KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM
KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM
KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>KEMPER</strong>OL ®<br />
<strong>1K</strong>-<strong>PUR</strong><br />
<strong>Waterproofing</strong><br />
Uses<br />
� Used in conjunction with <strong>KEMPER</strong>OL ® Fleece for<br />
waterproofing details, joints and general<br />
waterproofing of structures e. g. on balconies,<br />
terraces and flat roofs<br />
� For new construction and remedial projects<br />
� Can be applied to virtually any substrate<br />
Features<br />
� water vapour permeable<br />
� bridges cracks<br />
� cold applied<br />
� root resistant according to FLL-testing<br />
CE-Marking<br />
Component to 2 ETA 03/0043<br />
Water vapour diffusion factor µ ~ 2300<br />
Resistance to wind loads >= 50 kPa<br />
External fire performance BROOF(t1) **<br />
Reaction to fire E ***<br />
Statement to dangerous<br />
substances<br />
does not contain<br />
any<br />
Working life W3<br />
Climatic zones M and S<br />
Imposed loads P1 to P4<br />
Roof slope S1 to S4<br />
Lowest surface temperature TL4<br />
Highest surface temperature TH4<br />
** Classification in accordance with EN 13501-5<br />
2006: DIN 4102-7 - resistance to spreading fire and radiant heat<br />
*** Classification in accordance with EN 13501-1<br />
2006: DIN 4102-1. Classification is done in class B2.<br />
Composition<br />
One-component waterproofing system based on<br />
polyurethane resin.<br />
Pack sizes<br />
7 kg, 15 kg and 25 kg<br />
Shelf Life<br />
Can be stored unopened for up to 6 months in a cool,<br />
dry, frost-free place.<br />
Properties<br />
Form liquid, onecomponent<br />
Standard colour light grey<br />
Special colours on request<br />
Workability period* [min] approx. 30<br />
Rainproof* after [min] approx. 60<br />
Can be walked on* after [h] approx. 24<br />
Cured* after [d] approx. 2-3<br />
Next coat can be applied after* [d] approx. 3/7<br />
(see rear page)<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Usage guide<br />
Depending on the condition of the substrate, the<br />
<strong>KEMPER</strong>OL ® Fleece and the required membrane<br />
thickness: approx. 3.4 kg/m² - 4.2 kg/m²
Application<br />
The substrate must be dry, sound and free from any<br />
material that would hinder adhesion.<br />
Before application of <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />
<strong>Waterproofing</strong>, prime using a <strong>KEMPER</strong>TEC ® Primer<br />
according to the priming recommendations.<br />
Apply only when substrate and ambient temperatures<br />
exceed 5 °C. During application the surface<br />
temperature must be 3 °C above the dew point. If the<br />
substrate temperature is below or at the dew point<br />
temperature then moisture can form at the surface<br />
which can affect coating adhesion and cure. (Please<br />
refer to DIN 4108 - 5 Tab.1 for a dew point graph).<br />
At temperatures of less than 10 °C, we recommend<br />
that you add <strong>KEMPER</strong>TEC ® <strong>1K</strong> Thinner.<br />
Approx. 2/3 of the <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />
<strong>Waterproofing</strong> resin is applied, the <strong>KEMPER</strong>OL ®<br />
Fleece is rolled in with a perlon roller, ensuring an<br />
overlap of 5 cm and removing any air bubbles. The<br />
remaining 1/3 of the <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />
<strong>Waterproofing</strong> is applied immediately and rolled out<br />
evenly until complete saturation is achieved.<br />
Joints on door and window elements etc. with a height<br />
of < 15 cm (as a water-bearing level from the upper<br />
edge) should have at least 5 cm of overlap.<br />
Connections to the surface sealant should be made<br />
with at least a 10 cm of overlap.<br />
The thickness of the membrane needs to meet<br />
minimum requirements defined in the European<br />
Technical Approval ETA. National regulations must be<br />
followed.<br />
<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> can be re-coated<br />
after a minimum of 3 days with <strong>KEMPER</strong>DUR ® Deko or<br />
<strong>KEMPER</strong>DUR ® Sand Coating and after a minimum of<br />
7 days with other suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />
products.<br />
Alkaline protection layer::<br />
<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> has only limited<br />
alkali resistance. For long-term exposure a coat of<br />
<strong>KEMPER</strong>TEC ® EP-Primer, <strong>KEMPER</strong>TEC ® EP5-Primer<br />
or <strong>KEMPER</strong>TEC ® AC-Primer with <strong>KEMPER</strong>TEC ® NQ<br />
0712 Natural Quartz to be sprinkled in provides<br />
suitable protection (see also Technical Information TI<br />
15 - Alkalinity).<br />
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 15 - alkalinity<br />
- TI 23 - solvent-based products<br />
Important notice<br />
The valid version of the “Special regulations for roofs<br />
with seals”, the DIN standards valid for the respective<br />
trade and the state of the art apply when the product is<br />
applied.<br />
For chemical resistance, see the Chemical Resistance<br />
List A-Z.<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Disposal<br />
liquid EWC 08 04 09<br />
cured EWC 08 04 10<br />
GISCODE<br />
PU50<br />
General information<br />
The times given are reduced with higher and increased<br />
with lower surrounding and work surface temperatures.<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faultscorrect<br />
application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>TEC ® <strong>1K</strong><br />
Thinner<br />
Uses<br />
� For use with <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong><br />
System, <strong>KEMPER</strong>DUR ® Deko and <strong>KEMPER</strong>DUR ®<br />
Deko transparent at low temperatures (between +5<br />
°C and +10 °C)<br />
� As a liquid lid on re-used <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />
cans.<br />
� Designed for horizontal surface features<br />
Features<br />
� Optimizes viscosity at low ambient temperatures<br />
CE-Marking<br />
Component to 2 ETA 03/0043<br />
Composition<br />
Special combination of organic solvents.<br />
Pack sizes<br />
500 ml<br />
Shelf Life<br />
Can be stored unopened for up to 12 months in a<br />
cool, dry, frost-free place<br />
Properties<br />
Form liquid<br />
Colour clear<br />
Usage guide<br />
125 ml to max. 250 ml for a 7 kg-pack of <strong>KEMPER</strong>OL ®<br />
<strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>;<br />
250 ml to max. 500 ml for a 15 kg-pack of<br />
<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>;<br />
500 ml to max. 1000 ml for a 25 kg-pack of<br />
<strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>;<br />
max. 250 ml for a 6 kg-pack of <strong>KEMPER</strong>DUR ® Deko;<br />
max. 250 ml for a 5 kg-pack of <strong>KEMPER</strong>DUR ® Deko<br />
transparent.<br />
Application<br />
At lower ambient temperatures (+5 °C to +10 °C) add<br />
<strong>KEMPER</strong>TEC ® <strong>1K</strong> Thinner to the <strong>KEMPER</strong>OL ® <strong>1K</strong>-<br />
<strong>PUR</strong> <strong>Waterproofing</strong> or to the coating systems<br />
<strong>KEMPER</strong>DUR ® Deko respectively <strong>KEMPER</strong>DUR ®<br />
Deko transparent before application and mix well.<br />
Personal protective equipment should be worn.<br />
Important notice<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Disposal<br />
liquid EWC 07 01 04<br />
General information<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, June 2008<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>OL ® 120<br />
Fleece<br />
Uses<br />
� As reinforcement for <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong><br />
<strong>Waterproofing</strong> System<br />
� When applied in a double layer, this fleece can also<br />
be used for other <strong>KEMPER</strong>OL ® <strong>Waterproofing</strong><br />
Systems.<br />
� For new construction and remedial projects<br />
Features<br />
� system tested and adapted to the specific purpose<br />
� regulates the layer thickness<br />
� suitable to every shape of the surface<br />
CE-Marking<br />
Component to 3 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
Special fleece based on polyester.<br />
Pack sizes<br />
Rolls<br />
Length in metres: 50<br />
Width in cm: 105 / 70 / 52.5 / 26.25<br />
Length in metres: 25<br />
Width in cm: 26.25<br />
Shelf Life<br />
Keep away from dampness, store dry, flat and creasefree.<br />
Properties<br />
Form solid<br />
Colour white<br />
Weight [g/m²] approx. 120<br />
Application<br />
Approximately 2/3rd of the required <strong>KEMPER</strong>OL ®<br />
resin should be applied to the primed substrate prior to<br />
embedding the <strong>KEMPER</strong>OL ® 120 Fleece. All overlaps<br />
in the fleece should be saturated to ensure continuity<br />
of the system, and be a minimum of 50 mm.<br />
When this has changed colour by rolling or brushing<br />
from above, the remaining 1/3rd of resin is applied to<br />
the surface and lightly rolled to remove excess<br />
material.<br />
All overlaps in the fleece should be saturated to<br />
ensure continuity of the system, and be a minimum of<br />
50 mm. The interface with door and window elements<br />
etc., minimum recommended height 15 cm, should<br />
have a minimum 5 cm overlap. Connections to the<br />
surface waterproofing should be made with a minimum<br />
10 cm overlap.<br />
Disposal<br />
Fleece EWC 04 02 21<br />
General information<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, June 2008<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>OL ® 200<br />
Fleece<br />
Uses<br />
� As reinforcement for <strong>KEMPER</strong>OL ® waterproofing<br />
systems.<br />
� For new construction and remedial projects<br />
Features<br />
� system tested and adapted to the specific purpose<br />
� regulates the layer thickness<br />
� suitable to every shape of the surface<br />
CE-Marking<br />
Component to 3 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
Special fleece based on polyester.<br />
Pack sizes<br />
Rolls<br />
Length in metres: 50<br />
Width in cm: 105 / 70 / 52.5 / 35 / 26.25 / 21 / 10.5<br />
Shelf Life<br />
Keep away from dampness, store dry, flat and creasefree.<br />
Properties<br />
Form solid<br />
Colour white<br />
Weight [g/m²] approx. 200<br />
Disposal<br />
Fleece EWC 04 02 21<br />
Application<br />
Approximately 2/3rd of the required <strong>KEMPER</strong>OL ®<br />
resin should be applied to the primed substrate prior to<br />
embedding the <strong>KEMPER</strong>OL ® 200 Fleece. All overlaps<br />
in the fleece should be saturated to ensure continuity<br />
of the system, and be a minimum of 50 mm.<br />
When this has changed colour by rolling or brushing<br />
from above, the remaining 1/3rd of resin is applied to<br />
the surface and lightly rolled to remove excess<br />
material. The interface with door and window<br />
elements etc., minimum recommended height 15 cm,<br />
should have a minimum 5 cm overlap. Connections to<br />
the surface waterproofing should be made with a<br />
minimum 10 cm overlap.<br />
General information<br />
We guarantee the consistent high quality of our<br />
products. <strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be<br />
mixed with other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, June 2008<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>OL ® RS<br />
Reinforcement Strip<br />
Uses<br />
� As reinforcement when laying the fleece edge to<br />
edge (butt-jointed)<br />
� To achieve an even surface for further coating<br />
� For new construction and remedial projects<br />
Features<br />
� compatible to the system<br />
� improves tear resistance<br />
CE-Marking<br />
Component to 3 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
Fleece made of finely stitched fibres based on<br />
polyester.<br />
Pack sizes<br />
Rolls<br />
Length in metres: 50<br />
Width in cm: 15<br />
Shelf Life<br />
Keep away from dampness, store dry, flat and creasefree.<br />
Properties<br />
Form solid<br />
Colour white<br />
Weight [g/m²] approx. 46<br />
Usage guide<br />
For each metre of <strong>KEMPER</strong>OL ® Fleece applied edge<br />
to edge, 1 m of <strong>KEMPER</strong>OL ® RS Reinforcement Strip.<br />
Application<br />
<strong>KEMPER</strong>OL ® RS Reinforcement Strip is applied in<br />
situations where <strong>KEMPER</strong>OL ® Fleece is butt-jointed.<br />
Disposal<br />
Reinforcement Strip EWC 04 02 21<br />
General information<br />
We guarantee the consistent high quality of our<br />
products. <strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be<br />
mixed with other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, June 2008<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Priming Recommendation<br />
<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong><br />
Published 06/2009<br />
applicable = �<br />
This table represents a guide for the user and should be regarded only as a recommendation. Depending on the building, it may be necessary<br />
to carry out suitability tests (individual testing), because the overall structure must always be considered. All substrates must be evenly solid<br />
and free of separating substances (oil, seperating agents, free granules - see also TI 21). Other substrates not listed here must always be<br />
checked with regard to their adhesion performance.<br />
Substrate<br />
<strong>KEMPER</strong>TEC<br />
EP- / EP5-<br />
Primer<br />
<strong>KEMPER</strong>TEC<br />
D- / R-<br />
Primer<br />
Bitumen roof sheet<br />
(V 13, V 60, G 200, PYE (SBS)) � �<br />
<strong>KEMPER</strong>TEC<br />
FPO-Primer<br />
<strong>KEMPER</strong>TEC<br />
<strong>1K</strong>-Primer<br />
4 4,8 �<br />
APP-Bitumen roof sheet, granulated Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing<br />
Asphalt, weathered<br />
�<br />
4 � 4<br />
Plastic sheets (EPDM, ECB, PVC-P, PE, PP, PIB, EVA) Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing<br />
FPO- or TPO-Plastic sheets �<br />
Fibre-cement sheets<br />
� �<br />
Clinker, Bricks,<br />
visible brickwork stones (grinded) � �<br />
Concrete, screed<br />
Plastic-modified screed and mortar (PCC)<br />
Stones for construction (lightweight, gas or pumice concrete,<br />
cement and calcareous sandstone) �<br />
Glass (uncoated) - MEK cleaned<br />
Zinc, galvanised steel<br />
Copper, lead<br />
Steel, special steels (V2A, V4A), Aluminium<br />
Insulating materials (polystyrene, rock wool)<br />
Insulating materials (polyurethane)<br />
Wood panels, plywood, chipboard, OSB<br />
4 4,8 �<br />
4 4,8 �<br />
� 4,8 �<br />
�<br />
�<br />
Indiv. Testing<br />
Indiv. Testing Indiv. Testing<br />
Indiv. Testing<br />
2,3,4 � �<br />
�<br />
2 �<br />
2 2,3,4 �<br />
2 2,3,4 �<br />
2,3 2,3,4 2,3,4<br />
� �<br />
�<br />
�<br />
�<br />
4,6 4,6 4,6<br />
�<br />
�<br />
4,6 4,6 4,6<br />
�<br />
�<br />
4,6 � �4,6<br />
2 Mechanical pre-treatment and cleaning with <strong>KEMPER</strong>TEC® MEK Cleaning Agent necessary.<br />
3 Low adhesion – additional mechanical fastening is recommended.<br />
4 Areas with a minimum overlap larger than 15 cm necessary.<br />
6 Partition layer required!<br />
8 Consider Technical Data Sheet <strong>KEMPER</strong>TEC® <strong>1K</strong>-Primer<br />
When using this priming table, it is necessary to follow <strong>KEMPER</strong> <strong>SYSTEM</strong> preparation guidelines and technical advice. Please observe our warranty clause for application-related<br />
consultation.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>TEC ® D-<br />
Primer<br />
Uses<br />
� For priming and durable adhesion between the pretreated<br />
substrate and <strong>KEMPER</strong>OL ® waterproofing<br />
membranes.<br />
� For new construction and remedial projects<br />
Features<br />
� universal use (see priming recommendations)<br />
� solvent-free<br />
� excellent adhesion<br />
CE-Marking<br />
Component to 1 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
A solvent-free, 2-component primer based on<br />
polyurethane resin.<br />
Pack sizes<br />
2 * 1,0 kg sachets in a plastic bucket<br />
2 * 2,5 kg sachets in a plastic bucket<br />
Shelf Life<br />
Can be stored unopened for up to 12 months in a<br />
cool, dry, frost-free place.<br />
Usage guide<br />
Depending on the nature and condition of the<br />
substrate approx. 500 g/m².<br />
Properties<br />
Form liquid<br />
Colour Comp. A cream<br />
Comp. B dark<br />
brown<br />
Workability period* [min] approx. 25<br />
Rainproof* after [h] approx. 3<br />
Can be walked on* after [h] approx. 12<br />
Next coat can be applied after* [h] approx. 12<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Application<br />
The substrate must be dry, sound and free from any<br />
material that would hinder adhesion. Prepare the<br />
substrate according to Technical Information Tl 21 -<br />
Substrate Preparation.The priming recommendations<br />
should be followed.<br />
Prime only when substrate and ambient temperature<br />
exceed 5 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the dew point is not reached, the surface to be<br />
primed can form a moisture film and cause separation<br />
(DIN 4108 - 5 Tab.1).
Remove the bag from the aluminium packaging.<br />
Knead component A (cream/white coloured)<br />
thoroughly (until uniform colour achieved). Pull away<br />
the rubber cord separating the two components, so<br />
that both components A and B can be mixed together.<br />
Now knead the bag quickly and thoroughly (approx. 60<br />
secs.) so that a homogenous, streak-free primer is<br />
formed.<br />
Cut off one corner of the bag and pour the<br />
<strong>KEMPER</strong>TEC ® D-Primer onto the surface and work<br />
quickly.<br />
Apply the primer evenly with a nylon roller until the<br />
pores are closed. Distribute with a nylon roller avoiding<br />
accumulation of material.<br />
After approximately 12 hours (depending on weather<br />
conditions, such as wind, ambient temperature and<br />
humidity) and provided that the primed surface is tackfree<br />
and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />
products can be applied.<br />
Important note:<br />
<strong>KEMPER</strong>TEC ® D-Primer must be overcoated within 8<br />
days of application, otherwise adhesion of subsequent<br />
coats cannot be guaranteed and repriming will be<br />
necessary. To avoid this, <strong>KEMPER</strong>DUR ® NQ 0408<br />
Natural Quartz (approx. 2 kg/m²), should be strewed<br />
into the wet primer, allowing recoating to take place<br />
unhindered after this 8 day period.<br />
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 21 - substrate preparation<br />
Important notice<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground.<br />
Cannot be used in swimming pools!<br />
Disposal<br />
Components A+B liquid EWC 08 04 09<br />
Components A+B cured EWC 08 04 10<br />
GISCODE<br />
PU40<br />
General information<br />
The times given are reduced with higher and<br />
increased with lower surrounding and work surface<br />
temperatures.<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>TEC ® EP-<br />
Primer<br />
Uses<br />
� For priming and durable adhesion between the pretreated<br />
substrate and <strong>KEMPER</strong>OL ® waterproofing<br />
membranes.<br />
� As bonding agent for trowel-applied levelling and<br />
repair mortar<br />
� For making an alkaline protection layer<br />
� For making a bonding coat with <strong>KEMPER</strong>TEC ® NQ<br />
0408 before applying the <strong>KEMPER</strong>DUR ® Sand<br />
Coating or <strong>KEMPER</strong>DUR ® Decor Stone<br />
� For new construction and remedial projects<br />
Features<br />
� universal use (see priming recommendations)<br />
� solvent-free<br />
� excellent adhesion<br />
� high penetration capability<br />
CE-Marking<br />
Component to 1 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
2-component primer based on epoxy resin.<br />
Pack sizes<br />
2 * 1,5 kg sachets in a plastic bucket<br />
10 kg in a tin container<br />
Shelf Life<br />
Can be stored unopened for up to 12 months in a cool,<br />
dry, frost-free place. At temperatures below 5 °C ,<br />
crystallisation may occur. This can be reversed by<br />
careful heating (40 °C).<br />
Properties<br />
Form liquid<br />
Colour Comp. A yellowish<br />
Comp. B brownish<br />
Workability period* [min] approx. 25<br />
Rainproof* after [h] approx. 6<br />
Can be walked on* after [h] approx. 16<br />
Next coat can be applied after*<br />
[h]<br />
approx. 16<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Usage guide<br />
Depending on the nature and condition of the<br />
substrate: as primer approx. 500 g/m²<br />
as a bonding coat approx. 300-500 g/m²<br />
as alkaline protection approx. 400-600 g/m².<br />
Application<br />
The substrate must be dry (in concrete, the residual<br />
moisture in the upper 2 cm must be < 5 %), sound and<br />
free from any material that would hinder adhesion.<br />
Prepare the substrate according to Technical<br />
Information Tl 21 - Substrate Preparation. The priming<br />
recommendations should be followed.<br />
Prime only when substrate and ambient temperature<br />
exceed 10 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the dew point is not reached, the surface to be<br />
primed can form a moisture film and cause separation<br />
(DIN 4108 - 5 Tab.1).
A. Packaging: 1,5 kg-sachet:<br />
Remove the bag from the aluminium packaging. Pull<br />
away the rubber cord separating the two components,<br />
so that both components A and B can be mixed<br />
together. Now knead the bag quickly and thoroughly<br />
(approx. 60 secs.) so that a homogenous, streak-free<br />
primer is formed.<br />
Cut off one corner of the bag and pour the<br />
<strong>KEMPER</strong>TEC ® EP-Primer onto the surface and work<br />
quickly.<br />
B. Packaging: 10 kg-tin container<br />
Mix component B into component A thoroughly with a<br />
stirring stick or a power drill on a slow speed. The<br />
mixture should be a uniform colour, free from streaks.<br />
Mixing time is approximately 2 minutes. Apply within 25<br />
minutes.<br />
To avoid mixing errors, the complete mixture should be<br />
poured into another container and stirred again<br />
thoroughly.<br />
Apply the primer evenly with a perlon roller, ensuring<br />
complete substrate coverage and avoiding<br />
accumulation of material.<br />
Use as a primer and bonding coat<br />
Apply the primer until the pores are closed and<br />
immediately sand with <strong>KEMPER</strong>DUR ® NQ 0408<br />
Natural Quartz ensuring full coverage (usage approx. 1<br />
- 2 kg/m²). After approximately 16 hours (depending on<br />
weather conditions, such as wind, ambient temperature<br />
and humidity) and provided that the primed surface is<br />
tack-free and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />
products can be applied.<br />
Use as trowel-applied levelling mortar<br />
Before application of the mortar, <strong>KEMPER</strong>TEC ® EP-<br />
Primer should be applied to the substrate.<br />
<strong>KEMPER</strong>TEC ® EP-Primer is mixed with<br />
<strong>KEMPER</strong>TEC ® <strong>KEMPER</strong>TEC ® KR Quartz Sand<br />
Mixture in a ratio of 1 : 4 and applied to the prepared<br />
and primed substrate to fill voids between 2 and 6 mm.<br />
Use as a trowel-applied repair mortar<br />
Before application of the repair mortar, <strong>KEMPER</strong>TEC ®<br />
EP-Primer should be applied to the substrate.<br />
<strong>KEMPER</strong>TEC ® EP-Primer is mixed with<br />
<strong>KEMPER</strong>TEC ® <strong>KEMPER</strong>TEC ® KR Quartz Sand<br />
Mixture in a ratio of 1 : 9 to fill cracks and voids of up to<br />
20 mm in depth. The mixing ratio can vary depending<br />
on substrate condition.<br />
Use as alkali protection layer:<br />
To form an alkali-resistant barrier (see also Technical<br />
Information TI 15 - Alkalinity), apply a coat of<br />
<strong>KEMPER</strong>TEC ® EP-Primer to the <strong>KEMPER</strong>OL ®<br />
waterproofing membrane (approx. 400-600 g/m²).<br />
Immediately after application, strew in approx. 500 -<br />
1000 g/m² <strong>KEMPER</strong>DUR ® NQ 0712 Natural Quartz,<br />
ensuring full surface coverage.<br />
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 15 - alkalinity<br />
- TI 21 - substrate preparation<br />
Important notice<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground.<br />
Cannot be used in swimming pools!<br />
Disposal<br />
Components A+B liquid EWC 08 04 09<br />
Components A+B cured EWC 08 04 10<br />
GISCODE<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001<br />
RE1<br />
General information<br />
The times given are reduced with higher and increased<br />
with lower surrounding and work surface temperatures.<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009
<strong>KEMPER</strong>TEC ® EP5-<br />
Primer<br />
Uses<br />
� For priming and durable adhesion between the pretreated<br />
substrate and <strong>KEMPER</strong>OL ® waterproofing<br />
membranes.<br />
� As bonding agent for trowel-applied filler and repair<br />
mortar<br />
� As alkaline protection<br />
� For making a bonding coat with <strong>KEMPER</strong>TEC ® NQ<br />
0408 before applying the <strong>KEMPER</strong>DUR ® Sand<br />
Coating or <strong>KEMPER</strong>DUR ® Decor Stone<br />
� For new construction and remedial projects<br />
Features<br />
� solvent-free<br />
� excellent adhesion<br />
� curing at low temperature<br />
CE-Marking<br />
Component to 1 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
2-component primer based on epoxy resin.<br />
Pack sizes<br />
2 * 1,5 kg sachets in a plastic bucket<br />
10 kg in a tin container<br />
Shelf Life<br />
Can be stored unopened for up to 12 months in a cool,<br />
dry, frost-free place.<br />
Usage guide<br />
Depending on the nature and condition of the<br />
substrate: as a primer approx. 500 g/m²<br />
as a bonding coat approx. 300-500 g/m²<br />
as alkaline protection approx. 400-600 g/m².<br />
Properties<br />
Form liquid<br />
Colour Comp. A transparent<br />
Comp. B yellowish<br />
Workability period* [min] approx. 20<br />
Rainproof* after [h] approx. 3<br />
Can be walked on* after [h] approx. 4<br />
Next coat can be applied<br />
after* [h]<br />
approx. 4<br />
* Values obtained at a temperature of 23 °C - 50% rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Application<br />
The substrate must be dry (in concrete, the residual<br />
moisture in the upper 2 cm must be < 5 %), sound and<br />
free from any material that would hinder adhesion and<br />
must be prepared according to Technical Information TI<br />
21 - Substrate Preparation. The priming<br />
recommendations should be followed.<br />
Prime only when substrate and ambient temperature<br />
exceed 5 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the dew point is not reached, the surface to be<br />
primed can form a moisture film and cause separation<br />
(DIN 4108 - 5 Tab.1).<br />
A. Packaging: 1.5 kg-sachet<br />
Remove the bag from the aluminium packaging. Pull<br />
away the rubber cord separating the two components,<br />
so that both components A and B can be mixed<br />
together. Now knead the bag quickly and thoroughly<br />
(approx. 60 secs.) so that a homogenous, streak-free<br />
primer is formed.
Cut off one corner of the bag and pour the<br />
<strong>KEMPER</strong>TEC ® EP5-Primer onto the surface and work<br />
quickly.<br />
B. Packaging: 10 kg-tin container<br />
Mix component B into component A thoroughly with a<br />
stirring stick or a power drill on a slow speed. The<br />
mixture should be a uniform colour, free from streaks.<br />
Mixing time is approximately 2 minutes. Apply within 15<br />
minutes.<br />
To avoid mixing errors, the complete mixture should be<br />
poured into another container and stirred again<br />
thoroughly.<br />
Apply the primer evenly with a perlon roller, ensuring<br />
complete substrate coverage and avoiding<br />
accumulation of material.<br />
Use as primer and bonding coat<br />
Apply the primer until the pores are closed and<br />
immediately sand with <strong>KEMPER</strong>DUR ® NQ 0408<br />
Natural Quartz ensuring full coverage (usage approx.<br />
500 - 1000 g/m²). After approximately 4 hours and<br />
provided that the primed surface is tack-free and dry,<br />
further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong> products can be<br />
applied.<br />
Use as trowel-applied levelling mortar<br />
Before application of the mortar, <strong>KEMPER</strong>TEC ® EP5-<br />
Primer should be applied to the substrate.<br />
<strong>KEMPER</strong>TEC ® EP5-Primer is mixed with<br />
<strong>KEMPER</strong>TEC ® <strong>KEMPER</strong>TEC ® KR Quartz Sand<br />
Mixture in a ratio of 1 : 2 and applied to the prepared<br />
and primed substrate to fill voids between 2 and 6 mm.<br />
Use as a trowel-applied repair mortar<br />
Before application of the repair mortar, <strong>KEMPER</strong>TEC ®<br />
EP5-Primer should be applied to the substrate.<br />
<strong>KEMPER</strong>TEC ® EP5-Primer is mixed with<br />
<strong>KEMPER</strong>TEC ® KR Quartz Sand Mixture in a ratio of 1 :<br />
5 to fill cracks and voids of up to 20 mm in depth. The<br />
mixing ratio can vary depending on substrate condition.<br />
Use as alkali protection layer:><br />
To form an alkali-resistant barrier (see also Technical<br />
Information TI 15 - Alkalinity), apply a coat of<br />
<strong>KEMPER</strong>TEC ® EP5-Primer (approx. 400-600 g/m²) to<br />
the <strong>KEMPER</strong>OL ® waterproofing membrane.<br />
Immediately after application, strew in approx. 500 -<br />
1000 g/m² <strong>KEMPER</strong>DUR ® NQ 0712 Natural Quartz,<br />
ensuring full surface coverage.<br />
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 15 - alkalinity<br />
- TI 21 - substrate preparation<br />
Important notice<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground.<br />
Cannot be used in swimming pools!<br />
Disposal<br />
Components A+B liquid EWC 08 04 09<br />
Components A+B cured EWC 08 04 10<br />
GISCODE<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001<br />
RE1<br />
General information<br />
The times given are reduced with higher and increased<br />
with lower surrounding and work surface temperatures.<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009
<strong>KEMPER</strong>TEC ® <strong>1K</strong>-<br />
Primer<br />
Uses<br />
� For priming and durable adhesion between the pretreated<br />
substrate and <strong>KEMPER</strong>OL ® waterproofing<br />
membranes.<br />
� For making a bonding coat with <strong>KEMPER</strong>TEC ® NQ<br />
0408 before applying the <strong>KEMPER</strong>DUR ® Sand<br />
Coating or <strong>KEMPER</strong>DUR ® Decor Stone<br />
� For new construction and remedial projects<br />
Features<br />
� quickly drying<br />
� excellent adhesion<br />
CE-Marking<br />
Component to 1 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
Based on isocyanate-prepolymers, dissolved in organic<br />
solvents.<br />
Pack sizes<br />
5 kg<br />
Shelf Life<br />
Can be stored unopened for up to 6 months in a cool,<br />
dry, frost-free place.<br />
Properties<br />
Form liquid<br />
Colour yellowish-clear<br />
Workability period* [min] approx. 30<br />
Rainproof* after [min] approx. 60<br />
Can be walked on* after [h] approx. 2-3<br />
Next coat can be applied after* [h] approx. 2-3<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Usage guide<br />
Depending on the absorbency of the substrate:<br />
150-300 g/m²<br />
Application<br />
The substrate must be dry (in concrete, the residual<br />
moisture in the upper 2 cm must be < 5 %), sound and<br />
free from any material that would hinder adhesion.<br />
Prepare the substrate according to Technical<br />
Information Tl 21 - Substrate Preparation. The priming<br />
recommendations should be followed.<br />
Warning: <strong>KEMPER</strong>TEC ® <strong>1K</strong>-Primer is not appropriate<br />
for every substrate!<br />
Apply only when substrate and ambient temperatures<br />
exceed 5 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the substrate temperature is below or at the<br />
dew point temperature then moisture can form at the<br />
surface which can affect coating adhesion and cure.<br />
(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />
graph).<br />
Prime in one operation until the pores are closed.<br />
Distribute with a nylon roller so that material<br />
accumulation is avoided. Otherwise the substrate may<br />
be dissolved.<br />
After approximately 1 hour (depending on weather<br />
conditions, such as wind, ambient temperature and<br />
humidity) and provided that the primed surface is tackfree<br />
and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />
products can be applied. This must be completed<br />
within the next 48 hours or separating effects may
occur.<br />
To avoid these separating effects, we recommend<br />
sanding the fresh <strong>KEMPER</strong>TEC ® <strong>1K</strong>-Primer with<br />
<strong>KEMPER</strong>TEC ® NQ 0408 Natural Quartz (approx.<br />
2kg/m²). Otherwise, it is necessary to re-prime after 48<br />
hours.<br />
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 21 - substrate preparation<br />
- TI 23 - solvent-based products<br />
Caution: Bitumenous substrates can be dissolved,<br />
therefore material accumulation (puddles) must be<br />
avoided.<br />
Important notice<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground.<br />
Cannot be used in swimming pools!<br />
Disposal<br />
liquid EWC 08 04 09<br />
cured EWC 08 04 10<br />
GISCODE<br />
PU50<br />
General information<br />
The times given are reduced with higher and increased<br />
with lower surrounding and work surface temperatures.<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>TEC ® R-<br />
Primer<br />
Uses<br />
� For priming and durable adhesion between the pretreated<br />
substrate and <strong>KEMPER</strong>OL ® waterproofing<br />
membranes.<br />
� For new construction and remedial projects<br />
Features<br />
� solvent-free<br />
� excellent adhesion<br />
� fast curing<br />
CE-Marking<br />
Component to 1 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
A solvent-free, 2-component primer based on<br />
polyurethane resin.<br />
Pack sizes<br />
2 * 1,0 kg sachets in a plastic bucket<br />
Shelf Life<br />
Can be stored unopened for up to 12 months in a cool,<br />
dry, frost-free place.<br />
Properties<br />
Form liquid<br />
Colour Comp. A cream<br />
Comp. B dark brown<br />
Workability period* [min] approx. 8<br />
Rainproof* after [h] approx. 2<br />
Can be walked on* after [h] approx. 2-3<br />
Next coat can be applied<br />
after* [h]<br />
approx. 2-3<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Usage guide<br />
Depending on the nature and condition of the<br />
substrate: approx. 500 g/m².<br />
Application<br />
The substrate must be dry, sound and free from any<br />
material that would hinder adhesion. Prepare the<br />
substrate according to Technical Information Tl 21 -<br />
Substrate Preparation. The priming recommendations<br />
should be followed.<br />
Apply only when substrate and ambient temperatures<br />
exceed 5 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the substrate temperature is below or at the<br />
dew point temperature then moisture can form at the<br />
surface which can affect coating adhesion and cure.<br />
(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />
graph).<br />
Remove the bag from the aluminium packaging.<br />
Knead component A (cream/white coloured)<br />
thoroughly (until uniform colour achieved). Pull away<br />
the rubber cord separating the two components, so<br />
that both components A and B can be mixed together.<br />
Now knead the bag quickly and thoroughly (approx. 60<br />
secs.) so that a homogenous, streak-free primer is<br />
formed.<br />
Cut off one corner of the bag and pour the<br />
<strong>KEMPER</strong>TEC ® R-Primer onto the surface and work<br />
quickly.<br />
Prime at least once until saturated. Spread out evenly<br />
using a nylon roller, avoiding any build-up of material.<br />
After approximately 2-3 hours (depending on weather<br />
conditions, such as wind, ambient temperature and
humidity) and provided that the primed surface is tackfree<br />
and dry, further suitable <strong>KEMPER</strong> <strong>SYSTEM</strong><br />
products can be applied.<br />
Important note:<br />
<strong>KEMPER</strong>TEC ® R-Primer must be overcoated within 8<br />
days of application, otherwise adhesion of subsequent<br />
coats cannot be guaranteed and re-priming will be<br />
necessary. To avoid this, <strong>KEMPER</strong>DUR ® NQ 0408<br />
Natural Quartz (approx. 2 kg/m²) should be strewed<br />
into the wet primer, allowing recoating to take place<br />
unhindered after this 8 days period.<br />
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 21 - substrate preparation<br />
Important notice<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground.<br />
Cannot be used in swimming pools!<br />
Disposal<br />
Components A+B liquid EWC 08 04 09<br />
Components A+B cured EWC 08 04 10<br />
GISCODE<br />
PU40<br />
General information<br />
The times given are reduced with higher and<br />
increased with lower surrounding and work surface<br />
temperatures. We guarantee the consistent high<br />
quality of our products. <strong>KEMPER</strong> <strong>SYSTEM</strong> products<br />
must not be mixed with other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>TEC ® FPO-<br />
Primer<br />
Uses<br />
� For excellent adhesion between polyolefin plastics<br />
(FPO/TPO) and following <strong>KEMPER</strong>OL ® products<br />
- <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> System<br />
- <strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong> <strong>Waterproofing</strong> System<br />
� For new construction and remedial projects<br />
Features<br />
� Quickly drying<br />
� Excellent adhesion on FPO sheets<br />
Composition<br />
Bonding agent dissolved in toluene.<br />
Pack sizes<br />
500 g, 1 kg und 3 kg units.<br />
Shelf Life<br />
Can be stored unopened for up to 6 months in a cool,<br />
dry, frost-free place.<br />
Properties<br />
Form liquid<br />
Colour transparent<br />
Workability period* [min] approx. 5<br />
Rainproof* after [min] approx. 30<br />
Can be walked on* after [min] approx. 30<br />
Next coat can be applied after*<br />
[min]<br />
approx. 30<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Usage guide<br />
Depending on the nature of the substrate: approx. 50<br />
g/m².<br />
Application<br />
The substrate must be dry, sound and free from any<br />
material that would hinder adhesion and must be<br />
prepared according to Technical Information TI 21 -<br />
Substrate Preparation.<br />
Clean surface with <strong>KEMPER</strong>TEC ® MEK Cleaning<br />
Agent.<br />
Warning: <strong>KEMPER</strong>TEC ® FPO-Primer is not<br />
appropriate for every substrate!<br />
This primer is especially developed for polyolefin<br />
plastics!<br />
Apply only when substrate and ambient temperatures<br />
exceed 5 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the substrate temperature is below or at the<br />
dew point temperature then moisture can form at the<br />
surface which can affect coating adhesion and cure.<br />
(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />
graph).<br />
Prime in one operation until the pores are closed.<br />
Distribute with a perlon roller so that material<br />
accumulation is avoided.<br />
Provided that the primer is dry and tack-free,<br />
additional suitable <strong>KEMPER</strong> <strong>SYSTEM</strong> waterproofing<br />
products (<strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong> and <strong>KEMPER</strong>OL ®<br />
<strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>) should be applied after 15 -<br />
30 minutes - depending on the weather conditions,<br />
wind humidity and temperature. The <strong>KEMPER</strong>OL ®<br />
membrane has to be applied within the next 24 hours<br />
or separating effects can occur.
Personal protective equipment should be worn.<br />
Clean the tools immediately after use with<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent. Clean your<br />
hands and rub <strong>KEMPER</strong> <strong>SYSTEM</strong> skin care cream<br />
into the skin.<br />
Remark<br />
Please consider the following technical information:<br />
- TI 21 - substrate preparation<br />
- TI 23 - solvent-based products<br />
Important notice<br />
Adhesion tests on other plastic sheets (EPDM, PIB<br />
etc..) have already been made. Before applying the<br />
FPO primer on further sheets please consult <strong>KEMPER</strong><br />
<strong>SYSTEM</strong> Ltd.!<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground.<br />
Cannot be used in swimming pools!<br />
Disposal<br />
Liquid EWC 08 04 09<br />
Cured EWC 08 04 10<br />
General information<br />
The times given are reduced with higher and<br />
increased with lower surrounding and work surface<br />
temperatures.<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, August 2009<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
<strong>KEMPER</strong>TEC ® MEK<br />
Cleaning Agent<br />
Uses<br />
� Cleaning agent to clean <strong>KEMPER</strong>OL ® surfaces after<br />
a break for more than 6 hrs or for the re-treatment of<br />
existing waterproofing membranes after a longer<br />
period of time<br />
� To clean tools<br />
� To clean substrates<br />
� To remove fat or oil from metals<br />
Features<br />
� specific effectiveness<br />
� evaporates quickly<br />
CE-Marking<br />
Component to 1 ETA 03/0025<br />
ETA 03/0026<br />
ETA 03/0043<br />
ETA 03/0044<br />
Composition<br />
Organic solvent mixture.<br />
Pack sizes<br />
2 kg, 9 kg and 23 kg<br />
Shelf Life<br />
Store in a cool and dry environment.<br />
Properties<br />
Form liquid<br />
Colour clear<br />
Usage guide<br />
Depending on the degree of soiling approx. 200 g/m²<br />
Application<br />
Apply <strong>KEMPER</strong>TEC ® MEK Cleaning Agent by cloth to<br />
previously <strong>KEMPER</strong>OL ® pre-treated surfaces or soiled<br />
substrates, avoiding puddles of material. After<br />
cleaning, remove all residual cleaner.<br />
Before additional coating, ventilate the area well.<br />
For application in enclosed areas ensure there is<br />
sufficient ventilation.<br />
Caution: Danger of explosion!<br />
Personal protective equipment should be worn.<br />
Important notice<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent is to be used<br />
only for the cleaning of tools and surfaces.<br />
Caution: Plastic surfaces (acrylic glass, etc.) can be<br />
dissolved.<br />
The safety data sheets, identification of the units,<br />
hazard warnings and safety recommendations on the<br />
units must be observed during transportation, storage<br />
and application. The BG-Chemie technical information<br />
must be observed for application.<br />
Do not allow into the sewer system or into the ground!<br />
Disposal<br />
liquid EWC 07 02 04<br />
GISCODE<br />
GF40
General information<br />
We guarantee the consistent high quality of our<br />
products.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> products must not be mixed with<br />
other manufacturers´ products.<br />
The technical information and application instructions contained herein<br />
reflect the current level of knowledge and experience with our products.<br />
In each case, the new edition supersedes the previous technical<br />
information and renders it invalid. It is therefore necessary that you<br />
always have to hand the current code of practice. When using our<br />
products, a detailed, object-related and qualified inspection is required in<br />
each individual case in order to determine whether the product and / or<br />
application technology in question meets the specific requirements and<br />
purposes. We are liable only for our products being free from faults -<br />
correct application of our products therefore falls entirely within your<br />
scope of liability and responsibility. Our products are sold exclusively on<br />
the basis of our conditions of sale and delivery.<br />
Published: Vellmar, June 2008<br />
______________________________________________________________________________________________________________<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Technical Information 23<br />
The use of products containing solvents<br />
If porous or absorbent substrates (concrete < grade B15, concrete with lightweight<br />
aggregates, aerated concrete blocks, calcium silicate bricks, autoclaved aerated concrete,<br />
clay bricks, timber, etc.) . adjacent to occupied interior spaces . are to be treated with a<br />
<strong>KEMPER</strong>OL ® waterproofing system or a <strong>KEMPER</strong>DUR® coating system, please note the<br />
following points:<br />
� <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ® products containing solvents may not be used directly<br />
on porous or absorbent substrates! (Possibility of solvent odours inside the<br />
� building)<br />
� Check the possibility of using solvent-free products.<br />
� Generally, make good all open joints, gaps, etc. or large areas of damage before<br />
beginning work.<br />
� If, nevertheless, products containing solvents are to be used, prime the entire<br />
substrate first with two coats of solvent-free <strong>KEMPER</strong>TEC ® EP-Primer or <strong>KEMPER</strong>TEC ®<br />
EP5-Primer to close all the pores. Work a layer of fine sand into the second coat.<br />
� Products containing solvents must be applied only in the thickness specified on the<br />
technical data sheets.<br />
� When applying solvents containing <strong>KEMPER</strong>TEC ® , <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ®<br />
products indoors or around windows, doors or the intakes to air-conditioning<br />
systems, fans, etc., please take all necessary safety precautions! (Switch off airconditioning,<br />
use fresh and exhaust-air plant, etc.)<br />
� Provide occupants and users with all necessary information about the work well in<br />
advance.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Solvents containing <strong>KEMPER</strong>TEC ® , <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ® products are:<br />
<strong>KEMPER</strong>TEC ® <strong>1K</strong>-Primer <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>KEMPER</strong>DUR ® Deko<br />
<strong>KEMPER</strong>TEC ® AC-Primer <strong>KEMPER</strong>OL ® AC <strong>KEMPER</strong>DUR Deko trans.<br />
<strong>KEMPER</strong>TEC ® FPO-Primer <strong>KEMPER</strong>OL ® BR <strong>KEMPER</strong>DUR ® Finish matt<br />
<strong>KEMPER</strong>TEC ® MEK Cleaning Agent <strong>KEMPER</strong>OL ® V 210 <strong>KEMPER</strong>DUR Finish glossy<br />
<strong>KEMPER</strong>OL ® V 210 M <strong>KEMPER</strong>DUR ® QB1 Binder<br />
<strong>KEMPER</strong>DUR ® AC Finish<br />
Note: This edition supersedes all previous editions of this Technical Information.<br />
Vellmar, June 2008<br />
The technical information and application instructions contained herein reflect the current level of knowledge<br />
and experience with our products. In each case, the new edition supersedes the previous technical information<br />
and renders it invalid. It is therefore necessary that you always have to hand the current code of practice. When<br />
using our products, a detailed, object-related and qualified inspection is required in each individual case in order<br />
to determine whether the product and / or application technology in question meets the specific requirements<br />
and purposes. We are liable only for our products being free from faults – correct application of our products<br />
therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively on the<br />
basis of our conditions of sale and delivery.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Technical Information 15<br />
Protecting against alkalinity of <strong>KEMPER</strong>OL ® and <strong>KEMPER</strong>DUR ® Products<br />
Without appropriate protection, <strong>KEMPER</strong> <strong>SYSTEM</strong> liquid polymer- or polyurethane-based<br />
products exhibit inadequate long-term resistance to media with extreme pH values and,<br />
therefore, must be protected against the damaging effects of alkaline media.<br />
On building sites there are many products exhibiting alkaline reactions, e.g. screeds,<br />
concrete, tile adhesives, etc. These materials contain large proportions of cement, whose<br />
principal constituent is calcium hydroxide, although there are also small amounts of sodium<br />
hydroxide. Dissolved in water (electrolytic dissociation), this sodium hydroxide exhibits a<br />
strongly alkaline reaction (up to pH 14).<br />
This means that when a product containing cement is placed directly on a <strong>KEMPER</strong>OL or<br />
<strong>KEMPER</strong>DUR product, e.g. a screed laid to falls or ceramic finishes laid in a mortar bed, over<br />
the long term there is the risk of damaging the waterproofing or coating system. In<br />
chemical terms this process is known as saponification. The saponification leads to<br />
embrittlement of the waterproofing or coating system, which reduces its elasticity.<br />
Adequate protection can be achieved only by applying a an alkaline protection layer on<br />
the cured waterproofing or coating membrane.<br />
On one-component products (e. g. <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong>, <strong>KEMPER</strong>DUR ® Deko) the alkaline<br />
protection layer can be applied after 3 to 7 days, on two-component products (e. g.<br />
<strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong>, <strong>KEMPER</strong>OL ® V 210, <strong>KEMPER</strong>DUR ® Deko 2K) the alkaline protection<br />
layer can be applied after one day.<br />
After this period of time, the <strong>KEMPER</strong>TEC ® EP-Primer, <strong>KEMPER</strong>TEC ® EP5-Primer or<br />
<strong>KEMPER</strong>TEC ® AC-Primer can be applied to the surface.<br />
This can be carried out in one operation with a thick coating, approx. 400-600 g/m2<br />
(<strong>KEMPER</strong>TEC ® AC Primer: max. 500 g/m²). <strong>KEMPER</strong>TEC ® NQ 0712 Natural Quartz is spread<br />
liberally (leaving no gaps) over the primer while it is still wet.<br />
However, in order to avoid imperfections in the protective layer, it is better to apply two<br />
coats of <strong>KEMPER</strong>TEC ® EP-Primer, <strong>KEMPER</strong>TEC ® EP5-Primer or <strong>KEMPER</strong>TEC ® AC-Primer each<br />
coat approx. 200-300 g/m2. With <strong>KEMPER</strong>TEC ® EP-Primer wait for one day, with<br />
<strong>KEMPER</strong>TEC ® EP5-Primer for 4 hours, with <strong>KEMPER</strong>TEC ® AC Primer for one hour before<br />
applying the second coat. Before the second coat is dry, <strong>KEMPER</strong>TEC ® NQ 0712 Natural<br />
Quartz is spread liberally (leaving no gaps) over the primer.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
With <strong>KEMPER</strong>TEC ® EP-Primer, the protective layer must be allowed to cure for at least three<br />
days at 20 °C, with <strong>KEMPER</strong>TEC ® EP5-Primer wait for two days and with <strong>KEMPER</strong>TEC ® AC for<br />
one day before any alkaline-reactive media, e.g. screeds etc., are laid on top. Lower<br />
temperatures call for a longer curing time.<br />
Note: This edition supersedes all previous editions of this Technical Information.<br />
Vellmar, June 2008<br />
The technical information and application instructions contained herein reflect the current level of knowledge<br />
and experience with our products. In each case, the new edition supersedes the previous technical information<br />
and renders it invalid. It is therefore necessary that you always have to hand the current code of practice. When<br />
using our products, a detailed, object-related and qualified inspection is required in each individual case in order<br />
to determine whether the product and / or application technology in question meets the specific requirements<br />
and purposes. We are liable only for our products being free from faults – correct application of our products<br />
therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively on the<br />
basis of our conditions of sale and delivery.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Technical Information 21<br />
Checking – Assessing – Preparing the substrate<br />
General<br />
The most important requirement for the success and long-term adhesion of <strong>KEMPER</strong><br />
<strong>SYSTEM</strong> products is the bond with the substrate and its testing, assessment and<br />
preparation. Ignoring this requirement is the most common cause of defective<br />
workmanship, defects and complaints.<br />
Balconies, terraces and patios can have many different substrates, e.g. old ceramic tiles,<br />
mastic asphalt, old paint, or concrete/screeds. According to the requirements of DIN 18365<br />
"Flooring works", any substrate that is to be waterproofed must be firm, clean and free<br />
from all loose material, dust, dirt, oil and grease.<br />
According to the German Contract Procedures for Building Works (VOB), the contractor<br />
must test the substrate to ascertain its suitability for the specified covering. The contractor<br />
should inform the client immediately in writing if he has any doubts about the suitability<br />
of the substrate for the specified works.<br />
Checking the moisture content of the substrate<br />
In all cases, the moisture content of the top 20 mm of substrate may not exceed 5%. In the case<br />
of a fresh cement screed or concrete surfaces, a coating is not possible until the moisture<br />
content (equilibrium moisture content) of the material has dropped below 5%. This is usually<br />
not until 28 days after laying the screed or placing the concrete.<br />
In the case of substrates in contact with the soil, they must be adequately isolated against<br />
groundwater and rising damp (capillary moisture), e.g. by means of a layer of gravel (filter)<br />
plus a damp-proof membrane (dpm). So-called waterproof concrete and waterproofing<br />
screeds do not represent adequate protection because they are still permeable to water<br />
vapour.<br />
A chilled mirror hygrometer can be used to measure the moisture content. Rising damp can<br />
be checked by covering an area of approx. 1 m 2 with dense polyethylene sheeting. If the<br />
covered area turns a dark colour within 24 hours, rising damp is to be expected.<br />
Checking the strength of the substrate<br />
In all cases, the substrate must possess adequate strength.<br />
The compressive strength of concrete and screeds can be determined with a rebound hammer<br />
(Schmidt hammer). A value of min. 30 N/mm 2 is essential. The pull-off strength is determined<br />
with an adhesive strength tester. The value must be min. 1.5 N/mm 2 .<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004
<strong>KEMPER</strong>OL ® waterproofing systems are elastic, have a high inherent strength and can bridge<br />
over cracks, but as they are very thin (approx. 2 mm), they cannot perform a load-distributing<br />
function.<br />
Preparing the substrate<br />
The substrate should be prepared in such a way that a permanent, strong bond is achieved<br />
between the system to be applied and the substrate. To achieve this, the substrate must be<br />
consistently firm and free from all separating substances, sharp edges, burrs, flashes, fins, etc.<br />
The choice of a suitable preparatory method depends on the condition of the existing surface,<br />
the specification and the waterproofing system to be applied.<br />
Besides the "traditional" methods of treatment<br />
• grinding (grinder)<br />
• cutting (angle grinder, floor saw)<br />
• chiselling (chisel)<br />
• hammering (chisel scaler, needle gun)<br />
• brushing (brush, rotary brushes, brush machine)<br />
• planing (planer)<br />
• sweeping (broom, magnetic broom, sweeping machine)<br />
• blowing off (hot/warm air)<br />
• vacuuming (industrial vacuum cleaner)<br />
the following cleaning and blasting equipment<br />
• water-jet cleaner up to 5 N/cm 2 (0.5 bar)<br />
• steam cleaner up to 5 N/cm 2 (0.5 bar)<br />
• high-pressure water-jet cleaner up to 4000 N/cm 2 (400 bar)<br />
• wet-blasting equipment with blasting medium recovery<br />
• mist abrasive sandblasting equipment<br />
• wet abrasive sandblasting equipment<br />
• dry-blasting equipment with blasting medium recovery<br />
• free-jet pressure equipment<br />
• flame cleaning to DVS 0302<br />
• liquid nitrogen cleaning<br />
• infrared cleaning<br />
are also described in publications (ZTV-SIB / DAfStb).<br />
Cleaning methods using solvents are also still in use, particularly in the case of greasy or<br />
atmospheric pollution and/or flexible synthetic sheeting.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004
Preparing the substrate<br />
1. Flatness of substrate<br />
The flatness of the substrate is based on DIN 18202 "Dimensional tolerances in building<br />
construction". Unevenness and irregularities cannot be compensated for by the <strong>KEMPER</strong>OL ®<br />
primer to be applied and therefore require special treatment. High spots must be removed<br />
and low spots filled with <strong>KEMPER</strong> <strong>SYSTEM</strong> trowel-applied levelling or repair Mortar.<br />
In this case the levelling mortar is used after applying the primer. The filling compound<br />
consists of a mixture of<br />
- <strong>KEMPER</strong>TEC ® EP-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 4 or<br />
- <strong>KEMPER</strong>TEC ® EP5-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 2.<br />
The repair mortar is likewise used after applying the primer. The mortar consists of a mixture<br />
of<br />
- <strong>KEMPER</strong>TEC ® EP-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 9 or<br />
- <strong>KEMPER</strong>TEC ® EP5-Primer and <strong>KEMPER</strong>TEC KR Quartz Sand Mixture in a ratio of 1 : 5.<br />
The repair mortar is used for unevenness in the range 6–20 mm.<br />
Repair mortar can also be used to make good smaller damaged sections or spalling, e.g. along<br />
edges of joints. Depending on the application and the local conditions, the quartz sand/binder<br />
mixing ratio may be varied in order to obtain an optimum result. For further details please<br />
refer to the technical data sheets for <strong>KEMPER</strong>TEC ® EP-Primer or <strong>KEMPER</strong>TEC ® EP5-Primer.<br />
Either mortar has to be scattered with <strong>KEMPER</strong>TEC NQ 0408.<br />
2. Soiling<br />
<strong>KEMPER</strong>TEC ® primers do not adhere well, if at all, to soiled substrates. Therefore, the surfaces<br />
must be thoroughly cleaned wet or dry depending on the type of soiling with, for example,<br />
an industrial vacuum cleaner, high-pressure water jets, <strong>KEMPER</strong>TEC ® MEK Cleaning Agent<br />
when using steam cleaners, scouring machines and flame cleaners. Any bitumen or products<br />
containing creosote adhering to the substrate must be removed completely by planning or<br />
blast-cleaning.<br />
3. Porous and loose constituents<br />
Cement laitance, cement flakes, mortar residue and all surface constituents, e.g. old paint,<br />
that are not permanently attached to the substrate must be removed by chiselling, planing,<br />
blast-cleaning or grinding prior to applying the primer and can be levelled as described under<br />
point 1 above.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004
4. Cracks in the substrate<br />
On substrates with a cement binder a network of surface cracks does not have any<br />
detrimental effect on <strong>KEMPER</strong> <strong>SYSTEM</strong> waterproofing systems; however, greater consumption<br />
of primer must be allowed for because the substrate must be fully saturated. Continuous<br />
shrinkage cracks can be filled with <strong>KEMPER</strong>TEC ® Filling Compound after applying the primer.<br />
Settlement cracks and other cracks due to structural movement can be filled with <strong>KEMPER</strong>OL ®<br />
Repair Mortar and are bridged over reliably by applying, for example, a double layer of<br />
waterproofing at this point.<br />
5. Joints<br />
Joints in the substrate should be straight, with a consistent width and stable edges. Any<br />
damage can be made good with <strong>KEMPER</strong>TEC ® Repair Mortar.<br />
6. Voids<br />
In the case of voids, e.g. under old ceramic tile finishes, the tiles must be removed and the<br />
void must be made good with a similar material. <strong>KEMPER</strong>TEC ® Repair Mortar can also be used<br />
to level such unevenness.<br />
Relevant data sheets and standards:<br />
• DIN 18299 – General technical specifications for building works; general rules for all<br />
kinds of building works<br />
• DIN 18336 – General technical specifications for building works; <strong>Waterproofing</strong> works<br />
• DIN 18352 – General technical specifications for building works; Tile laying works<br />
• DIN 18353 – General technical specifications for building works; Floor screed works<br />
• DIN 18365 – General technical specifications for building works; Flooring works<br />
• DIN 18202 – Dimensional tolerances in building construction – buildings<br />
• DIN 18195 – <strong>Waterproofing</strong> of buildings and structures<br />
• <strong>KEMPER</strong> <strong>SYSTEM</strong> technical data sheets<br />
• <strong>KEMPER</strong> <strong>SYSTEM</strong> processing guidelines<br />
Note: This edition supersedes all previous editions of Technical Information 21.<br />
Vellmar, August 2009<br />
The technical information and application instructions contained herein reflect the current level of knowledge and experience with<br />
our products. In each case, the new edition supersedes the previous technical information and renders it invalid. It is therefore<br />
necessary that you always have to hand the current code of practice. When using our products, a detailed, object-related and<br />
qualified inspection is required in each individual case in order to determine whether the product and / or application technology in<br />
question meets the specific requirements and purposes. We are liable only for our products being free from faults – correct<br />
application of our products therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively<br />
on the basis of our conditions of sale and delivery.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001:2004
Technical Information 24<br />
Cleaning and care of <strong>KEMPER</strong>OL ® waterproofings and <strong>KEMPER</strong>DUR ® coatings<br />
Please follow the advice given below regarding the cleaning and care of surface coatings<br />
and waterproofing systems supplied by <strong>KEMPER</strong> <strong>SYSTEM</strong>.<br />
� <strong>KEMPER</strong>OL ® waterproofing systems and coatings may be cleaned with conventional<br />
floor cleaning and care products. In all cases, follow the instructions of the<br />
manufacturer exactly regarding the use of such products.<br />
� Highly concentrated cleaning agents, disinfectants and caustic sanitary cleaners are<br />
unsuitable because they can lead to etching of <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ®<br />
surfaces.<br />
� Some window cleaning agents contain solvents which can attack the surfaces or<br />
cause discoloration. Therefore, avoid excessive splashing when cleaning windows<br />
with such products and always remove all traces of such cleaning agents from the<br />
waterproofing or coating.<br />
� Do not clean <strong>KEMPER</strong>OL ® or <strong>KEMPER</strong>DUR ® surfaces with metal brushes, scrapers or<br />
other mechanical means. High-pressure cleaning equipment or cleaning machines<br />
should be used only occasionally. The maximum pressure that may be used on<br />
<strong>KEMPER</strong>OL ® waterproofing systems is 80 bar and on <strong>KEMPER</strong>DUR ® coatings 40 bar.<br />
Pressures in excess of these may damage the surfaces. Furthermore, always maintain<br />
a distance of at least 20 cm between the nozzle and the surface.<br />
� Reposition plant tubs, flowerpots, etc. at regular intervals in order to prevent<br />
marking and discolouring the surfaces underneath. Special products for removing<br />
algae may be used as required to clean any surfaces affected by algae growths.<br />
Note: This edition supersedes all previous editions of this Technical Information.<br />
Vellmar, June 2008<br />
The technical information and application instructions contained herein reflect the current level of knowledge<br />
and experience with our products. In each case, the new edition supersedes the previous technical information<br />
and renders it invalid. It is therefore necessary that you always have to hand the current code of practice. When<br />
using our products, a detailed, object-related and qualified inspection is required in each individual case in order<br />
to determine whether the product and / or application technology in question meets the specific requirements<br />
and purposes. We are liable only for our products being free from faults – correct application of our products<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
therefore falls entirely within your scope of liability and responsibility. Our products are sold exclusively on the<br />
basis of our conditions of sale and delivery.<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · 34246 Vellmar · Germany · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Calculation<br />
Recommendations<br />
Survey table over<br />
estimated quantities and time<br />
for the application of<br />
<strong>KEMPER</strong>OL und <strong>KEMPER</strong>DUR<br />
products<br />
Published 06/2008<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Product Estimated use Estimated time<br />
<strong>KEMPER</strong>TEC Primers<br />
<strong>KEMPER</strong>TEC D-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />
<strong>KEMPER</strong>TEC R-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />
<strong>KEMPER</strong>TEC <strong>1K</strong>-Primer approx. 0,3 kg / m² approx. 3 min / m²<br />
<strong>KEMPER</strong>TEC AC Primer approx. 0,5 kg / m² approx. 5 min / m²<br />
<strong>KEMPER</strong>TEC EP-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />
<strong>KEMPER</strong>TEC EP5-Primer approx. 0,5 kg / m² approx. 5 min / m²<br />
<strong>KEMPER</strong>TEC FPO-Primer approx. 0,05 kg / m² approx. 3 min / m²<br />
Bonding coat<br />
<strong>KEMPER</strong>TEC EP-Primer with<br />
<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />
<strong>KEMPER</strong>TEC EP5-Primer with<br />
<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />
Levelling Mortar<br />
<strong>KEMPER</strong>TEC EP-Primer<br />
<strong>KEMPER</strong>TEC KR Quartz Sand Mixture<br />
(Mixture ratio 1 : 4)<br />
<strong>KEMPER</strong>TEC EP5-Primer<br />
<strong>KEMPER</strong>TEC KR Quartz Sand Mixture<br />
(Mixture ratio 1 : 2)<br />
Repair Mortar<br />
<strong>KEMPER</strong>TEC EP-Primer<br />
<strong>KEMPER</strong>TEC KR Quartz Sand mixture<br />
(Mixture ratio 1 : 9)<br />
<strong>KEMPER</strong>TEC EP5-Primer<br />
<strong>KEMPER</strong>TEC KR Quartz Sand mixture<br />
(Mixture ratio 1 : 5)<br />
Alkali Protection Layer<br />
<strong>KEMPER</strong>TEC EP-Primer with<br />
<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />
<strong>KEMPER</strong>TEC EP5-Primer with<br />
<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />
<strong>KEMPER</strong>TEC AC-Primer with<br />
<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />
<strong>KEMPER</strong>OL <strong>Waterproofing</strong><br />
<strong>KEMPER</strong>OL V 210 <strong>Waterproofing</strong> mit<br />
<strong>KEMPER</strong>OL Fleece 165<br />
<strong>KEMPER</strong>OL V 210 <strong>Waterproofing</strong> with<br />
<strong>KEMPER</strong>OL Fleece 200<br />
<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> with<br />
<strong>KEMPER</strong>OL 120 Fleece<br />
<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> with<br />
<strong>KEMPER</strong>OL Fleece 200<br />
<strong>KEMPER</strong>OL 2K-<strong>PUR</strong> <strong>Waterproofing</strong> with<br />
<strong>KEMPER</strong>OL Fleece 165<br />
approx. 0,3 kg / m²<br />
approx. 1,0 kg / m²<br />
approx. 0,3 kg / m²<br />
approx. 1,0 kg / m²<br />
approx. 1,5 kg/m²/mm.<br />
approx. 1,5 kg/m²/mm.<br />
approx. 1,5 kg/m²/mm.<br />
approx. 1,5 kg/m²/mm.<br />
approx. 0,6 kg / m²<br />
approx. 1,0 kg / m²<br />
approx. 0,6 kg / m²<br />
approx. 1,0 kg / m²<br />
approx. 0,5 kg / m²<br />
approx. 1,0 kg / m²<br />
approx. 2,8 kg / m²<br />
approx. 1,05 m² / m²<br />
approx. 3,6 kg / m²<br />
approx. 1,05 m² / m²<br />
approx. 3,6 kg / m²<br />
approx. 1,05 m² / m²<br />
approx. 4,0 kg / m²<br />
approx. 1,05 m² / m²<br />
approx. 3,6 kg / m²<br />
approx. 1,05 m² / m²<br />
approx. 5 min / m²<br />
approx. 1 min / m²<br />
approx. 5 min / m²<br />
approx. 1 min / m²<br />
approx. 7 min / m².<br />
approx. 7 min / m².<br />
approx. 7 min / m².<br />
approx. 7 min / m²<br />
approx. 6 min / m²<br />
approx. 1 min / m²<br />
approx. 6 min / m²<br />
approx. 1 min / m²<br />
approx. 6 min / m²<br />
approx. 1 min / m²<br />
approx. 15 min / m²<br />
approx. 15 min / m²<br />
approx. 12 min / m²<br />
approx. 12 min / m²<br />
approx. 15 min / m²
Product Estimated use Estimated time<br />
<strong>KEMPER</strong>OL AC <strong>Waterproofing</strong> with<br />
<strong>KEMPER</strong>OL Fleece 165<br />
<strong>KEMPER</strong>OL Fleece<br />
approx. 2,5 kg / m²<br />
approx. 1,05 m² / m²<br />
for overlapping application<br />
<strong>KEMPER</strong>OL Fleece (120, 165, 200) approx. 1,05 m² / m²<br />
for edge to edge (butt-jointed) application<br />
<strong>KEMPER</strong>OL Fleece (120, 165, 200)<br />
<strong>KEMPER</strong>OL Reinforcement Strip<br />
approx. 1,0 m² / m²<br />
approx. 1 lfm / joint<br />
<strong>KEMPER</strong>OL TP Talcum Powder (<strong>KEMPER</strong>OL V 210)<br />
approx. 10 min / m²<br />
refer to<br />
waterproofing<br />
refer to<br />
waterproofing<br />
<strong>KEMPER</strong>OL TP Talcum Powder approx. 0,1 kg / m² approx. 3 min / m²<br />
<strong>KEMPER</strong>OL AC as Coating<br />
<strong>KEMPER</strong>OL AC <strong>Waterproofing</strong> with<br />
<strong>KEMPER</strong>DUR AC Filler<br />
<strong>KEMPER</strong>DUR AC Finish with *<br />
<strong>KEMPER</strong>DUR CS Microchips<br />
<strong>KEMPER</strong>DUR HB High-Build<br />
On horizontal surfaces<br />
<strong>KEMPER</strong>DUR HB High-Build and<br />
<strong>KEMPER</strong>DUR CL Chips<br />
approx. 1,5 kg / m²<br />
approx. 3,7 kg / m²<br />
approx. 0,6 kg / m²<br />
approx. 0,1 kg / m²<br />
approx. 5,0 kg / m²<br />
approx. 0,03 kg / m²<br />
approx. 12 min / m²<br />
approx. 3 min / m²<br />
approx. 2 min / m²<br />
approx. 15 min / m²<br />
approx. 2 min / m²<br />
On vertical surfaces<br />
<strong>KEMPER</strong>DUR Deko 2K * approx. 0,4 kg / m² approx. 8 min / m²<br />
<strong>KEMPER</strong>DUR Finish*<br />
<strong>KEMPER</strong>DUR Finish gloss approx. 0,25 kg / m² approx. 5 min / m²<br />
<strong>KEMPER</strong>DUR TC<br />
<strong>KEMPER</strong>DUR TC and<br />
<strong>KEMPER</strong>DUR CQ 0408 Color Quartz<br />
<strong>KEMPER</strong>DUR TC and<br />
<strong>KEMPER</strong>DUR GR 0510 Granit<br />
<strong>KEMPER</strong>DUR TC and<br />
<strong>KEMPER</strong>TEC NQ 0712 Natural Quartz<br />
<strong>KEMPER</strong>DUR ECO-Finish *<br />
approx. 4,0 kg / m²<br />
approx. 4,0 kg / m²<br />
approx. 4,0 kg / m²<br />
approx. 6,0 kg / m²<br />
approx. 4,0 kg / m²<br />
approx. 5,0 kg / m²<br />
approx. 8 min / m²<br />
approx. 5 min / m²<br />
approx. 8 min / m²<br />
approx. 5 min / m²<br />
approx. 8 min / m²<br />
approx. 5 min / m²<br />
<strong>KEMPER</strong>DUR ECO-Finish ca. 0,2 kg / m² ca. 5 min / m²<br />
<strong>KEMPER</strong>DUR Sand Coating / <strong>KEMPER</strong>DUR Decor Stone<br />
refer to Adhesive Bridge<br />
<strong>KEMPER</strong>DUR QB1 Sand Coating Adhesive<br />
<strong>KEMPER</strong>DUR CQ 2035 Colour Quartz<br />
(Mixture 1,7 kg Adhesive with 25 kg Colour Quartz)<br />
<strong>KEMPER</strong>DUR QB1 Sand Coating Adhesive<br />
<strong>KEMPER</strong>DUR DS 2040 Decor Stone<br />
(Mixture 1,7 kg Adhesive with 25 kg Decor Stone)<br />
<strong>KEMPER</strong>DUR Quartz Coating<br />
<strong>KEMPER</strong>DUR Deko transparent<br />
<strong>KEMPER</strong>DUR CQ 0408 Colour Quartz<br />
approx. 18 kg / m².<br />
ca. 18 kg / m².<br />
approx. 0,3 kg / m²<br />
approx. 4,0 kg / m²<br />
approx. 20 min / m².<br />
ca. 20 min / m².<br />
approx. 4 min / m²<br />
approx. 3 min / m²
Product Estimated use Estimated time<br />
<strong>KEMPER</strong>DUR Deko transparent as Sealant<br />
(incl. sweeping away the excess of Colour Quartz)<br />
<strong>KEMPER</strong>DUR Deko *<br />
<strong>KEMPER</strong>DUR Deko<br />
<strong>KEMPER</strong>DUR CL Chips<br />
approx. 0,4 kg / m² approx. 10 min / m²<br />
approx. 1,0 kg / m²<br />
approx. 0,03 kg / m²<br />
approx. 6 min / m²<br />
approx. 2 min / m²<br />
<strong>KEMPER</strong>DUR Finish silk approx. 0,15 kg / m² approx. 3 min / m²<br />
<strong>KEMPER</strong>DUR Deko 2K *<br />
<strong>KEMPER</strong>DUR Deko 2K and<br />
<strong>KEMPER</strong>DUR Chips<br />
<strong>KEMPER</strong>DUR EP-Finish *<br />
approx. 1,0 kg / m²<br />
approx. 0,03 kg / m²<br />
approx. 8 min / m²<br />
approx. 2 min / m²<br />
<strong>KEMPER</strong>DUR EP-Finish farbig approx. 0,6 kg / m² approx. 5 min / m²<br />
This table represents a guide for the user and should be regarded only as a recommendation.<br />
For the choice of primers, waterproofing systems and coating systems, please refer to the technical data sheet of each product and the respective<br />
priming recommendation, since it is not possible, to combine all primers with all waterproofing or coating systems!<br />
Depending on the kind of detail, material consumption may increase by 20%.<br />
For special details or flashings, such as flat roof drains, ventilation pipes, doomed rooflights, etc. material consumption may increase by 100%. For<br />
small areas (up to 50 m²) add 2 min. mixing time.<br />
When calculating the consumption of fleece, consider 5 cm overlap.
Chemical resistance<br />
from A to Z<br />
Survey table for chemical resistance of<br />
unsattured Polyesters (UP)<br />
<strong>KEMPER</strong>OL V 210 <strong>Waterproofing</strong><br />
<strong>KEMPER</strong>OL BR <strong>Waterproofing</strong><br />
one-component polyurethanes (<strong>1K</strong>-PU)<br />
<strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong><br />
<strong>KEMPER</strong>DUR Deko<br />
two-component polyurethanes (2K-PU)<br />
<strong>KEMPER</strong>OL 2K-<strong>PUR</strong> <strong>Waterproofing</strong><br />
<strong>KEMPER</strong>DUR Deko 2K<br />
<strong>KEMPER</strong>DUR HB High Build<br />
<strong>KEMPER</strong>DUR FC Floor Coating<br />
polymethyl methacrylates (PMMA)<br />
<strong>KEMPER</strong>OL AC <strong>Waterproofing</strong><br />
<strong>KEMPER</strong>DUR AC Finish<br />
epoxy resins (EP)<br />
<strong>KEMPER</strong>TEC EP-/ EP5-Primer<br />
<strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510<br />
www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001<br />
06/2008
Substance<br />
solid<br />
Solution<br />
liquid<br />
UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />
A Accumulator Acid<br />
x o o o + +<br />
Acetic Acid < 10 % x o o o + +<br />
Acetic Acid conc. x - - - - -<br />
Acetone x - - - - -<br />
Aluminumchloride Solution 30% x + + + + +<br />
Ammonia x - - - + +<br />
Ammonium Carbonate x x + + + + +<br />
Ammonium Chloride x x + + + + +<br />
Ammonium Perchlorate x x o o o + +<br />
Ammonium Phosphate x x + + + + +<br />
Ammonium Sulphate x x + + + + +<br />
Aqua Regia x - - - - -<br />
B Barium Chloride<br />
x x + + + + +<br />
Barium Hydroxide x o o o + +<br />
Barium Hydroxide solution x - - - + +<br />
Barium Nitrate x x + + + + +<br />
Beer x + + + + +<br />
Bleach x - - - - o<br />
Borax x x + + + + +<br />
Boric Acid x + + + + +<br />
Butanal x - - - - -<br />
Butanol x o o o + +<br />
Butylacetate x - - - - +<br />
Butyric Acid x - - - + o<br />
C Calcium Chloride<br />
x x + + + + +<br />
Calcium Formiate x x + + + + +<br />
Calcium Hydroxide x + + + + +<br />
Calcium Hydroxide moist x - - - + +<br />
Calcium Hydroxide Solution x - - - + +<br />
Calcium Nitrate x x + + + + +<br />
Carbon Tetra Chloride x - - - - -<br />
Castor Oil x o o o o +<br />
Caustic potash solution 10 % (lye) x - - - + +<br />
Caustic potash solution 10-50 % (lye) x - - - o +<br />
Caustic potash solution conc. (lye) x - - - - +<br />
+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />
o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />
(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />
- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />
Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures
Substance<br />
solid<br />
Solution<br />
liquid<br />
UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />
Caustic Soda 10 % (lye) x - - - + +<br />
Caustic Soda 10-50 % (lye) x - - - o +<br />
Caustic Soda conc. (lye) x - - - - +<br />
Chloracetic Acid x x - - - - -<br />
Chlorinated Water x o o o o o<br />
Chlorinated Water (Swimming pools) x + + + + +<br />
Chloroform x - - - - +<br />
Chromic Acid 10% x - - - - -<br />
Citric Acid x x o o o + +<br />
Cobalt Chloride x x + + + + +<br />
Cobalt Nitrate x x + + + + +<br />
Copper Chloride x x + + + + +<br />
Copper Sulphate x x + + + + +<br />
Cyclohexanol x o o o + +<br />
Cyclohexanon x o o o - o<br />
D Dibutyl Phthalate<br />
x o o o o +<br />
Dioctyl Phthalate x o o o o +<br />
E Ethanol < 50 %<br />
x o o o + o<br />
Ethanol conc. x - - - + o<br />
Ether x o o - - -<br />
Ethylacetate (Aceticacidethylester) x - - - - o<br />
Ethylglycol Acetat x - - - - o<br />
F Ferrum Chloride<br />
x x + + + + +<br />
Ferrum Chloride Solution 50% x + + + + +<br />
Ferrum Sulphate x + + + + +<br />
Ferrum Sulphate x x + + + + +<br />
Fertilizer x x o o o o o<br />
Formaldehyde 30-40% (Formalin) x o o o - +<br />
Formic Acid < 30 % x o o o o o<br />
Formic Acid 31-85 % x - - - - -<br />
Fuel Oil EL x + + + + +<br />
Fuel, Petrol x o o o o +<br />
G Glucose<br />
x x + + + + +<br />
Glycerin x + + + + +<br />
Glycol x o o o + o<br />
+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />
o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />
(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />
- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />
Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures
Substance<br />
solid<br />
Solution<br />
liquid<br />
UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />
H Hydrobromic Acid<br />
x o o o + o<br />
Hydrochloric Acid 20 % x - - - o +<br />
Hydrochloric Acid conc. x - - - o o<br />
Hydrofluoric Acid x - - - - -<br />
I Isopropyl Alcohol<br />
x o o o + o<br />
L Lactic Acid 10%<br />
x + + + + +<br />
Lactic Acid conc. x o o o o +<br />
Lead Acetate x x + + + + +<br />
Lime Chloride x o o o o o<br />
Lubricating Grease x + + + + +<br />
Lubricating Oil x + o + + +<br />
M Magnesium Chloride<br />
x x + + + + +<br />
Magnesium Nitrat x x + + + + +<br />
Magnesium Sulphate x x + + + + +<br />
Maleic Acid x x + + + + +<br />
Manganese Sulphate x x + + + + +<br />
Margarine x x + + + + +<br />
Mercury x + + + + +<br />
Mercury Chloride x x + + + + +<br />
Methanol x - - - + -<br />
Methyl Acetate x - - - - -<br />
Methyl Chloride x - - - - -<br />
Methylamine x - - - - -<br />
Methylethylketone x - - - - -<br />
Methylisobutylketone x - - - - -<br />
Milk x + + + + +<br />
Mineral Oil x + + + + +<br />
Molasses (Beet) x + + + + +<br />
N Nickel Chloride<br />
x x + + + + +<br />
Nickel Sulphate x x + + + + +<br />
O Nitric Acid (Azotic Acid)<br />
x - - - - o<br />
Oil for cooking x + + + + +<br />
Oil for Engines x + + + + +<br />
Oil from Flax (Linen) x + + + + +<br />
Oxalic Acid x x x o o o o +<br />
+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />
o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />
(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />
- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />
Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures
Substance<br />
solid<br />
Solution<br />
liquid<br />
UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />
Ozone + + + + +<br />
P Paraffin<br />
x + + + + +<br />
Perchloric Acid < 10 % x o o o + o<br />
Perchloric Acid 70 % x - - - - +<br />
Petroleum x o o o o +<br />
Phenol x x - - - - -<br />
Phosphoric Acid 10 % x o o o + +<br />
Phosphoric Acid 50 % x - - - o o<br />
Phosphoric Acid conc. x - - - - -<br />
Phthalic Acid x + + + + +<br />
Potassium Bromate x x o o o + +<br />
Potassium Carbonate x x + + + + +<br />
Potassium Chlorate x x o o o + +<br />
Potassium Chloride x x + + + + +<br />
Potassium Chromat x x o o o + +<br />
Potassium Cyanide x x + + + + +<br />
Potassium Dichromat x x o o o + +<br />
Potassium Fluoride x x + + + + +<br />
Potassium Iodid x x + + + + +<br />
Potassium Nitrat x x + + + + +<br />
Potassium Permangante x x o o o + +<br />
Potassium Phosphate x x + + + + +<br />
Potassium Sulphate x x + + + + +<br />
Propanol x o o o + o<br />
Propionic Acid 10 % x o o o + o<br />
Propionic Acid conc. x - - - o -<br />
S Salicylic Acid<br />
x x o o + + +<br />
Salt x x + + + + +<br />
Salt moist x + + + + +<br />
Silver Nitrate x x + + + + +<br />
Sodium Acetat x x + + + + +<br />
Sodium Bromat x x o o o o o<br />
Sodium Bromid x x + + + + +<br />
Sodium Carbonat x x + + + + +<br />
Sodium Chlorat x x o o o o o<br />
+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />
o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />
(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />
- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />
Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures
Substance<br />
solid<br />
Solution<br />
liquid<br />
UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />
Sodium Chlorid x x + + + + +<br />
Sodium Cyanide x x + + + + +<br />
Sodium Fluoride x x + + + + +<br />
Sodium Hypochlorite x x + + + + +<br />
Sodium HypoChlorite Solution x o o o o o<br />
Sodium Nitrate x x + + + + +<br />
Sodium Perborate x x o o o o o<br />
Sodium Perchlorat x x o o o o o<br />
Sodium Peroxide x x - - - - -<br />
Sodium Phosphate x x + + + + +<br />
Sodium Sulfite x x + + + + +<br />
Sodium Sulphate x x + + + + +<br />
Sodium-Potassium Silicate x o o o o +<br />
Stearic Acid x x + + + + +<br />
Styrene x - - - - o<br />
Succinic Acid x x + + + + +<br />
Sugar x x + + + + +<br />
Sugar moist x + + + + +<br />
Sulfuric Acid 10 % x + + + + +<br />
Sulfuric Acid 20 % x + + + + +<br />
Sulfuric Acid 40 % x o o o + o<br />
Sulfuric Acid 60 % x - - - + o<br />
Sulfuric Acid conc. x - - - - -<br />
Sulfuric Acid conc. x - - - - -<br />
T Table Salt<br />
x x + + + + +<br />
Table Salt Solution x + + + + +<br />
Tannic Acid x + + + + +<br />
Tartaric Acid x x + + + + +<br />
Tetra Hydro Furane (THF) x - - - - -<br />
Tin Chloride x x + + + + +<br />
Toluene x - - - - -<br />
Tri Sodium Phosphate x x o o o o o<br />
Trichlorethan x - - - - -<br />
Trichlorethylene x - - - - -<br />
Triethanolamine x - - - - -<br />
+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />
o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />
(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />
- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />
Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures
Substance<br />
solid<br />
Solution<br />
liquid<br />
UP <strong>1K</strong>-PU 2K-PU PMMA EP<br />
Triethylamine x - - - - -<br />
Turpentine x o o o o o<br />
U Urea<br />
x x + + + + +<br />
Urine x o o o + +<br />
W Washing Powder 5%<br />
x + + + + +<br />
Wasser (destillated) x + + + + +<br />
Water (Sea-, Mineral-, Potable) x + + + + +<br />
Wine x + + + + +<br />
X Xylol<br />
x - - - - o<br />
Z Zinc Chloride<br />
x x + + + + +<br />
Zinc Nitrate x x + + + + +<br />
Zinc Sulphate x x + + + + +<br />
+ resistant - no alteration of the <strong>KEMPER</strong>OL System after 60 days exposure at 68°F (20°C) to the listed material<br />
o resistant with restrictions - no alteration of the <strong>KEMPER</strong>OL System after 3 days exposure at 68°F (20°C) to the listed material<br />
(i.e. <strong>Waterproofing</strong> system is stable when only small amounts are present and are removed immediately)<br />
- not resistant - severe alteration of the <strong>KEMPER</strong>OL System when exposed to the listed material<br />
Note: Specific testing is required for unlisted chemicals, mixtures, concentrations and temperatures