F.A.Q.DAMAGES LIKELY REASON SOLUTIONNO WORKING AT ALL + & - lines cut off or wrong connected Test wiringNo 24V tension between + & -Test tension in the Power Supply UnitReset failureDisconnected P.S.U hold 30S on & reconnect____________________________________________________________________________________________________NO CALL TONE IN THE FLATS BUT Monitors or phones no codified Codify installationCONFIRMATION CALL ON PANEL Lines & have been inverted Test wiringColumns connector wrong engagedTest connectors on encoder boardCp line wrong connectedConnect line Cp in the terminal C_____________________________________________________________________________________________________FEEDBACK Volume excessive on panel Volume potentiometers in speaker must beadjusted____________________________________________________________________________________________________THE WHOLE INSTALLATION BLOCKS Excessive power consumption Reinforce the main power adding extra P.S.UWHEN A CALL TO A HOUSING IS DONE Inappropriate wiring thicknessIncrease the wiring thicknessNo RG-59 coaxial cable is being used Replace by RG-59 or reinforce –Faulty Encoder BoardReplace Encoder Board____________________________________________________________________________________________________SOME MONITOR OR PHONE IS WELL Lines & have been inverted Test wiringPOWERED BUT DOES NOT WORK Monitors or Phones no codified Codify installationFaulty monitor bracketReplace monitor bracket____________________________________________________________________________________________________WHITE SCREEN ON MONITOR Faulty coaxial cable Test coaxial cableNo powered DVC-4S video signal distributor Power the DVC-4S video signal distributorFaulty DVC-4S video signal distributor Replace DVC-4S video signal distributorNo RG-59 coaxial cable is being used Replace by RG-59 or reinforce –No powered CCD cameraTest power on MV-DFaulty CCD cameraReplace MV-D____________________________________________________________________________________________________GREY PICTURE & NO CONTRAST Unadjusted monitor’s potentiometers Adjust monitor’s potentiometersIN THE MONITOR DVC-4S incorrectly configured Pull all the distributor’s jumper awayexcept the last one.Direct light on the cameraAvoid direct light on the cameraFaulty CCD cameraReplace MV-D module____________________________________________________________________________________________________ROLLING MONITOR PICTURE DVC-4S incorrectly configured Pull all the distributor’s jumper awayexcept the last one.No RG-59 coaxial cable is being used Replace by RG-59 or reinforce -____________________________________________________________________________________________________SELF-STARTING DOES NOT WORK No configured self-starting Configure self-starting either on encoderboard or monitorNo activated self-starting panelA first call to the monitor from the panelhas to be done for self-starting activation____________________________________________________________________________________________________CARDHOLDER LIGHTING DOES NOT Burnt out lamp Replace the lampLIGHT ON No power between R – C Test wiring and P.S.U.____________________________________________________________________________________________________ELECTRICAL STRIKE DOES NOT WORK Cut off R-C lines Test wiringFaulty Electrical StrikeReplace electrical strikeDIGITALTeclado Teclado F.A.Q. Video Video - Fonía F.A.Q63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!