USER SERVICING INSTRUCTIONS<br />
WARNING<br />
Replacing the Fuse<br />
1. Disconnect power<br />
2. Using a flat-blade screwdriver, pry the fuse cover away from<br />
the front panel of the <strong>downdraft</strong> hood.<br />
3. Remove the fuse from the fuse holder by pushing it from the<br />
bottom side with the screwdriver.<br />
Electrical Shock Hazard<br />
Disconnect power before servicing.<br />
Replace all parts and panels before operating.<br />
Failure to do so can result in death or electrical shock.<br />
NOTE: If the hood does not operate, check to see if the circuit<br />
breaker has been tripped and that there is power to the unit.<br />
A<br />
B<br />
A. Fuse holder<br />
B. Remote up/down switch connector<br />
4. To avoid the risk of fire, replace the fuse with a 125 volt,<br />
5 amp non-time delay fuse.<br />
5. Push cover in until it locks into position.<br />
6. Reconnect power.<br />