18<br />
4 Installing the boiler<br />
4.7 Mounting the Janfire NH burner<br />
Remove the Janfire burner from its box and verify the following<br />
components:<br />
V� Janfire NH burner<br />
V� Wiring harness with plugs for feed auger operation.<br />
V� Power wiring harness with plug for power supply to<br />
burner.<br />
V� 3 pin connector with 2 sensors and corresponding wiring<br />
(labeled boiler and outdoor).<br />
V � Second 3 pin connector for communication is not used.<br />
V� Burner Installation and Service Manual.<br />
V� Drop shaft hose and 2 hose clamps<br />
Caution: Risk of Fire.<br />
Assure that upper auger opening is not positioned<br />
directly above drop shaft of the burner to prevent<br />
accidental falling of pellets into the shaft (in case<br />
of back burn).<br />
Mounting of NH Burner<br />
V� Install the burner mounting rings, supplied with the<br />
burner, into the threaded tappings adjacent to the burner<br />
mounting opening in the lower boiler door. Screw in<br />
burner eye loops no more than 10mm (3/8") into burner<br />
door.<br />
V � Do not pierce the insulation on inside of door.<br />
V � Door's burner opening is slightly wider than burner.<br />
Adjust burner fit to site circumstances, centering if<br />
there is no need to align to one side or the other.<br />
V� Insert burner into mounting opening, ensure solid seal all<br />
around mounting opening and latch burner into mounting<br />
rings and tighten latches.<br />
V � Check that burner/boiler connection is tight.<br />
V� Follow Installation and Maintenance Instructions Manual<br />
for Janfire NH Burner for additional burner installation<br />
details. The NH burner has a door contact switch to<br />
ensure solid connection between burner and boiler door.<br />
V � Note: Route burner wiring cables to either side of the boiler<br />
away from front cast iron parts.<br />
<strong>MESys</strong> <strong>4000</strong> - 6000 Series- Technical specifications are subject to change without prior notice.