4.1. Connection of photocells and safety devicesBefore connecting the photocells (or other devices) we advise you toselect the type of operation according to the movement area they haveto protect (see fig.3):Connection of an “edge” safety deviceClosingphotocellsOpening oropening/closingphotocellsENGLISHClosing photocells"Edge" safety devicesFig. 3• Opening safety devices: they operate only during the gate openingmovement and, therefore, they are suitable for protecting the areabetween the opening leaf and fixed obstacles (walls, etc) against therisk of impact and crushing.• Closing safety devices: they operate only during the gate closing movementand, therefore, they are suitable for protecting the closing areaagainst the risk of impact.• Opening/closing safety devices: they operate during the gate openingand closing movements and, therefore, they are suitable for protectingthe opening and closing areas against the risk of impact.• “Edge” safety devices: they operate during the gate opening and closingmovements and, therefore, they are suitable for protecting the areasbetween the moving leaf and fixed obstacles (pillars, walls, etc) againstthe risk of shearing and dragging.• Encoder (optional): operates during the gate opening and closing movementsand, therefore, it is suitable for protecting the opening and closingarea against the risk of impact, crushing, shearing and dragging.If two or more safety devices have the same function (opening, closing,opening and closing, edge), the contacts must be connected to eachother in series (fig. 4). N.C. contacts must be used.Connection of a pair of photocells for openingConnection of a pair of closing photocellsFig. 7Fig. 8Connection of two N.C. contacts in series(e.g. Photocells, Stop, Edge, etc.)Fig. 4If safety devices are not used, jumper connect the terminals as shown infig. 5.Connection of no safety deviceFig. 9Connection of a pair of opening photocells, a pair of closing photocelland an edge safety deviceFig. 5The most common photocell and safety device lay-outs are shown below(from fig. 6 to fig. 13).Connection of a closing safety device and an opening safety deviceFig. 6Fig. 1013

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!