24.10.2014 Views

Template BA B168xH238 - Hormann.fr

Template BA B168xH238 - Hormann.fr

Template BA B168xH238 - Hormann.fr

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

ENGLISH<br />

14<br />

Displays for Errors/Warnings and Operating Conditions<br />

If there is an error or warning, a number will appear with a rapidly flashing decimal point.<br />

14.1<br />

Display of errors and warnings<br />

Display Error/warning Possible cause Remedy<br />

Reversal limit cannot be set An obstacle was in the way when Remove the obstruction<br />

the SKS/VL reversal limit was set<br />

Partial opening height cannot be<br />

set<br />

The partial opening height is too<br />

close to the CLOSE end-of-travel<br />

position (≤ 120 mm slide travel)<br />

The partial opening height must be higher<br />

Entry not possible<br />

Not possible to give a travel<br />

command<br />

The parameter is set to 0 in<br />

menu 4 and an attempt was<br />

made to activate automatic<br />

timed closing (menu 3,<br />

parameters 1 – 9)<br />

The operator has been blocked<br />

for the control elements and a<br />

travel command was given<br />

Activate the safety device(s)<br />

Run time limitation The belt is torn Exchange the belt<br />

The operator is defective<br />

Release the operator for the control elements<br />

Exchange the operator<br />

System error Internal error Restore the factory setting (see Section 4.6), teach in<br />

the operator again or exchange, if necessary<br />

Force limit<br />

The door is sluggish or does not<br />

move smoothly<br />

Obstruction in door area<br />

Correct the door travel<br />

Static current circuit The wicket door is open Close the wicket door<br />

The magnet has been fitted the<br />

wrong way<br />

The testing result is not OK<br />

Remove the obstruction and teach in the operator<br />

again, if necessary<br />

Fit the magnet correctly (see the instructions for the<br />

wicket door contact)<br />

Exchange the wicket door contact<br />

Photocell No photocell is connected Connect a photocell or set the parameter to 0 in<br />

menu 4<br />

The light beam is interrupted Adjust the photocell<br />

The photocell is defective Exchange the photocell<br />

Closing edge safety device The light beam is interrupted Check the transmitter and receiver and exchange, if<br />

necessary, or exchange the complete closing edge<br />

safety device<br />

8k2 resistance contact strip is<br />

defective or not connected<br />

Check the 8k2 resistance contact strip or connect to<br />

the operator via the 8k2-1T decoder unit<br />

No reference point Power failure Move the door to the OPEN end-of-travel position<br />

The operator has not been<br />

taught in<br />

The operator has not been<br />

taught in yet<br />

Teach in the operator<br />

14.2<br />

Display of the operating conditions of the operator<br />

The operator is in the OPEN end-of-travel position<br />

The operator is in an intermediate position<br />

The operator is currently in motion<br />

The operator is in the CLOSE end-of-travel position<br />

The operator is in the partial opening position<br />

Impulse input <strong>fr</strong>om a radio code<br />

20 TR10A040-E RE / 06.2010