<strong>Mx</strong>-<strong>4000</strong> <strong>Approvals</strong>The <strong>Mx</strong>-<strong>4000</strong> Series <strong>Fire</strong> Alarm Control Panels conform to the following standards:BS EN54-2: 1998BS EN54-4: 1998BS EN60950: 2000BS EN50130-4: 1996Control and Indicating EquipmentPower Supply EquipmentSafety of information technology equipmentProduct Family StandardEMC Directive 89/336/EEC (and the amending directive 92/23/EEC)LV Directive 73/23/EECThe <strong>Mx</strong>-<strong>4000</strong> Series <strong>Fire</strong> Alarm Control Panels also comply with the requirements ofBS5839-1: 2002 A1.The panels are designed and manufactured under a product control procedureaudit system operated by BSI (The Kitemark scheme).The Kitemark Licence (KM69695) covers the following panels.Application NoteModel<strong>Mx</strong>-4100<strong>Mx</strong>-4100/L<strong>Mx</strong>-4200<strong>Mx</strong>-4200/D<strong>Mx</strong>-4400<strong>Mx</strong>-4400/D<strong>Mx</strong>-4400/LE<strong>Mx</strong>-4800Optional Modules:<strong>Mx</strong>p-002<strong>Mx</strong>p-003<strong>Mx</strong>p-009<strong>Mx</strong>p-024/025<strong>Mx</strong>p-013-100<strong>Mx</strong>p-013-200<strong>Mx</strong>p-027<strong>Mx</strong>p-031<strong>Mx</strong>p-032Description1-LP <strong>Fire</strong> Alarm Control Panel – up to 7Ah batteries1-LP <strong>Fire</strong> Alarm Control Panel – deep enclosure up to 12Ah batteries1-2LP <strong>Fire</strong> Alarm Control Panel – up to 17Ah batteries1-2LP <strong>Fire</strong> Alarm Control Panel – deep enclosure up to 38Ah batteries1-4LP <strong>Fire</strong> Alarm Control Panel – up to 17Ah batteries1-4LP <strong>Fire</strong> Alarm Control Panel – deep enclosure up to 38Ah batteries1-2LP <strong>Fire</strong> Alarm Control Panel – large enclosure up to 48Ah batteries1-8LP <strong>Fire</strong> Alarm Control Panel – up to 38Ah batteriesFitted to the above panels.Loop Driver InterfaceNetwork Interface (Standard)Network Interface (Fault Tolerant)20 Zone LED Indicator Panel100 Zone LED Indicator Panel200 Zone LED Indicator Panel100 Zone Mimic LED Indicator PanelPeripheral Bus AdaptorRouting InterfaceDocument Number: 680-114Revision: 02


Quality SystemAdvanced Electronics <strong>Ltd</strong> operates an internal quality system to control the design andmanufacture of safety critical systems. Compliance with ISO9000: 2000 is ensured by regularaudits from both BSI and BRE (LPC).EN54 CertificationThe panels have been tested and certified to EN54-2 and EN54-4 and to the product familystandard EN50130-4 by BSI Product Services (EC Notified Certification Body No. 86, UKAS No.003).The following EN54-2 “Options with Requirements” clauses are also certified:7.8 Outputs to <strong>Fire</strong> Alarm Devices7.9 Outputs to <strong>Fire</strong> Routing Equipment7.11 Investigation Delays to Outputs7.12 Co-incidence Detection7.13 Alarm Counter8.3 Fault Signals from Points8.9 Output to Fault Routing Equipment9.5 Disablement of Points10 Test Condition11 Standardised I/OEMC DirectiveThe panels have been tested to, and have found to be in compliance with, the general emissionsstandards of EN61000-6-3 by York EMC Services (UKAS Accredited #1574).LV DirectiveThe panels have been tested to, and have found to be in compliance with, the product safetyrequirements of EN60950 by BSI Product Services.KitemarkThe panels are designed and manufactured under the BSI Kitemark Licencescheme.In addition to initial product testing this incorporates regular, stringent audits ofboth the manufacturing process and the design process.Page 2 of 4


Test SchedulesThe panels have been tested to the following test schedules.<strong>Fire</strong> AlarmStandardEN54-2EN54-4Description<strong>Fire</strong> detection and fire alarm systems – Part 2: Control and indicating equipment<strong>Fire</strong> detection and fire alarm systems – Part 4: Power supply equipmentEnvironmental and ImmunityStandard Description Test Severity LevelsEN61000-4-2EN61000-4-3ENV50204*EN61000-4-4Immunity to ElectrostaticDischargesImmunity to RFElectromagnetic FieldsImmunity to RFElectromagnetic FieldsImmunity to Fast Transientbursts+/- 8KV Air, +/- 6KV Contact80 to 1000 MHz: Field Strength10V/m50% 200Hz PM: Field Strength 30V/m DwellTime = 3s at the following frequencies:380-420MHz, 900-901MHz, 1.89GHz-1.891GHz, 1.885-2.025GHz, 2.110-2.200GHz+/- 2KV on AC input power ports+/- 1KV on all other signal I/O portsEN61000-4-5 Immunity to surges +/- 2KV Common mode Live-Earth & Neutral-Earth.+/- 1KV Differential mode Live-Neutral.+/- 1KV on all other signal I/O portsEN61000-4-6 Immunity to injected currents 0.15 to 100MHz @ a level of 10VrmsEN61000-4-8*EN61000-4-9*EN61000-4-11Immunity to Power FrequencyMagnetic FieldsImmunity to Pulse MagneticFieldsImmunity to voltage dips &InterruptionsDC & 50Hz, 100A/m and 200A/m for 3s300A/m and 600A/mEN60068-2-1 Test Ab/Ad (Cold) -5C for 16 hours0% to 40% duration 5 cycles maximum (100mS)to 10 cycles maximum (200mS) respectivelyEN60068-2-5 Test Cb (Damp Heat) +40 C @ 93% Relative Humidity for 4 daysEN60068-2-6 Test Fc (Sinusoidal Vibration) 10Hz to 150Hz @ 0.5g* These tests are in addition to, or are at increased severity levels to, the required immunity tests as specified for fire alarm systems in EN54 and EN50130-4.Tested at York EMC Services.EmissionsStandard Description Test Severity LevelsEN61000-6-3 Emissions: Generic standard Conducted emissions EN55022: 1998 Class BRadiated emissions EN55022: 1998 to Class BProduct SafetyStandardEN60950-1DescriptionInformation technology equipment – Safety – Part 1: General RequirementsPage 3 of 4


E&OE – As our policy is one of constant product improvement the right is therefore reserved to modify product specifications without prior notice.Moorland House : Nelson Park : CramlingtonNorthumberland : NE23 1WETel: +44 (0)1670 707 111Fax: +44 (0)1670 707 222www.Advel.co.uk Email: Sales@Advel.co.ukISO9001ISO9001Page 4 of 4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!