• The basic plate with automatic distance adjustment consists of moveable parts. For avoiding injuries,

please apply samples only during standstill of the device.

Attention!

The instrument should not be put into service in case of considerable external damages or heavy

noise during operation.

3 Scope of Supply

3.1 Scope of Supply for Rheometer RHEOTEST ® RN

The measuring instrument Rheometer RHEOTEST ® RN includes:

• basic instrument Rheometer RHEOTEST ® RN (measuring head with highly dynamic measuring drive and

coupling for measuring systems, stand, gas spring and U-shaped support, control unit for power supply,

control of measuring drive, data registration and communication, power cable, USB-Interface cable);

• measuring systems (cylinder– and/or cone/plate and/or plate/plate) - according to the specific order; an

overview of all measuring systems supplied with the instrument is presented in the Overview Measuring

Systems;

• installation data carrier with the software RHEOTEST RN 5 Manager for CR-, CS-, OSC-Tests and with

module for temperature control - by concrete order;

• packaging;

• user manual;

• PC and accessories (have to be ordered separately).

3.2 Scope of Supply for DSR Bitumen Rheometer RHEOTEST ® RN

The scope of supply for a DSR – bitumen rheometer RHEOTEST ® RN consists of:

• Basic instrument Rheometer RHEOTEST ® RN;

• Peltier temperature control unit RHEOTEST ® PP (with power cable and USB-Interface cable) incl.

tempered adapter for measuring systems cone-plate / plate-plate;

• Peltier basic plate, two-sided tempered;

• basic plate support;

• exchangeable plate Ø 25 mm;

• exchangeable plate Ø 8 mm ;

• exchange grip;

• measuring plate P3 (Ø 25mm);

• measuring plate P4 (Ø 8mm);

• set of trimming tools (1 spatula, 1 stripper gripper);

• set of rubber moulds;

• Phobya’s coolant with corrosion protection, if distilled water is used as a coolant. This agent must be

diluted with water in the ratio: 5% of the agent and 95% of the water.

4 Unpacking and Checking

After removing the device and accessories of packaging, please check their completeness according to the

attached delivery note.

In case of any transport damage, the carrier and RHEOTEST must be notified and receive a damage report.

Before starting the operation read the Safety Instructions!