KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM
KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM
KEMPEROL® 1K-PUR Waterproofing - KEMPER SYSTEM
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>KEMPER</strong>TEC ® FPO-<br />
Primer<br />
Uses<br />
� For excellent adhesion between polyolefin plastics<br />
(FPO/TPO) and following <strong>KEMPER</strong>OL ® products<br />
- <strong>KEMPER</strong>OL ® <strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong> System<br />
- <strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong> <strong>Waterproofing</strong> System<br />
� For new construction and remedial projects<br />
Features<br />
� Quickly drying<br />
� Excellent adhesion on FPO sheets<br />
Composition<br />
Bonding agent dissolved in toluene.<br />
Pack sizes<br />
500 g, 1 kg und 3 kg units.<br />
Shelf Life<br />
Can be stored unopened for up to 6 months in a cool,<br />
dry, frost-free place.<br />
Properties<br />
Form liquid<br />
Colour transparent<br />
Workability period* [min] approx. 5<br />
Rainproof* after [min] approx. 30<br />
Can be walked on* after [min] approx. 30<br />
Next coat can be applied after*<br />
[min]<br />
approx. 30<br />
* Values obtained at a temperature of 23 °C - 50 % rel. humidity. May vary<br />
according to weather conditions such as wind, humidity and temperature.<br />
Usage guide<br />
Depending on the nature of the substrate: approx. 50<br />
g/m².<br />
Application<br />
The substrate must be dry, sound and free from any<br />
material that would hinder adhesion and must be<br />
prepared according to Technical Information TI 21 -<br />
Substrate Preparation.<br />
Clean surface with <strong>KEMPER</strong>TEC ® MEK Cleaning<br />
Agent.<br />
Warning: <strong>KEMPER</strong>TEC ® FPO-Primer is not<br />
appropriate for every substrate!<br />
This primer is especially developed for polyolefin<br />
plastics!<br />
Apply only when substrate and ambient temperatures<br />
exceed 5 °C and are declining. During application the<br />
surface temperature must be 3 °C above the dew<br />
point. If the substrate temperature is below or at the<br />
dew point temperature then moisture can form at the<br />
surface which can affect coating adhesion and cure.<br />
(Please refer to DIN 4108 - 5 Tab.1 for a dew point<br />
graph).<br />
Prime in one operation until the pores are closed.<br />
Distribute with a perlon roller so that material<br />
accumulation is avoided.<br />
Provided that the primer is dry and tack-free,<br />
additional suitable <strong>KEMPER</strong> <strong>SYSTEM</strong> waterproofing<br />
products (<strong>KEMPER</strong>OL ® 2K-<strong>PUR</strong> and <strong>KEMPER</strong>OL ®<br />
<strong>1K</strong>-<strong>PUR</strong> <strong>Waterproofing</strong>) should be applied after 15 -<br />
30 minutes - depending on the weather conditions,<br />
wind humidity and temperature. The <strong>KEMPER</strong>OL ®<br />
membrane has to be applied within the next 24 hours<br />
or separating effects can occur.