8 Trouble Shooting<br />

This Trouble shooting section is designed as an aid in identifying<br />

malfunctions of the system and provide corrective<br />

action steps. It is broken down by major system components<br />

Malfunction Possible observation Potential causes<br />

No space heating No hot water flow through<br />

heat emitters<br />

Cold DHW Cold/luke warm domestic<br />

water<br />

<strong>Boiler</strong> remains very hot Burner continues cycling<br />

operation<br />

Trouble Shooting<br />

to assist in problem identification and correction. The list is<br />

not all inclusive but will cover most typical scenarios.<br />

Defective room thermostat, pump or zone valve, reset aquastat<br />

Burner on lock-out, pellet storage empty/lodged pellets, system<br />

air bound<br />

Defective tank aquastat, seized tank pump<br />

Burner on lock-out, pellet storage empty/lodged pellets, system<br />

air bound<br />

Check burner sensor wiring, incorrect burner software settings,<br />

check draft conditions, check room air conditions<br />

Seized control panel relay, check boiler aquastat.<br />

<strong>Boiler</strong> remains cold Burner does not run Summer time, burner in lock-out: check control lights, check<br />

fuses, check pellet supply, check draft<br />

Feed auger does not run No burner operation Check pellet supply, check pellet lodging, check electric<br />

motor, check shaft spindle<br />

Tab. 17 Note: During power outage periods, a small generator could be employed to power the pellet burner to provide heat.<br />

All pump flow or check valves and/or zone valves would need to be lifted manually to induce a thermal flow through<br />

the system. Its effectiveness will depend on the piping lay-out.<br />

Note: For detailed burner trouble shooting see Janfire manuals.<br />

<strong>MESys</strong> <strong>4000</strong> - 6000 Series - Technical specifications are subject to change without prior notice. 30<br />

8