Wood burning stove/cooker – <strong>TERMOROSA</strong> <strong>TR</strong><strong>02</strong><br />

In no way should water circulate in the small tank in-between the safety pipe and load pipe, seeing as<br />

this oxidises of the water and consequently this quickly corrodes the thermo cooker and system body.<br />

4. HEAT DISCHARGE VALVE: permits an extra positive safety, capable of preventing boiling, even if<br />

there is no electric power.<br />

It consists of a valve, similar to a pressure safety valve, but differs, seeing that it opens once the precalibrated<br />

temperature (normally 94-95°C) is reache d. It discharges hot water from the system flow<br />

pipe, and the water is replaced with the same quantity of cold water, supplied from the tank vessel load<br />

pipe, this way reducing the excessive heat.<br />

5. SAFETY VALVE FROM 1,5bar: maximum operation pressure allowed for the system is 1,5 bar (equal<br />

to 15m of the water column). Higher pressures can cause deformation and breakage of the boiler body.<br />

6. SAFETY DEVICES envisioned by Regulations in vigour.<br />

7. CIRCULATION PUMP: preferably fitted on the return pipes to avoid diffusion of extremely high<br />

temperature water, however ensure that it does not make water circulate in the open vessel tank as this<br />

would cause continuous oxidation of water which would quickly corrode the boiler body.<br />

It must also be connected electronically so that it will only work when the water temperature reaches<br />

65-70°C. To achieve this one can use the electronic control unit, available as an OPTIONAL with the<br />

thermo cooker, or by using a sleeve thermo switch fitted directly on the flow pipe and calibrated at 65 -<br />

70° C.<br />

8. AUTOMATIC THERMOSTATIC MIXING VALVE - Picture 2<br />

The automatic thermostatic mixer valve finds applications in solid fuel heat generators as it prevents<br />

cold water return in the exchanger.<br />

Routes 1 and 3 are always open and, along with the pump installed on the return (R), the guarantee<br />

water circulation inside the biomass boiler exchanger (CB).<br />

An elevated return temperature, allows efficiency improvement, reduces formation of smoke<br />

condensation and prolongs the boiler life span.<br />

Valves on the market have different calibrations. NORDICA advises use of model 55°c with 1"<br />

hydraulic connections. Once the valve calibration temperature is reached, route 2 is opened and the<br />

boiler water is goes to the system via the flow (M).<br />

CB<br />

TERMOPRODOTTO<br />

IMPORTANT lack of installation of the device voids the heat exchanger warranty.<br />

55°<br />

Picture 2<br />

IMPORTANT: temperature safety sensors must be in place on the machine at a distance no greater than<br />

30 cm from the flow connection of the thermo-product.<br />

Whenever the thermo products lack a device, those missing can be installed on the thermo product flow<br />

pipe, within a distance no greater than 1m from the thermo product.<br />

ATTENTION: For no reason should the fire be lit if the plant has not previously been completely<br />

filled with water. Doing so would seriously damage the entire structure. Filling the<br />

plant must be done via the load pipe direct to the open vessel tank, in a manner that avoids<br />

an excessive pressure of the water network deforming the thermo cooker boiler body. .<br />

The plant must always be full of water even during periods when the thermo cooker is not used. During<br />

winter, an eventual period of rest must be met with the addition of antifreeze.<br />

24 Installation, user and maintenance instructions – EN – Rev.07<br />

1<br />

3<br />

2<br />

M<br />

R