />

are approved per UL-103HT.<br />

– Use heavy gauge (26ga. or better) black smoke pipe to<br />

connect to existing chimney.<br />

- Install factory supplied barometric near the boiler.<br />

Inspecting and cleaning existing flue<br />

- Remove blockages and dirt from chimney<br />

- Clean chimney<br />

- Repair or replace faulty sections<br />

- If necessary repair mortar and joints<br />

Minimum Size of Chimney<br />

Follow guidelines below in terms of minimum chimney height<br />

as a function of chimney diameter<br />

Chimney Size<br />

Min. Minimum Height clearance<br />

6" x 6" 17 ft.<br />

7" x 7" 16ft.<br />

8" x 8" 16 ft.<br />

6" round 19 ft.<br />

7" round 17 ft.<br />

Tab. 11 Minimum chimney height<br />

Fig. 4a Burner Door<br />

1.) Eye screws for burner mounting<br />

2.) Hex bolts for door closing<br />

Fig. 4b Flue gas collector installation<br />

To prevent down drafts extend chimney at least<br />

3 feet above the roof opening and at least 2 feet<br />

above any part of the roof within a radius of 10<br />

feet.<br />

Flue pipe Type Minimum clearance<br />

Double-wall L 9"<br />

Single-wall 26ga. 18"<br />

Application of<br />

sealing material<br />

Tab. 12 Minimum clearances to combustible objects for flue<br />

systems<br />

<strong>MESys</strong> <strong>4000</strong> - 6000 Series- Technical specifications are subject to change without prior notice.