4 – Charge: Name of analyzed charge. At that the charge could describe any other object such as for example
device, supplier, products line, monitoring name. The charge is necessary obligatory in case of using name’s
mode “Charge+Index” and “Charge+DateTime”. The charge could be used for documentation in table
heading, chart heading or in report heading.
5 – Operator Name: setting of operator name. It could be set manually. New recording is impossible before
analysis in case of quick start. The recording could be changed after analysis. It might be indicated in settings
of user control, if this information should be filled automatically at every analysis start.
6 – Sample created: Date and time of sample creation.
9.2.4 Actions
Job actions are related always to the actually selected job.
1 – New Sample: New sample will be prepared for analysis. It is possible only in that case when other sample
is not activated. Request appears after click, if it would be necessary to use available data. It relates first of all
to the sample name, charge and comment. These records will be deleted, if one answers “No” to the request.
Mode of sample name and user are saved.
Now new records could be done, for example a new charge should be analysed. These records will be saved
and will be valid from the beginning for the new sample also, if one answers “Yes” to the request. It is possible
to know about situation that a new sample was created by indication “Active” near button “New Sample”. Now
changes made in sample data will be related to the new sample. All changes in sample data will be in force for
the actual sample, if this mode is inactive at the present moment.
Request follows, if it is necessary to use this sample for a new analysis in special case when the last sample
does not contain any data. For new analysis will be used the last empty sample, if the answer to the request
will be “Yes”.
2 – Check + Create Sample: Input data and system will be
checked after this button pressed. New sample will be
created and data structure for this, if the check was
successful. In case of good creation an inscription “OK”
will be shown near the button “Check + Create Sample”. It
appears in Information message “Press button “Start
Analysis” and it appears new sample in the sample tree.
In other case it appears error message with information
what should be changed.
The following will be checked:
• is there the indicated measuring system in the library;
• are the tests carried out licensed;
• is the sample name set and relates to manual input;
• does the inputting sample name exist already and
relates to manual input;
• was the charge indicated and relates to the name input mode “Charge+Index” and “Charge+DateTime”;
• request about distance between plates; it relates to measuring systems plate-plate only.
3 – Start Analysis: Analysis begins after this button was pressed. Check is carried out. If a thermostat is used:
Connection with thermostat will be checked, if this is indicated in the method.
Then the analysis task will be sent to RHEOTEST RN control unit. After that it is necessary to wait as
RHEOTEST RN control unit sends data and analysis would be completed.
One could follow the sequence of this procedure at Information display.
4 – Easy Start: This version of analysis start is right for a lot of similar samples that are tested one after
another in a sequence. The sample will be prepared and analysis will be started. However start takes place in
that case only when all checks were successful. In other case error message appears.
5 – Cancel Analysis: Active analysis will be interrupted at once after pressing. It is possible to cancel analysis
at the stage of analysis preparation. It should be beard in mind that at this error message could appear that
communication is impossible.
After analysis interruption it would be proposed to delete it.
40