Brother RJ-4030 - Comandi ESCP
Brother RJ-4030 - Comandi ESCP
Brother RJ-4030 - Comandi ESCP
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
ESC/P Command Reference<br />
ESC iX(2<br />
Specify default page length<br />
ASCII: ESC i X ( 2 n1 n2 n3 n4<br />
Decimal: 27 105 88 40 50 n1 n2 n3 n4<br />
Hexadecimal: 1B 69 58 28 32 n1 n2 n3 n4<br />
Parameters<br />
n1: 02h (Fixed)<br />
n2: 00h (Fixed)<br />
00h≤n3≤FFh, 00h≤n4≤1Fh<br />
Description<br />
• Specifies the default page length.<br />
n3+(n4*256): Default page length (dots) (0, 203 through 7999)<br />
*A default page length of 0 indicates the Auto setting.<br />
*The manufacturer’s default is 0.<br />
• This command is a static command.<br />
Remarks<br />
• Invalid if the setting is a value outside of the allowable range<br />
ESC iX(1<br />
Retrieve default page length<br />
ASCII: ESC i X ( 1 n1 n2<br />
Decimal: 27 105 88 40 49 n1 n2<br />
Hexadecimal: 1B 69 58 28 31 n1 n2<br />
Parameters<br />
n1: 00h (Fixed)<br />
n2: 00h (Fixed)<br />
Description<br />
• The default page length setting is returned as 4-byte data.<br />
[1] 02h (Fixed)<br />
[2] 00h (Fixed)<br />
[3, 4] n3 n4 settings<br />
n3+(n4*256): Default page length (dots)<br />
*A default page length of 0 indicates the Auto setting.<br />
• The retrieved value is a value specified by a static command.<br />
- 98 -<br />
5. Control Command Details