-EN-B- Securing the base using the pegThe <strong>Virax</strong> support stands are provided with 2 types of peg:Peg for concrete;Cannot be reusedPeg for breeze block, etc.;Can be reusedIf the slot cap is fixed and there is a vacuum clamp base seal under the supportstand you must remove them. To remove the slot cap:1 – Loosen and remove the socket head screw.2 – Remove the slot cap and its seal from the base.3 – Mark the position of the attachment hole to bedrilled.4 – Drill the hole (Ø 15) to a depth of 50 mm (A). Yinsert the M12 peg (B) and push it in using the insertiontool (C).5 – Insert the quick tightening screw (D) into the peg.6 – Position the support stand then fix the washer (E)and the attachment nut (F) to the quick tighteningscrew (D)7 – Tighten the nut (F) using an SW 27 wrench8 – Before and after you tighten the nut (F), adjust the4 stop screws to adjust the surface.You must check that the support is solidlysecured.21