12.07.2015 Views

Stratos-Micra 25 Brochure - AirSense Technology Ltd

Stratos-Micra 25 Brochure - AirSense Technology Ltd

Stratos-Micra 25 Brochure - AirSense Technology Ltd

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ClassiFire-3D ® - Artificial Intelligence“ ClassiFire effectively subtracts background smoke, making highsensitivity more usable than ‘absolute scaled’ detectors.”ClassiFire-3D ® is a unique patented 'Artificial Intelligence' night, automatically substituting appropriate system(AI) system which enables <strong>Stratos</strong> detectors to condition sensitivity without the need for external input orthemselves to suit the environment in which they are adjustment. The system literally 'thinks' for itself, even toinstalled. Until the advent of View ClassiFire, ClassiFire-3D the setting Artificial of high the Intelligence degree that in the real-time system will not be fooled by clocksensitivity smoke detection systems was at best a hit or missprocedure, based largely upon the installers estimation of'normal' smoke density. ClassiFire has revolutionised thesetting of High Sensitivity Systems, taking guesswork out ofthe equation and simplifying system set-up. ClassiFire usesa dedicated microprocessor to continually manipulate dataand adjust the sensitivity of the system for a simply definedlevel of performance. ClassiFire discriminates between'smoky' and 'clean' operating periods such as day andClean environmentReal Time ClassiFire Viewer© Copyright 2002 <strong>AirSense</strong> <strong>Technology</strong> <strong>Ltd</strong>Sensitivity: 0.03% obs/mMean: 3.60%Variance: 7.49%FastLearn: ON: 15Day/night:Daychanges or prolonged holiday shut-down periods.ClassiFire ensures that <strong>Stratos</strong>-HSSD operates at maximumsafe sensitivity to give warning of problems earlier thanpreviously considered possible. ClassiFire is the mostcomprehensive intelligence found in any smoke detectionsystem to-date... so sophisticated, that its invention wasconsidered significant enough to allow <strong>AirSense</strong> <strong>Technology</strong>to be the first and only fire detection company to win thecoveted Queen's Award for Technological Achievement.Detector: 001Alarm Factor: 4Fire 1 level: 51.45%Fire 2 level: 80.00%Pre-Alarm level: 42.71%Aux level: 36.94%The Queen’s Awards are the highest accolades that can be bestowed ona UK business. Recognised as the gold standard of corporateachievement, and awarded only to those with a proven record ofexcellence.1999 saw the first ever Queen’s Award for Technological Achievementwith a fire detection company. That company was <strong>AirSense</strong> <strong>Technology</strong>,whose ClassiFire system has changed the face of fire detection.STRATOS-MICRASPECIFICATIONSupply Voltage21.6V - 26.4V DCSize135W x 175H x 80DWeight1.01kgOperating temperature range-10 to +60°COperating humidity range0 - 96% non-condensingSensitivity range (%Obs/m)Min = <strong>25</strong>% Max = 0.03% FSDMaximum sensitivity resolution0.003% obscuration per metreDetection principleLaser light scattering mass detection and particle evaluationParticle sensitivity range 0.003µ to 10µDust discrimination principlePaired pulse amplitudeCurrent consumption<strong>25</strong>0mA @ 24V DCMaximum sampling pipe length50mSampling pipe internal diameter7.5-22mmChamber service intervalsGreater than 8 years (dependant on environment)Dust separator replacement intervalsDependant on environment (typically 3 years)Laser lifetime (MTTF)greater than 1000 yearsProgrammingPCData bus cableRS485 data cableMaximum data bus length between isolators1.2 KmCOUNT FREQUENCY1 2 3 4 5 6 7 8 9 10AUXPRE-ALARMFIRE 1SMOKE DENSITY CLASSESDETECTOR OUTPUT: 3%FIRE 2<strong>AirSense</strong> <strong>Technology</strong> Limited71 Knowl Piece • Wilbury Way • Hitchin • Hertfordshire • SG4 0TYTel. +44 (0)1462 440666 • Fax. +44 (0)1462 440888e-mail: sales@airsense.co.uk • www.airsensetechnology.comSmoky environmentReal Time ClassiFire ViewerCOUNT FREQUENCY© Copyright 2002 <strong>AirSense</strong> <strong>Technology</strong> <strong>Ltd</strong>Sensitivity: 0.98% obs/mMean: 5.04%Variance: 21.38%FastLearn: ON: 15Day/night:DaySMOKE DENSITY CLASSESDetector: 001Alarm Factor: 41 2 3 4 5 6 7 8 9 10AUXPRE-ALARMDETECTOR OUTPUT: 5%Fire 1 level: 68.97%Fire 2 level: 80.00%Pre-Alarm level: 54.31%Aux level: 40.29%FIRE 1FIRE 2<strong>AirSense</strong> <strong>Technology</strong> Benelux BVNoordkade 64 • Gebouw C3, 2741 EZ • Waddinxveen • NederlandTelephone: +31 182 635696 • Facsimile: +31 182 635691e-mail: schakel@cistron.nl<strong>AirSense</strong> OyHuvilaniementie 21 • 48930 Tiutinen • FinlandTel: +358 (0)208-652131 • Fax: +358 (0)401-652131e-mail: matti.valtonen@airsense.inet.fi<strong>AirSense</strong> Engineering SDN BHD49-5 Jalan PJU 1/37 • Dataran Prima • 47301 Petaling JayaSelangor Darul Ehsan • MalaysiaTel. (+ 60) 3 7805 5511 Fax. (+ 60) 3 7805 5840e-mail: airsense@po.jaring.my<strong>AirSense</strong> SECHanla 307 602 • 181 Keumkok-Dong • Boondang-GuSeongnam-Si • Kyungki-Do • 463-7<strong>25</strong> • Seoul • KoreaTel. +82-31-711-1685 • Fax. +82-31-711-1686e-mail: airsense@unitel.co.krIn line with continuous product development we reserve the right to modify or update specifications without notice.PipeCAD, <strong>Stratos</strong>-<strong>Micra</strong>, <strong>Stratos</strong>-HSSD, SenseNET, <strong>AirSense</strong>, ClassiFire and FastLearn are trade marks. HSSD is a Registered Trademark.BR80022 Iss 1ElmTree Design: +44(0)1462 459666

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!