18<br />

4 Installing the boiler<br />

4.7 Mounting the Janfire NH burner<br />

Remove the Janfire burner from its box and verify the following<br />

components:<br />

V� Janfire NH burner<br />

V� Wiring harness with plugs for feed auger operation.<br />

V� Power wiring harness with plug for power supply to<br />

burner.<br />

V� 3 pin connector with 2 sensors and corresponding wiring<br />

(labeled boiler and outdoor).<br />

V � Second 3 pin connector for communication is not used.<br />

V� Burner Installation and Service Manual.<br />

V� Drop shaft hose and 2 hose clamps<br />

Caution: Risk of Fire.<br />

Assure that upper auger opening is not positioned<br />

directly above drop shaft of the burner to prevent<br />

accidental falling of pellets into the shaft (in case<br />

of back burn).<br />

Mounting of NH Burner<br />

V� Install the burner mounting rings, supplied with the<br />

burner, into the threaded tappings adjacent to the burner<br />

mounting opening in the lower boiler door. Screw in<br />

burner eye loops no more than 10mm (3/8") into burner<br />

door.<br />

V � Do not pierce the insulation on inside of door.<br />

V � Door's burner opening is slightly wider than burner.<br />

Adjust burner fit to site circumstances, centering if<br />

there is no need to align to one side or the other.<br />

V� Insert burner into mounting opening, ensure solid seal all<br />

around mounting opening and latch burner into mounting<br />

rings and tighten latches.<br />

V � Check that burner/boiler connection is tight.<br />

V� Follow Installation and Maintenance Instructions Manual<br />

for Janfire NH Burner for additional burner installation<br />

details. The NH burner has a door contact switch to<br />

ensure solid connection between burner and boiler door.<br />

V � Note: Route burner wiring cables to either side of the boiler<br />

away from front cast iron parts.<br />