Periodically check the condition of the filter. Correctfilter maintenance prolongs the life of the aerosol.The frequency with which filter should be replaceddepends on the conditions in which the unit is used.However, it is recommended that filters be replacedafter 20 working hours or in the event they are visiblydirty. The filter is located on the lower part of theaerosol unit. To replace the filter:Open the filter cover cap, using a small pointed objectif necessary· Remove the filter to be replaced from its housing;use a sharp-pointed object for assistance if necessary;· Carefully insert the new filter;· Return the filter cover cap to its original positionTECHNICAL SPECIFICATIONSNominal voltage: 230 VFrequency: 50 HzPower: 130 VAFuse: T 1.6 AL 250V ~Maximum flow: 15 ± 2 l/min.Operational flow: 7 ± 1 l/min.Max pressure: 2 +- 0.4 atmOperating pressure: 0,6 ± 0,1 atmProtection against liquids: IPX0Weight: 1210 gDevice conditions of use: 20’ ON - 40’ OFFMMAD: 3,2 ± 0,2 μmBreathable fraction: 72,2 % ± 2%Phial capacity: 5 mlNoise level at 50cm*: 63 dB(A)nebulisation speed: 0,25 ± 0,04 ml/min.residual volume not nebulised: 0,8 ± 0,05 g% < 5µm: 72,2% ± 2%% between 2 and 5 microns 51,4%*The data relative to noise were measured with a newunit. Values may vary with use.If the product is used and maintained in accordancewith the instructions for use, it should have a lifeexpectancy of at least 1000 operating cycles. In theevent of breakage or damage, dispose of according toinstructions.The information on the unit’s capabilities providedby the manufacturer in accordance with EN 13544-1 may not apply to suspended or viscous medicines.EN 60601-1 Electrical-medical devices -Part 1: generalsafety standardsEN 60601-1-2 Medical electrical equipment - Part1-2: General requirements for basic safety and essentialperformance - Collateral standard: Electromagneticcompatibility - Requirements and testsEN 13544-1 Respiratory therapy units - Part 1: nebulisationsystems and related components12SYMBOLS KEY0068WARNING!Consult the Instructions for UseType BF applied partDouble insulationCompliant with MDD Directive 93/42 EEC+ 2007/47/ECAlternate currentStorage and transport conditionsAEROSOLS AEROSOLSHumidity: 15%/85%. Store in a cool, dryplaceTemperature: -10°C/+55°CEnvironmental Conditions of Use:AEROSOLS AEROSOLSHumidity: 15%/85%Store in a cool, dry placeTemperature: 10°C/40°CThe medical device requires special precautions regardingEMC and must be installed and used accordingto the information provided in the accompanyingdocuments.WARRANTY<strong>Chicco</strong> is covered by a guarantee should faulty materialsor manufacturing defects be discovered. Theguarantee period is 2 years. Any faulty parts shallbe replaced free of cost only if the unit has not beentampered with and all directions of use attached tothe unit have been strictly followed. Any tamperingwith unit/repairs carried out by personnel not authorisedby Artsana SpA result in the immediate voidingof all conditions of guarantee. In case of faulty orunsatisfactory operation, please contact the ArtsanaS.p.A dealer or distributor.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!