Technical data<br />
The information applies at an ambient temperature of 25 °C<br />
Electrical values<br />
Operating voltage 12 V<br />
Max. input voltage 47 V<br />
Voltage range 8 – 15 V<br />
Shut-off threshold of optional<br />
consumer output<br />
(<strong>de</strong>ep discharge protection)<br />
11 – 11.5 V<br />
Reactivation<br />
12.5 V<br />
Perm. ambient temperature<br />
range<br />
-25 °C – +50 °C<br />
Perm. storage temperature<br />
range<br />
-35 °C – +80 °C<br />
Own consumption 3 mA<br />
Currents<br />
Max. module current 3 A (approx. 45 Wp)<br />
Max. output current 3 A<br />
Optional consumer output max. 3 A switched<br />
Battery capacity 30 – 75 Ah<br />
Charge voltages<br />
Post-charging phase 14.4 V<br />
Trickle charge phase 13.7 V<br />
Main charging phase<br />
changeover voltage<br />
12.5 V<br />
Maximum charge voltage 15.6 V<br />
Temperature compensation -24 mV / K<br />
Mechanical values<br />
Protection class: IP 32<br />
Assembly Wall mounting<br />
Weight 160 g<br />
Connecting terminals 6 mm² (fine-wire)<br />
10 mm² (single-wire)<br />
Dimensions L x W x H: 146 x 90 x 33 mm<br />
Maximum humidity<br />
(non-con<strong>de</strong>nsing)<br />
95 %<br />
21