______________________________________________________________________________________________________________ <strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510 www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001
Priming Recommendation <strong>KEMPER</strong>OL <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> Published 06/2009 applicable = � This table represents a guide for the user and should be regarded only as a recommendation. Depending on the building, it may be necessary to carry out suitability tests (individual testing), because the overall structure must always be considered. All substrates must be evenly solid and free of separating substances (oil, seperating agents, free granules - see also TI 21). Other substrates not listed here must always be checked with regard to their adhesion performance. Substrate <strong>KEMPER</strong>TEC EP- / EP5- Primer <strong>KEMPER</strong>TEC D- / R- Primer Bitumen roof sheet (V 13, V 60, G 200, PYE (SBS)) � � <strong>KEMPER</strong>TEC FPO-Primer <strong>KEMPER</strong>TEC <strong>1K</strong>-Primer 4 4,8 � APP-Bitumen roof sheet, granulated Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing Asphalt, weathered � 4 � 4 Plastic sheets (EPDM, ECB, PVC-P, PE, PP, PIB, EVA) Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing FPO- or TPO-Plastic sheets � Fibre-cement sheets � � Clinker, Bricks, visible brickwork stones (grinded) � � Concrete, screed Plastic-modified screed and mortar (PCC) Stones for construction (lightweight, gas or pumice concrete, cement and calcareous sandstone) � Glass (uncoated) - MEK cleaned Zinc, galvanised steel Copper, lead Steel, special steels (V2A, V4A), Aluminium Insulating materials (polystyrene, rock wool) Insulating materials (polyurethane) Wood panels, plywood, chipboard, OSB 4 4,8 � 4 4,8 � � 4,8 � � � Indiv. Testing Indiv. Testing Indiv. Testing Indiv. Testing 2,3,4 � � � 2 � 2 2,3,4 � 2 2,3,4 � 2,3 2,3,4 2,3,4 � � � � � 4,6 4,6 4,6 � � 4,6 4,6 4,6 � � 4,6 � �4,6 2 Mechanical pre-treatment and cleaning with <strong>KEMPER</strong>TEC® MEK Cleaning Agent necessary. 3 Low adhesion – additional mechanical fastening is recommended. 4 Areas with a minimum overlap larger than 15 cm necessary. 6 Partition layer required! 8 Consider Technical Data Sheet <strong>KEMPER</strong>TEC® <strong>1K</strong>-Primer When using this priming table, it is necessary to follow <strong>KEMPER</strong> <strong>SYSTEM</strong> preparation guidelines and technical advice. Please observe our warranty clause for application-related consultation. <strong>KEMPER</strong> <strong>SYSTEM</strong> GmbH & Co. KG · Holländische Straße 32-36 · D-34246 Vellmar · Tel. +49-(0)561-82950 · Fax +49-(0)561-829510 www.kemper-system.com · post@kemper-system.com · Certified according to DIN EN ISO 9001:2000 and DIN EN ISO 14001