09.02.2013 Views

KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM

KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM

KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>KEMPER</strong>OL ®<br />

<strong>1K</strong>-<strong>PUR</strong><br />

<strong>Waterproofing</strong><br />

Uses<br />

� Used in conjunction with <strong>KEMPER</strong>OL ® Fleece for<br />

waterproofing details, joints and general<br />

waterproofing of structures e. g. on balconies,<br />

terraces and flat roofs<br />

� For new construction and remedial projects<br />

� Can be applied to virtually any substrate<br />

Features<br />

� water vapour permeable<br />

� bridges cracks<br />

� cold applied<br />

� root resistant according to FLL-testing<br />

CE-Marking<br />

Component to 2 ETA 03/0043<br />

Water vapour diffusion factor µ ~ 2300<br />

Resistance to wind loads >= 50 kPa<br />

External fire performance BROOF(t1) **<br />

Reaction to fire E ***<br />

Statement to dangerous<br />

substances<br />

does not contain<br />

any<br />

Working life W3<br />

Climatic zones M and S<br />

Imposed loads P1 to P4<br />

Roof slope S1 to S4<br />

Lowest surface temperature TL4<br />

Highest surface temperature TH4<br />

** Classification in accordance with EN 13501-5<br />

2006: DIN 4102-7 - resistance to spreading fire and radiant heat<br />

*** Classification in accordance with EN 13501-1<br />

2006: DIN 4102-1. Classification is done in class B2.<br />

Composition<br />

One-component waterproofing system based on<br />

polyurethane resin.<br />

Pack sizes<br />

7 kg, 15 kg and 25 kg<br />

Shelf Life<br />

Can be stored unopened for up to 6 months in a cool,<br />

dry, frost-free place.<br />

Properties<br />

Form liquid, onecomponent<br />

Standard colour light grey<br />

Special colours on request<br />

Workability period* [min] approx. 30<br />

Rainproof* after [min] approx. 60<br />

Can be walked on* after [h] approx. 24<br />

Cured* after [d] approx. 2-3<br />

Next coat can be applied after* [d] approx. 3/7<br />

(see rear page)<br />

* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Usage guide<br />

Depending on the condition of the substrate, the<br />

<strong>KEMPER</strong>OL ® Fleece and the required membrane<br />

thickness: approx. 3.4 kg/m² - 4.2 kg/m²


Application<br />

The substrate must be dry, sound and free from any<br />

material that would hinder adhesion.<br />

Before application of <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />

<strong>Waterproofing</strong>, prime using a <strong>KEMPER</strong>TEC ® Primer<br />

according to the priming recommendations.<br />

Apply only when substrate and ambient temperatures<br />

exceed 5 °C. During application the surface<br />

temperature must be 3 °C above the dew point. If the<br />

substrate temperature is below or at the dew point<br />

temperature then moisture can form at the surface<br />

which can affect coating adhesion and cure. (Please<br />

refer to DIN 4108 - 5 Tab.1 for a dew point graph).<br />

At temperatures of less than 10 °C, we recommend<br />

that you add <strong>KEMPER</strong>TEC ® <strong>1K</strong> Thinner.<br />

Approx. 2/3 of the <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />

<strong>Waterproofing</strong> resin is applied, the <strong>KEMPER</strong>OL ®<br />

Fleece is rolled in with a perlon roller, ensuring an<br />

overlap of 5 cm and removing any air bubbles. The<br />

remaining 1/3 of the <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />

<strong>Waterproofing</strong> is applied immediately and rolled out<br />

evenly until complete saturation is achieved.<br />

Joints on door and window elements etc. with a height<br />

of < 15 cm (as a water-bearing level from the upper<br />

edge) should have at least 5 cm of overlap.<br />

Connections to the surface sealant should be made<br />

with at least a 10 cm of overlap.<br />

The thickness of the membrane needs to meet<br />

minimum requirements defined in the European<br />

Technical Approval ETA. National regulations must be<br />

followed.<br />

<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> can be re-coated<br />

after a minimum of 3 days with <strong>KEMPER</strong>DUR ® Deko or<br />

<strong>KEMPER</strong>DUR ® Sand Coating and after a minimum of<br />

7 days with other suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />

products.<br />

Alkaline protection layer::<br />

<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> has only limited<br />

alkali resistance. For long-term exposure a coat of<br />

<strong>KEMPER</strong>TEC ® EP-Primer, <strong>KEMPER</strong>TEC ® EP5-Primer<br />

or <strong>KEMPER</strong>TEC ® AC-Primer with <strong>KEMPER</strong>TEC ® NQ<br />

0712 Natural Quartz to be sprinkled in provides<br />

suitable protection (see also Technical Information TI<br />

15 - Alkalinity).<br />

Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 15 - alkalinity<br />

- TI 23 - solvent-based products<br />

Important notice<br />

The valid version of the “Special regulations for roofs<br />

with seals”, the DIN standards valid for the respective<br />

trade and the state of the art apply when the product is<br />

applied.<br />

For chemical resistance, see the Chemical Resistance<br />

List A-Z.<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Disposal<br />

liquid EWC 08 04 09<br />

cured EWC 08 04 10<br />

GISCODE<br />

PU50<br />

General information<br />

The times given are reduced with higher and increased<br />

with lower surrounding and work surface temperatures.<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faultscorrect<br />

application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>TEC ® <strong>1K</strong><br />

Thinner<br />

Uses<br />

� For use with <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong><br />

System, <strong>KEMPER</strong>DUR ® Deko and <strong>KEMPER</strong>DUR ®<br />

Deko transparent at low temperatures (between +5<br />

°C and +10 °C)<br />

� As a liquid lid on re-used <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />

cans.<br />

� Designed for horizontal surface features<br />

Features<br />

� Optimizes viscosity at low ambient temperatures<br />

CE-Marking<br />

Component to 2 ETA 03/0043<br />

Composition<br />

Special combination of organic solvents.<br />

Pack sizes<br />

500 ml<br />

Shelf Life<br />

Can be stored unopened for up to 12 months in a<br />

cool, dry, frost-free place<br />

Properties<br />

Form liquid<br />

Colour clear<br />

Usage guide<br />

125 ml to max. 250 ml for a 7 kg-pack of <strong>KEMPER</strong>OL ®<br />

<strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>;<br />

250 ml to max. 500 ml for a 15 kg-pack of<br />

<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>;<br />

500 ml to max. 1000 ml for a 25 kg-pack of<br />

<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>;<br />

max. 250 ml for a 6 kg-pack of <strong>KEMPER</strong>DUR ® Deko;<br />

max. 250 ml for a 5 kg-pack of <strong>KEMPER</strong>DUR ® Deko<br />

transparent.<br />

Application<br />

At lower ambient temperatures (+5 °C to +10 °C) add<br />

<strong>KEMPER</strong>TEC ® <strong>1K</strong> Thinner to the <strong>KEMPER</strong>OL ® <strong>1K</strong>-<br />

<strong>PUR</strong> <strong>Waterproofing</strong> or to the coating systems<br />

<strong>KEMPER</strong>DUR ® Deko respectively <strong>KEMPER</strong>DUR ®<br />

Deko transparent before application and mix well.<br />

Personal protective equipment should be worn.<br />

Important notice<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Disposal<br />

liquid EWC 07 01 04<br />

General information<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and


purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, June 2008<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>OL ® 120<br />

Fleece<br />

Uses<br />

� As reinforcement for <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />

<strong>Waterproofing</strong> System<br />

� When applied in a double layer, this fleece can also<br />

be used for other <strong>KEMPER</strong>OL ® <strong>Waterproofing</strong><br />

Systems.<br />

� For new construction and remedial projects<br />

Features<br />

� system tested and adapted to the specific purpose<br />

� regulates the layer thickness<br />

� suitable to every shape of the surface<br />

CE-Marking<br />

Component to 3 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

Special fleece based on polyester.<br />

Pack sizes<br />

Rolls<br />

Length in metres: 50<br />

Width in cm: 105 / 70 / 52.5 / 26.25<br />

Length in metres: 25<br />

Width in cm: 26.25<br />

Shelf Life<br />

Keep away from dampness, store dry, flat and creasefree.<br />

Properties<br />

Form solid<br />

Colour white<br />

Weight [g/m²] approx. 120<br />

Application<br />

Approximately 2/3rd of the required <strong>KEMPER</strong>OL ®<br />

resin should be applied to the primed substrate prior to<br />

embedding the <strong>KEMPER</strong>OL ® 120 Fleece. All overlaps<br />

in the fleece should be saturated to ensure continuity<br />

of the system, and be a minimum of 50 mm.<br />

When this has changed colour by rolling or brushing<br />

from above, the remaining 1/3rd of resin is applied to<br />

the surface and lightly rolled to remove excess<br />

material.<br />

All overlaps in the fleece should be saturated to<br />

ensure continuity of the system, and be a minimum of<br />

50 mm. The interface with door and window elements<br />

etc., minimum recommended height 15 cm, should<br />

have a minimum 5 cm overlap. Connections to the<br />

surface waterproofing should be made with a minimum<br />

10 cm overlap.<br />

Disposal<br />

Fleece EWC 04 02 21<br />

General information<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical


information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, June 2008<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>OL ® 200<br />

Fleece<br />

Uses<br />

� As reinforcement for <strong>KEMPER</strong>OL ® waterproofing<br />

systems.<br />

� For new construction and remedial projects<br />

Features<br />

� system tested and adapted to the specific purpose<br />

� regulates the layer thickness<br />

� suitable to every shape of the surface<br />

CE-Marking<br />

Component to 3 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

Special fleece based on polyester.<br />

Pack sizes<br />

Rolls<br />

Length in metres: 50<br />

Width in cm: 105 / 70 / 52.5 / 35 / 26.25 / 21 / 10.5<br />

Shelf Life<br />

Keep away from dampness, store dry, flat and creasefree.<br />

Properties<br />

Form solid<br />

Colour white<br />

Weight [g/m²] approx. 200<br />

Disposal<br />

Fleece EWC 04 02 21<br />

Application<br />

Approximately 2/3rd of the required <strong>KEMPER</strong>OL ®<br />

resin should be applied to the primed substrate prior to<br />

embedding the <strong>KEMPER</strong>OL ® 200 Fleece. All overlaps<br />

in the fleece should be saturated to ensure continuity<br />

of the system, and be a minimum of 50 mm.<br />

When this has changed colour by rolling or brushing<br />

from above, the remaining 1/3rd of resin is applied to<br />

the surface and lightly rolled to remove excess<br />

material. The interface with door and window<br />

elements etc., minimum recommended height 15 cm,<br />

should have a minimum 5 cm overlap. Connections to<br />

the surface waterproofing should be made with a<br />

minimum 10 cm overlap.<br />

General information<br />

We guarantee the consistent high quality of our<br />

products. <strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be<br />

mixed with other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, June 2008<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>OL ® RS<br />

Reinforcement Strip<br />

Uses<br />

� As reinforcement when laying the fleece edge to<br />

edge (butt-jointed)<br />

� To achieve an even surface for further coating<br />

� For new construction and remedial projects<br />

Features<br />

� compatible to the system<br />

� improves tear resistance<br />

CE-Marking<br />

Component to 3 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

Fleece made of finely stitched fibres based on<br />

polyester.<br />

Pack sizes<br />

Rolls<br />

Length in metres: 50<br />

Width in cm: 15<br />

Shelf Life<br />

Keep away from dampness, store dry, flat and creasefree.<br />

Properties<br />

Form solid<br />

Colour white<br />

Weight [g/m²] approx. 46<br />

Usage guide<br />

For each metre of <strong>KEMPER</strong>OL ® Fleece applied edge<br />

to edge, 1 m of <strong>KEMPER</strong>OL ® RS Reinforcement Strip.<br />

Application<br />

<strong>KEMPER</strong>OL ® RS Reinforcement Strip is applied in<br />

situations where <strong>KEMPER</strong>OL ® Fleece is butt-jointed.<br />

Disposal<br />

Reinforcement Strip EWC 04 02 21<br />

General information<br />

We guarantee the consistent high quality of our<br />

products. <strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be<br />

mixed with other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, June 2008<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Priming Recommendation<br />

<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong><br />

Published 06/2009<br />

applicable = �<br />

This table represents a guide for the user and should be regarded only as a recommendation. Depending on the building, it may be necessary<br />

to carry out suitability tests (individual testing), because the overall structure must always be considered. All substrates must be evenly solid<br />

and free of separating substances (oil, seperating agents, free granules - see also TI 21). Other substrates not listed here must always be<br />

checked with regard to their adhesion performance.<br />

Substrate<br />

<strong>KEMPER</strong>TEC<br />

EP- / EP5-<br />

Primer<br />

<strong>KEMPER</strong>TEC<br />

D- / R-<br />

Primer<br />

Bitumen roof sheet<br />

(V 13, V 60, G 200, PYE (SBS)) � �<br />

<strong>KEMPER</strong>TEC<br />

FPO-Primer<br />

<strong>KEMPER</strong>TEC<br />

<strong>1K</strong>-Primer<br />

4 4,8 �<br />

APP-Bitumen roof sheet, granulated Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing<br />

Asphalt, weathered<br />

�<br />

4 � 4<br />

Plastic sheets (EPDM, ECB, PVC-P, PE, PP, PIB, EVA) Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing<br />

FPO- or TPO-Plastic sheets �<br />

Fibre-cement sheets<br />

� �<br />

Clinker, Bricks,<br />

visible brickwork stones (grinded) � �<br />

Concrete, screed<br />

Plastic-modified screed and mortar (PCC)<br />

Stones for construction (lightweight, gas or pumice concrete,<br />

cement and calcareous sandstone) �<br />

Glass (uncoated) - MEK cleaned<br />

Zinc, galvanised steel<br />

Copper, lead<br />

Steel, special steels (V2A, V4A), Aluminium<br />

Insulating materials (polystyrene, rock wool)<br />

Insulating materials (polyurethane)<br />

Wood panels, plywood, chipboard, OSB<br />

4 4,8 �<br />

4 4,8 �<br />

� 4,8 �<br />

�<br />

�<br />

Indiv. Testing<br />

Indiv. Testing Indiv. Testing<br />

Indiv. Testing<br />

2,3,4 � �<br />

�<br />

2 �<br />

2 2,3,4 �<br />

2 2,3,4 �<br />

2,3 2,3,4 2,3,4<br />

� �<br />

�<br />

�<br />

�<br />

4,6 4,6 4,6<br />

�<br />

�<br />

4,6 4,6 4,6<br />

�<br />

�<br />

4,6 � �4,6<br />

2 Mechanical pre-treatment and cleaning with <strong>KEMPER</strong>TEC® MEK Cleaning Agent necessary.<br />

3 Low adhesion – additional mechanical fastening is recommended.<br />

4 Areas with a minimum overlap larger than 15 cm necessary.<br />

6 Partition layer required!<br />

8 Consider Technical Data Sheet <strong>KEMPER</strong>TEC® <strong>1K</strong>-Primer<br />

When using this priming table, it is necessary to follow <strong>KEMPER</strong> <strong>SYSTEM</strong> preparation guidelines and technical advice. Please observe our warranty clause for application-related<br />

consultation.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>TEC ® D-<br />

Primer<br />

Uses<br />

� For priming and durable adhesion between the pretreated<br />

substrate and <strong>KEMPER</strong>OL ® waterproofing<br />

membranes.<br />

� For new construction and remedial projects<br />

Features<br />

� universal use (see priming recommendations)<br />

� solvent-free<br />

� excellent adhesion<br />

CE-Marking<br />

Component to 1 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

A solvent-free, 2-component primer based on<br />

polyurethane resin.<br />

Pack sizes<br />

2 * 1,0 kg sachets in a plastic bucket<br />

2 * 2,5 kg sachets in a plastic bucket<br />

Shelf Life<br />

Can be stored unopened for up to 12 months in a<br />

cool, dry, frost-free place.<br />

Usage guide<br />

Depending on the nature and condition of the<br />

substrate approx. 500 g/m².<br />

Properties<br />

Form liquid<br />

Colour Comp. A cream<br />

Comp. B dark<br />

brown<br />

Workability period* [min] approx. 25<br />

Rainproof* after [h] approx. 3<br />

Can be walked on* after [h] approx. 12<br />

Next coat can be applied after* [h] approx. 12<br />

* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Application<br />

The substrate must be dry, sound and free from any<br />

material that would hinder adhesion. Prepare the<br />

substrate according to Technical Information Tl 21 -<br />

Substrate Preparation.The priming recommendations<br />

should be followed.<br />

Prime only when substrate and ambient temperature<br />

exceed 5 °C and are declining. During application the<br />

surface temperature must be 3 °C above the dew<br />

point. If the dew point is not reached, the surface to be<br />

primed can form a moisture film and cause separation<br />

(DIN 4108 - 5 Tab.1).


Remove the bag from the aluminium packaging.<br />

Knead component A (cream/white coloured)<br />

thoroughly (until uniform colour achieved). Pull away<br />

the rubber cord separating the two components, so<br />

that both components A and B can be mixed together.<br />

Now knead the bag quickly and thoroughly (approx. 60<br />

secs.) so that a homogenous, streak-free primer is<br />

formed.<br />

Cut off one corner of the bag and pour the<br />

<strong>KEMPER</strong>TEC ® D-Primer onto the surface and work<br />

quickly.<br />

Apply the primer evenly with a nylon roller until the<br />

pores are closed. Distribute with a nylon roller avoiding<br />

accumulation of material.<br />

After approximately 12 hours (depending on weather<br />

conditions, such as wind, ambient temperature and<br />

humidity) and provided that the primed surface is tackfree<br />

and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />

products can be applied.<br />

Important note:<br />

<strong>KEMPER</strong>TEC ® D-Primer must be overcoated within 8<br />

days of application, otherwise adhesion of subsequent<br />

coats cannot be guaranteed and repriming will be<br />

necessary. To avoid this, <strong>KEMPER</strong>DUR ® NQ 0408<br />

Natural Quartz (approx. 2 kg/m²), should be strewed<br />

into the wet primer, allowing recoating to take place<br />

unhindered after this 8 day period.<br />

Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 21 - substrate preparation<br />

Important notice<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground.<br />

Cannot be used in swimming pools!<br />

Disposal<br />

Components A+B liquid EWC 08 04 09<br />

Components A+B cured EWC 08 04 10<br />

GISCODE<br />

PU40<br />

General information<br />

The times given are reduced with higher and<br />

increased with lower surrounding and work surface<br />

temperatures.<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>TEC ® EP-<br />

Primer<br />

Uses<br />

� For priming and durable adhesion between the pretreated<br />

substrate and <strong>KEMPER</strong>OL ® waterproofing<br />

membranes.<br />

� As bonding agent for trowel-applied levelling and<br />

repair mortar<br />

� For making an alkaline protection layer<br />

� For making a bonding coat with <strong>KEMPER</strong>TEC ® NQ<br />

0408 before applying the <strong>KEMPER</strong>DUR ® Sand<br />

Coating or <strong>KEMPER</strong>DUR ® Decor Stone<br />

� For new construction and remedial projects<br />

Features<br />

� universal use (see priming recommendations)<br />

� solvent-free<br />

� excellent adhesion<br />

� high penetration capability<br />

CE-Marking<br />

Component to 1 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

2-component primer based on epoxy resin.<br />

Pack sizes<br />

2 * 1,5 kg sachets in a plastic bucket<br />

10 kg in a tin container<br />

Shelf Life<br />

Can be stored unopened for up to 12 months in a cool,<br />

dry, frost-free place. At temperatures below 5 °C ,<br />

crystallisation may occur. This can be reversed by<br />

careful heating (40 °C).<br />

Properties<br />

Form liquid<br />

Colour Comp. A yellowish<br />

Comp. B brownish<br />

Workability period* [min] approx. 25<br />

Rainproof* after [h] approx. 6<br />

Can be walked on* after [h] approx. 16<br />

Next coat can be applied after*<br />

[h]<br />

approx. 16<br />

* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Usage guide<br />

Depending on the nature and condition of the<br />

substrate: as primer approx. 500 g/m²<br />

as a bonding coat approx. 300-500 g/m²<br />

as alkaline protection approx. 400-600 g/m².<br />

Application<br />

The substrate must be dry (in concrete, the residual<br />

moisture in the upper 2 cm must be < 5 %), sound and<br />

free from any material that would hinder adhesion.<br />

Prepare the substrate according to Technical<br />

Information Tl 21 - Substrate Preparation. The priming<br />

recommendations should be followed.<br />

Prime only when substrate and ambient temperature<br />

exceed 10 °C and are declining. During application the<br />

surface temperature must be 3 °C above the dew<br />

point. If the dew point is not reached, the surface to be<br />

primed can form a moisture film and cause separation<br />

(DIN 4108 - 5 Tab.1).


A. Packaging: 1,5 kg-sachet:<br />

Remove the bag from the aluminium packaging. Pull<br />

away the rubber cord separating the two components,<br />

so that both components A and B can be mixed<br />

together. Now knead the bag quickly and thoroughly<br />

(approx. 60 secs.) so that a homogenous, streak-free<br />

primer is formed.<br />

Cut off one corner of the bag and pour the<br />

<strong>KEMPER</strong>TEC ® EP-Primer onto the surface and work<br />

quickly.<br />

B. Packaging: 10 kg-tin container<br />

Mix component B into component A thoroughly with a<br />

stirring stick or a power drill on a slow speed. The<br />

mixture should be a uniform colour, free from streaks.<br />

Mixing time is approximately 2 minutes. Apply within 25<br />

minutes.<br />

To avoid mixing errors, the complete mixture should be<br />

poured into another container and stirred again<br />

thoroughly.<br />

Apply the primer evenly with a perlon roller, ensuring<br />

complete substrate coverage and avoiding<br />

accumulation of material.<br />

Use as a primer and bonding coat<br />

Apply the primer until the pores are closed and<br />

immediately sand with <strong>KEMPER</strong>DUR ® NQ 0408<br />

Natural Quartz ensuring full coverage (usage approx. 1<br />

- 2 kg/m²). After approximately 16 hours (depending on<br />

weather conditions, such as wind, ambient temperature<br />

and humidity) and provided that the primed surface is<br />

tack-free and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />

products can be applied.<br />

Use as trowel-applied levelling mortar<br />

Before application of the mortar, <strong>KEMPER</strong>TEC ® EP-<br />

Primer should be applied to the substrate.<br />

<strong>KEMPER</strong>TEC ® EP-Primer is mixed with<br />

<strong>KEMPER</strong>TEC ® <strong>KEMPER</strong>TEC ® KR Quartz Sand<br />

Mixture in a ratio of 1 : 4 and applied to the prepared<br />

and primed substrate to fill voids between 2 and 6 mm.<br />

Use as a trowel-applied repair mortar<br />

Before application of the repair mortar, <strong>KEMPER</strong>TEC ®<br />

EP-Primer should be applied to the substrate.<br />

<strong>KEMPER</strong>TEC ® EP-Primer is mixed with<br />

<strong>KEMPER</strong>TEC ® <strong>KEMPER</strong>TEC ® KR Quartz Sand<br />

Mixture in a ratio of 1 : 9 to fill cracks and voids of up to<br />

20 mm in depth. The mixing ratio can vary depending<br />

on substrate condition.<br />

Use as alkali protection layer:<br />

To form an alkali-resistant barrier (see also Technical<br />

Information TI 15 - Alkalinity), apply a coat of<br />

<strong>KEMPER</strong>TEC ® EP-Primer to the <strong>KEMPER</strong>OL ®<br />

waterproofing membrane (approx. 400-600 g/m²).<br />

Immediately after application, strew in approx. 500 -<br />

1000 g/m² <strong>KEMPER</strong>DUR ® NQ 0712 Natural Quartz,<br />

ensuring full surface coverage.<br />

Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 15 - alkalinity<br />

- TI 21 - substrate preparation<br />

Important notice<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground.<br />

Cannot be used in swimming pools!<br />

Disposal<br />

Components A+B liquid EWC 08 04 09<br />

Components A+B cured EWC 08 04 10<br />

GISCODE<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001<br />

RE1<br />

General information<br />

The times given are reduced with higher and increased<br />

with lower surrounding and work surface temperatures.<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009


<strong>KEMPER</strong>TEC ® EP5-<br />

Primer<br />

Uses<br />

� For priming and durable adhesion between the pretreated<br />

substrate and <strong>KEMPER</strong>OL ® waterproofing<br />

membranes.<br />

� As bonding agent for trowel-applied filler and repair<br />

mortar<br />

� As alkaline protection<br />

� For making a bonding coat with <strong>KEMPER</strong>TEC ® NQ<br />

0408 before applying the <strong>KEMPER</strong>DUR ® Sand<br />

Coating or <strong>KEMPER</strong>DUR ® Decor Stone<br />

� For new construction and remedial projects<br />

Features<br />

� solvent-free<br />

� excellent adhesion<br />

� curing at low temperature<br />

CE-Marking<br />

Component to 1 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

2-component primer based on epoxy resin.<br />

Pack sizes<br />

2 * 1,5 kg sachets in a plastic bucket<br />

10 kg in a tin container<br />

Shelf Life<br />

Can be stored unopened for up to 12 months in a cool,<br />

dry, frost-free place.<br />

Usage guide<br />

Depending on the nature and condition of the<br />

substrate: as a primer approx. 500 g/m²<br />

as a bonding coat approx. 300-500 g/m²<br />

as alkaline protection approx. 400-600 g/m².<br />

Properties<br />

Form liquid<br />

Colour Comp. A transparent<br />

Comp. B yellowish<br />

Workability period* [min] approx. 20<br />

Rainproof* after [h] approx. 3<br />

Can be walked on* after [h] approx. 4<br />

Next coat can be applied<br />

after* [h]<br />

approx. 4<br />

* Values obtained at a temperature of 23 °C - 50% rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Application<br />

The substrate must be dry (in concrete, the residual<br />

moisture in the upper 2 cm must be < 5 %), sound and<br />

free from any material that would hinder adhesion and<br />

must be prepared according to Technical Information TI<br />

21 - Substrate Preparation. The priming<br />

recommendations should be followed.<br />

Prime only when substrate and ambient temperature<br />

exceed 5 °C and are declining. During application the<br />

surface temperature must be 3 °C above the dew<br />

point. If the dew point is not reached, the surface to be<br />

primed can form a moisture film and cause separation<br />

(DIN 4108 - 5 Tab.1).<br />

A. Packaging: 1.5 kg-sachet<br />

Remove the bag from the aluminium packaging. Pull<br />

away the rubber cord separating the two components,<br />

so that both components A and B can be mixed<br />

together. Now knead the bag quickly and thoroughly<br />

(approx. 60 secs.) so that a homogenous, streak-free<br />

primer is formed.


Cut off one corner of the bag and pour the<br />

<strong>KEMPER</strong>TEC ® EP5-Primer onto the surface and work<br />

quickly.<br />

B. Packaging: 10 kg-tin container<br />

Mix component B into component A thoroughly with a<br />

stirring stick or a power drill on a slow speed. The<br />

mixture should be a uniform colour, free from streaks.<br />

Mixing time is approximately 2 minutes. Apply within 15<br />

minutes.<br />

To avoid mixing errors, the complete mixture should be<br />

poured into another container and stirred again<br />

thoroughly.<br />

Apply the primer evenly with a perlon roller, ensuring<br />

complete substrate coverage and avoiding<br />

accumulation of material.<br />

Use as primer and bonding coat<br />

Apply the primer until the pores are closed and<br />

immediately sand with <strong>KEMPER</strong>DUR ® NQ 0408<br />

Natural Quartz ensuring full coverage (usage approx.<br />

500 - 1000 g/m²). After approximately 4 hours and<br />

provided that the primed surface is tack-free and dry,<br />

further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong> products can be<br />

applied.<br />

Use as trowel-applied levelling mortar<br />

Before application of the mortar, <strong>KEMPER</strong>TEC ® EP5-<br />

Primer should be applied to the substrate.<br />

<strong>KEMPER</strong>TEC ® EP5-Primer is mixed with<br />

<strong>KEMPER</strong>TEC ® <strong>KEMPER</strong>TEC ® KR Quartz Sand<br />

Mixture in a ratio of 1 : 2 and applied to the prepared<br />

and primed substrate to fill voids between 2 and 6 mm.<br />

Use as a trowel-applied repair mortar<br />

Before application of the repair mortar, <strong>KEMPER</strong>TEC ®<br />

EP5-Primer should be applied to the substrate.<br />

<strong>KEMPER</strong>TEC ® EP5-Primer is mixed with<br />

<strong>KEMPER</strong>TEC ® KR Quartz Sand Mixture in a ratio of 1 :<br />

5 to fill cracks and voids of up to 20 mm in depth. The<br />

mixing ratio can vary depending on substrate condition.<br />

Use as alkali protection layer:><br />

To form an alkali-resistant barrier (see also Technical<br />

Information TI 15 - Alkalinity), apply a coat of<br />

<strong>KEMPER</strong>TEC ® EP5-Primer (approx. 400-600 g/m²) to<br />

the <strong>KEMPER</strong>OL ® waterproofing membrane.<br />

Immediately after application, strew in approx. 500 -<br />

1000 g/m² <strong>KEMPER</strong>DUR ® NQ 0712 Natural Quartz,<br />

ensuring full surface coverage.<br />

Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 15 - alkalinity<br />

- TI 21 - substrate preparation<br />

Important notice<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground.<br />

Cannot be used in swimming pools!<br />

Disposal<br />

Components A+B liquid EWC 08 04 09<br />

Components A+B cured EWC 08 04 10<br />

GISCODE<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001<br />

RE1<br />

General information<br />

The times given are reduced with higher and increased<br />

with lower surrounding and work surface temperatures.<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009


<strong>KEMPER</strong>TEC ® <strong>1K</strong>-<br />

Primer<br />

Uses<br />

� For priming and durable adhesion between the pretreated<br />

substrate and <strong>KEMPER</strong>OL ® waterproofing<br />

membranes.<br />

� For making a bonding coat with <strong>KEMPER</strong>TEC ® NQ<br />

0408 before applying the <strong>KEMPER</strong>DUR ® Sand<br />

Coating or <strong>KEMPER</strong>DUR ® Decor Stone<br />

� For new construction and remedial projects<br />

Features<br />

� quickly drying<br />

� excellent adhesion<br />

CE-Marking<br />

Component to 1 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

Based on isocyanate-prepolymers, dissolved in organic<br />

solvents.<br />

Pack sizes<br />

5 kg<br />

Shelf Life<br />

Can be stored unopened for up to 6 months in a cool,<br />

dry, frost-free place.<br />

Properties<br />

Form liquid<br />

Colour yellowish-clear<br />

Workability period* [min] approx. 30<br />

Rainproof* after [min] approx. 60<br />

Can be walked on* after [h] approx. 2-3<br />

Next coat can be applied after* [h] approx. 2-3<br />

* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Usage guide<br />

Depending on the absorbency of the substrate:<br />

150-300 g/m²<br />

Application<br />

The substrate must be dry (in concrete, the residual<br />

moisture in the upper 2 cm must be < 5 %), sound and<br />

free from any material that would hinder adhesion.<br />

Prepare the substrate according to Technical<br />

Information Tl 21 - Substrate Preparation. The priming<br />

recommendations should be followed.<br />

Warning: <strong>KEMPER</strong>TEC ® <strong>1K</strong>-Primer is not appropriate<br />

for every substrate!<br />

Apply only when substrate and ambient temperatures<br />

exceed 5 °C and are declining. During application the<br />

surface temperature must be 3 °C above the dew<br />

point. If the substrate temperature is below or at the<br />

dew point temperature then moisture can form at the<br />

surface which can affect coating adhesion and cure.<br />

(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />

graph).<br />

Prime in one operation until the pores are closed.<br />

Distribute with a nylon roller so that material<br />

accumulation is avoided. Otherwise the substrate may<br />

be dissolved.<br />

After approximately 1 hour (depending on weather<br />

conditions, such as wind, ambient temperature and<br />

humidity) and provided that the primed surface is tackfree<br />

and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />

products can be applied. This must be completed<br />

within the next 48 hours or separating effects may


occur.<br />

To avoid these separating effects, we recommend<br />

sanding the fresh <strong>KEMPER</strong>TEC ® <strong>1K</strong>-Primer with<br />

<strong>KEMPER</strong>TEC ® NQ 0408 Natural Quartz (approx.<br />

2kg/m²). Otherwise, it is necessary to re-prime after 48<br />

hours.<br />

Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 21 - substrate preparation<br />

- TI 23 - solvent-based products<br />

Caution: Bitumenous substrates can be dissolved,<br />

therefore material accumulation (puddles) must be<br />

avoided.<br />

Important notice<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground.<br />

Cannot be used in swimming pools!<br />

Disposal<br />

liquid EWC 08 04 09<br />

cured EWC 08 04 10<br />

GISCODE<br />

PU50<br />

General information<br />

The times given are reduced with higher and increased<br />

with lower surrounding and work surface temperatures.<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>TEC ® R-<br />

Primer<br />

Uses<br />

� For priming and durable adhesion between the pretreated<br />

substrate and <strong>KEMPER</strong>OL ® waterproofing<br />

membranes.<br />

� For new construction and remedial projects<br />

Features<br />

� solvent-free<br />

� excellent adhesion<br />

� fast curing<br />

CE-Marking<br />

Component to 1 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

A solvent-free, 2-component primer based on<br />

polyurethane resin.<br />

Pack sizes<br />

2 * 1,0 kg sachets in a plastic bucket<br />

Shelf Life<br />

Can be stored unopened for up to 12 months in a cool,<br />

dry, frost-free place.<br />

Properties<br />

Form liquid<br />

Colour Comp. A cream<br />

Comp. B dark brown<br />

Workability period* [min] approx. 8<br />

Rainproof* after [h] approx. 2<br />

Can be walked on* after [h] approx. 2-3<br />

Next coat can be applied<br />

after* [h]<br />

approx. 2-3<br />

* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Usage guide<br />

Depending on the nature and condition of the<br />

substrate: approx. 500 g/m².<br />

Application<br />

The substrate must be dry, sound and free from any<br />

material that would hinder adhesion. Prepare the<br />

substrate according to Technical Information Tl 21 -<br />

Substrate Preparation. The priming recommendations<br />

should be followed.<br />

Apply only when substrate and ambient temperatures<br />

exceed 5 °C and are declining. During application the<br />

surface temperature must be 3 °C above the dew<br />

point. If the substrate temperature is below or at the<br />

dew point temperature then moisture can form at the<br />

surface which can affect coating adhesion and cure.<br />

(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />

graph).<br />

Remove the bag from the aluminium packaging.<br />

Knead component A (cream/white coloured)<br />

thoroughly (until uniform colour achieved). Pull away<br />

the rubber cord separating the two components, so<br />

that both components A and B can be mixed together.<br />

Now knead the bag quickly and thoroughly (approx. 60<br />

secs.) so that a homogenous, streak-free primer is<br />

formed.<br />

Cut off one corner of the bag and pour the<br />

<strong>KEMPER</strong>TEC ® R-Primer onto the surface and work<br />

quickly.<br />

Prime at least once until saturated. Spread out evenly<br />

using a nylon roller, avoiding any build-up of material.<br />

After approximately 2-3 hours (depending on weather<br />

conditions, such as wind, ambient temperature and


humidity) and provided that the primed surface is tackfree<br />

and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />

products can be applied.<br />

Important note:<br />

<strong>KEMPER</strong>TEC ® R-Primer must be overcoated within 8<br />

days of application, otherwise adhesion of subsequent<br />

coats cannot be guaranteed and re-priming will be<br />

necessary. To avoid this, <strong>KEMPER</strong>DUR ® NQ 0408<br />

Natural Quartz (approx. 2 kg/m²) should be strewed<br />

into the wet primer, allowing recoating to take place<br />

unhindered after this 8 days period.<br />

Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 21 - substrate preparation<br />

Important notice<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground.<br />

Cannot be used in swimming pools!<br />

Disposal<br />

Components A+B liquid EWC 08 04 09<br />

Components A+B cured EWC 08 04 10<br />

GISCODE<br />

PU40<br />

General information<br />

The times given are reduced with higher and<br />

increased with lower surrounding and work surface<br />

temperatures. We guarantee the consistent high<br />

quality of our products. <strong>KEMPER</strong> <strong>SYSTEM</strong> products<br />

must not be mixed with other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>TEC ® FPO-<br />

Primer<br />

Uses<br />

� For excellent adhesion between polyolefin plastics<br />

(FPO/TPO) and following <strong>KEMPER</strong>OL ® products<br />

- <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> System<br />

- <strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong> <strong>Waterproofing</strong> System<br />

� For new construction and remedial projects<br />

Features<br />

� Quickly drying<br />

� Excellent adhesion on FPO sheets<br />

Composition<br />

Bonding agent dissolved in toluene.<br />

Pack sizes<br />

500 g, 1 kg und 3 kg units.<br />

Shelf Life<br />

Can be stored unopened for up to 6 months in a cool,<br />

dry, frost-free place.<br />

Properties<br />

Form liquid<br />

Colour transparent<br />

Workability period* [min] approx. 5<br />

Rainproof* after [min] approx. 30<br />

Can be walked on* after [min] approx. 30<br />

Next coat can be applied after*<br />

[min]<br />

approx. 30<br />

* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />

according to weather conditions such as wind, humidity and temperature.<br />

Usage guide<br />

Depending on the nature of the substrate: approx. 50<br />

g/m².<br />

Application<br />

The substrate must be dry, sound and free from any<br />

material that would hinder adhesion and must be<br />

prepared according to Technical Information TI 21 -<br />

Substrate Preparation.<br />

Clean surface with <strong>KEMPER</strong>TEC ® MEK Cleaning<br />

Agent.<br />

Warning: <strong>KEMPER</strong>TEC ® FPO-Primer is not<br />

appropriate for every substrate!<br />

This primer is especially developed for polyolefin<br />

plastics!<br />

Apply only when substrate and ambient temperatures<br />

exceed 5 °C and are declining. During application the<br />

surface temperature must be 3 °C above the dew<br />

point. If the substrate temperature is below or at the<br />

dew point temperature then moisture can form at the<br />

surface which can affect coating adhesion and cure.<br />

(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />

graph).<br />

Prime in one operation until the pores are closed.<br />

Distribute with a perlon roller so that material<br />

accumulation is avoided.<br />

Provided that the primer is dry and tack-free,<br />

additional suitable <strong>KEMPER</strong> <strong>SYSTEM</strong> waterproofing<br />

products (<strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong> and <strong>KEMPER</strong>OL ®<br />

<strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>) should be applied after 15 -<br />

30 minutes - depending on the weather conditions,<br />

wind humidity and temperature. The <strong>KEMPER</strong>OL ®<br />

membrane has to be applied within the next 24 hours<br />

or separating effects can occur.


Personal protective equipment should be worn.<br />

Clean the tools immediately after use with<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />

hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />

into the skin.<br />

Remark<br />

Please consider the following technical information:<br />

- TI 21 - substrate preparation<br />

- TI 23 - solvent-based products<br />

Important notice<br />

Adhesion tests on other plastic sheets (EPDM, PIB<br />

etc..) have already been made. Before applying the<br />

FPO primer on further sheets please consult <strong>KEMPER</strong><br />

<strong>SYSTEM</strong> Ltd.!<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground.<br />

Cannot be used in swimming pools!<br />

Disposal<br />

Liquid EWC 08 04 09<br />

Cured EWC 08 04 10<br />

General information<br />

The times given are reduced with higher and<br />

increased with lower surrounding and work surface<br />

temperatures.<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, August 2009<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


<strong>KEMPER</strong>TEC ® MEK<br />

Cleaning Agent<br />

Uses<br />

� Cleaning agent to clean <strong>KEMPER</strong>OL ® surfaces after<br />

a break for more than 6 hrs or for the re-treatment of<br />

existing waterproofing membranes after a longer<br />

period of time<br />

� To clean tools<br />

� To clean substrates<br />

� To remove fat or oil from metals<br />

Features<br />

� specific effectiveness<br />

� evaporates quickly<br />

CE-Marking<br />

Component to 1 ETA 03/0025<br />

ETA 03/0026<br />

ETA 03/0043<br />

ETA 03/0044<br />

Composition<br />

Organic solvent mixture.<br />

Pack sizes<br />

2 kg, 9 kg and 23 kg<br />

Shelf Life<br />

Store in a cool and dry environment.<br />

Properties<br />

Form liquid<br />

Colour clear<br />

Usage guide<br />

Depending on the degree of soiling approx. 200 g/m²<br />

Application<br />

Apply <strong>KEMPER</strong>TEC ® MEK Cleaning Agent by cloth to<br />

previously <strong>KEMPER</strong>OL ® pre-treated surfaces or soiled<br />

substrates, avoiding puddles of material. After<br />

cleaning, remove all residual cleaner.<br />

Before additional coating, ventilate the area well.<br />

For application in enclosed areas ensure there is<br />

sufficient ventilation.<br />

Caution: Danger of explosion!<br />

Personal protective equipment should be worn.<br />

Important notice<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent is to be used<br />

only for the cleaning of tools and surfaces.<br />

Caution: Plastic surfaces (acrylic glass, etc.) can be<br />

dissolved.<br />

The safety data sheets, identification of the units,<br />

hazard warnings and safety recommendations on the<br />

units must be observed during transportation, storage<br />

and application. The BG-Chemie technical information<br />

must be observed for application.<br />

Do not allow into the sewer system or into the ground!<br />

Disposal<br />

liquid EWC 07 02 04<br />

GISCODE<br />

GF40


General information<br />

We guarantee the consistent high quality of our<br />

products.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />

other manufacturers´ products.<br />

The technical information and application instructions contained herein<br />

reflect the current level of knowledge and experience with our products.<br />

In each case, the new edition supersedes the previous technical<br />

information and renders it invalid. It is therefore necessary that you<br />

always have to hand the current code of practice. When using our<br />

products, a detailed, object-related and qualified inspection is required in<br />

each individual case in order to determine whether the product and / or<br />

application technology in question meets the specific requirements and<br />

purposes. We are liable only for our products being free from faults -<br />

correct application of our products therefore falls entirely within your<br />

scope of liability and responsibility. Our products are sold exclusively on<br />

the basis of our conditions of sale and delivery.<br />

Published: Vellmar, June 2008<br />

______________________________________________________________________________________________________________<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Technical Information 23<br />

The use of products containing solvents<br />

If porous or absorbent substrates (concrete < grade B15, concrete with lightweight<br />

aggregates, aerated concrete blocks, calcium silicate bricks, autoclaved aerated concrete,<br />

clay bricks, timber, etc.) . adjacent to occupied interior spaces . are to be treated with a<br />

<strong>KEMPER</strong>OL ® waterproofing system or a <strong>KEMPER</strong>DUR® coating system, please note the<br />

following points:<br />

� <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ® products containing solvents may not be used directly<br />

on porous or absorbent substrates! (Possibility of solvent odours inside the<br />

� building)<br />

� Check the possibility of using solvent-free products.<br />

� Generally, make good all open joints, gaps, etc. or large areas of damage before<br />

beginning work.<br />

� If, nevertheless, products containing solvents are to be used, prime the entire<br />

substrate first with two coats of solvent-free <strong>KEMPER</strong>TEC ® EP-Primer or <strong>KEMPER</strong>TEC ®<br />

EP5-Primer to close all the pores. Work a layer of fine sand into the second coat.<br />

� Products containing solvents must be applied only in the thickness specified on the<br />

technical data sheets.<br />

� When applying solvents containing <strong>KEMPER</strong>TEC ® , <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ®<br />

products indoors or around windows, doors or the intakes to air-conditioning<br />

systems, fans, etc., please take all necessary safety precautions! (Switch off airconditioning,<br />

use fresh and exhaust-air plant, etc.)<br />

� Provide occupants and users with all necessary information about the work well in<br />

advance.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Solvents containing <strong>KEMPER</strong>TEC ® , <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ® products are:<br />

<strong>KEMPER</strong>TEC ® <strong>1K</strong>-Primer <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>KEMPER</strong>DUR ® Deko<br />

<strong>KEMPER</strong>TEC ® AC-Primer <strong>KEMPER</strong>OL ® AC <strong>KEMPER</strong>DUR Deko trans.<br />

<strong>KEMPER</strong>TEC ® FPO-Primer <strong>KEMPER</strong>OL ® BR <strong>KEMPER</strong>DUR ® Finish matt<br />

<strong>KEMPER</strong>TEC ® MEK Cleaning Agent <strong>KEMPER</strong>OL ® V 210 <strong>KEMPER</strong>DUR Finish glossy<br />

<strong>KEMPER</strong>OL ® V 210 M <strong>KEMPER</strong>DUR ® QB1 Binder<br />

<strong>KEMPER</strong>DUR ® AC Finish<br />

Note: This edition supersedes all previous editions of this Technical Information.<br />

Vellmar, June 2008<br />

The technical information and application instructions contained herein reflect the current level of knowledge<br />

and experience with our products. In each case, the new edition supersedes the previous technical information<br />

and renders it invalid. It is therefore necessary that you always have to hand the current code of practice. When<br />

using our products, a detailed, object-related and qualified inspection is required in each individual case in order<br />

to determine whether the product and / or application technology in question meets the specific requirements<br />

and purposes. We are liable only for our products being free from faults – correct application of our products<br />

therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively on the<br />

basis of our conditions of sale and delivery.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Technical Information 15<br />

Protecting against alkalinity of <strong>KEMPER</strong>OL ® and <strong>KEMPER</strong>DUR ® Products<br />

Without appropriate protection, <strong>KEMPER</strong> <strong>SYSTEM</strong> liquid polymer- or polyurethane-based<br />

products exhibit inadequate long-term resistance to media with extreme pH values and,<br />

therefore, must be protected against the damaging effects of alkaline media.<br />

On building sites there are many products exhibiting alkaline reactions, e.g. screeds,<br />

concrete, tile adhesives, etc. These materials contain large proportions of cement, whose<br />

principal constituent is calcium hydroxide, although there are also small amounts of sodium<br />

hydroxide. Dissolved in water (electrolytic dissociation), this sodium hydroxide exhibits a<br />

strongly alkaline reaction (up to pH 14).<br />

This means that when a product containing cement is placed directly on a <strong>KEMPER</strong>OL or<br />

<strong>KEMPER</strong>DUR product, e.g. a screed laid to falls or ceramic finishes laid in a mortar bed, over<br />

the long term there is the risk of damaging the waterproofing or coating system. In<br />

chemical terms this process is known as saponification. The saponification leads to<br />

embrittlement of the waterproofing or coating system, which reduces its elasticity.<br />

Adequate protection can be achieved only by applying a an alkaline protection layer on<br />

the cured waterproofing or coating membrane.<br />

On one-component products (e. g. <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong>, <strong>KEMPER</strong>DUR ® Deko) the alkaline<br />

protection layer can be applied after 3 to 7 days, on two-component products (e. g.<br />

<strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong>, <strong>KEMPER</strong>OL ® V 210, <strong>KEMPER</strong>DUR ® Deko 2K) the alkaline protection<br />

layer can be applied after one day.<br />

After this period of time, the <strong>KEMPER</strong>TEC ® EP-Primer, <strong>KEMPER</strong>TEC ® EP5-Primer or<br />

<strong>KEMPER</strong>TEC ® AC-Primer can be applied to the surface.<br />

This can be carried out in one operation with a thick coating, approx. 400-600 g/m2<br />

(<strong>KEMPER</strong>TEC ® AC Primer: max. 500 g/m²). <strong>KEMPER</strong>TEC ® NQ 0712 Natural Quartz is spread<br />

liberally (leaving no gaps) over the primer while it is still wet.<br />

However, in order to avoid imperfections in the protective layer, it is better to apply two<br />

coats of <strong>KEMPER</strong>TEC ® EP-Primer, <strong>KEMPER</strong>TEC ® EP5-Primer or <strong>KEMPER</strong>TEC ® AC-Primer each<br />

coat approx. 200-300 g/m2. With <strong>KEMPER</strong>TEC ® EP-Primer wait for one day, with<br />

<strong>KEMPER</strong>TEC ® EP5-Primer for 4 hours, with <strong>KEMPER</strong>TEC ® AC Primer for one hour before<br />

applying the second coat. Before the second coat is dry, <strong>KEMPER</strong>TEC ® NQ 0712 Natural<br />

Quartz is spread liberally (leaving no gaps) over the primer.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


With <strong>KEMPER</strong>TEC ® EP-Primer, the protective layer must be allowed to cure for at least three<br />

days at 20 °C, with <strong>KEMPER</strong>TEC ® EP5-Primer wait for two days and with <strong>KEMPER</strong>TEC ® AC for<br />

one day before any alkaline-reactive media, e.g. screeds etc., are laid on top. Lower<br />

temperatures call for a longer curing time.<br />

Note: This edition supersedes all previous editions of this Technical Information.<br />

Vellmar, June 2008<br />

The technical information and application instructions contained herein reflect the current level of knowledge<br />

and experience with our products. In each case, the new edition supersedes the previous technical information<br />

and renders it invalid. It is therefore necessary that you always have to hand the current code of practice. When<br />

using our products, a detailed, object-related and qualified inspection is required in each individual case in order<br />

to determine whether the product and / or application technology in question meets the specific requirements<br />

and purposes. We are liable only for our products being free from faults – correct application of our products<br />

therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively on the<br />

basis of our conditions of sale and delivery.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Technical Information 21<br />

Checking – Assessing – Preparing the substrate<br />

General<br />

The most important requirement for the success and long-term adhesion of <strong>KEMPER</strong><br />

<strong>SYSTEM</strong> products is the bond with the substrate and its testing, assessment and<br />

preparation. Ignoring this requirement is the most common cause of defective<br />

workmanship, defects and complaints.<br />

Balconies, terraces and patios can have many different substrates, e.g. old ceramic tiles,<br />

mastic asphalt, old paint, or concrete/screeds. According to the requirements of DIN 18365<br />

"Flooring works", any substrate that is to be waterproofed must be firm, clean and free<br />

from all loose material, dust, dirt, oil and grease.<br />

According to the German Contract Procedures for Building Works (VOB), the contractor<br />

must test the substrate to ascertain its suitability for the specified covering. The contractor<br />

should inform the client immediately in writing if he has any doubts about the suitability<br />

of the substrate for the specified works.<br />

Checking the moisture content of the substrate<br />

In all cases, the moisture content of the top 20 mm of substrate may not exceed 5%. In the case<br />

of a fresh cement screed or concrete surfaces, a coating is not possible until the moisture<br />

content (equilibrium moisture content) of the material has dropped below 5%. This is usually<br />

not until 28 days after laying the screed or placing the concrete.<br />

In the case of substrates in contact with the soil, they must be adequately isolated against<br />

groundwater and rising damp (capillary moisture), e.g. by means of a layer of gravel (filter)<br />

plus a damp-proof membrane (dpm). So-called waterproof concrete and waterproofing<br />

screeds do not represent adequate protection because they are still permeable to water<br />

vapour.<br />

A chilled mirror hygrometer can be used to measure the moisture content. Rising damp can<br />

be checked by covering an area of approx. 1 m 2 with dense polyethylene sheeting. If the<br />

covered area turns a dark colour within 24 hours, rising damp is to be expected.<br />

Checking the strength of the substrate<br />

In all cases, the substrate must possess adequate strength.<br />

The compressive strength of concrete and screeds can be determined with a rebound hammer<br />

(Schmidt hammer). A value of min. 30 N/mm 2 is essential. The pull-off strength is determined<br />

with an adhesive strength tester. The value must be min. 1.5 N/mm 2 .<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004


<strong>KEMPER</strong>OL ® waterproofing systems are elastic, have a high inherent strength and can bridge<br />

over cracks, but as they are very thin (approx. 2 mm), they cannot perform a load-distributing<br />

function.<br />

Preparing the substrate<br />

The substrate should be prepared in such a way that a permanent, strong bond is achieved<br />

between the system to be applied and the substrate. To achieve this, the substrate must be<br />

consistently firm and free from all separating substances, sharp edges, burrs, flashes, fins, etc.<br />

The choice of a suitable preparatory method depends on the condition of the existing surface,<br />

the specification and the waterproofing system to be applied.<br />

Besides the "traditional" methods of treatment<br />

• grinding (grinder)<br />

• cutting (angle grinder, floor saw)<br />

• chiselling (chisel)<br />

• hammering (chisel scaler, needle gun)<br />

• brushing (brush, rotary brushes, brush machine)<br />

• planing (planer)<br />

• sweeping (broom, magnetic broom, sweeping machine)<br />

• blowing off (hot/warm air)<br />

• vacuuming (industrial vacuum cleaner)<br />

the following cleaning and blasting equipment<br />

• water-jet cleaner up to 5 N/cm 2 (0.5 bar)<br />

• steam cleaner up to 5 N/cm 2 (0.5 bar)<br />

• high-pressure water-jet cleaner up to 4000 N/cm 2 (400 bar)<br />

• wet-blasting equipment with blasting medium recovery<br />

• mist abrasive sandblasting equipment<br />

• wet abrasive sandblasting equipment<br />

• dry-blasting equipment with blasting medium recovery<br />

• free-jet pressure equipment<br />

• flame cleaning to DVS 0302<br />

• liquid nitrogen cleaning<br />

• infrared cleaning<br />

are also described in publications (ZTV-SIB / DAfStb).<br />

Cleaning methods using solvents are also still in use, particularly in the case of greasy or<br />

atmospheric pollution and/or flexible synthetic sheeting.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004


Preparing the substrate<br />

1. Flatness of substrate<br />

The flatness of the substrate is based on DIN 18202 "Dimensional tolerances in building<br />

construction". Unevenness and irregularities cannot be compensated for by the <strong>KEMPER</strong>OL ®<br />

primer to be applied and therefore require special treatment. High spots must be removed<br />

and low spots filled with <strong>KEMPER</strong> <strong>SYSTEM</strong> trowel-applied levelling or repair Mortar.<br />

In this case the levelling mortar is used after applying the primer. The filling compound<br />

consists of a mixture of<br />

- <strong>KEMPER</strong>TEC ® EP-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 4 or<br />

- <strong>KEMPER</strong>TEC ® EP5-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 2.<br />

The repair mortar is likewise used after applying the primer. The mortar consists of a mixture<br />

of<br />

- <strong>KEMPER</strong>TEC ® EP-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 9 or<br />

- <strong>KEMPER</strong>TEC ® EP5-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 5.<br />

The repair mortar is used for unevenness in the range 6–20 mm.<br />

Repair mortar can also be used to make good smaller damaged sections or spalling, e.g. along<br />

edges of joints. Depending on the application and the local conditions, the quartz sand/binder<br />

mixing ratio may be varied in order to obtain an optimum result. For further details please<br />

refer to the technical data sheets for <strong>KEMPER</strong>TEC ® EP-Primer or <strong>KEMPER</strong>TEC ® EP5-Primer.<br />

Either mortar has to be scattered with <strong>KEMPER</strong>TEC NQ 0408.<br />

2. Soiling<br />

<strong>KEMPER</strong>TEC ® primers do not adhere well, if at all, to soiled substrates. Therefore, the surfaces<br />

must be thoroughly cleaned wet or dry depending on the type of soiling with, for example,<br />

an industrial vacuum cleaner, high-pressure water jets, <strong>KEMPER</strong>TEC ® MEK Cleaning Agent<br />

when using steam cleaners, scouring machines and flame cleaners. Any bitumen or products<br />

containing creosote adhering to the substrate must be removed completely by planning or<br />

blast-cleaning.<br />

3. Porous and loose constituents<br />

Cement laitance, cement flakes, mortar residue and all surface constituents, e.g. old paint,<br />

that are not permanently attached to the substrate must be removed by chiselling, planing,<br />

blast-cleaning or grinding prior to applying the primer and can be levelled as described under<br />

point 1 above.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004


4. Cracks in the substrate<br />

On substrates with a cement binder a network of surface cracks does not have any<br />

detrimental effect on <strong>KEMPER</strong> <strong>SYSTEM</strong> waterproofing systems; however, greater consumption<br />

of primer must be allowed for because the substrate must be fully saturated. Continuous<br />

shrinkage cracks can be filled with <strong>KEMPER</strong>TEC ® Filling Compound after applying the primer.<br />

Settlement cracks and other cracks due to structural movement can be filled with <strong>KEMPER</strong>OL ®<br />

Repair Mortar and are bridged over reliably by applying, for example, a double layer of<br />

waterproofing at this point.<br />

5. Joints<br />

Joints in the substrate should be straight, with a consistent width and stable edges. Any<br />

damage can be made good with <strong>KEMPER</strong>TEC ® Repair Mortar.<br />

6. Voids<br />

In the case of voids, e.g. under old ceramic tile finishes, the tiles must be removed and the<br />

void must be made good with a similar material. <strong>KEMPER</strong>TEC ® Repair Mortar can also be used<br />

to level such unevenness.<br />

Relevant data sheets and standards:<br />

• DIN 18299 – General technical specifications for building works; general rules for all<br />

kinds of building works<br />

• DIN 18336 – General technical specifications for building works; <strong>Waterproofing</strong> works<br />

• DIN 18352 – General technical specifications for building works; Tile laying works<br />

• DIN 18353 – General technical specifications for building works; Floor screed works<br />

• DIN 18365 – General technical specifications for building works; Flooring works<br />

• DIN 18202 – Dimensional tolerances in building construction – buildings<br />

• DIN 18195 – <strong>Waterproofing</strong> of buildings and structures<br />

• <strong>KEMPER</strong> <strong>SYSTEM</strong> technical data sheets<br />

• <strong>KEMPER</strong> <strong>SYSTEM</strong> processing guidelines<br />

Note: This edition supersedes all previous editions of Technical Information 21.<br />

Vellmar, August 2009<br />

The technical information and application instructions contained herein reflect the current level of knowledge and experience with<br />

our products. In each case, the new edition supersedes the previous technical information and renders it invalid. It is therefore<br />

necessary that you always have to hand the current code of practice. When using our products, a detailed, object-related and<br />

qualified inspection is required in each individual case in order to determine whether the product and / or application technology in<br />

question meets the specific requirements and purposes. We are liable only for our products being free from faults – correct<br />

application of our products therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively<br />

on the basis of our conditions of sale and delivery.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004


Technical Information 24<br />

Cleaning and care of <strong>KEMPER</strong>OL ® waterproofings and <strong>KEMPER</strong>DUR ® coatings<br />

Please follow the advice given below regarding the cleaning and care of surface coatings<br />

and waterproofing systems supplied by <strong>KEMPER</strong> <strong>SYSTEM</strong>.<br />

� <strong>KEMPER</strong>OL ® waterproofing systems and coatings may be cleaned with conventional<br />

floor cleaning and care products. In all cases, follow the instructions of the<br />

manufacturer exactly regarding the use of such products.<br />

� Highly concentrated cleaning agents, disinfectants and caustic sanitary cleaners are<br />

unsuitable because they can lead to etching of <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ®<br />

surfaces.<br />

� Some window cleaning agents contain solvents which can attack the surfaces or<br />

cause discoloration. Therefore, avoid excessive splashing when cleaning windows<br />

with such products and always remove all traces of such cleaning agents from the<br />

waterproofing or coating.<br />

� Do not clean <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ® surfaces with metal brushes, scrapers or<br />

other mechanical means. High-pressure cleaning equipment or cleaning machines<br />

should be used only occasionally. The maximum pressure that may be used on<br />

<strong>KEMPER</strong>OL ® waterproofing systems is 80 bar and on <strong>KEMPER</strong>DUR ® coatings 40 bar.<br />

Pressures in excess of these may damage the surfaces. Furthermore, always maintain<br />

a distance of at least 20 cm between the nozzle and the surface.<br />

� Reposition plant tubs, flowerpots, etc. at regular intervals in order to prevent<br />

marking and discolouring the surfaces underneath. Special products for removing<br />

algae may be used as required to clean any surfaces affected by algae growths.<br />

Note: This edition supersedes all previous editions of this Technical Information.<br />

Vellmar, June 2008<br />

The technical information and application instructions contained herein reflect the current level of knowledge<br />

and experience with our products. In each case, the new edition supersedes the previous technical information<br />

and renders it invalid. It is therefore necessary that you always have to hand the current code of practice. When<br />

using our products, a detailed, object-related and qualified inspection is required in each individual case in order<br />

to determine whether the product and / or application technology in question meets the specific requirements<br />

and purposes. We are liable only for our products being free from faults – correct application of our products<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively on the<br />

basis of our conditions of sale and delivery.<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Calculation<br />

Recommendations<br />

Survey table over<br />

estimated quantities and time<br />

for the application of<br />

<strong>KEMPER</strong>OL und <strong>KEMPER</strong>DUR<br />

products<br />

Published 06/2008<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001


Product Estimated use Estimated time<br />

<strong>KEMPER</strong>TEC Primers<br />

<strong>KEMPER</strong>TEC D-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />

<strong>KEMPER</strong>TEC R-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />

<strong>KEMPER</strong>TEC <strong>1K</strong>-Primer approx. 0,3 kg / m² approx. 3 min / m²<br />

<strong>KEMPER</strong>TEC AC Primer approx. 0,5 kg / m² approx. 5 min / m²<br />

<strong>KEMPER</strong>TEC EP-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />

<strong>KEMPER</strong>TEC EP5-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />

<strong>KEMPER</strong>TEC FPO-Primer approx. 0,05 kg / m² approx. 3 min / m²<br />

Bonding coat<br />

<strong>KEMPER</strong>TEC EP-Primer with<br />

<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />

<strong>KEMPER</strong>TEC EP5-Primer with<br />

<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />

Levelling Mortar<br />

<strong>KEMPER</strong>TEC EP-Primer<br />

<strong>KEMPER</strong>TEC KR Quartz Sand Mixture<br />

(Mixture ratio 1 : 4)<br />

<strong>KEMPER</strong>TEC EP5-Primer<br />

<strong>KEMPER</strong>TEC KR Quartz Sand Mixture<br />

(Mixture ratio 1 : 2)<br />

Repair Mortar<br />

<strong>KEMPER</strong>TEC EP-Primer<br />

<strong>KEMPER</strong>TEC KR Quartz Sand mixture<br />

(Mixture ratio 1 : 9)<br />

<strong>KEMPER</strong>TEC EP5-Primer<br />

<strong>KEMPER</strong>TEC KR Quartz Sand mixture<br />

(Mixture ratio 1 : 5)<br />

Alkali Protection Layer<br />

<strong>KEMPER</strong>TEC EP-Primer with<br />

<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />

<strong>KEMPER</strong>TEC EP5-Primer with<br />

<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />

<strong>KEMPER</strong>TEC AC-Primer with<br />

<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />

<strong>KEMPER</strong>OL <strong>Waterproofing</strong><br />

<strong>KEMPER</strong>OL V 210 <strong>Waterproofing</strong> mit<br />

<strong>KEMPER</strong>OL Fleece 165<br />

<strong>KEMPER</strong>OL V 210 <strong>Waterproofing</strong> with<br />

<strong>KEMPER</strong>OL Fleece 200<br />

<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> with<br />

<strong>KEMPER</strong>OL 120 Fleece<br />

<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> with<br />

<strong>KEMPER</strong>OL Fleece 200<br />

<strong>KEMPER</strong>OL 2K-<strong>PUR</strong> <strong>Waterproofing</strong> with<br />

<strong>KEMPER</strong>OL Fleece 165<br />

approx. 0,3 kg / m²<br />

approx. 1,0 kg / m²<br />

approx. 0,3 kg / m²<br />

approx. 1,0 kg / m²<br />

approx. 1,5 kg/m²/mm.<br />

approx. 1,5 kg/m²/mm.<br />

approx. 1,5 kg/m²/mm.<br />

approx. 1,5 kg/m²/mm.<br />

approx. 0,6 kg / m²<br />

approx. 1,0 kg / m²<br />

approx. 0,6 kg / m²<br />

approx. 1,0 kg / m²<br />

approx. 0,5 kg / m²<br />

approx. 1,0 kg / m²<br />

approx. 2,8 kg / m²<br />

approx. 1,05 m² / m²<br />

approx. 3,6 kg / m²<br />

approx. 1,05 m² / m²<br />

approx. 3,6 kg / m²<br />

approx. 1,05 m² / m²<br />

approx. 4,0 kg / m²<br />

approx. 1,05 m² / m²<br />

approx. 3,6 kg / m²<br />

approx. 1,05 m² / m²<br />

approx. 5 min / m²<br />

approx. 1 min / m²<br />

approx. 5 min / m²<br />

approx. 1 min / m²<br />

approx. 7 min / m².<br />

approx. 7 min / m².<br />

approx. 7 min / m².<br />

approx. 7 min / m²<br />

approx. 6 min / m²<br />

approx. 1 min / m²<br />

approx. 6 min / m²<br />

approx. 1 min / m²<br />

approx. 6 min / m²<br />

approx. 1 min / m²<br />

approx. 15 min / m²<br />

approx. 15 min / m²<br />

approx. 12 min / m²<br />

approx. 12 min / m²<br />

approx. 15 min / m²


Product Estimated use Estimated time<br />

<strong>KEMPER</strong>OL AC <strong>Waterproofing</strong> with<br />

<strong>KEMPER</strong>OL Fleece 165<br />

<strong>KEMPER</strong>OL Fleece<br />

approx. 2,5 kg / m²<br />

approx. 1,05 m² / m²<br />

for overlapping application<br />

<strong>KEMPER</strong>OL Fleece (120, 165, 200) approx. 1,05 m² / m²<br />

for edge to edge (butt-jointed) application<br />

<strong>KEMPER</strong>OL Fleece (120, 165, 200)<br />

<strong>KEMPER</strong>OL Reinforcement Strip<br />

approx. 1,0 m² / m²<br />

approx. 1 lfm / joint<br />

<strong>KEMPER</strong>OL TP Talcum Powder (<strong>KEMPER</strong>OL V 210)<br />

approx. 10 min / m²<br />

refer to<br />

waterproofing<br />

refer to<br />

waterproofing<br />

<strong>KEMPER</strong>OL TP Talcum Powder approx. 0,1 kg / m² approx. 3 min / m²<br />

<strong>KEMPER</strong>OL AC as Coating<br />

<strong>KEMPER</strong>OL AC <strong>Waterproofing</strong> with<br />

<strong>KEMPER</strong>DUR AC Filler<br />

<strong>KEMPER</strong>DUR AC Finish with *<br />

<strong>KEMPER</strong>DUR CS Microchips<br />

<strong>KEMPER</strong>DUR HB High-Build<br />

On horizontal surfaces<br />

<strong>KEMPER</strong>DUR HB High-Build and<br />

<strong>KEMPER</strong>DUR CL Chips<br />

approx. 1,5 kg / m²<br />

approx. 3,7 kg / m²<br />

approx. 0,6 kg / m²<br />

approx. 0,1 kg / m²<br />

approx. 5,0 kg / m²<br />

approx. 0,03 kg / m²<br />

approx. 12 min / m²<br />

approx. 3 min / m²<br />

approx. 2 min / m²<br />

approx. 15 min / m²<br />

approx. 2 min / m²<br />

On vertical surfaces<br />

<strong>KEMPER</strong>DUR Deko 2K * approx. 0,4 kg / m² approx. 8 min / m²<br />

<strong>KEMPER</strong>DUR Finish*<br />

<strong>KEMPER</strong>DUR Finish gloss approx. 0,25 kg / m² approx. 5 min / m²<br />

<strong>KEMPER</strong>DUR TC<br />

<strong>KEMPER</strong>DUR TC and<br />

<strong>KEMPER</strong>DUR CQ 0408 Color Quartz<br />

<strong>KEMPER</strong>DUR TC and<br />

<strong>KEMPER</strong>DUR GR 0510 Granit<br />

<strong>KEMPER</strong>DUR TC and<br />

<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />

<strong>KEMPER</strong>DUR ECO-Finish *<br />

approx. 4,0 kg / m²<br />

approx. 4,0 kg / m²<br />

approx. 4,0 kg / m²<br />

approx. 6,0 kg / m²<br />

approx. 4,0 kg / m²<br />

approx. 5,0 kg / m²<br />

approx. 8 min / m²<br />

approx. 5 min / m²<br />

approx. 8 min / m²<br />

approx. 5 min / m²<br />

approx. 8 min / m²<br />

approx. 5 min / m²<br />

<strong>KEMPER</strong>DUR ECO-Finish ca. 0,2 kg / m² ca. 5 min / m²<br />

<strong>KEMPER</strong>DUR Sand Coating / <strong>KEMPER</strong>DUR Decor Stone<br />

refer to Adhesive Bridge<br />

<strong>KEMPER</strong>DUR QB1 Sand Coating Adhesive<br />

<strong>KEMPER</strong>DUR CQ 2035 Colour Quartz<br />

(Mixture 1,7 kg Adhesive with 25 kg Colour Quartz)<br />

<strong>KEMPER</strong>DUR QB1 Sand Coating Adhesive<br />

<strong>KEMPER</strong>DUR DS 2040 Decor Stone<br />

(Mixture 1,7 kg Adhesive with 25 kg Decor Stone)<br />

<strong>KEMPER</strong>DUR Quartz Coating<br />

<strong>KEMPER</strong>DUR Deko transparent<br />

<strong>KEMPER</strong>DUR CQ 0408 Colour Quartz<br />

approx. 18 kg / m².<br />

ca. 18 kg / m².<br />

approx. 0,3 kg / m²<br />

approx. 4,0 kg / m²<br />

approx. 20 min / m².<br />

ca. 20 min / m².<br />

approx. 4 min / m²<br />

approx. 3 min / m²


Product Estimated use Estimated time<br />

<strong>KEMPER</strong>DUR Deko transparent as Sealant<br />

(incl. sweeping away the excess of Colour Quartz)<br />

<strong>KEMPER</strong>DUR Deko *<br />

<strong>KEMPER</strong>DUR Deko<br />

<strong>KEMPER</strong>DUR CL Chips<br />

approx. 0,4 kg / m² approx. 10 min / m²<br />

approx. 1,0 kg / m²<br />

approx. 0,03 kg / m²<br />

approx. 6 min / m²<br />

approx. 2 min / m²<br />

<strong>KEMPER</strong>DUR Finish silk approx. 0,15 kg / m² approx. 3 min / m²<br />

<strong>KEMPER</strong>DUR Deko 2K *<br />

<strong>KEMPER</strong>DUR Deko 2K and<br />

<strong>KEMPER</strong>DUR Chips<br />

<strong>KEMPER</strong>DUR EP-Finish *<br />

approx. 1,0 kg / m²<br />

approx. 0,03 kg / m²<br />

approx. 8 min / m²<br />

approx. 2 min / m²<br />

<strong>KEMPER</strong>DUR EP-Finish farbig approx. 0,6 kg / m² approx. 5 min / m²<br />

This table represents a guide for the user and should be regarded only as a recommendation.<br />

For the choice of primers, waterproofing systems and coating systems, please refer to the technical data sheet of each product and the respective<br />

priming recommendation, since it is not possible, to combine all primers with all waterproofing or coating systems!<br />

Depending on the kind of detail, material consumption may increase by 20%.<br />

For special details or flashings, such as flat roof drains, ventilation pipes, doomed rooflights, etc. material consumption may increase by 100%. For<br />

small areas (up to 50 m²) add 2 min. mixing time.<br />

When calculating the consumption of fleece, consider 5 cm overlap.


Chemical resistance<br />

from A to Z<br />

Survey table for chemical resistance of<br />

unsattured Polyesters (UP)<br />

<strong>KEMPER</strong>OL V 210 <strong>Waterproofing</strong><br />

<strong>KEMPER</strong>OL BR <strong>Waterproofing</strong><br />

one-component polyurethanes (<strong>1K</strong>-PU)<br />

<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong><br />

<strong>KEMPER</strong>DUR Deko<br />

two-component polyurethanes (2K-PU)<br />

<strong>KEMPER</strong>OL 2K-<strong>PUR</strong> <strong>Waterproofing</strong><br />

<strong>KEMPER</strong>DUR Deko 2K<br />

<strong>KEMPER</strong>DUR HB High Build<br />

<strong>KEMPER</strong>DUR FC Floor Coating<br />

polymethyl methacrylates (PMMA)<br />

<strong>KEMPER</strong>OL AC <strong>Waterproofing</strong><br />

<strong>KEMPER</strong>DUR AC Finish<br />

epoxy resins (EP)<br />

<strong>KEMPER</strong>TEC EP-/ EP5-Primer<br />

<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />

www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001<br />

06/2008


Substance<br />

solid<br />

Solution<br />

liquid<br />

UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />

A Accumulator Acid<br />

x o o o + +<br />

Acetic Acid < 10 % x o o o + +<br />

Acetic Acid conc. x - - - - -<br />

Acetone x - - - - -<br />

Aluminumchloride Solution 30% x + + + + +<br />

Ammonia x - - - + +<br />

Ammonium Carbonate x x + + + + +<br />

Ammonium Chloride x x + + + + +<br />

Ammonium Perchlorate x x o o o + +<br />

Ammonium Phosphate x x + + + + +<br />

Ammonium Sulphate x x + + + + +<br />

Aqua Regia x - - - - -<br />

B Barium Chloride<br />

x x + + + + +<br />

Barium Hydroxide x o o o + +<br />

Barium Hydroxide solution x - - - + +<br />

Barium Nitrate x x + + + + +<br />

Beer x + + + + +<br />

Bleach x - - - - o<br />

Borax x x + + + + +<br />

Boric Acid x + + + + +<br />

Butanal x - - - - -<br />

Butanol x o o o + +<br />

Butylacetate x - - - - +<br />

Butyric Acid x - - - + o<br />

C Calcium Chloride<br />

x x + + + + +<br />

Calcium Formiate x x + + + + +<br />

Calcium Hydroxide x + + + + +<br />

Calcium Hydroxide moist x - - - + +<br />

Calcium Hydroxide Solution x - - - + +<br />

Calcium Nitrate x x + + + + +<br />

Carbon Tetra Chloride x - - - - -<br />

Castor Oil x o o o o +<br />

Caustic potash solution 10 % (lye) x - - - + +<br />

Caustic potash solution 10-50 % (lye) x - - - o +<br />

Caustic potash solution conc. (lye) x - - - - +<br />

+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />

o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />

(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />

- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />

Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures


Substance<br />

solid<br />

Solution<br />

liquid<br />

UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />

Caustic Soda 10 % (lye) x - - - + +<br />

Caustic Soda 10-50 % (lye) x - - - o +<br />

Caustic Soda conc. (lye) x - - - - +<br />

Chloracetic Acid x x - - - - -<br />

Chlorinated Water x o o o o o<br />

Chlorinated Water (Swimming pools) x + + + + +<br />

Chloroform x - - - - +<br />

Chromic Acid 10% x - - - - -<br />

Citric Acid x x o o o + +<br />

Cobalt Chloride x x + + + + +<br />

Cobalt Nitrate x x + + + + +<br />

Copper Chloride x x + + + + +<br />

Copper Sulphate x x + + + + +<br />

Cyclohexanol x o o o + +<br />

Cyclohexanon x o o o - o<br />

D Dibutyl Phthalate<br />

x o o o o +<br />

Dioctyl Phthalate x o o o o +<br />

E Ethanol < 50 %<br />

x o o o + o<br />

Ethanol conc. x - - - + o<br />

Ether x o o - - -<br />

Ethylacetate (Aceticacidethylester) x - - - - o<br />

Ethylglycol Acetat x - - - - o<br />

F Ferrum Chloride<br />

x x + + + + +<br />

Ferrum Chloride Solution 50% x + + + + +<br />

Ferrum Sulphate x + + + + +<br />

Ferrum Sulphate x x + + + + +<br />

Fertilizer x x o o o o o<br />

Formaldehyde 30-40% (Formalin) x o o o - +<br />

Formic Acid < 30 % x o o o o o<br />

Formic Acid 31-85 % x - - - - -<br />

Fuel Oil EL x + + + + +<br />

Fuel, Petrol x o o o o +<br />

G Glucose<br />

x x + + + + +<br />

Glycerin x + + + + +<br />

Glycol x o o o + o<br />

+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />

o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />

(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />

- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />

Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures


Substance<br />

solid<br />

Solution<br />

liquid<br />

UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />

H Hydrobromic Acid<br />

x o o o + o<br />

Hydrochloric Acid 20 % x - - - o +<br />

Hydrochloric Acid conc. x - - - o o<br />

Hydrofluoric Acid x - - - - -<br />

I Isopropyl Alcohol<br />

x o o o + o<br />

L Lactic Acid 10%<br />

x + + + + +<br />

Lactic Acid conc. x o o o o +<br />

Lead Acetate x x + + + + +<br />

Lime Chloride x o o o o o<br />

Lubricating Grease x + + + + +<br />

Lubricating Oil x + o + + +<br />

M Magnesium Chloride<br />

x x + + + + +<br />

Magnesium Nitrat x x + + + + +<br />

Magnesium Sulphate x x + + + + +<br />

Maleic Acid x x + + + + +<br />

Manganese Sulphate x x + + + + +<br />

Margarine x x + + + + +<br />

Mercury x + + + + +<br />

Mercury Chloride x x + + + + +<br />

Methanol x - - - + -<br />

Methyl Acetate x - - - - -<br />

Methyl Chloride x - - - - -<br />

Methylamine x - - - - -<br />

Methylethylketone x - - - - -<br />

Methylisobutylketone x - - - - -<br />

Milk x + + + + +<br />

Mineral Oil x + + + + +<br />

Molasses (Beet) x + + + + +<br />

N Nickel Chloride<br />

x x + + + + +<br />

Nickel Sulphate x x + + + + +<br />

O Nitric Acid (Azotic Acid)<br />

x - - - - o<br />

Oil for cooking x + + + + +<br />

Oil for Engines x + + + + +<br />

Oil from Flax (Linen) x + + + + +<br />

Oxalic Acid x x x o o o o +<br />

+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />

o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />

(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />

- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />

Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures


Substance<br />

solid<br />

Solution<br />

liquid<br />

UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />

Ozone + + + + +<br />

P Paraffin<br />

x + + + + +<br />

Perchloric Acid < 10 % x o o o + o<br />

Perchloric Acid 70 % x - - - - +<br />

Petroleum x o o o o +<br />

Phenol x x - - - - -<br />

Phosphoric Acid 10 % x o o o + +<br />

Phosphoric Acid 50 % x - - - o o<br />

Phosphoric Acid conc. x - - - - -<br />

Phthalic Acid x + + + + +<br />

Potassium Bromate x x o o o + +<br />

Potassium Carbonate x x + + + + +<br />

Potassium Chlorate x x o o o + +<br />

Potassium Chloride x x + + + + +<br />

Potassium Chromat x x o o o + +<br />

Potassium Cyanide x x + + + + +<br />

Potassium Dichromat x x o o o + +<br />

Potassium Fluoride x x + + + + +<br />

Potassium Iodid x x + + + + +<br />

Potassium Nitrat x x + + + + +<br />

Potassium Permangante x x o o o + +<br />

Potassium Phosphate x x + + + + +<br />

Potassium Sulphate x x + + + + +<br />

Propanol x o o o + o<br />

Propionic Acid 10 % x o o o + o<br />

Propionic Acid conc. x - - - o -<br />

S Salicylic Acid<br />

x x o o + + +<br />

Salt x x + + + + +<br />

Salt moist x + + + + +<br />

Silver Nitrate x x + + + + +<br />

Sodium Acetat x x + + + + +<br />

Sodium Bromat x x o o o o o<br />

Sodium Bromid x x + + + + +<br />

Sodium Carbonat x x + + + + +<br />

Sodium Chlorat x x o o o o o<br />

+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />

o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />

(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />

- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />

Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures


Substance<br />

solid<br />

Solution<br />

liquid<br />

UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />

Sodium Chlorid x x + + + + +<br />

Sodium Cyanide x x + + + + +<br />

Sodium Fluoride x x + + + + +<br />

Sodium Hypochlorite x x + + + + +<br />

Sodium HypoChlorite Solution x o o o o o<br />

Sodium Nitrate x x + + + + +<br />

Sodium Perborate x x o o o o o<br />

Sodium Perchlorat x x o o o o o<br />

Sodium Peroxide x x - - - - -<br />

Sodium Phosphate x x + + + + +<br />

Sodium Sulfite x x + + + + +<br />

Sodium Sulphate x x + + + + +<br />

Sodium-Potassium Silicate x o o o o +<br />

Stearic Acid x x + + + + +<br />

Styrene x - - - - o<br />

Succinic Acid x x + + + + +<br />

Sugar x x + + + + +<br />

Sugar moist x + + + + +<br />

Sulfuric Acid 10 % x + + + + +<br />

Sulfuric Acid 20 % x + + + + +<br />

Sulfuric Acid 40 % x o o o + o<br />

Sulfuric Acid 60 % x - - - + o<br />

Sulfuric Acid conc. x - - - - -<br />

Sulfuric Acid conc. x - - - - -<br />

T Table Salt<br />

x x + + + + +<br />

Table Salt Solution x + + + + +<br />

Tannic Acid x + + + + +<br />

Tartaric Acid x x + + + + +<br />

Tetra Hydro Furane (THF) x - - - - -<br />

Tin Chloride x x + + + + +<br />

Toluene x - - - - -<br />

Tri Sodium Phosphate x x o o o o o<br />

Trichlorethan x - - - - -<br />

Trichlorethylene x - - - - -<br />

Triethanolamine x - - - - -<br />

+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />

o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />

(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />

- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />

Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures


Substance<br />

solid<br />

Solution<br />

liquid<br />

UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />

Triethylamine x - - - - -<br />

Turpentine x o o o o o<br />

U Urea<br />

x x + + + + +<br />

Urine x o o o + +<br />

W Washing Powder 5%<br />

x + + + + +<br />

Wasser (destillated) x + + + + +<br />

Water (Sea-, Mineral-, Potable) x + + + + +<br />

Wine x + + + + +<br />

X Xylol<br />

x - - - - o<br />

Z Zinc Chloride<br />

x x + + + + +<br />

Zinc Nitrate x x + + + + +<br />

Zinc Sulphate x x + + + + +<br />

+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />

o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />

(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />

- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />

Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!