<strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Slutrapport: EPF05_33031_0011<br />

Revision nr: 1.05<br />

Rapporteringsdato: 17. april 2008<br />

Projektperiode: 01/10/05 – 01/02/08<br />

Projekt ansvarlig: H2 L<strong>og</strong>ic A/S, Tjelevej 42, 7400 Herning, CVR: 26933048<br />

Øvrige deltagere: IRD Fuel Cells A/S & Mini Crosser A/S


Indholds<strong>for</strong>tegnelse<br />

Slutrapport EFP05_33031_0011<br />

1. INDLEDNING .........................................................................................................................3<br />

1.1. DEFINITIONER ......................................................................................................................3<br />

2. ENGLISH ABSTRACT AND CONCLUSION .................................................................................3<br />

3. DANSK RESUME OG KONKLUSION..........................................................................................3<br />

4. OPNÅEDE RESULTATER ..........................................................................................................3<br />

4. OPNÅEDE RESULTATER ..........................................................................................................3<br />

4.1 - WP1 KRAVSPECIFIKATION AF SYSTEM OG SYSTEMKOMPONENTER.............................................................3<br />

4.2 - WP2 UDVIKLING AF ENGANGSTANK .............................................................................................3<br />

4.2.1. Metanol tankningskoncept.................................................................................................................3<br />

4.3 - WP3 UDVIKLING AF <strong>DMFC</strong> STAK ...............................................................................................3<br />

4.4 - WP4 LUFTFORSYNING OG BEFUGTER ............................................................................................3<br />

4.5 - WP5 KØLER OG KONDENSER.....................................................................................................3<br />

4.6 - WP6 MIXERKREDSLØB ...........................................................................................................3<br />

4.7 - WP7 STYRING OG SOFTWARE....................................................................................................3<br />

4.7.1 FCC – Fuel Cell Controller...................................................................................................................3<br />

4.7.2 SC - System Controller ......................................................................................................................3<br />

4.8 - WP8 KONSTRUKTION AF EFFEKTELEKTRONIK ...................................................................................3<br />

4.8.2. DC/DC konverter .............................................................................................................................3<br />

4.8.3. Valg af batterier...............................................................................................................................3<br />

4.9 - WP9 SYSTEM INTEGRATION......................................................................................................3<br />

4.9.2 System integration............................................................................................................................3<br />

4.9.3. Fremtidig integration ........................................................................................................................3<br />

4.10 TEST, DOKUMENTATION OG RAPPORTERING .....................................................................................3<br />

5. KOMMERCIALISERING AF <strong>DMFC</strong> TEKNOLOGI I EN MINI CROSSER.........................................3<br />

5.1. TARGET SPECIFICATIONS FOR <strong>DMFC</strong> SYSTEM TIL MINI CROSSER.............................................................3<br />

5.2. KOMMERCIALISERING AF <strong>DMFC</strong> TEKNOLOGIEN SOM BATTERY REPLACEMENT .................................................3<br />

6. DISKUSSION OG KONKLUSION ..............................................................................................3<br />

7. SAMMENLIGNING AF OPNÅEDE MÅL MED PROJEKTETS MÅL ..................................................3<br />

8. DET VIDERE FORLØB..............................................................................................................3<br />

9. PUBLIKATIONER ....................................................................................................................3<br />

BILAGSLISTE .............................................................................................................................3<br />

BAGGRUNDS REFERENCER .........................................................................................................3<br />

Side 2 / 26


1. Indledning<br />

Slutrapport EFP05_33031_0011<br />

Denne slutrapport skildre <strong>for</strong>sknings- <strong>og</strong> udviklingsarbejdet i projektet: ”<strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong><br />

<strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong>” støttet af EFP05 pr<strong>og</strong>rammet.<br />

Projektets overordnede mål har været at udvikle et <strong>DMFC</strong> brændselscellesystem der kan oplade batterier<br />

<strong>for</strong> anvendelse i <strong>intern</strong> <strong>transport</strong> samt <strong>mobile</strong> <strong>og</strong> stationære <strong>anlæg</strong>. I projektet integreres <strong>DMFC</strong> <strong>modul</strong>et i<br />

en el-scooter til handicappede eller gangbesværede <strong>og</strong> testes under <strong>for</strong>skellige drifts cykler i en laboratorie<br />

test, med efterfølgende afprøvning af køretøjsproducenten . Projektet er et udviklingsprojekt udført i<br />

samarbejde mellem H2-L<strong>og</strong>ic, IRD Fuel Cells <strong>og</strong> MiniCrosser.<br />

IRD Fuel Cells ønsker at fokuser sine aktiviteter inden<strong>for</strong> udvikling af et såkaldt <strong>DMFC</strong> <strong>modul</strong>. H2 L<strong>og</strong>ic<br />

ønsker at være system integrator der bygger færdige brændselscellesystemer <strong>og</strong> integrerer disse i køretøjer.<br />

Mini Crosser er producent af el-scootere <strong>og</strong> har et ønske om at kunne tilbyde kunderne alternativer<br />

til konventionelle batterier. De 3 partnere er således gået sammen i dette projekt <strong>for</strong> at afdække om<br />

<strong>DMFC</strong> teknol<strong>og</strong>ien kan være et reelt alternativ en el-scooter.<br />

I tillæg til projektets <strong>for</strong>mål har partnernes ambitiøse målsætning været at udvikle et komplet brændselscellesystem<br />

der direkte kunne passe i batterikassen på et køretøj, samt indsamle erfaringer <strong>for</strong> drift af et<br />

<strong>DMFC</strong> brændselscellesystem hos en slutbruger.<br />

Endelig bliver de kommercielle aspekter omkring <strong>DMFC</strong> teknol<strong>og</strong>ien vurderet i <strong>for</strong>hold til anvendelse i<br />

<strong>transport</strong> applikationer <strong>og</strong> muligheden <strong>for</strong> anvendelse af den udviklede <strong>DMFC</strong> brændselscelle generator i<br />

andre produkter.<br />

Spørgsmål til rapporten <strong>og</strong> projektet han rettes til projektlederen eller en af projektdeltagerne.<br />

Projektleder:<br />

Jacob Hansen, H2 L<strong>og</strong>ic A/S, jh@h2l<strong>og</strong>ic.dk<br />

Projektdeltagere:<br />

Madeleine Odgaard, IRD Fuel Cells A/S, mod@ird.dk<br />

Klaus Smedegaard Mini Crosser A/S<br />

1.1. Definitioner<br />

Der anvendes en række terminol<strong>og</strong>ier i rapporten <strong>og</strong> projektet som her bliver defineret.<br />

Køretøj / MiniCrosser / El-scooter<br />

Køretøjet der anvendes i projektet. MiniCrosser T140 4-hjulet. Se yderligere på www.minicrosser.dk<br />

<strong>DMFC</strong> System / Brændselscellesystem<br />

Det samlede system der installeres på køretøjet. Indeholdende <strong>DMFC</strong> (Direct Methanol Fuel Cell)Modul, power elektronik,<br />

batterier m.v. <strong>DMFC</strong> System ekskl. <strong>DMFC</strong> <strong>modul</strong>et er udviklet <strong>og</strong> leveret af H2 L<strong>og</strong>ic.<br />

<strong>DMFC</strong> Modul<br />

<strong>DMFC</strong> <strong>modul</strong>et indeholder <strong>DMFC</strong> stak samt de nødvendige kredsløb omkring stakken så som køling, fuel mixture, katode<br />

system, styring m.v. <strong>DMFC</strong> Modulet er udviklet <strong>og</strong> leveret af IRD Fuel Cells.<br />

Side 3 / 26


2. English abstract and conclusion<br />

Slutrapport EFP05_33031_0011<br />

The objective of the project has been to develop a compact fuel cell generator using methanol as fuel.<br />

The <strong>DMFC</strong> <strong>modul</strong>e will be tested as power generator <strong>for</strong> <strong>intern</strong>al <strong>transport</strong> using a Mini Crosser electric<br />

wheelchair <strong>for</strong> elderly and disabled people. The main advantage is the potential enhanced operation time<br />

(enhanced range) and the abbreviated recharge time compared with rechargeable batteries. The project<br />

approach was to use a hybrid system comprising a <strong>DMFC</strong> and a battery. The Hybrid system enables the<br />

usage of the battery to cover the dynamic power requirements while operating the <strong>DMFC</strong> generator at a<br />

constant load charging the battery.<br />

The project result is a functioning vehicle with a 600W <strong>DMFC</strong> system installed. The <strong>DMFC</strong> system has<br />

been tested independently and t<strong>og</strong>ether with the vehicle where test results have been gathered. It was<br />

not possible within the project to make a compact installation in the existing battery box of the vehicle,<br />

but it is illustrated that it will be possible to make the full installation of a 2 nd generation system in the<br />

vehicle. On the commercial side it is concluded that there can be a potential market entry opportunity if<br />

the <strong>DMFC</strong> system can meet commercialisation targets. It is also concluded that usage of a <strong>DMFC</strong> system<br />

in a closed wheel chair would give the possibility to use the produced heat from the fuel cell and thereby<br />

eliminate the requirement <strong>for</strong> an additional heater on the vehicle.<br />

3. Dansk resume <strong>og</strong> konklusion<br />

Projektets <strong>for</strong>mål har været at udvikle <strong>og</strong> demonstrere 1. generation Direct Methanol Fuel Cell system<br />

anvendt i en Mini Crosser (el-scooter). Ved at bruge metanol som brændstof vil det være muligt at <strong>for</strong>øge<br />

aktionsradius markant i <strong>for</strong>hold til konventionel batteriteknol<strong>og</strong>i, det vil ligeledes <strong>og</strong>så være muligt at lave<br />

hurtig optankning <strong>og</strong> dermed eliminere spildtid til opladning af batterier. Konceptet hat været at udvikle<br />

et hybrid system bestående at <strong>DMFC</strong> <strong>modul</strong> <strong>og</strong> batteri, hvorved brændselscellen kun skal producere<br />

gennemsnitsenergi<strong>for</strong>brug <strong>og</strong> batterierne klarer peak<strong>for</strong>brug under opstart <strong>og</strong> acceleration.<br />

Projektets resultat er et fungerende 600W <strong>DMFC</strong> system der succesfuldt er integreret <strong>og</strong> demonstreret på<br />

en Mini Crosser. Der er blevet indsamlet driftsdata på <strong>DMFC</strong> system <strong>og</strong> køretøj, <strong>og</strong> disse data vil blive<br />

brugt i det videre arbejde om udvikling af næste generation <strong>DMFC</strong> system. Der er som en del af projektet<br />

lavet kommercielle analyser <strong>og</strong> overvejelser om kommercialisering af <strong>DMFC</strong> teknol<strong>og</strong>ien. Fuld kommerciel<br />

target pris i en Mini Crosser er således 4000kr <strong>for</strong> et 600W system, men i en Mini Crosser med kabine vil<br />

brændselscellens overskudsvarme kunne bruges til opvarmning af køretøjet hvorved anden opvarmning<br />

spares <strong>og</strong> kommercialiseringsprisen bliver således 10.000kr. Konklusionen på projektet er at teknol<strong>og</strong>ien<br />

<strong>for</strong>ventes at kunne gøres kommerciel i en Mini Crosser. Det må d<strong>og</strong> <strong>og</strong>så konkluderes at der skal yderligere<br />

F/U arbejde til inden <strong>DMFC</strong> teknol<strong>og</strong>ien er kommerciel.<br />

MiniCrosser T140<br />

Side 4 / 26


4. Opnåede resultater<br />

Slutrapport EFP05_33031_0011<br />

Dette afsnit dokumenterer resultaterne fra de tekniske arbejdspakker i projektet. I arbejdspakkerne er<br />

hovedresultaterne dokumenteret, mens yderligere in<strong>for</strong>mation er dokumenteret i bilag.<br />

4.1 - WP1 Kravspecifikation af system <strong>og</strong> systemkomponenter<br />

For at identificere den overordnede kravspecifikation til <strong>DMFC</strong> Systemet <strong>og</strong> derefter de enkelte delsystemer<br />

blev der lavet en række tests på køretøjet, <strong>for</strong> at identificere effekt<strong>for</strong>brug i <strong>for</strong>skellige driftssituationer.<br />

Hele kravspecifikationen kan ses i bilag1.<br />

Ved normal kørsel er effekt<strong>for</strong>bruget på køretøjet 480W ved maksimal hastighed (15km/t) på lige vej. I<br />

situationer hvor der køres op ad bakke eller der accelereres stiger effekt<strong>for</strong>bruget til over 1000W. <strong>DMFC</strong><br />

stakken er det dyreste komponent i systemet <strong>og</strong> der <strong>for</strong>ventes længst levetid <strong>for</strong> stakken ved et stabilt<br />

strømtræk. Løsningen om udvikling af et hybrid system hvor <strong>DMFC</strong> stakken kan levere effekt svarende til<br />

gennemsnitlig <strong>for</strong>brug <strong>og</strong> batterierne så fungerer som bufferlager syntes der<strong>for</strong> oplagt.<br />

Baseret på den overordnede kravspecifikation med driftsegenskaber <strong>og</strong> data <strong>for</strong> køretøjet, er effekt krav<br />

til <strong>DMFC</strong> Modulet specificeret. De overordnede krav <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et er:<br />

• Celle type: <strong>DMFC</strong> (Direct Methanol Fuel Cell)<br />

• Brændstof: kommerciel tilgængelig metanol (ikke speciel laboratorie renhed)<br />

• Nominal Power: 600 W<br />

• Omgivelses temperatur under drift: -15°C til 35°C<br />

• Omgivelses temperatur ved stand-by: > 0°C op til 35°C<br />

• Støj: generelt lav<br />

• Rystelser: skal kunne modstå vibrationer ved normal kørsel.<br />

På figur1 ses en simplificeret ombygning af <strong>DMFC</strong> systemets delsystemer.<br />

Figur 1 – Skematisk visning af <strong>DMFC</strong> systemets delsystemer<br />

Side 5 / 26


Slutrapport EFP05_33031_0011<br />

<strong>DMFC</strong> Modulet består af brændselscelle stak med tilhørende systemkomponenter (Balance-of-Plant). Delkomponenterne<br />

består af følgende hovedkredsløb:<br />

• Ekstern metanol tank<br />

• Luft<strong>for</strong>syning<br />

• Køler/kondenser<br />

• Mixerkredsløb<br />

• Styring <strong>og</strong> kontrol<br />

Det var et ønske fra IRD at styringen blev opdelt i 2, et system udviklet af IRD der kan håndterer styringen<br />

af selve <strong>DMFC</strong> <strong>modul</strong>et <strong>og</strong> et system udviklet af H2 L<strong>og</strong>ic der kunne håndtere hybridisering, tankning<br />

<strong>og</strong> interface til brugeren.<br />

Kravspecifikationen til effektelektronik blev sat ud fra <strong>DMFC</strong> <strong>modul</strong>ets arbejdsområder samt køretøjets<br />

dynamiske effekt<strong>for</strong>brug.<br />

Kravspecifikation effektelektronik:<br />

• Simpel <strong>og</strong> kompakt løsning<br />

• Step-up<br />

• Minimal effekt tab i DC/DC konverter, minimum 92% virkningsgrad<br />

Kravspecifikation metanoltank:<br />

• Kapacitet til minimum 4 liter metanol, da dette vil <strong>for</strong>doble aktionsradius.<br />

• Tankmateriale skal kunne støbes i masseproduktion<br />

Ud fra de ovenstående kravspecifikationer blev udviklingsarbejdet påbegyndt i de respektive arbejdspakker<br />

(WP’s)<br />

4.2 - WP2 Udvikling af engangstank<br />

Metanoltanke i køretøjer kan på overordnet niveau inddeles i metaltanke <strong>og</strong> plastictanke. I bilindustrien<br />

er der groft sagt siden midten af 1980’erne sket et skift fra ståltanke belagt med en 8 % tin- bly belægning<br />

til <strong>for</strong>skellige typer af plastictanke. Allerede i 1993 var 80 % af alle tanke i personbiler solgt i Europa<br />

således lavet af plasticmateriale, medens det sammenlignelige tal <strong>for</strong> USA samme år var 24 % <strong>og</strong> <strong>for</strong> Japan<br />

5 %. Siden er andelene i de respektive regioner sandsynligvis kun steget yderligere. Det vurderes at<br />

det vil være <strong>for</strong> dyrt at se yderligere på metaltanke, idet <strong>for</strong>men vil være betydeligt dyrere end en <strong>for</strong>m<br />

til produktion af plasttanke. Brændselscellen stiller samtidigt krav til renligheden af metanol, hvor<strong>for</strong> metaltanke<br />

frarådes grundet muligheden <strong>for</strong> korrosion.<br />

Plasttanken skal produceres i Polyethylen, der <strong>og</strong>så er kendt som PE. PE findes i <strong>for</strong>skellige kvaliteter, der<br />

benævnes efter tæthed. Alle PE typer er meget bestandige over <strong>for</strong> vand, fugt <strong>og</strong> de fleste organiske opløsningsmidler.<br />

Tankene er ikke nødvendigvis bestandige over<strong>for</strong> UV-lys. Eftersom metanol kan trænge<br />

gennem low density polyethylen (LDPE), liniear low density polyethylene (LLDPE) <strong>og</strong> almindelig polyethylene<br />

(PE) i mindre omfang skal der benyttes high density polyethylen (HDPE). HDPE er stærkere <strong>og</strong> stivere<br />

end andre polyethylener, men ikke så sej. Hvor meget metanol der trænger gennem HDPE er en funktion<br />

af overfladearealet <strong>og</strong> plasttykkelsen.<br />

De typer af tanke der kan anvendes i dette projekt vil på mange måder minde om den type dunke der<br />

anvendes til sprinklervæske. På billede 1 (næste side) ses Polyethylene dunke fra United States Plastic<br />

Corporation til opbevaring af sprinklervæske. Dunken til venstre kan rumme et indhold på 2½ gallons<br />

(ca. 9,5 L).<br />

Som eksterne dunke kan anvendes almindelige plastic ”jerrycans”. Denne type dunke kendes fra bagagerummet<br />

i ens bil <strong>og</strong> dunke der benyttes til påfyldning af benzin på plæneklippere. Eksempler på sådanne<br />

jerrycans kan ses på billede 02 (næste side).<br />

Side 6 / 26


Slutrapport EFP05_33031_0011<br />

Billede 1 – Polyethylene tanke Billede 2 – Jerrycans<br />

4.2.1. Metanol tankningskoncept<br />

Inden valg af tanktype er det væsentligt at identificere hvilket tankningskoncept der vil gøre metanol distribution<br />

<strong>og</strong> anvendelse simplest <strong>for</strong> slutbrugeren. Slutbrugerne bor decentralt i byer <strong>og</strong> på landet, <strong>og</strong><br />

det <strong>for</strong>ventes således ikke som en holdbar løsning hvis slutbrugeren skal køre <strong>for</strong>bi en tankstation hvor<br />

metanol kan tankes. Metanol skal distribueres ud til slutbrugerne, hvilket nemmest gøres via den kommunale<br />

hjemmepleje, da hjemmeplejen allerede er i daglig kontakt med en del af brugerne af elscootere.<br />

Det vil være lovgivningsmæssigt muligt <strong>og</strong> sikkerhedsmæssigt <strong>for</strong>svarligt at distribuere metanol<br />

via hjemmeplejen jf. metanol distributionsanalysen der er vedlagt som bilag2.<br />

Når metanol er distribueret ud til slutbrugerne kan der anvendes 2 <strong>for</strong>skellige tankningskoncepter:<br />

Koncept nr. 1.<br />

Er en engangsdunk der både bruges til opbevaring af metanolen ved distribution <strong>og</strong> som en udskiftelig<br />

tank i <strong>for</strong>bindelse med selve <strong>DMFC</strong> systemet.<br />

Koncept nr. 2.<br />

Indebærer distribution i tanke der kan genbruges, hvorefter metanolen overføres til en integreret<br />

tank på køretøjet.<br />

Den helt klare <strong>for</strong>del ved engangsdunke er at brugeren på ingen måder kommer i kontakt med metanolen.<br />

Der er desuden den <strong>for</strong>del at lukkede systemer ikke kan <strong>for</strong>urenes, hvilket <strong>for</strong>ventelig vil give en<br />

længere holdbarhed af brændselscellerne. Ulempen ved et sådant koncept er at man kommer til at stå<br />

med en frygtelig masse dunke der uden tvivl i sig selv vil være en miljøbelastning. Ved at benytte dunke<br />

der kan bruges gang efter gang undgår man denne miljøbelastning. Faste tanke kendes fra både biler,<br />

motorcykler, scootere, plæneklippere, motorsave <strong>og</strong> <strong>mobile</strong> strøm<strong>for</strong>syninger. Det vurderes at brugerne<br />

vil syntes bedst om interaktionen med faste tanke, idet det minder om det de kender fra ovennævnte<br />

maskiner <strong>og</strong> idet de selv kan bestemme hvor meget brændstof der skal påfyldes.<br />

Yderligere et argument <strong>for</strong> koncept 2 viste sig i løbet af projektet, da det blev konkluderet at pladsen til<br />

tanken blev meget begrænset, <strong>og</strong> det ikke ville være muligt at bruge en standard tank hvis hele <strong>DMFC</strong><br />

systemet skulle installeres i batterikassen på køretøjet. Ved at udvikle en fastmonteret tank på køretøjet,<br />

vil denne i en færdig kommerciel løsning kunne vakuum<strong>for</strong>mes til præcist at udfylde overflødige hulrum<br />

<strong>og</strong> på den måde give mest muligt plads til metanoltanken.<br />

Konklusionen på tankningskoncept er således koncept 2, hvor der skal bruges 2 tanke. 1 integreret <strong>for</strong>mstøbt/vakuum<strong>for</strong>met<br />

tank som en del af <strong>DMFC</strong> <strong>modul</strong>et, <strong>og</strong> en genanvendelig distributionsdunk.<br />

For at sikre, at brugeren ikke kan komme i berøring med metanolen er der undersøgt <strong>for</strong>skellige <strong>for</strong>mer<br />

<strong>for</strong> sammenkoblinger mellem metanoldunken <strong>og</strong> den integrerede tank på køretøjet. Valget er faldet på<br />

modellen kaldet ”Flutite”, dette er et produkt der sikre, når den er monteret på en tank, at brugeren ikke<br />

kan komme i kontakt med metanolen. Koblingerne klikkes sammen <strong>og</strong> påfyldningen kan begynde. Når<br />

den ønskede mængde metanol er overført fra den ene tank til den anden kobles de fra hinanden <strong>og</strong> vil<br />

automatisk lukke begge ventiler. På billede 3 ses han/hun versionen af koblingerne.<br />

Side 7 / 26


Slutrapport EFP05_33031_0011<br />

Der er til projektet indkøbt et sæt koblinger, hvor test har vist positive resultater med meget begrænset<br />

metanolspild under optankning. Men grundet krav til renlighed af metanolen vil det være nødvendigt at<br />

udvikle koblinger i rustfrit stål i stedet <strong>for</strong> de nuværende i messing. Flutite er interesserede i at indgå i et<br />

udviklingssamarbejde om udvikling af koblinger af rustfrit stål såfremt det kan dokumenteres at de vil<br />

kunne anvendes i et kommercielt produkt.<br />

I det færdige prototype køretøj anvendes der ikke Flutite koblinger grundet bekymring <strong>for</strong> <strong>for</strong>urening af<br />

metanolen. Efter det blev klart at <strong>DMFC</strong> <strong>modul</strong>et ikke kunne integreres i den ønskede batteribakke på<br />

køretøjet blev det valgt at bygge en simpel metanoltank til prototypekøretøjet. Dette er nærmere <strong>for</strong>klaret<br />

under afsnit 4.9. – System integration.<br />

4.3 - WP3 Udvikling af <strong>DMFC</strong> stak<br />

Der er i projektet fremstillet ialt 3 <strong>DMFC</strong> stakke (Figur 4). Baseret på specifikationen <strong>for</strong> brændselscelle<br />

<strong>modul</strong>et (WP1), blev der fremstillet en <strong>DMFC</strong> stak baseret på 35 celler, med hver et aktivt areal på 180<br />

cm2. Stakkens blev designet til direkte integration med en befugter (WP4). De indledende laboratorietest<br />

af stakkens ydeevne viste, at stakken opfylder krav til effekt i henhold til specifikationen. Endeplade materialet<br />

<strong>og</strong> processen <strong>for</strong> fremstilling af endepladerne viste desværre under længere tids driftstimer ustabil,<br />

resulterende i utætte endeplader. Parallelt med fokus på analyse, optimering <strong>og</strong> løsning af problemet,<br />

blev der fremstillet en 1 kW <strong>DMFC</strong> baseret på tidligere udviklet endeplader. Denne stak er anvendt til udvikling<br />

<strong>og</strong> test af systemkomponenter (Balance-of-Plant) i arbejdspakkerne WP4-WP6). For integration i<br />

den færdige prototype, blev endepladerne re-designet <strong>og</strong> materialet mekanisk stabiliseret.<br />

Stakkens ydeevne er vist i figur 5. Ved en driftstemperatur på 75°C, støkiometri <strong>for</strong> henholdsvis luft <strong>og</strong><br />

metanol flow på λ air =3.0 <strong>og</strong> λ metanol =6.0 <strong>og</strong> en 6-lags befugter er den opnåede effekt 680 W e ved 45 A.<br />

1. Prototype stak 1 kW stak anvendt til udvikling <strong>og</strong> test af<br />

systemkomponenter<br />

Figur 4 – <strong>DMFC</strong> stakke udviklet i projektet.<br />

Billede 3 – Flutite metanol koblinger<br />

2. prototype stak anvendt til<br />

integration i <strong>DMFC</strong> <strong>modul</strong>et<br />

Side 8 / 26


Figur 5 – <strong>DMFC</strong> Stakkens ydeevne<br />

Karakteristika <strong>for</strong> <strong>DMFC</strong> stakken er:<br />

Nominel strøm: 45 A<br />

Nominel effekt: 680 W<br />

Effektivitet (HHV), nominel: η el= 35 %<br />

Effekttæthed: 120 W/l<br />

Slutrapport EFP05_33031_0011<br />

4.4 - WP4 Luft<strong>for</strong>syning <strong>og</strong> befugter<br />

Kritisk <strong>for</strong> drift af <strong>DMFC</strong> stakken er opretholdelse af den korrekte fugtighed overalt i cellen <strong>og</strong> ensartet<br />

korrekt arbejdstemperatur. Desuden er det af energiøkonomiske årsager vigtigt at holde et lavt (<strong>for</strong>holdet<br />

mellem tilført ilt <strong>og</strong> <strong>for</strong>brugt ilt). Der<strong>for</strong> <strong>for</strong>synes stakken med luft gennem en befugter der giver en<br />

nær 100% befugtning af den indgående luft, samtidig med at den bringer temperaturen på tilgangsluften<br />

tæt på temperaturen af afgangsluften. Da brændselscellen producerer vand på ilt-siden benyttes afgangsluftens<br />

vand til at befugte tilgangsluften. Stakkens størrelse <strong>og</strong> dermed behovet <strong>for</strong> luft tilførsel angiver<br />

størrelsen (antal lag) <strong>for</strong> befugteren. Udgangspunktet i design fasen blev baseret på en 12-lags befugter.<br />

For optimal dimensionering af befugteren blev der i projektet fremstillet <strong>og</strong> testet 3 <strong>for</strong>skellige<br />

befugter størrelser. Resultaterne viste at en 6-lags befugter kunne opfylde systemets krav, resulterende i<br />

55% volumen reduktion <strong>for</strong> befugteren. Brændselscellen producerer vand på ilt siden (katoden), <strong>og</strong> samtidig<br />

<strong>for</strong>bruges vand på metanol siden (anoden). For at opretholde vandbalance <strong>og</strong> stabilitet i systemet,<br />

skal den korrekte mængde vand kondenseres fra overskudsluften. Maksimalt må der <strong>for</strong>dampe 0.18 g<br />

vand/time ved nominel drift på 45 A. Dette er i projektet opnået med cirkulation af luft gennem stakken<br />

med overskud af ilt (λ=3) samt nedkøling af afgangsluften til under 45 °C. For at minimere parasit strøm<br />

<strong>for</strong> luftpumpen <strong>og</strong> dermed opnå højere systemeffektivitet, er kredsløbet konstrueret med styring ud fra<br />

energibehov <strong>og</strong> cellespænding. Da <strong>modul</strong>et i projektet skal anvendes udendørs, filtreres al luft til systemet<br />

gennem et finfilter. Hermed sikres <strong>modul</strong>et imod <strong>for</strong>urening af brændselscellen.<br />

Det komplette delsystem bestående af luftpumpe, filter <strong>og</strong> befugter er integreret med brændselscelle<br />

stakken <strong>og</strong> afprøvet i en laboratorie test før <strong>modul</strong> integration. Ved nominel drift udgør effekt<strong>for</strong>bruget til<br />

luftkredsløbet 20 W eksklusiv vandkondenserings enheden (se under WP5).<br />

Side 9 / 26


Slutrapport EFP05_33031_0011<br />

4.5 - WP5 Køler <strong>og</strong> kondenser<br />

Ved nominel drift vil ca. 65 % af energien fra brændselscellen produceres som varme. Af hensyn til stakkens<br />

levetid <strong>og</strong> optimal per<strong>for</strong>mance, skal systemet <strong>for</strong>hindre overophedning (> 85°C).<br />

Medens en højere celletemperatur fremmer metanol oxidationsreaktionen (<strong>og</strong> dermed elektrisk virkningsgrad),<br />

vil den højere temperatur <strong>og</strong>så stille større krav til regenerering af vand i en kondenseringsproces.<br />

Desuden vil den højere temperatur <strong>for</strong>stærke tab af metanol igennem elektrolytmembranen, <strong>og</strong><br />

yderligere reducerer effektiviteten <strong>og</strong> systemets energitæthed.<br />

Den <strong>intern</strong>e køling af brændselscellen kontrolleres hovedsaglig via det <strong>intern</strong>e metanol/vand kredsløb.<br />

Den eksterne køling designes i overensstemmelse med nedenstående:<br />

Kapacitet: 1500 W<br />

Driftstemperatur: > 0°C op til 85°C<br />

Omgivelses temperatur under drift: -15 °C til 35°C<br />

Omgivelses temperatur ved stand-by: > 0°C op til 35°C<br />

Materiale: Metanol/vand tolerant (max. 6.5 wt%)<br />

Korrosions stabilt<br />

For at øge den samlede virkningsgrad ville det være optimalt med passiv køling <strong>for</strong> således ikke at <strong>for</strong>bruge<br />

energi på at komme af med overskudsvarmen, men dette kræver en <strong>for</strong>holdsvis stor køler ved 1<br />

kW <strong>DMFC</strong> systemer. Da dette <strong>modul</strong> skal integreres i køretøjet <strong>og</strong> der<strong>for</strong> skal fylde <strong>og</strong> veje så lidt som<br />

muligt, vil det være mere optimalt, hvis en mindre køler med monterede blæsere benyttes til opgaven.<br />

Denne løsning giver naturligvis et energi<strong>for</strong>brug, men hvis køleren monteres <strong>for</strong>rest på køretøjet <strong>og</strong> derved<br />

påvirkes af vinden ved kørsel, vil der i det væsentligste udelukkende være et energi<strong>for</strong>brug når udetemperaturen<br />

er høj, samt når køretøjet står stille.<br />

I projektet var det ikke muligt at omkonstruere køretøjet <strong>og</strong> designe en køler specielt til <strong>for</strong>målet. Der er<br />

i projektet der<strong>for</strong> indkøbt to størrelser kølere. Begge er valgt i samarbejde med Flexcoil, hvor den ene<br />

kan køle passivt <strong>og</strong> den anden med <strong>for</strong>ceret luft. Baseret på laboratorietest blev køler med <strong>for</strong>ceret luft<br />

valgt, <strong>og</strong> styring af den termiske kontrol udviklet <strong>for</strong> stabil drift <strong>og</strong> temperatur (<strong>for</strong> eks. se figur 6).<br />

Figur 6 – Forskellige styring af termisk kontrol<br />

Side 10 / 26


Slutrapport EFP05_33031_0011<br />

Alle materialer der er i kontakt med metanolblandingen er i AISI316 rustfast stål. Herved opnås mindst<br />

mulig afsmitning af metal-ioner til MEA´en. Generelt ville plastmaterialer være at <strong>for</strong>etrække, men disse<br />

leder ikke varmen så godt som stål, <strong>og</strong> vil der<strong>for</strong> <strong>for</strong>holdsmæssigt optage større plads. Køleren blev integreret<br />

i selve <strong>DMFC</strong> <strong>modul</strong>et. I <strong>for</strong>bindelse med integration af kommende <strong>modul</strong>er i køretøjer, vil det<br />

uden tvivl være muligt at designe en køler placeret eksternt <strong>og</strong> tilpasset køretøjet <strong>og</strong> dermed opnå en<br />

bedre systemløsning. Den termiske kontrol er ligeledes tæt knyttet til opretholdelse af vandbalancen i<br />

systemet. Der er i <strong>modul</strong>et implementeret en vandkondenseringsenhed, <strong>for</strong> regenerering af den nødvendige<br />

mængde vand (jvf. WP6). Det samlede effekt<strong>for</strong>brug til køling <strong>og</strong> kondensering ved nominel drift<br />

udgør 15 W.<br />

4.6 - WP6 Mixerkredsløb<br />

Brændselscelle stakken bruger lige dele vand <strong>og</strong> metanol som<br />

brændstof i en 1.0 M (nominel) blanding. Metanolen <strong>for</strong>synes<br />

fra en ekstern metanol tank (WP2), <strong>og</strong> vandet fra afgangen på<br />

luftsiden via befugter/kondenser (WP4). Kredsløbet er designet<br />

så tilførsels af metanol/vand er i overensstemmelse med opretholdelse<br />

af en konstant koncentration. Tilspædningen der<br />

styres af Fuel Cell Controlleren (WP7), er baseret på strøm <strong>og</strong><br />

niveaumålere.<br />

I projektet er der designet en <strong>intern</strong> mixertank. Mixertanken<br />

integrerer vand, brændstof, køling, filtrering <strong>og</strong> CO 2 håndtering<br />

i en enhed. Til <strong>DMFC</strong> prototype <strong>modul</strong>et er delkomponenterne<br />

<strong>og</strong> den <strong>intern</strong>e mixertank fremstillet i et <strong>for</strong>mstabilt<br />

plastmateriale på en CNF fræser. Der er i projektet arbejdet<br />

med design omkring konstruktion af mixertank <strong>og</strong><br />

mixerkredsløb til kommende <strong>modul</strong>er i køretøjer. Redesignes<br />

stak endepladen vil mixeren kunne placeres direkte på stakken<br />

(se figur 7). Dette vil reducere procesvejen <strong>og</strong> behov <strong>for</strong> dyre<br />

koblinger <strong>og</strong> infrastrukturelementer vil kunne reduceres.<br />

Designet er egnet til <strong>for</strong>mstøbte emner der vil kunne sprøjtestøbes<br />

prisbilligt ved produktion i større styktal.<br />

Figur 7 – Design af <strong>DMFC</strong> mixertank <strong>for</strong> evt.<br />

fremtidig produktion<br />

4.7 - WP7 Styring <strong>og</strong> software<br />

Det blev igennem projektet udviklet 2 styringer 1 styring til <strong>DMFC</strong> <strong>modul</strong>et (Fuel Cell Controler, FCC) <strong>og</strong> 1<br />

styring til styring af hele systemet <strong>og</strong> dets interface med køretøjet (System Control, SC). På sigt i et<br />

kommercielt produkt vil der kun være 1 styring, men det blev vurderet at det nemmeste interface mellem<br />

IRD’s <strong>og</strong> H2 L<strong>og</strong>ics arbejdspakker var en kommunikation mellem de 2 styringer.<br />

H2 L<strong>og</strong>ic <strong>og</strong> IRD har i fællesskab besluttet at al kommunikation mellem SC <strong>og</strong> FCC sker via RS232 Seriel<br />

kommunikation.<br />

I FCC implementeres 6 tilstande, der kan opdeles i to kategorier: On <strong>og</strong> Off. Set ”udefra” – altså <strong>for</strong> at<br />

styre brændselscellen – er det nok at arbejde med kun de to kategorier: On <strong>og</strong> Off. En nærmere beskrivelse<br />

af kategorier <strong>og</strong> tilstande findes i Tabel 8.<br />

Side 11 / 26


Tabel 8. Kategorier <strong>og</strong> tilstande I FCC (Fuel Cell Controller).<br />

Kategori<br />

(input fra SC)<br />

Off<br />

On<br />

Mode (FCC <strong>intern</strong> tilstand<br />

– kan aflæses fra SC)<br />

Beskrivelse<br />

off Fra off kan skiftes til starting up<br />

Slutrapport EFP05_33031_0011<br />

fatal Fatal bruges hvis der er sket en fejl der er så alvorlig at der ikke<br />

kan startes igen (hvis SC <strong>for</strong>søger vil FCC alligevel blive i off).<br />

starting up skifter selv til running (efter et stykke tid, når normal drift opnås)<br />

running Fra running kan skiftes til off. FCC går her igennem shutting<br />

down, <strong>og</strong> går herefter til off (dette kan tage variabel tid, <strong>og</strong> ske<br />

næsten øjeblikkeligt, eller der kan gå flere sekunder)<br />

shutting down Se running<br />

Idle Hvis sætpunktet til FCC (ønsket strøm/effekt) er lavt, kan FCC<br />

skifte fra starting up eller running til idle. Hvis sætpunktet øges<br />

vil FCC selv skifte til running (evt. via starting up).<br />

Efterfølgende er udvikling af de respektive 2 styringer beskrevet.<br />

4.7.1 FCC – Fuel Cell Controller<br />

IRD har i projektet udviklet 1. generations microcontroller. Prototypen viste sig at være en energibesparende<br />

<strong>og</strong> kompakt plat<strong>for</strong>m til at styre <strong>og</strong> overvåge en <strong>DMFC</strong>-brændselscelle stak samt de nødvendige<br />

hjælpekomponenter (BoP=Balance of Plant). Under projektet blev både hardware <strong>og</strong> software udviklet <strong>og</strong><br />

modnet. De egenskaber controlleren manglede blev undervejs tilføjet på prototype-print, da der ikke var<br />

nok tid til at udvikle et nyt board. Til den endelige FCC styring er der valgt software baseret på eCos<br />

(embedded Configuration operation system) der er et ”open source”, ”royalty-free” ”real-time”operations<br />

system. Denne plat<strong>for</strong>m er afprøvet med succes. Softwaren nåede et stadie hvor styringen på en stabil<br />

<strong>og</strong> gentagelig måde kunne starte <strong>modul</strong>et, samt holde <strong>modul</strong>et kørende i længere tid, så længe Metanol<strong>for</strong>syningen<br />

ikke slap op. Styringen tager ligeledes højde <strong>for</strong> de fejlsituationer der kan opstå <strong>og</strong> lukker<br />

<strong>modul</strong>et ned, hvis en situation der truer stakkens helbred opstår.<br />

Der er ialt 6 driftstilstande <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et, der kan opdeles i to kategorier: On <strong>og</strong> Off. Set ”udefra” –<br />

altså <strong>for</strong> at styre FCC – er det nok at arbejde med kun de to kategorier: On <strong>og</strong> Off.<br />

De tre tilstande: “starting up”, “running” <strong>og</strong> “idle” er alle at regne <strong>for</strong> “normale driftstilstande”. Fælles <strong>for</strong><br />

“starting up” <strong>og</strong> “idle” er at i disse to tilstande leverer FCC ikke den ønskede effekt, men vil <strong>for</strong>søge at<br />

levere det ønskede – <strong>og</strong> når dette sker (inden <strong>for</strong> en tolerance) skiftes automatisk til “running”. SC kan<br />

altså behandle disse tilstande som én (svarende til kategorien ”On”).<br />

Følgende brændselscelle driftsparametre kan læses fra FCC af SC:<br />

- Kategori <strong>og</strong> tilstand <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong> (jvf. tabel 8)<br />

- Samlet driftstid <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et<br />

- Stak spænding<br />

- Minimum cellespænding<br />

- Stakstrøm<br />

- Stak driftstemperatur<br />

- Total kWh<br />

- Vandniveau <strong>intern</strong>t i <strong>DMFC</strong> <strong>modul</strong>et<br />

Ud over disse <strong>intern</strong>e FCC tilstande, er der visse alarmer/fejltilstande, der kan læses fra FCC af SC. Indtræffer<br />

der en fejltilstand, vil FCC så vidt muligt <strong>for</strong>søge at imødegå denne, f.eks. vil en <strong>for</strong> høj temperatur<br />

medføre at FCC skifter til “idle”. Fejltilstande der kan læses:<br />

- Høj staktemperatur<br />

- Lav cellespænding<br />

- Start op tid overskredet<br />

- Lav vandniveau <strong>intern</strong> i <strong>DMFC</strong> <strong>modul</strong><br />

Side 12 / 26


Slutrapport EFP05_33031_0011<br />

I projektet er der arbejdet med udvikling af et nyt CVMS (Cell Voltage Monitoring System) måleprincip<br />

Nuværende CVMS praksis er at bruge <strong>modul</strong>er der er elektrisk isolerede. Man kan derved benytte flere<br />

<strong>modul</strong>er <strong>for</strong> at opnå det ønskede antal måle-kanaler. Hvis antallet af kanaler begrænses til f.eks. 60 kanaler<br />

kan den elektriske isolering undværes, hvorved størrelse <strong>og</strong> pris kan reduceres. Der er i projektet<br />

opbygget et print til test af det nye måleprincip. Testen af selve måleprincippet er afprøvet med succes.<br />

Før det nye måleprincip implementeres i brændselsceller skal der i kombination med dette udvikles et<br />

mekanisk kontakteringsprincip til de enkelte celler i brændselscelle stakken. Til integration med prototype<br />

<strong>DMFC</strong> <strong>modul</strong>et, er der der<strong>for</strong> anvendt et tidligere udviklet <strong>og</strong> vel afprøvet CVMS <strong>modul</strong>.<br />

4.7.2 SC - System Controller<br />

H2 L<strong>og</strong>ic har udviklet System controller (SC) som en del af dette projekt. Målsætningen <strong>for</strong> udviklingen<br />

var at lave en generisk styring der kunne håndtere en række <strong>for</strong>skellige inputs/outputs så der ikke ville<br />

blive n<strong>og</strong>le begrænsninger i projektet hvad angår styringer.<br />

System control kan opdeles i 3 delsystemer:<br />

• System Control Board<br />

• System Control Datal<strong>og</strong>ger<br />

• System Control Display<br />

Sammenhængen mellem de 3 delsystemer er vist i blokdiagrammet over System Control vist i Bilag 3.<br />

System control Board<br />

SC er opbygget af 3 PCB (Printed Circuit Board). 1 board med processor <strong>og</strong> integrerede switchmode<br />

strøm<strong>for</strong>syninger, 1 board med alle inputs 1 board til alle outputs. De 3 boards er samlet i en kompakt<br />

styring som vist på billede 9. Blok diagram der viser funktionen af System Control Board er vedlagt i Bilag<br />

4.<br />

Billede 9 – System Control Board installeret på køretøjet<br />

SC måler <strong>og</strong> behandle data fra følgende:<br />

- Strøm <strong>og</strong> spænding fra brændselscellestakken <strong>og</strong> batterier<br />

- Strømmen til <strong>og</strong> fra motoren. (Måling af regenereret energi)<br />

- Metanol niveau i tanken.<br />

Side 13 / 26


- Vand niveau i vand-beholderen.<br />

- Temperaturer i <strong>og</strong> omkring DC/DC, batterier.<br />

Slutrapport EFP05_33031_0011<br />

Til måling af metanol niveau i metanoltanken <strong>og</strong> vandbeholderen er der konstrueret et kredsløb med en<br />

tryk sensor fra Sensor Technics. Princippet er at bruge trykmålingen til at beregne metanolmængden i<br />

tankene. Målingen midles over en periode hvor<strong>for</strong> rystelser på køretøjet ikke giver anledning til unøjagtige<br />

målinger.<br />

SC er opbygget omkring en kraftig ARM-7 processor. Der bruges anal<strong>og</strong>e kredsløb til spændingsmåling <strong>og</strong><br />

strømmålinger er baseret på Hall effekt princippet. Der er indbygget CAN <strong>og</strong> RS485/RS232 kommunikation.<br />

System Control Datal<strong>og</strong>ger<br />

Datal<strong>og</strong>ning er yderst essentielt i et udviklingsprojekt, da valide driftsdata skal bruges til erfaringsindsamling<br />

<strong>og</strong> anbefaling af videre udvikling. Der blev således i staten af projektet udviklet en kompakt datal<strong>og</strong>ger<br />

som bl.a. blev anvendt til dataindsamling på en eksisterende el-scooter.<br />

Data l<strong>og</strong>ges på et SD-kort, hvor der kan gemmes op til 4Gbyte data hvilket er rigeligt til måneders dataindsamling.<br />

Anvendelsen af SD-kort muliggør simpel adgangs til dataene i en service situation eller lignende.<br />

Datal<strong>og</strong>geren kommunikerer<br />

med System Control Board via<br />

CAN 2.0. System Control Datal<strong>og</strong>ger<br />

har følgende specifikationer:<br />

- Canbus kommunikation<br />

CAN 2.0 100kBit 11bit Id.<br />

- Power input 18-33VDC<br />

- Signal diode <strong>for</strong> Power<br />

- Signal diode <strong>for</strong> Can kommunikation<br />

- Signal diode <strong>for</strong> fejl<br />

- Signal <strong>for</strong> l<strong>og</strong>ning af data.<br />

Datal<strong>og</strong>geren har vist sig nyttig i<br />

andre applikationer, <strong>og</strong> er således<br />

<strong>og</strong>så blevet afprøver i H2 L<strong>og</strong>ic’s<br />

H2 Trucks <strong>og</strong> datal<strong>og</strong>ning på gaffeltrucks<br />

i CanDan projektet. Datal<strong>og</strong>geren<br />

kan ses på billede 10.<br />

I prototypekøretøjet er der videreudviklet<br />

på datal<strong>og</strong>geren, <strong>og</strong> denne<br />

er således integreret i System<br />

Control Display.<br />

Billede 10 - Datal<strong>og</strong>ger<br />

System Control Display<br />

Til at vise <strong>og</strong> illustrere <strong>DMFC</strong> systemets tilstand <strong>og</strong> in<strong>for</strong>mere brugeren med nyttige in<strong>for</strong>mationer, er der<br />

udviklet et System Control Display til prototype køretøjet. I et kommercielt system skal dataene integreres<br />

i det nuværende display/brugerpanel, hvor batterispændingen i dag vises. Den oprindelige tanke var<br />

at bruge det oprindelige display, men efterhånden som projektet skred frem blev det klart at det ville<br />

være nødvendigt med et display hvor der kunne vises flere data end i Mini Crosserens nuværende display.<br />

System Control Displayet funktion vil således i prototypekøretøjet blandt andet være:<br />

- Status <strong>for</strong> <strong>DMFC</strong> system<br />

- Mulig fejlmelding fra <strong>DMFC</strong> system<br />

- Visning af Metanol mængde i tanken.<br />

- Visning af vand mængde i vand-beholder<br />

- Visning af strøm, spænding <strong>og</strong> effekt fra Stak, DC/DC <strong>og</strong> køretøj.<br />

- Mulighed <strong>for</strong> opgradering med teknisk service menu.<br />

Displayet kommunikerer med SC via. CAN bussen. På billede 11 ses layout af bruger-interfacet på System<br />

Control Display.<br />

Side 14 / 26


z<br />

Slutrapport EFP05_33031_0011<br />

Bruger interfacet er udviklet specifikt til prototypekøretøjet <strong>og</strong> er ikke tænkt anvendt i et kommercielt<br />

køretøjet, da de nødvendige data skal kommunikeres direkte fra brugerpanelet integreret i køretøjets<br />

styr. På displayet kan systemets status ses, <strong>og</strong> eventuelle fejlmeddelelser vises ligeledes. Strøm, spænding<br />

<strong>og</strong> effekt vises fra stakken, DC/DC konverter <strong>og</strong> <strong>for</strong>brug på køretøjet. Dette vil i en afprøvningsfase<br />

give en god <strong>for</strong>nemmelse <strong>for</strong><br />

testkøreren hvordan <strong>DMFC</strong> systemet<br />

<strong>og</strong> køretøjet vil reagere i<br />

<strong>for</strong>hold til hinanden. Endelig vises<br />

det hvor meget metanol der<br />

er i tanken, <strong>og</strong> hvor meget vand<br />

der er i vandbeholderen. Det er<br />

ligeledes <strong>og</strong>så muligt at kunne<br />

tømme vandbeholderen ved at<br />

trykke på ”Drain” knappen.<br />

Installationen af displayet kan<br />

ses på billede 12.<br />

Ved en senere integration på et<br />

kommercielt køretøj vil det <strong>for</strong>ventelig<br />

udelukkende være tank<br />

niveau i metanoltanken der vil<br />

vises konstant i displayet, <strong>og</strong><br />

muligvis <strong>og</strong>så standen i vandbeholderen,<br />

alt efter hvordan denne<br />

integration laves i et kom-<br />

Billede 11 – System Control Display layout.<br />

Billede 12 – Installation af display på prototypekøretøjet.<br />

Side 15 / 26


mercielt køretøj.<br />

4.8 - WP8 Konstruktion af effektelektronik<br />

Power elektronikken til køretøj er udviklet <strong>og</strong> konstrueret af H2 L<strong>og</strong>ic.<br />

Slutrapport EFP05_33031_0011<br />

4.8.1. Dimensionering af Power elektronik<br />

Som første led blev der lavet datal<strong>og</strong>ning på et traditionelt Mini Crosser T140 køretøj som Mini Crosser<br />

anvender i deres produktionsafdeling. Datal<strong>og</strong>ningen viser at effekt<strong>for</strong>bruget i stor grad sker i peaks,<br />

hvilket <strong>for</strong>ventelig er en af <strong>for</strong>klaringerne på at batterilevetiden på Mini Crosserne er så relativt korte.<br />

På graf 13 ses strømtrækket over 4 timers drift. Der er efterfølgende lavet datal<strong>og</strong>ninger på køretøjer der<br />

kører udendørs, <strong>og</strong> <strong>for</strong>brugsmønsteret er her væsentlig anderledes da <strong>for</strong>bruget stabilt ligger på ca.<br />

500W ved kørsel på lige vej.<br />

3000<br />

2500<br />

2000<br />

1500<br />

1000<br />

500<br />

0<br />

-500<br />

-1000<br />

06:30:24<br />

06:36:54<br />

06:43:24<br />

06:49:54<br />

06:56:24<br />

07:02:59<br />

07:09:29<br />

07:15:58<br />

07:22:28<br />

07:28:58<br />

07:35:28<br />

07:41:59<br />

07:48:28<br />

07:54:58<br />

08:01:28<br />

08:07:58<br />

08:14:28<br />

08:20:58<br />

08:27:28<br />

08:33:58<br />

Effekt (W)<br />

08:40:28<br />

08:46:57<br />

08:53:33<br />

09:00:02<br />

09:06:32<br />

09:13:02<br />

09:19:32<br />

09:26:02<br />

Graf 13 – Datal<strong>og</strong>ning af kørsel med Mini Crosser.<br />

Forudsætningen <strong>for</strong> dimensioneringen af power elektronikken, batterierne <strong>og</strong> <strong>DMFC</strong> <strong>modul</strong>et var at køretøjet<br />

skulle kunne køre op ad bakke i 20minutter, hvor batteriet i de første 5 minutter leverede alt energi,<br />

<strong>og</strong> <strong>DMFC</strong> <strong>modul</strong>et i de sidste 15min leverede 500W. Dette gav en minimum størrelse på batteriet på<br />

12Ah <strong>og</strong> det betød samtidig at stakken udelukkende skulle levere effekt til nominel drift på 500W, <strong>og</strong><br />

dermed var kravspecifikationen til DC/DC konverteren <strong>og</strong>så minimum 500W. Beregningerne <strong>for</strong> driftstid<br />

er nærmere specificeret i bilag 1 – Kravspecifikation.<br />

4.8.2. DC/DC konverter<br />

Der er igennem projektet blevet testet flere <strong>for</strong>skellige DC/DC konverter konfigurationer. Ud fra kravspecifikationen<br />

blev der indkøbt flere DC/DC kerne<strong>modul</strong>er som H2 L<strong>og</strong>ic så udviklede videre på. Lave<br />

rippel strømme, kompakt design <strong>og</strong> minimum af strømtræk på staksiden ved start-up blev vurderet som<br />

de væsentligste kriterier <strong>for</strong> udviklingen.<br />

Igennem udviklingen blev det d<strong>og</strong> klart, at <strong>for</strong> at kunne lave en blød opstart af <strong>DMFC</strong> <strong>modul</strong>et skulle der<br />

trækkes en meget præcis strøm fra stakken. Dette krævede igen en præcis styring af DC/DC konverteren.<br />

Normalt er en DC/DC konverter reguleret på udgangen, men da udgangen er direkte <strong>for</strong>bundet med<br />

batteriet viste det sig at det blev tæt på umuligt at regulere strømtrækket på indgangen hurtigt <strong>og</strong> præcist<br />

nok. Det oprindelige valg af DC/DC konverter blev således erstattet af en DC/DC konverter der var<br />

strømstyret på indgangen. Den nye DC/DC konverter fungerede efter hensigten <strong>og</strong> blev valgt til integration<br />

på prototypekøretøjet.<br />

09:32:32<br />

09:39:02<br />

09:45:32<br />

09:52:02<br />

09:58:32<br />

10:05:02<br />

10:11:32<br />

10:18:07<br />

10:24:37<br />

10:31:07<br />

10:37:42<br />

10:44:12<br />

Side 16 / 26


Slutrapport EFP05_33031_0011<br />

4.8.3. Valg af batterier<br />

Der blev testet en række batterier i projektet ud fra de primære <strong>for</strong>udsætninger om at der skulle kunne<br />

trækkes 45A i op til 5 minutter, <strong>og</strong> den reelle ledige kapacitet på batterierne EOL skulle være minimum<br />

12Ah. Følgende batterier blev testet:<br />

AGM. 24V/14Ah.<br />

Fordel - Høj strøm tæthed, stor kortslutnings strøm, vedligeholdelsesfrit.<br />

Udvidet temperatur-40°C til 50°C.<br />

Ulemper - Størrelse <strong>og</strong> vægt.<br />

Konklusion: Kapaciteten EOL vil være <strong>for</strong> begrænset.<br />

NiMH. 24V/18Ah (Sammensat pakke 2*10 celler.)<br />

Fordel - Høj strøm tæthed, stor kortslutnings strøm, 3.5m ohm, vedligeholdelsesfrit.<br />

Alm. Temperatur område. 0°C til 45°C<br />

Minimal størrelse i <strong>for</strong>hold til Bly <strong>og</strong> AGM batterier.<br />

Ulemper - Klat ladning er ikke optimal.<br />

Konklusion: Vi så allerede under test at batteriet mistede kapacitet grundet klat- ladningen <strong>og</strong> <strong>for</strong>brug.<br />

Lithium Ion. 25,2V/12,8Ah - 152A Peak 6 sek. (Sammensat pakke af 7*8 celler.)<br />

Fordel - Høj strøm tæthed, stor kortslutnings strøm, 3.0m ohm, vedligeholdelsesfrit.<br />

Kan klat lades. (Ved korrekt ladning lang levetid)<br />

Minimal størrelse i <strong>for</strong>hold til Bly <strong>og</strong> AGM batterier.<br />

Ulemper - Mange celler <strong>for</strong> at opnå den ønskede kabacitet.<br />

Konklusion: En række leverandører blev spurgt, men det viste sig ganske svært at få leveret et ønsket<br />

batteri. Tæt ved projektets slutning blev det endelig muligt at købe et Li-ion batteri, men C-værdien var<br />

<strong>for</strong> lav til at batteriet vil kunne bruges i prototypekøretøjet. Desuden var leverandørerne ikke i stand at<br />

levere den <strong>for</strong>nødne dokumentation på batterierne.<br />

Ud fra testene blev det valgt at bruge en Gel batteri med lidt større kapacitet end AGM batteriet. Der blev<br />

der<strong>for</strong> valgt 2 stk 12V/20Ah batterier fra Panasonic. Disse er integreret i prototypekøretøjet.<br />

4.9 - WP9 System integration<br />

System integrationen har i praksis været opdelt mellem System integration af <strong>DMFC</strong> Generator/<strong>modul</strong><br />

hos IRD <strong>og</strong> System integration af det komplette system hos H2 L<strong>og</strong>ic.<br />

4.9.1 <strong>DMFC</strong> Generator<br />

Muligheden <strong>for</strong> at integrere <strong>modul</strong> komponenterne<br />

i batteribakken på MiniCrosser køretøjet er blevet<br />

undersøgt i det indledende arbejde med projektet<br />

se asnit 4.9.3.<br />

Da det er det IRD´s første <strong>DMFC</strong> <strong>modul</strong> i denne<br />

størrelse, blev det vedtaget at fremstille et <strong>modul</strong><br />

der med størst sandsynlighed ville give gode resultater<br />

til projektet. Der<strong>for</strong> er alle BOP komponenter<br />

placeret så de sidder optimalt i <strong>for</strong>hold til brændselscellen,<br />

<strong>og</strong> ikke så de passer optimalt ind i køretøjet.<br />

Køleren som er indkøbt til projektet vil ligeledes<br />

ikke kunne placeres i batteribakken (WP5).<br />

Prototypen er der<strong>for</strong> konstrueret til i testperioden<br />

at skulle placeres opretstående på ladet af køretøjet<br />

(Figur 14).<br />

<strong>DMFC</strong> <strong>modul</strong>et har to grænseflader:<br />

• Mekanisk grænseflade <strong>for</strong> gas/væske ind/ud<br />

• Elektrisk grænseflade <strong>for</strong> elektrisk I/O <strong>og</strong> kommunikation<br />

Figur 14 – <strong>DMFC</strong> <strong>modul</strong> til integration på Mini Crosser<br />

Side 17 / 26


Slutrapport EFP05_33031_0011<br />

<strong>DMFC</strong> <strong>modul</strong>et skal <strong>for</strong>synes med 24 VDC fra batteriet, metanol fra ekstern tank samt luft ved indsug gennem<br />

kabinettet. Modulet udleder overskuds luft, kuldioxid, vand <strong>og</strong> varme. Figur 15 viser henholdvis<br />

elektrisk <strong>og</strong> mekanisk grænseflade skematisk.<br />

Elektriske grænseflader Mekaniske grænseflader<br />

Figur 15 – elektriske <strong>og</strong> mekaniske grænseflader<br />

<strong>DMFC</strong> <strong>modul</strong>et har i alt under test, idriftsættelse <strong>og</strong> integration på IRD kørt i 100 timer.<br />

I figur 16, er vist et eksempel på karakteristikken <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et. Målingerne blev udført med en laboratorie<strong>for</strong>syning<br />

som leverede 24 VDC til enheden <strong>og</strong> ved brug af en elektronisk belastning til at simulerer<br />

en ekstern belastning (konstant ladestrøm på 45A).<br />

Figur 16 – Eksempel på karakteristik <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et<br />

Side 18 / 26


Slutrapport EFP05_33031_0011<br />

I tabel 17 er specifikation <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et vist <strong>og</strong> i tabel 18 er de i projektet opnåede data <strong>for</strong> <strong>DMFC</strong><br />

<strong>modul</strong>et vist.<br />

<strong>DMFC</strong>600W Power Generator Specification.<br />

Stack Power Rated 630 W<br />

Voltage @ nominal B-o-L 14 V<br />

Stack Current nominal 45 A<br />

Stack Current range 18-50 A<br />

Start-up time(to achieve rated power) > 10 minutes<br />

Operating stack temperature nominal 70-75 °C<br />

Ambient temperature range @ operation -15 to 35 °C<br />

Ambient temperature range @ storage > 0 °C<br />

Fuel.<br />

Type/Purity<br />

Max. fuel pressure<br />

Air consumption rate @ nominal ( =1) 1.57 m 3 /h<br />

Air pressure Ambient<br />

Methanol consumption rate @ nominal 0.68 L/kWh<br />

Emissions:<br />

Maximum liquid water @ rated power<br />

CO2 @ rated power<br />

Heat, PW [HHV] @ nominal<br />

Power required @ Idle state<br />

Power required @ Start-up<br />

Methanol puriss.<br />

meets analytical specification of Ph Eur, ≥99.7%(GC)<br />

0.05 bar (g)<br />

0.2 L/kWh<br />

0.26 kg/kWh<br />

1335 W<br />

8.3 W<br />

64 W<br />

Allowable range of DC power supply 18-28 V<br />

Tabel 17 - <strong>DMFC</strong> Modul specifikation.<br />

<strong>DMFC</strong>600W Power Generator Results.<br />

Stack Power @ nominal 680 W<br />

Efficientyel<br />

35 %<br />

BoP Power Consumption @ nominal 64 W<br />

Fuel efficiency 85 %<br />

System efficiencyel<br />

Tabel 18 - Opnåede systemeffektivitet.<br />

26 %<br />

4.9.2 System integration<br />

H2 L<strong>og</strong>ic afventede opstart af system integration indtil IRD leverede <strong>DMFC</strong> generatoren/<strong>modul</strong>et da H2<br />

L<strong>og</strong>ic så ville integrere det samlede system. Et af de oprindelige ønsker var at integrere det samlede system<br />

under batterikassen på køretøjet. Det viste sig d<strong>og</strong> i løbet af projektet, at der ville være behov <strong>for</strong><br />

yderligere udvikling <strong>for</strong> at gøre komponenterne kompakte nok til integration under batterikassen.<br />

Efter modtagelse af <strong>DMFC</strong> generatoren blev det besluttet at tage sædet af køretøjet <strong>og</strong> erstatte dette<br />

med et mindre ”ståsæde” hvorefter <strong>DMFC</strong> generatoren blev monteret på et lad bag på køretøjet.<br />

Det blev efterfølgende besluttet at integrere batterier, power elektronik, styring, metanoltank m.v. i en<br />

kasse der kan stå under batterikassen. System kassen kan ses på billede 19.<br />

Side 19 / 26


Slutrapport EFP05_33031_0011<br />

Vandbeholderen til overskudsvand blev installeret under køretøjet med en magnetventil der åbnes når<br />

brugeren ønsker at tømme tanken. Der er i såvel metanoltanken <strong>og</strong> vandbeholderen anvendt en RVQ050<br />

tryktransducer til at måle mængden i tanken.<br />

Den samlede system integration på Mini Crosseren kan ses på billede 20.<br />

DC/DC<br />

Metanoltank<br />

Batterier<br />

System Control (SC)<br />

Billede 19 - System integration af System kassen<br />

Billede 20 – Samlet system integration på køretøjet<br />

Side 20 / 26


Slutrapport EFP05_33031_0011<br />

4.9.3. Fremtidig integration<br />

Grundet projektets ønske om at integrere hele <strong>DMFC</strong> systemet i batterikassen har der i projektet været<br />

arbejdet på at dokumentere hvorvidt det er muligt at integrere de nuværende komponenter i batterikassen,<br />

såfremt de videreudvikles <strong>og</strong> bygges kompakt sammen. IRD har laver modellering som vist på billede<br />

21, hvor det ses at det er muligt at integrere alle komponenter med undtagelse af batterier, effekt<br />

elektronik, køler <strong>og</strong> metanoltank. De øvrige komponenter vil der være plads til at integrere på en Mini<br />

Crosser kabinemodel som vist på billede 22.<br />

Billede 21 – Fremtidig integration i batteribakken på Mini Crosser T140<br />

4.10 Test, dokumentation <strong>og</strong> rapportering<br />

Denne rapport kan ses som resultatet fra WP10.<br />

Projektets <strong>for</strong>løb <strong>og</strong> resultat er dokumenteret, <strong>og</strong> <strong>DMFC</strong> systemet er succesfuld integreret <strong>og</strong> demonstreret<br />

i funktion på Mini Crosseren. Det har desværre ikke været muligt inden<strong>for</strong> projektet at lave de ønskede<br />

tests på det samlede køretøj hos en slutbruger, da det blev nødvendigt at ombygge køretøjet <strong>for</strong> at<br />

gøre plads til <strong>DMFC</strong> generatoren. Der vil efter projektets afslutning blive lavet <strong>for</strong>tsatte afprøvninger hos<br />

IRD, Mini Crosser <strong>og</strong> H2 L<strong>og</strong>ic hvor driftsdata indsamles <strong>og</strong> anvendes i projektet ”<strong>DMFC</strong> Stack <strong>og</strong> MEA<br />

udvikling” samt i efterfølgende projekter til dette projekt.<br />

5. Kommercialisering af <strong>DMFC</strong> teknol<strong>og</strong>i i en Mini Crosser<br />

For at kunne kommercialisere <strong>DMFC</strong> teknol<strong>og</strong>i i en Mini Crosser er det nødvendig at vurdere på 3 aspekter:<br />

Pris, Levetid <strong>og</strong> evt. værdi<strong>for</strong>øgelse. Det er disse 3 aspekter der samlet set giver en værdi hos brugeren<br />

af en Mini Crosser.<br />

Det er svært <strong>for</strong> Mini Crosser at vurdere en eksakt levetid på køretøjet, hvor<strong>for</strong> der bruges en gennemsnitslevetid<br />

på 10år/5000timer i de efterfølgende beregninger. I det efterfølgende bruges Mini Crossers<br />

indkøbspris af batterier <strong>og</strong> brændselscelleteknol<strong>og</strong>i som sammenligningsgrundlag, da indkøbspriser skal<br />

holdes op mod IRD/H2 L<strong>og</strong>ic salgspris til Mini Crosser i et kommercielt marked.<br />

Konventionel batteriteknol<strong>og</strong>i<br />

Der anvendes i dag konventionel bly-batteri teknol<strong>og</strong>i i <strong>for</strong>m af Gel-batterier.<br />

Batterierne kan fås op til 110Ah,24V størrelse. Ved maks. 80% afladning giver det en kapacitet på<br />

2,1kWh energimængde i den nuværende batteriløsning.<br />

Side 21 / 26


Slutrapport EFP05_33031_0011<br />

Mini Crosser indkøbspris <strong>for</strong> 2 stk. 12V, 110Ah batteri til 1000kr/stk. Levetiden <strong>for</strong> et batteri i en Mini<br />

Crosser er typisk 1000 driftstimer eller 2 år. De 1000 timer svarer ikke til mere end 200-400cycles på<br />

batteriet, hvor<strong>for</strong> det må konkluderes at batterierne bliver kørt meget hårdt i køretøjet. Ved god vedligehold<br />

af et Gel batteri burde levetider på 800-1000 cycles være muligt.<br />

Mini Crosser indkøbsprisen <strong>for</strong> nuværende batteriløsning er således 909kr/kWh.<br />

Ved 10 års levetid skal der bruges 10 batterier hvilket giver en omkostning på 10.000kr.<br />

Li-ion batterier<br />

Den værste konkurrent til <strong>DMFC</strong>-teknol<strong>og</strong>i <strong>for</strong>ventes at være en <strong>for</strong>bedret batteri-teknol<strong>og</strong>i, hvor Li-ion<br />

<strong>og</strong> på sigt Li-jern batterier har vist lovende resultater. Fordelen ved Li-ion batterier er en højere energitæthed<br />

på 90-120Wh/kg, mens energitætheden i bly gel batterier ligger på 50Wh/kg. I den samme batterikasse<br />

volumen kan der således lagres dobbelt så meget energi i et Li-ion batteri som i et bly-batteri.<br />

Prisen på Li-ion batterier ligger i dag på 10.000kr/kWh (2.000 UDS/kWh) ved køb af 1 stk, men prisen på<br />

Li-jern batterier <strong>for</strong>ventes i løbet af 2-3 år at nå ned på 1500kr/kWh (300 UDS/kWh).<br />

Li-jern batterier vil ligeledes kunne klare høje lade-<br />

<strong>og</strong> afladningsstrømme, <strong>og</strong> et batteri <strong>for</strong>ventes at have<br />

en levetid på 1500 fylde cycles inden EOL. Dette<br />

vil i praksis betyde at et batteri kan bruges i hele<br />

køretøjets levetid. Der er d<strong>og</strong> usikkerheder i <strong>for</strong>hold<br />

til hvor hårdt batteriet vil blive kørt hvor<strong>for</strong> det konservativt<br />

er valgt at der skal bruges 2 batterier i køretøjets<br />

levetid. Den samlede omkostning ved Li-ion<br />

batterier i dag (1-stk pris) vil således være<br />

52.800kr. Prisen om 2-3år <strong>for</strong>ventes at være<br />

7.920kr.<br />

Added value<br />

En mulighed <strong>for</strong> at <strong>DMFC</strong> teknol<strong>og</strong>i kan kommercialiseres<br />

i en Mini Crosser er helt klart at se på den added<br />

value der kan indbygges på køretøjet. Spildvarmen<br />

fra <strong>DMFC</strong> stakken kan relativt enkelt bruges til<br />

opvarmning af køretøjet. Mini Crosser har udviklet et<br />

køretøj med kabine baseret på T130 plat<strong>for</strong>men (Se<br />

billede 22). Her tilkøber flere slutbrugere et lille dieselfyr<br />

der kan opvarme køretøjet. Mini Crossers<br />

købspris ligger på 6.000kr <strong>for</strong> dieselfyret, <strong>og</strong> såfremt<br />

<strong>DMFC</strong> systemet kan producere varme til kørtetøjet,<br />

kan denne omkostning undlades, <strong>og</strong> targetprisen kan<br />

<strong>for</strong>højes med 6.000kr.<br />

Billede 22 – Mini Crosser kabinemodel<br />

<strong>DMFC</strong> system<br />

Såfremt det samlede <strong>DMFC</strong> system kan leve i 10år <strong>og</strong> 5000timer, som det er målsætningen, så skal der<br />

ikke beregnes med udskiftning af <strong>DMFC</strong> systemet i køretøjets levetid. Target price kan således beregnes<br />

på <strong>for</strong>skellige måder, alt efter hvilke <strong>for</strong>udsætninger der anvendes.<br />

Scenarier/Forudsætninger Target price<br />

Sammenlignet med fremtidige Li-ion batterier (kapacitet <strong>for</strong>dobles) 15.840kr<br />

Sammenlignet med nuværende Li-ion teknol<strong>og</strong>i (kapacitet <strong>for</strong>bobles) 105.600kr<br />

Sammenlignet med nuværende batteri-løsning (samme kapacitet) 10.000kr<br />

Sammenlignet med nuværende batteri løsning + kabinevarme 16.000kr<br />

Sammenlignet med fremtidig Li-ion batterier (dobbelt kap) + kabinevarme 21.840kr<br />

I ovenstående simplificerede target price beregninger er der ikke taget <strong>for</strong>udsætning <strong>for</strong> ændringer i kapitale<br />

omkostninger ved indkøb af et køretøj. Ved det afsluttende projektmøde gav Mini Crosser d<strong>og</strong> sin<br />

bekymring til kende i <strong>for</strong>hold til <strong>for</strong>øgelse af kapitalomkostningen ved køb. Det var Mini Crossers erfaring<br />

at brugerne lidt nemmere vil kunne acceptere en højere service pris end købspris. En mulighed <strong>for</strong> at<br />

komme ud over denne ud<strong>for</strong>dring vil d<strong>og</strong> være at tænke en leasing løsning, hvorved omkostningen <strong>for</strong><br />

energiløsningen <strong>for</strong>deles over eks. 5år. Mini Crosser til tage <strong>for</strong>slaget <strong>for</strong> leasing med i deres fremtidige<br />

overvejelser.<br />

Side 22 / 26


Slutrapport EFP05_33031_0011<br />

Driftsomkostninger<br />

For at kunne beregne total cost of ownership (TCO) må såvel anvendelse af el til batteriladning <strong>og</strong> anvendelse<br />

af metanol som brændstof i en <strong>DMFC</strong> stak beregnes.<br />

Elektricitet - batteri<br />

110 Ah * 24 V * 0,7 maksimal afladningsdybde = 1,848 kWh til rådighed. 1,848 kWh / 480 W v. 15 km/t<br />

på lige vej = 3 t 51 minutter. 5.000 t / 3 t 51 min. = 1.299 opladninger. Der regnes med en pris på 1,8<br />

kr./kWh. Det <strong>for</strong>ventes et tab på 35% fra lader-batteri-motor, så det samlede strøm<strong>for</strong>brug pr opladning<br />

beløber sig dermed til 2,494 kWh pr. opladning * 1.299 opladninger * 1,8 kr. /kWh = 5.831 kr.<br />

Metanol – <strong>DMFC</strong> system<br />

Der regnes med en systemvirkningsgrad ud af brændselscellesystemet på 30 %. 5.000 t * 0,480 kW/t /<br />

0,3 = 8.000 kWh. Der regnes med et energiindhold på 4,44 kWh/l <strong>og</strong> med en pris på 7,71 kr./l metanol.<br />

Der skal således anvendes 8.000 kWh / 4,44 kWh/l = 1.802 l metanol svarende til 13.892 kr.<br />

Med <strong>for</strong>behold <strong>for</strong> en række tilnærmelser i ovenstående betragtninger på driftsøkonomi så må det konkluderes<br />

at driftsomkostningen <strong>for</strong> metanol vil være ca. dobbelt pris af prisen <strong>for</strong> elektricitet. Der er helt<br />

set bort fra serviceomkostninger i denne beregning, men grundet kompleksiteten i et <strong>DMFC</strong> system, må<br />

serviceomkostninger på <strong>DMFC</strong> systemet <strong>for</strong>ventes at være højere end i et batteri.<br />

Mini Crossers kommercielle vurdering<br />

Til projektafslutningsmødet blev Mini Crosser spurgt om deres vurdering af muligheden <strong>for</strong> kommercialisering<br />

af <strong>DMFC</strong> teknol<strong>og</strong>ien i en Mini Crosser. Mini Crosser var overbevist om at såfremt teknol<strong>og</strong>ien kan<br />

nå de kommercielle niveau, så vil en del af deres kunder ønske at bruge metanol som brændstof, <strong>og</strong><br />

dermed bevare friheden til at kunne køre væsentligt længere end tidligere.<br />

For at nå en fuld kommercielt marked i en standard Mini Crosser var vurderingen at target prisen skulle<br />

være 4.000kr, mens introduktionsprisen i en Mini Crosser med kabine kunne være 16.000kr, men skulle<br />

hurtigt falde til 10.000kr.<br />

Mini Crosser sælger i dag ca.250 Mini Crossers med kabine om året, <strong>og</strong> <strong>for</strong>venter at sælge 100-150 af et<br />

nyudviklet køretøj der er <strong>for</strong>stærket, så det kan klare brugere op til 250kg. Det samlede marked inden<strong>for</strong><br />

de nærmer år er således 400-500 køretøjet, <strong>og</strong> hvor stor en andel af disse der kan sælges med <strong>DMFC</strong><br />

teknol<strong>og</strong>i var meget svært <strong>for</strong> Mini Crosser at give en realistisk ide om.<br />

5.1. Target specifications <strong>for</strong> <strong>DMFC</strong> System til Mini Crosser<br />

De samlede target specifications <strong>for</strong> et <strong>DMFC</strong> System til en Mini Crosser er vurderet ud fra erstatning af<br />

eksisterende batteriteknol<strong>og</strong>i <strong>og</strong> ikke ud fra Li-ion fremtidige priser, da disse udelukkende er beregnet ud<br />

fra leverandørernes <strong>for</strong>ventninger til fremtiden. Følgende specifikationer blev opstillet til afslutningsmødet<br />

af Mini Crosser, IRD <strong>og</strong> H2 L<strong>og</strong>ic. Det anbefales at disse specifikationer bruges som basis from den videre<br />

udvikling.<br />

Specifikation Target<br />

Samlet <strong>DMFC</strong> system levetid >5000 timer<br />

Opstartstid til min 80% af nominel kapacitet 30 sek.<br />

Nominel effekt (ud af system ved EOL, 5000 timer) 500W<br />

Temperaturområde <strong>for</strong> opstart, drift <strong>og</strong> nedlukning -35°C – 40°C<br />

Target price<br />

- fuld kommerciel (alm. + kabine model)<br />

- marked udvidelse (kabine model)<br />

- marked intro (kabine model)<br />

4.000kr.<br />

10.000kr.<br />

16.000kr.<br />

Det er kravet at systemet kan installeres i en batteribakke på Mini Crosser T130, da det er denne plat<strong>for</strong>m<br />

der bruges i kabine udgaven.<br />

Fuld kommerciel target price er således 8.000kr/kW <strong>og</strong> markeds introduktionspris er 32.000kr/kW.<br />

5.2. Kommercialisering af <strong>DMFC</strong> teknol<strong>og</strong>ien som battery replacement<br />

Som en del af det ansøgte projekt skal det <strong>og</strong>så kort vurderes om <strong>DMFC</strong> teknol<strong>og</strong>ien vil kunne finde<br />

kommerciel anvendelse i andre applikationer end en Mini Crosser. Såfremt der kan findes flere parallelle<br />

markeder, vil markederne kunne supplere hinanden <strong>og</strong> producent af <strong>DMFC</strong> <strong>modul</strong>/system vil kunne nå<br />

den nødvendige kritiske volumen før teknol<strong>og</strong>ien kan kommercialiseres.<br />

Side 23 / 26


Slutrapport EFP05_33031_0011<br />

Markedsperspektiverne <strong>for</strong> <strong>DMFC</strong> teknol<strong>og</strong>ien som generator <strong>anlæg</strong> er ekstreme. Markedet <strong>for</strong> anvendelse<br />

af brændselsceller er traditionelt delt op i følgende områder.<br />

• Transportation<br />

• Stationary Power generation<br />

• Portable Power Generators<br />

• Micro Fuel Cells<br />

Generelt vil <strong>DMFC</strong> <strong>modul</strong>et kunne finde anvendelse i såvel stationær som mobil anvendelse.<br />

Det stationære området omfatter to store potentielle markedssegmenter: nødstrøms<strong>anlæg</strong> <strong>og</strong> kraftvarme<strong>anlæg</strong>.<br />

Nødstrøms<strong>anlæg</strong> er et milliard-marked.Udskiftning af <strong>anlæg</strong> baseret på batterier eller dieselgeneratorer-<br />

med brændselscellebaserede <strong>anlæg</strong> - er stærkt motiveret af muligheden <strong>for</strong> markant lavere<br />

omkostninger samt miljømæssig lovgivning på området. Der <strong>for</strong>eligger på sigt <strong>og</strong>så et potentiale <strong>for</strong><br />

<strong>DMFC</strong> <strong>modul</strong> anvendt i kraftvarme<strong>anlæg</strong> i det såkaldte ”område 4”, hvor der kan anvendes metanol som<br />

brændsel.<br />

Potentialet <strong>for</strong> mobil anvendelse her er meget stort <strong>og</strong> har et perfekt match med IRD’s effekt størrelse.<br />

Dette område dækker bredt en lang række applikationer som:<br />

• Drivkraft til <strong>intern</strong> <strong>transport</strong>: gaffeltrucks, handicapkøretøjer, scooters, marine etc.<br />

• Kraft-generatorer til brug i yderområder: <strong>mobile</strong> sendemaster, vejrstationer etc.<br />

• Mindre backup-systemer til IT, telefoni, hospitaler <strong>og</strong> missionskritiske systemer etc.<br />

• Kraftenheder (fx reservekraft) til containere, lastbiler, trafiksignaler til lands <strong>og</strong> til vands etc.<br />

6. Diskussion <strong>og</strong> konklusion<br />

Den væsentligste konklusion er at der succesfuldt er udviklet et <strong>DMFC</strong> system til en Mini Crosser <strong>og</strong> det<br />

er eftervise at <strong>DMFC</strong> systemet <strong>og</strong> Mini Crosseren kan fungerer sammen. Projektets mål er nået, men projekter<br />

er ikke kommet så langt som oprindeligt håbet i <strong>for</strong>hold til komplet integration på køretøjet.<br />

Det kan konkluderes at det vil være nødvendigt med yderligere en del arbejde før at <strong>DMFC</strong> teknol<strong>og</strong>ien<br />

kan kommercialiseres i en Mini Crosser eller til andre applikationer. Det er anskueliggjort i projektet at<br />

metanol vil kunne anvendes som brændstof til el-scootere, men <strong>og</strong>så at den fuld kommercielle target pris<br />

er 4.000kr. svarende til 8.000kr./kW. Med så lavt en target pris kan det konkluderes at Mini Crosser ikke<br />

alene vil kunne aftage tilstrækkeligt med systemet til at der kan opbygges produktion <strong>og</strong> der kan gives<br />

stordrifts<strong>for</strong>dele hvorved target priser nås.<br />

Det kan sluttelig sammenfattes at IRD <strong>og</strong> Mini Crosser ønsker at videreføres projektet, <strong>og</strong> vil ansøge<br />

EUDP efterårs call om videreførelse af projektet.<br />

7. Sammenligning af opnåede mål med projektets mål<br />

Projektets mål <strong>og</strong> ønsker er herunder holdt op om projektets realiserede mål <strong>og</strong> anbefaling til det videre<br />

<strong>for</strong>løb.<br />

Projektets mål:<br />

1) Udvikling af et fungerende <strong>DMFC</strong> <strong>modul</strong> der kan anvendes til <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> applikationer<br />

2) Integration af <strong>DMFC</strong> <strong>modul</strong> på et Mini Crosser køretøj<br />

3) Lave tests af det samlede <strong>DMFC</strong> system i laboratorium<br />

4) Dokumentere metanols anvendelse til el-scootere.<br />

Projektets ønsker:<br />

1) Lave integrationen i batteribakken på køretøjet<br />

2) Teste køretøjet hos slutbruger<br />

Helt overordnet kan det sammenfattes at projektets mål er opnået, Der er udviklet et <strong>DMFC</strong> system der<br />

er integreret på køretøjet. Der er ligeledes lavet tests på det samlede system i lab, <strong>og</strong> det er dokumenteret<br />

at metanol med stor sandsynlighed vil kunne anvendes til el-scootere.<br />

Side 24 / 26


Slutrapport EFP05_33031_0011<br />

Det kan desværre <strong>og</strong>så sammenfattes at projektets ønsker ikke har været mulige at nå inden<strong>for</strong> projektperioden.<br />

Integrationen er således ikke så kompakt som ønsket, <strong>og</strong> grundet integrationen har det ikke<br />

været muligt at lave tests hos slutbrugere.<br />

Budgettet på projektet blev beskåret inden projektet blev igangsat, hvilket i et mindre omfang kan retfærdiggøre<br />

at projektets ønsker ikke er opnået. IRD <strong>og</strong> Mini Crosser ønsker at <strong>for</strong>tsætte udviklingsarbejdet<br />

mens H2 L<strong>og</strong>ic ønsker at fokusere sine aktiviteter, hvilket i første omgang ikke inkluderer arbejde<br />

med <strong>DMFC</strong> teknol<strong>og</strong>i.<br />

8. Det videre <strong>for</strong>løb<br />

IRD <strong>og</strong> Mini Crosser er interesseret i at <strong>for</strong>tsætte udviklingsarbejdet, <strong>og</strong> ønsker direkte at videreføre dette<br />

projekts resultater i en EUDP ansøgning indsendt i efteråret 2008.<br />

Der er stadig en del udviklingsarbejde inden <strong>DMFC</strong> teknol<strong>og</strong>ien kan udrulles i en Mini Crosser, hvilket dette<br />

projekt <strong>og</strong>så har vist. Igennem projektet er der blevet identificeret en række arbejdsområder som der<br />

<strong>for</strong>tsat skal arbejdes videre på <strong>for</strong> at kunne kommercialisere <strong>DMFC</strong> teknol<strong>og</strong>ien til en Mini Crosser.<br />

1) <strong>DMFC</strong> Systemet skal gøres mere kompakt.<br />

2) Metanoltanken <strong>og</strong> køler kan evt. tænkes separeret fra <strong>DMFC</strong> systemet <strong>og</strong> installeres hvor der er<br />

yderligere plads på køretøjet.<br />

3) Systemet skal udvikles så det kan opstarte, køre <strong>og</strong> nedlukke i frostvejr. Det første kommercielle<br />

marked i Mini Crosseren er versionen med den lukkede kabine, <strong>og</strong> hovedparten af dette marked<br />

er i Norge, <strong>og</strong> <strong>DMFC</strong> systemet skal således <strong>for</strong>ventelig udruller i Norge først.<br />

4) System control <strong>og</strong> FC Control skal integreres til én enhed. Og display skal erstattes med integration<br />

med i Mini Crosserens eksisterende display.<br />

Der er <strong>for</strong>ventelig yderligere arbejdsområder der skal fokuseres på. Dette vil blive nærmere beskrevet i<br />

EUDP ansøgningen.<br />

9. Publikationer<br />

Projektet blev preæsenteret ved et mundtlig indlæg af IRD Fuel Cells (Madeleine Odgaard) på konferencen<br />

Hydr<strong>og</strong>en and Fuel Cells 2007, 30/04/2007 Vancouver, Canada.<br />

Bilagsliste<br />

Bilag 1 – Kravspecifikation <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong>.<br />

Bilag 2 – Metanol distributions analyse<br />

Bilag 3 – Blokdiagram System Control<br />

Bilag 4 – Principdiagram System control board.<br />

Baggrunds referencer<br />

American Methanol Institute. Beyond the Internal Combustion Engine - The promise of methanol fuel cell vehicles.<br />

2000.<br />

Ref Type: Report<br />

Antizol Antizol - Methanol Poisoning Overview.<br />

Bach, W. and Aitken, B. Methanex Corporation Investor's Conference Call - Third Quarter 2006 Earnings Conference<br />

Call. 26-10-2006.<br />

Ref Type: Conference Proceeding<br />

Bossel, U., Eliasson, B., and Taylor, G. The future of the hydr<strong>og</strong>en economy: bright or bleak? 26-2-2005.<br />

Ref Type: Report<br />

Carlsen, H. DME-fuel.<br />

Cheng, W. & Kung, H. H. 1994. Methanol production and use. NY: Marcel Dekker.<br />

Eide, I., Hagemann, R., and Offenberg J.H. Methanol in fuel cell vehicles Human toxicity and risk evaluation. 2001c.<br />

Ref Type: Generic<br />

Side 25 / 26


Slutrapport EFP05_33031_0011<br />

Eide, I., Hagemann, R., and Offenberg J.H. Methanol in fuel cell vehicles Human toxicity and risk evaluation. 2001f.<br />

Ref Type: Generic<br />

Eide, I., Hagemann, R., and Offenberg J.H. Methanol in fuel cell vehicles Human toxicity and risk evaluation. 2001d.<br />

Ref Type: Generic<br />

Eide, I., Hagemann, R., and Offenberg J.H. Methanol in fuel cell vehicles Human toxicity and risk evaluation. 2001e.<br />

Ref Type: Generic<br />

Eide, I., Hagemann, R., and Offenberg J.H. Methanol in fuel cell vehicles Human toxicity and risk evaluation. 2001b.<br />

Ref Type: Generic<br />

Eide, I., Hagemann, R., and Offenberg J.H. Methanol in fuel cell vehicles Human toxicity and risk evaluation. 2001a.<br />

Ref Type: Generic<br />

EPA 1994. Methanol Fuels and Fire Safety (EPA 400-F-92-010). U.S.Environmental Protection Agency Office of Mobile<br />

Sources.<br />

Exide-shop.dk DF 12 094Y.<br />

Exide-shop.dk Exide IMC DF-charger.<br />

Exide-shop.dk Spørgsmål <strong>og</strong> svar.<br />

Flutite Nyudviklet, patenteret tankningssystem <strong>for</strong> benzin <strong>og</strong> olie<br />

til motorsave <strong>og</strong> andre småmaskiner.<br />

Et lukket ventilsystem - helt uden spild. http://www.green-gt.dk/Flutite.htm.<br />

Flutite pricelist.<br />

Fuel cells work Fuel cells slated to energize plastics demand.<br />

Hjälpmedelsinstitutet Hjälpmedelsinstitutet.<br />

Höhlein, B., Grube, T., Biedermann, P., Bielawa, H., Erdmann, G., Schlecht, L., Isenberg, G., and Edinger, R. Methanol<br />

als Energieträger. 2003.<br />

Ref Type: Report<br />

IRD IRD <strong>DMFC</strong>31M0210.<br />

IRD fuel cells, H2 l<strong>og</strong>ic, and Minicrosser. <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong> - arbejdsdokument - krav<br />

specifikation. 2006.<br />

Ref Type: Unpublished Work<br />

Methanex Methanol in our lives.<br />

Methanex Methanolprice.<br />

Methanex What are the other uses of methanol?<br />

Methanex What is Acetic Acid?<br />

Methanex What is <strong>for</strong>maldehyde?<br />

Methanex What is MTBE?<br />

Methanol Institute. Methanol Health Effects. 2006.<br />

Ref Type: Generic<br />

Miljøministeriet. Vejledning om klassificering m.v. af kemiske stoffer <strong>og</strong> produkter - klassifikationsvejledningen. 2004.<br />

Ref Type: Generic<br />

MMSA Welcome to Methanol Market Services Asia (MMSA).<br />

Mobiletrax Fuel Cells: The Nirvana of Portable System Power?<br />

Notio Plast Særtilbud - Notio Plast.<br />

Olah, G. A., Goeppert, A., & Prakash, G. K. S. 2006. Beyond Oil and Gas: The Methanol Economy. Wiley-VCH verlag<br />

gmbh & Co. Kgaa, Weinheim.<br />

Pedersen, V. S. Samtale med Salgschef Verner Søvang Pedersen Chemex Products Aps. 13-12-2006.<br />

Ref Type: Personal Communication<br />

Seigel, J. New plants evaporate supply tightness and latest price spike. www.purchasing.com . 15-7-2004.<br />

Ref Type: In Press<br />

Stundza, T. Mitsubishi expands methanol plans. www.purchasing.com . 7-12-2006.<br />

Ref Type: In Press<br />

tool4you.dk Benzindunke.<br />

udomi preisliste-udomi.<br />

Uhde. Methanol. 31-12-2006.<br />

Ref Type: Report<br />

United States Plastic Corporation LDPE and HDPE Tubing.<br />

United States Plastic Corporation Multi purpose tanks.<br />

United States Plastic Corporation Polyethylene Jerry Jugs.<br />

Wikipedia octane.<br />

Wikipedia Hydr<strong>og</strong>en.<br />

Wikipedia NFPA 704.<br />

Side 26 / 26


Senest opdateret 26_10_06<br />

Vers 04<br />

H2 L<strong>og</strong>ic<br />

<strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong><br />

<strong>anlæg</strong><br />

Arbejdsdokument<br />

Februar 2006<br />

IRD Fuel Cells<br />

H2 L<strong>og</strong>ic<br />

MiniCrosser<br />

Krav Specifikation


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Arbejdsmetode <strong>for</strong> dette dokument<br />

Dette dokument er et <strong>intern</strong>t arbejdsdokument <strong>for</strong> projektdeltagerne:<br />

- IRD Fuel Cells<br />

- H2 L<strong>og</strong>ic<br />

- MiniCrosser<br />

Dette arbejdsdokument er krav specification <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et der skal udvikles til MiniCrosser.<br />

Dokumentet beskriver først de overordnede krav til køretøjet, <strong>og</strong> giver efterfølgende mere detaljeret krav<br />

spec til PowerUnit <strong>og</strong> de enkelte delkomponenter i systemet.<br />

Kravspecifikationsdokumentet vil løbende blive opdateret efterhånden som de enkelte komponenter<br />

designes <strong>og</strong> konstrueres.<br />

Når kravspecifikation opdateres es, skriver <strong>for</strong>fatter sig på <strong>for</strong>siden med navn <strong>og</strong> dato, hvorefter<br />

dokument fremsendes til de øvrige deltagere i projektet. – De 3 seneste opdateringer skal fremgå af<br />

<strong>for</strong>siden mens ældre opdateringer slettes.<br />

- 2 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

ARBEJDSMETODE FOR DETTE DOKUMENT........................................................................................................ 2<br />

OVERORDNEDE DRIFTSEGENSKABER FOR MINICROSSER........................................................................... 4<br />

Baggrund .............................................................................................................................................................................4<br />

KRAV-SPEC I DIVERSE BRUGSSITUATIONER...................................................................................................................... 5<br />

KRAV-SPEC TIL POWERUNIT ................................................................................................................................... 6<br />

OVERORDNET SKITSE AF KOMPLET POWERUNIT SYSTEM ................................................................................................ 7<br />

STYRINGSPRINCIPPER/TEORI ............................................................................................................................................ 9<br />

1) Driftsmodes <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et ved konstant ladestrøm........................................................................................ 9<br />

2) Driftsmodes <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et ved dynamisk <strong>for</strong>brug........................................................................................ 10<br />

Valg af styringsprincip .............................................................................................................................................. 10<br />

KRAVSPEC TIL POWERUNIT KOMPONENTER.................................................................................................. 10<br />

<strong>DMFC</strong> MODUL.............................................................................................................................................................. 11<br />

1.2.1 <strong>DMFC</strong> STAK SPECIFIKATION........................................................................................................................... 11<br />

FLUID INTERFACE ..................................................................................................................................................... 13<br />

Figur 1.2.1 <strong>DMFC</strong> stak strøm-spændnings karakteristik ..........................................................................................13<br />

Mixerkredsløb............................................................................................................................................................................16<br />

METANOL TANK ............................................................................................................................................................ 18<br />

FUEL CELL CONTROLLER (FCC).................................................................................................................................... 18<br />

SYSTEM CONTROLLER (SC).................................................................................................................................... 20<br />

BRUGERINTERFACE/DISPLAY ........................................................................................................................................ 20<br />

SERVICEINTERFACE ....................................................................................................................................................... 20<br />

DAQ (TBD PFA) .......................................................................................................................................................... 20<br />

LADER ............................................................................................................................................................................ 21<br />

PSU ............................................................................................................................................................................... 21<br />

BATTERIER .................................................................................................................................................................... 22<br />

CHASSIS......................................................................................................................................................................... 22<br />

- 3 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Overordnede driftsegenskaber <strong>for</strong> MiniCrosser<br />

Baggrund<br />

, MiniCrosser køretøjet eksisterer i 2 typer T130 <strong>og</strong> T140. – Køretøjerne har samme egenskaber <strong>og</strong><br />

hardware, men den enkelte undtagelse at T140 er længere, hvor<strong>for</strong> der er mere plads i batterirummet<br />

end på T130. De beskrevne tests er lavet på T140.<br />

Køretøjet anvendes til person<strong>transport</strong>, <strong>og</strong> kan bruges til <strong>transport</strong> over kortere eller længere distancer.<br />

Egenskaber <strong>for</strong> nuværende køretøj:<br />

- Driftsradius, distance er kortere om vinteren, da batterier har lavere kapacitet ved lavere<br />

temperatur:<br />

-<br />

56Ah (C20) 40km<br />

73Ah (C20) 60km<br />

110Ah (C20) 80km<br />

ved 24 volt giver det et gennemsnitligt <strong>for</strong>brug på 33 Wh/km<br />

Det er ønsket at give en væsentlig længere rækkevidde, specifik krav er ikke defineret.<br />

- Egenvægt på køretøj er ca. 140kg <strong>for</strong> T130 <strong>og</strong> 180kg <strong>for</strong> T140.<br />

- Maks hastighed er 15km/t (lovmæssig begrænsning)<br />

- Køretøjerne er juridisk underlagt medicin-direktivet<br />

- Strøm<strong>for</strong>brug:<br />

Ved normal kørsel (15km/t) på jævn vej: 18-20Ah 480W = 32Wh/km<br />

Ved opstart/acceleration: 40A 960W<br />

Ved normal kørsel op ad bakke: 40-45A 1080W<br />

Kortvarig peak-strøm ved opstart : 125A-130A 3120W<br />

Regenerering af strøm ved kørsel ned af bakke: 10-12A -288W<br />

Køretøjets bremser er ikke regererende - Fysisk volumen til PowerUnit:<br />

- højde: 24cm<br />

- bredde: 58 cm<br />

- dybde/længde T130: 17.8cm T140: 25.6cm<br />

- Klima<br />

Køretøjet skal kunne køre i alt slags vejr. Direkte sol <strong>og</strong> 35°C, regnvej, frost ned til -15°C.<br />

Anvendelse er såvel indendørs som udendørs. Der må ikke spildes med vand inden<strong>for</strong>.<br />

Der må ikke udledes metanoldampe eller andre giftige dampe fra systemet.<br />

- Støj<br />

Batterierne på MiniCrosser et helt lydløse, ved indendørs brug må PowerUnit’en der<strong>for</strong> ikke støje<br />

nævneværdigt. Ved udendørs kørsel vil vejstøj <strong>for</strong>ventelig overgå evt. støj fra blæsere.<br />

- Brugsmønster<br />

Der er ikke n<strong>og</strong>et entydigt brugsmønster af køretøjerne. N<strong>og</strong>le brugere køre korte ture på 5min,<br />

holder stille i 30 <strong>og</strong> kører igen i 5min, mens andre kører i 1 time i træk.<br />

- Driftstid<br />

En gennemsnitlig driftstid pr år er 500timer <strong>og</strong> en samlet levetid på 5000timer eller 10år vil være<br />

en realistisk vurdering, men brugsmønster er meget individuelt.<br />

- Optankning/opladning<br />

Brugeren har i dag en meget simpel opladning, hvor de bruger el-nettet. – Dette<br />

distributionssystem er svært at konkurrere med, hvor<strong>for</strong> det vurderes som et krav et genopfyldning<br />

- 4 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

er så simpel som mulig <strong>for</strong> brugeren. – Det skal være muligt at kunne optanke andet steds end<br />

hjemme hos brugeren. – Evt ved at kunne tage en ekstra tank med eller reservetank<br />

MiniCrosser står i dag til opladning i et frostfrit lokale, da batterierne ellers vil tage skade. – Det må<br />

der<strong>for</strong> <strong>for</strong>modes at det ikke vil være et problem at opbevare MiniCrosser frostfrit. En frostsikring vil<br />

d<strong>og</strong> altid være en d<strong>og</strong> løsning, men er et ønske <strong>og</strong> ikke et krav.<br />

- Anvendelse<br />

Brugeren tænker i dag ikke over hvordan batteriet fungeret, <strong>og</strong> det samme skal være gældende <strong>for</strong><br />

PowerUnit’en. – Den skal fungere helt uden interaktion fra brugeren.<br />

- Brugerinteraktion med strøm<strong>for</strong>syning er i dag kun en simpel indikator der viser kapacitet i <strong>for</strong>hold til<br />

spændingen over batterierne. – Brugeren skal <strong>og</strong>så i instrumentbrættet kunne se tank-niveau.<br />

Krav-spec i diverse brugssituationer<br />

Følgende situationer er identificeret til nærmere undersøgelse.<br />

1) - Koldstart på fladt underlag udendørs<br />

2) - Koldstart <strong>og</strong> bakke med det samme (15km/t)<br />

3) - Kørsel på lige gang indendørs (10km/t)<br />

4) - Køretur i supermarked 5km/t – 0km/t – 5km/t – 0km/t<br />

5) - Parkering efter lang tur<br />

1) - Koldstart på fladt underlag udendørs<br />

Hastighed 15km/t<br />

Effekt<strong>for</strong>brug ~500W<br />

Temperatur Opstart kan være fra 1-2°C <strong>og</strong> udendørs temp kan være min 15°C <strong>og</strong> maks 35°C<br />

Spild af vand Der må godt slippes vand ud<br />

Støj Så længe støjniveau er mindre end motor- <strong>og</strong> vejstøj er det intet problem.<br />

Minimum tid i situation Fra start kan køretøjet <strong>for</strong>blive i denne situation i flere timer<br />

Specielle krav -<br />

2) - Koldstart <strong>og</strong> bakke med det samme (15km/t)<br />

Hastighed 15km/t<br />

Effekt<strong>for</strong>brug ~1000 - 1100W<br />

Temperatur Opstart kan være fra 1-2°C <strong>og</strong> udendørs temp kan være min 15°C <strong>og</strong> maks 35°C<br />

Spild af vand Der må godt slippes vand ud<br />

Støj Så længe støjniveau er mindre end motor- <strong>og</strong> vejstøj er det intet problem.<br />

Minimum tid i situation Det sættes som mål at der maks køres op ad bakke i 20min. Efter 20 min vil<br />

motorstyringen alligevel blive meget varm <strong>og</strong> slå fra, eller brugeren må nøjes med<br />

at gå ned i effekt/hastighed.<br />

Specielle krav -<br />

3) – Kørsel på lige gang indendørs (10km/t)<br />

Hastighed 10km/t<br />

Effekt<strong>for</strong>brug ~300-400W<br />

Temperatur Temp 10-25°C<br />

Spild af vand Der må ikke spildes vand<br />

Støj Støj skal holdes på et minimum<br />

Minimum tid i situation Brugeren kan blive i denne situation i flere timer<br />

Specielle krav -<br />

4) – Kørsel i supermarked 5km/t – 0km/t – 5 km/t – 0km/t<br />

Hastighed 0-5km/t start <strong>og</strong> stop mange gange.<br />

Effekt<strong>for</strong>brug ~0-400W, peaks på 900W <strong>og</strong> ofte <strong>og</strong> kort regenerering<br />

Temperatur Temp 10-25°C<br />

Spild af vand Der må ikke spildes vand<br />

Støj Støj skal holdes på et minimum<br />

Minimum tid i situation Brugeren kan blive i denne situation i flere timer (messecenter besøg / gågade)<br />

Specielle krav -<br />

5) – Parkering efter lang tur<br />

- 5 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Hastighed 0 km/t<br />

Effekt<strong>for</strong>brug 0W til fremdrift, men der skal lades på batteri, da dette kan være helt afladt<br />

Temperatur 1-30°C<br />

Spild af vand Der må ikke spildes vand<br />

Støj Der må ikke være n<strong>og</strong>en nævneværdig strøm<br />

Minimum tid i situation Indtil batterier er opladet<br />

Specielle krav -<br />

Tabel 1 Brugssituationer <strong>for</strong> MiniCrosser.<br />

Krav-spec til PowerUnit<br />

Herunder er krav fra de <strong>for</strong>skellige driftssituationer af MiniCrosser samlet i en overordnet krav spec <strong>for</strong><br />

PowerUnit’en.<br />

Samlet overordnet krav-spec til PowerUnit<br />

Effekt<strong>for</strong>brug 0-1500W<br />

Tilpasning til ideel BC produktion på 500-600W<br />

Power Unit skal konstrueres til dynamisk effekt<strong>for</strong>brug fra 0-1500W, jævnfør<br />

brugssituationer som beskrevet i tabel 1.<br />

Der skal kunne trækkes 1100W i op til 20min.<br />

Der må tillades peak belastning på 3500W i max 3 sek til opstart..<br />

Der skal være mulighed <strong>for</strong> at anvende regenerering. Maks 500W ladning i 10sek.<br />

Temperatur PowerUnit vil ikke stå slukket i frost, men kan køre i frost ned til -15°C<br />

Maks temperatur er 35°C + direkte sol<br />

PowerUnit’en må gerne frostsikres, men dette er kun et ønske <strong>og</strong> ikke krav<br />

Spild af vand Ved udendørs kørsel må der spildes vand <strong>og</strong> ved indendørs kørsel må der ikke<br />

spildes vand. – Der kan ikke direkte identificeres et driftsmønster <strong>for</strong> garanteret<br />

udendørs kørsel. Det bør overvejes at undgå spild overhovedet.<br />

Støj Ved 15km/t kørsel er der støj fra hjul <strong>og</strong> motor, hvor<strong>for</strong> PowerUnit godt må støje<br />

lidt. Ved kørsel ved lavere hastigheder skal støj minimeres, <strong>og</strong> ved dynamisk<br />

kørsel skal støj <strong>og</strong>så holdes på et minimum<br />

Minimum tid i situation Der kan ikke identificeres standard situationer, hvor<strong>for</strong> det skal antages at der kan<br />

ske skifte mellem alle situationer uafhængig af tidligere situation.<br />

Specielle krav Ved udendørs kørsel skal PowerUnit være modstandsdygtig over<strong>for</strong> fugt <strong>og</strong> være<br />

stænktæt. Hvis der ikke vælges at bruge et skjold til at dække PowerUnit, skal<br />

den være modstandsdygtig over<strong>for</strong> direkte vandsprøjt (IP44 NB find<br />

standard,vedlæg som bilag).<br />

Tabel 2 Krav specifikation til PowerUnit<br />

Der skal være beskyttelse mod støv <strong>og</strong> sand, da dette vil blive hvirvlet op omkring<br />

PowerUnit’en.<br />

Der vil komme mange dynamiske rystelser hvilket PowerUnit skal være<br />

modstandsdygtig over<strong>for</strong>. – Statiske belastninger op til XXN (Svarende til 10km/t<br />

ind i væg) skal PowerUnit <strong>og</strong>så kunne modstå uden skade. Udbydning <strong>og</strong><br />

definition fra MiniCrosser<br />

Der må ikke være n<strong>og</strong>en giftige dampe fra PowerUnit. (jvf. Arbejstilsynets vedlag<br />

som bilag).<br />

- 6 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Overordnet skitse af komplet PowerUnit system<br />

Air intake<br />

Air to ambient<br />

H2O drain<br />

xI<br />

Data & Control Signals<br />

(External)<br />

CH3OH tank<br />

03-00-00<br />

FCC<br />

Fuel Cell<br />

Controller<br />

02-00-00<br />

Meaning of Sensor/Indicator symbols, x:<br />

C= Current, F=Flow H=Hydr<strong>og</strong>en, I=Current, P=Pressure, RH=Humidity, T=Temperature, V=Voltage<br />

<strong>DMFC</strong><br />

Module<br />

01-00-00<br />

DC Output<br />

DC/DC Converter<br />

04-00-00<br />

SC<br />

System<br />

Controller<br />

07-00-00<br />

Air<br />

H2O & CH3OH<br />

DC Power Control & Data<br />

Figure 1 <strong>DMFC</strong> Power Unit overordnet system diagram.<br />

Battery Charger<br />

05-00-00<br />

External<br />

Battery/Load<br />

06-00-00<br />

IRD Fuel Cell A/S, Svendborg, DK, Te<br />

Title: 722: <strong>DMFC</strong> Power Unit, System D<br />

Doc : 722 <strong>DMFC</strong> PU-DSC-00-00-00_101<br />

M<br />

- 7 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Air<br />

0-200 Nl/min<br />

at λ = 3<br />

xI<br />

Data & Control Signals<br />

Air to Ambient<br />

Air<br />

H2O drain<br />

04-04-00<br />

TBD ml/min<br />

Filter<br />

02-01-00<br />

Air pump<br />

02-02-00<br />

LI<br />

03-01-01<br />

Meaning of Sensor/Indicator symbols, x:<br />

C= Current, F=Flow H=Hydr<strong>og</strong>en, I=Current, P=Pressure, RH=Humidity, T=Temperature, V=Voltage<br />

H2O & CH3OH<br />

0.05bar(g)<br />

Water tank<br />

04-01-00<br />

HUM<br />

02-03-00<br />

0-150 ml/min<br />

<strong>DMFC</strong> Stack<br />

01-01-00<br />

DC Power<br />

CO2 Outlet<br />

05-02-00<br />

3% CH3OH<br />

04-03-00 04-02-00<br />

CVMS<br />

01-02-00<br />

0-2.5 Nl/min<br />

01-03-00<br />

CI<br />

re 2 <strong>DMFC</strong> Module [reference 01-00-00] P&I diagram.<br />

05-01-00<br />

DC Output<br />

Control & Data<br />

05-03-00<br />

Thermostat<br />

05-04-00<br />

05-01-01<br />

70ºC max<br />

LI<br />

Heat Sink<br />

06-01-00<br />

0-20 ml/min<br />

IRD Fuel Cell A/S, Svendborg, DK, Te<br />

Title: 722: <strong>DMFC</strong> Module, P&I Block D<br />

Doc No.:722 <strong>DMFC</strong>-DSC-00-00-00_101<br />

Date: 12/3/2006 Rev.: 1.01 Org.<br />

TI<br />

(100% CH3OH)<br />

(External)<br />

CH3OH tank<br />

00-00-00<br />

Figu<br />

- 8 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Styringsprincipper/teori<br />

Til den <strong>intern</strong>e styring af brændselscelle, blæsere, pumper, befugter m.v. findes der <strong>for</strong>skellige<br />

styringsprincipper. De enkelte principper beskrives herunder, hvorefter <strong>for</strong>dele <strong>og</strong> ulemper kort beskrives<br />

ved hver princip.<br />

1) Driftsmodes <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et ved konstant ladestrøm<br />

Det mest optimale <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et er at køre ved I-nominel så meget af tiden som muligt. Der vil <strong>for</strong><br />

<strong>DMFC</strong> <strong>modul</strong>et være <strong>for</strong>skellige driftsmodes:<br />

- OpstartNormaldrift<br />

- Nedlukning<br />

Opstart<br />

Denne mode er en opstartsprocedure <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et, hvor strømmen fra <strong>DMFC</strong>-<strong>modul</strong>et begrænses af<br />

cellespændingerne i 2-5 TBD intervaller, der sikre en rolig opstart <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et indtil den nominelle<br />

driftstemperatur er opnået <strong>og</strong> <strong>DMFC</strong> <strong>modul</strong>et kan yde I-nominel.<br />

Normaldrift<br />

I denne mode yder <strong>DMFC</strong> <strong>modul</strong>et en konstant strøm (I-nominel). <strong>DMFC</strong> <strong>modul</strong>et holdes i<br />

normaldriftsmode.<br />

Nedlukning<br />

I denne mode køres en nedlukningsprocedure <strong>for</strong> <strong>DMFC</strong>-<strong>modul</strong>et. Nedlukningsproceduren fastlægges i<br />

<strong>for</strong>hold til batteritype <strong>for</strong> at sikre optimal batteri levetid.<br />

Fordele:<br />

- Levetid <strong>for</strong>ventes <strong>for</strong>øget <strong>for</strong> BC.<br />

- Simplere FCC <strong>og</strong> SC styring.<br />

Ulemper:<br />

- Kræver bedre batterier <strong>og</strong> oftere udskiftning af batterier.<br />

- Giver en dårligere brændstof-økonomi, grundet energitabet gennem batterierne.<br />

samlet<br />

tid<br />

udtørring<br />

mindre levetid<br />

100%<br />

effekt i<br />

<strong>for</strong>hold til<br />

nominel<br />

- 9 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

2) Driftsmodes <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et ved dynamisk <strong>for</strong>brug<br />

Dynamisk drift mellem 0-100% vil medføre at strømmen fra <strong>DMFC</strong> <strong>modul</strong>et vil følge <strong>for</strong>bruget på<br />

batterierne <strong>og</strong> i dette tilfælde kørselsmønsteret <strong>for</strong> køretøjet.<br />

De <strong>for</strong>skellige driftsmodes:<br />

- Opstart<br />

- Dynamisk drift<br />

-<br />

- Nedlukning<br />

Opstart<br />

Denne mode er en opstartsprocedure <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et, hvor strømmen fra <strong>DMFC</strong>-<strong>modul</strong>et begrænses i<br />

2-5 TBD intervaller, der sikre en rolig opstart <strong>for</strong> <strong>DMFC</strong> <strong>modul</strong>et indtil den nominelle driftstemperatur er<br />

opnået <strong>og</strong> <strong>DMFC</strong> <strong>modul</strong>et kan yde I-nominel.<br />

Dynamisk drift<br />

I denne mode følger <strong>DMFC</strong> <strong>modul</strong>et effekt<strong>for</strong>bruget fra køretøjet. Batterierne leverer peak effekt hvis<br />

effekt<strong>for</strong>brug overstiger I-nominel. Under dynamisk drift vil <strong>DMFC</strong> <strong>modul</strong>et <strong>og</strong>så anvendes som batteri<br />

lader <strong>og</strong> der<strong>for</strong> skal power unit konstrueres i <strong>for</strong>hold til batteri type <strong>for</strong> at sikre optimal batteri levetid<br />

under opladning.<br />

Nedlukning<br />

I denne mode køres en nedlukningsprocedure <strong>for</strong> <strong>DMFC</strong>-<strong>modul</strong>et. Nedlukningsproceduren fastlægges i<br />

<strong>for</strong>hold til batteritype <strong>for</strong> at sikre optimal batteri levetid.<br />

Fordele:<br />

– Det muliggør bedre behandling af batterier<br />

Ulemper:<br />

– Det gør den <strong>intern</strong>e styring mere kompleks<br />

Vil muligvis influerer på brændselscellens levetid.<br />

Valg af styringsprincip<br />

Som stryringsprincipkan vælges en af de to beskrevne principper eller en kombination af de to principper.<br />

Vi har valgt styringsprincip med konstant ladestrøm, af hensyn til <strong>for</strong>ventet længere levetid samt<br />

simplere FCC / SC styring.<br />

Kravspec til PowerUnit komponenter<br />

Ud fra de overordnede krav-spec til MiniCrosser <strong>og</strong> PowerUnit, vil det være muligt at lave en krav-spec<br />

<strong>for</strong> de enkelte komponenter i PowerUnit. Valget af komponenter er en iterativ proces, hvor de enkelte<br />

komponenter har indflydelse på hinanden.<br />

- 10 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

<strong>DMFC</strong> <strong>modul</strong><br />

Baseret på den overordnede kravspecifikation (Tabel 2) <strong>for</strong> brændselscelle generatoren (<strong>DMFC</strong> Power<br />

Unit) opstilles følgende krav til <strong>DMFC</strong> <strong>modul</strong>et:<br />

• Celle type: <strong>DMFC</strong> (Direct Methanol Fuel Cell)<br />

• Brændstof: kommerciel tilgængelig metanol (ikke speciel laboratorie renhed)<br />

• Nominal Power: 600 W<br />

• Omgivelses temperatur under drift: -15 °C til 35°C<br />

• Omgivelses temperatur ved stand-by: > 0°C op til 35°C<br />

• Støj: generelt lav<br />

• Rystelser: skal kunne modstå vibrationer ved normal kørsel<br />

<strong>DMFC</strong> <strong>modul</strong>et består af brændsels celle stak, med tilhørende B-o-P (Balance-of-Plant) komponenter. Del<br />

komponenter i <strong>modul</strong>et består af følgende hovedkredsløb;<br />

• Luft<strong>for</strong>syning<br />

• Køler/kondenser<br />

• Mixerkredsløb<br />

• Extern metanol tank<br />

Ud fra de overordnede krav til <strong>DMFC</strong> <strong>modul</strong>et kan specifikationer <strong>for</strong> brændselscelle stakken <strong>og</strong> de<br />

enkelte komponenter fastlægges.<br />

1.2.1 <strong>DMFC</strong> Stak Specifikation<br />

Specifikation <strong>for</strong> brændselscelle stakken (Tabel 1.2.2) er baseret på den overordnet <strong>DMFC</strong> <strong>modul</strong><br />

specifikation med et effekt krav på 600 W nominelt, samt nedenstående specifikation <strong>for</strong> IRD’s <strong>DMFC</strong><br />

MEA (Membrane Electrode Assembly) effekttæthed, tabel 1.2.1.<br />

<strong>DMFC</strong> Celle Specifikation:<br />

MEA power density nominal 100 mW/cm 2<br />

MEA area 180 cm 2<br />

Cell Current, nominal<br />

45 A<br />

Cell voltage, nominal 0.4 V<br />

Operating temperature, nominal 70-75°C<br />

Tabel 1.2.1<br />

<strong>DMFC</strong> Stak Specifikation:<br />

- 11 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

No of cells 35<br />

Fuel Supply Methanol / Air<br />

Stack Power, nominal 630 W<br />

Stack Power, max 800 W<br />

Stack Current, nominal 45 A<br />

Stack Voltage, nominal @ B-o-L 14 V<br />

Heat, P W [HHV] 1335 W<br />

Operating stack temperature, nominal 70-75°C<br />

Fuel pressure (max) 0.05 bar(g)<br />

Water Consumption rate (λ=1) 0.18 kg/h<br />

Methanol Consumption rate (λ=1) 0.40 l/h<br />

Air Consumption rate(λ=1) 1.57 Nm 3 /h<br />

Air pressure ambient<br />

Air supply rate (λ=3.0) 4.72 Nm 3 /h<br />

Internal methanol supply concentration 1.0 M<br />

Fuel circulation flow rate @ 1.0M, nominal 58.7 l/h<br />

Mechanical:<br />

Stack Dimensions (excl. connectors) 171 mm x 184 mm x 184 mm<br />

Stack Weight ~ 7 kg<br />

Tabel 1.2.2.<br />

- 12 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

STAK INTERFACE SPECIFIKATION<br />

ELECTRICAL INTERFACE<br />

Fluid interface<br />

MECHANICAL INTERFACES<br />

TABEL 1.2.3.<br />

Strøm-spændings karakteristik <strong>for</strong> <strong>DMFC</strong> brændselscelle stakken ved nominel driftsbetingelse er vist i<br />

figur 1.2.1.<br />

Stack Voltage [V]<br />

30,0<br />

25,0<br />

20,0<br />

15,0<br />

10,0<br />

5,0<br />

0,0<br />

<strong>DMFC</strong> Stack Per<strong>for</strong>mance:<br />

1.0 M CH3OH, λ Air = 3, λ CH3OH = 6, Tstack = 70-75°C, ambient pressure (∆p = max. 50mBar)<br />

Stack Voltage<br />

Stack Power<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75<br />

Stack Current [A]<br />

Figur 1.2.1 <strong>DMFC</strong> stak strøm-spændnings karakteristik<br />

Luft<strong>for</strong>syning<br />

900<br />

750<br />

600<br />

450<br />

300<br />

150<br />

0<br />

Stack Power [W]<br />

- 13 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Funktion er <strong>for</strong>syning af luft (ilt) til katode siden i brændselscelle stakken. De bedste betingelser <strong>for</strong> det<br />

nuværende <strong>DMFC</strong> stak design opnås med cirkulation af luft gennem stakken med overskud af ilt<br />

(λ Air=3.0). Af hensyn til minimal tab af metanol samt opretholdelse af korrekt fugtighed i alle cellerne<br />

<strong>for</strong>synes stakken med luft gennem en befugter. Brændselscellen producerer vand på ilt siden,<br />

afgangsluften benyttes til at befugte tilgangsluften. Baseret på brændselscelle specifikationen, kan flow<br />

kapaciteten beregnes, se tabel 1.2.4.<br />

<strong>DMFC</strong> STACK LOAD<br />

Cathode Air flow calculation<br />

Electrode Area 180 cm 2<br />

Lambda =X # of Cells<br />

3 35,0<br />

Current Current Stoichiometric flow Air flow rate Air flow rate<br />

Density @ const λ = 1 @ const λ =X<br />

A A/cm 2<br />

l [O2] / min mln/min ln/min<br />

0,00 0,000 0,00E+00 0 0,0<br />

1,85 0,010 6,43E-03 31 3,2<br />

3,58 0,020 1,25E-02 59 6,2<br />

5,42 0,030 1,89E-02 90 9,5<br />

7,15 0,040 2,49E-02 119 12,5<br />

9,00 0,050 3,14E-02 149 15,7<br />

10,85 0,060 3,78E-02 180 18,9<br />

13,50 0,075 4,71E-02 224 23,5<br />

18,00 0,100 6,27E-02 299 31,4<br />

22,50 0,125 7,84E-02 373 39,2<br />

27,00 0,150 9,41E-02 448 47,1<br />

31,50 0,175 1,10E-01 523 54,9<br />

36,00 0,200 1,25E-01 598 62,7<br />

40,50 0,225 1,41E-01 672 70,6<br />

45,00 0,250 1,57E-01 747 78,4<br />

49,50 0,275 1,73E-01 822 86,3<br />

54,00 0,300 1,88E-01 896 94,1<br />

63,00 0,350 2,20E-01 1046 109,8<br />

72,00<br />

Tabel 1.2.4 Kapacitet af luft.<br />

0,400 2,51E-01 1195 125,5<br />

Kravspecifikation <strong>for</strong> luft<strong>for</strong>syning (pumpe) er:<br />

Kapacitet: 0-125 nl/min<br />

Støj: Generelt lav<br />

Efficiency: TBD<br />

Fysisk: Generelt kompakt <strong>og</strong> lav vægt<br />

Temperatur område, drift -15 to 80 °C<br />

Forsynings spænding: 24V/12V/5V<br />

Tryk: 0-0.05 Bar (g)<br />

Levetid: 5000 timer<br />

- 14 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Hvis <strong>for</strong>synings spændingen varierer må dette ikke have indflydelse på flowet.Styring af<br />

luftpumpen varetages af FCC (Fuel Cell Controlleren) ud fra stakkens energibehov <strong>og</strong> cellespænding.<br />

Køler/kondenser<br />

Ved nominel drift vil ca. 70 % af energien fra brændselscellen produceres som varme, se tabel<br />

1.2.5. Af hensyn til stakkens levetid <strong>og</strong> optimal per<strong>for</strong>mance, skal systemet <strong>for</strong>hindre<br />

overophedning<br />

(> 85°C). Den <strong>intern</strong>e køling af brændselscellen kontrolleres hovedsaglig via det <strong>intern</strong>e<br />

metanol/vand kredsløb, en lille del af kølingen <strong>for</strong>egår ved <strong>for</strong>dampning af vand (luftfugtighed<br />

< 100 %). Derudover skal den eksterne køling konstrueres i overstemmelse med<br />

nedenstående:<br />

Max Kapacitet: 1500 W<br />

Driftstemperatur: > 0°C op til 85°C<br />

Omgivelses temperatur under drift: -15 °C til 35°C<br />

Omgivelses temperatur ved stand-by: > 0°C op til 35°C<br />

Materiale: Metanol/vand tolerant (max. 6.5 wt%)<br />

Materiale: Korrosions stabilt<br />

Derudover skal køle/kondenser-kredsløbet konstrueres, så overskydende vand fra iltsiden<br />

regeneres til brug i mixerkredsløbet (<strong>for</strong>syning til brændselscellens anode side).<br />

Ved indendørs kørsel må der ikke spildes vand, så eventuelt overskydende vand skal opsamles<br />

til eventuel i beholder til aftapning/udtømning.<br />

Based on HHV Based on LHV Based on ∆ g<br />

Current Power Power Efficiency Power Efficiency Power Efficiency<br />

(A) Wel Wheat η El Wheat η El Wheat η El<br />

0,0 0,00 0,00 0,66 0,00 0,75 0,00 0,69<br />

1,8 40,32 40,76 0,50 30,95 0,57 37,61 0,52<br />

3,6 76,62 80,48 0,49 61,47 0,55 74,38 0,51<br />

5,4 110,85 127,33 0,47 98,51 0,53 118,08 0,48<br />

7,2 139,71 174,48 0,44 136,46 0,51 162,28 0,46<br />

9,0 171,68 223,60 0,43 175,77 0,49 208,25 0,45<br />

10,8 203,47 272,88 0,43 215,24 0,49 254,39 0,44<br />

13,5 245,70 347,21 0,41 275,46 0,47 324,19 0,43<br />

18,0 315,63 474,92 0,40 379,25 0,45 444,23 0,42<br />

22,5 381,94 606,25 0,39 486,67 0,44 567,88 0,40<br />

27,0 440,37 745,45 0,37 601,96 0,42 699,42 0,39<br />

31,5 498,33 885,13 0,36 717,72 0,41 831,42 0,37<br />

36,0 551,88 1029,21 0,35 837,89 0,40 967,83 0,36<br />

40,5 598,19 1180,55 0,34 965,31 0,38 1111,49 0,35<br />

45,0 641,03 1335,34 0,32 1096,19 0,37 1258,62 0,34<br />

49,5 682,61 1491,40 0,31 1228,33 0,36 1407,00 0,33<br />

54,0 718,20 1653,44 0,30 1366,45 0,34 1561,37 0,32<br />

63,0 771,75 1995,17 0,28 1660,35 0,32 1887,75 0,29<br />

72,0 808,92 2353,27 0,26 1970,62 0,29 2230,51 0,27<br />

Tabel 1.2.5. Effekt El/Varme beregning.<br />

- 15 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Mixerkredsløb<br />

Brændselscelle stakken bruger lige dele vand <strong>og</strong> metanol som brændstof i en 1.0 M (nominel)<br />

blanding. Metanolen <strong>for</strong>synes fra en ekstern metanol tank (se afsnit XXX), <strong>og</strong> vandet fra<br />

afgangen på luftsiden via befugter/kondenser. Mixerkredsløbet styres af FCC (Fuel Cell<br />

Controlleren) ud fra stakkens energibehov, <strong>intern</strong> kølebehov <strong>og</strong> cellespænding.<br />

Anode 6<br />

+ −<br />

: CH 3 OH + H 2O<br />

⇒ CO2<br />

+ 6H<br />

+ e<br />

E 0 a = 0.046 V<br />

+ −<br />

Cathode : 6H<br />

+ 6e<br />

+ 3/<br />

2O2<br />

⇒ 3H<br />

2O<br />

Specifikation <strong>for</strong> brændstof cirkulations pumpe:<br />

E 0 c = 1.23 V<br />

Flow kapacitet: 0-1.6 L/min<br />

Driftstemperatur: > 0°C op til 85°C<br />

Omgivelses temperatur under drift: -15 °C til 35°C<br />

Omgivelses temperatur ved stand-by: > 0°C op til 35°C<br />

Forsynings spænding: 24V/12V/5V (?)<br />

Levetid: > 5000 timer<br />

Materiale: Metanol/vand tolerant (max. 6.5 wt%)<br />

Materiale: Korrosions stabilt<br />

Støj: Generelt lav<br />

Fysisk: Generelt kompakt <strong>og</strong> lav vægt<br />

- 16 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Nominal<br />

<strong>DMFC</strong> STACK LOAD Anode CH3OH flow calculation<br />

Electrode Area 180 cm 2<br />

[CH3OH]=c[mol/L] Lambda =X # of Cells<br />

1 6 35,000<br />

Current Current Charge Stoichiometric flow: CH3OH flow rate: CH3OH flow rate:<br />

Density At const λ = 1 At const λ =X<br />

A A/cm 2<br />

C/min mol [CH3OH] / min mln/min ln/min<br />

0,00 0,000 0,00 0,00E+00 0,000 0,000<br />

1,85 0,010 110,77 1,91E-04 0,191 0,040<br />

3,58 0,020 214,62 3,71E-04 0,371 0,078<br />

5,42 0,030 325,38 5,62E-04 0,562 0,118<br />

7,15 0,040 429,23 7,41E-04 0,741 0,156<br />

9,00 0,050 540,00 9,33E-04 0,933 0,196<br />

10,85 0,060 650,77 1,12E-03 1,124 0,236<br />

13,50 0,075 810,00 1,40E-03 1,399 0,294<br />

18,00 0,100 1080,00 1,87E-03 1,866 0,392<br />

22,50 0,125 1350,00 2,33E-03 2,332 0,490<br />

27,00 0,150 1620,00 2,80E-03 2,798 0,588<br />

31,50 0,175 1890,00 3,26E-03 3,265 0,686<br />

36,00 0,200 2160,00 3,73E-03 3,731 0,784<br />

40,50 0,225 2430,00 4,20E-03 4,197 0,881<br />

45,00 0,250 2700,00 4,66E-03 4,664 0,979<br />

49,50 0,275 2970,00 5,13E-03 5,130 1,077<br />

54,00 0,300 3240,00 5,60E-03 5,597 1,175<br />

63,00 0,350 3780,00 6,53E-03 6,529 1,371<br />

72,00 0,400 4320,00 7,46E-03 7,462 1,567<br />

Tabel 1.2.6 Flow kapacitet <strong>for</strong> cirkulationspumpe<br />

Kredsløbet konstrueres så tilførsels af metanol/vand er i overensstemmelse med opretholdelse<br />

af en konstant koncentration. De støkometriske flow af vand <strong>og</strong> metanol er beregnet, se tabel<br />

1.2.6. Tilspædningen der styres af Fuel Cell Controlleren (FCC), baseres på støm <strong>og</strong><br />

niveaufølere.<br />

- 17 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Current<br />

Tabel 1.2.6. Vand / metanol <strong>for</strong>brug som funktion af ”effektbehov” (stak strøm)<br />

Metanol Tank<br />

H2O Consumption CH3OH Consumption<br />

Der er 2 metoder til tankning.<br />

1) Udskiftelig tank, hvor tanken tages af køretøjet <strong>og</strong> udskiftes.<br />

2) Der laves en tank der passer i volumen i PowerUnit, <strong>og</strong> der fyldes på fra en stander eller ekstern<br />

tank.<br />

Umiddelbart beregning:<br />

Ved kontinuerlig produktion på 600W fra BC <strong>for</strong>bruges 564ml/timen, <strong>og</strong> en T130 kan køre 5-6 timer i<br />

dag. En <strong>for</strong>dobling af kapacitet vil kræve tank på 4liter, mens 10-dobling vil kræve 20liter tank.<br />

Fuel Cell Controller (FCC)<br />

Varetager al BoP (<strong>DMFC</strong> Module).<br />

# of Cells # of Cells<br />

35 35<br />

A mol[H2O] / min g H2O / min mln/min mln/min g CH3OH / min mln / min mln/min<br />

0,00 0,00E+00 0,00E+00 0,00E+00 0,000 0,000 0,000 0,00<br />

1,85 1,91E-04 3,45E-03 3,45E-03 0,121 0,006 0,008 0,27<br />

3,58 3,71E-04 6,68E-03 6,69E-03 0,234 0,012 0,015 0,53<br />

5,42 5,62E-04 1,01E-02 1,01E-02 0,355 0,018 0,023 0,80<br />

7,15 7,41E-04 1,34E-02 1,34E-02 0,469 0,024 0,030 1,05<br />

9,00 9,33E-04 1,68E-02 1,68E-02 0,589 0,030 0,038 1,32<br />

10,85 1,12E-03 2,03E-02 2,03E-02 0,710 0,036 0,046 1,59<br />

13,50 1,40E-03 2,52E-02 2,53E-02 0,884 0,045 0,057 1,98<br />

18,00 1,87E-03 3,36E-02 3,37E-02 1,179 0,060 0,076 2,64<br />

22,50 2,33E-03 4,20E-02 4,21E-02 1,474 0,075 0,094 3,31<br />

27,00 2,80E-03 5,04E-02 5,05E-02 1,768 0,090 0,113 3,97<br />

31,50 3,26E-03 5,88E-02 5,89E-02 2,063 0,105 0,132 4,63<br />

36,00 3,73E-03 6,72E-02 6,74E-02 2,358 0,120 0,151 5,29<br />

40,50 4,20E-03 7,56E-02 7,58E-02 2,653 0,134 0,170 5,95<br />

45,00 4,66E-03 8,40E-02 8,42E-02 2,947 0,149 0,189 6,61<br />

49,50 5,13E-03 9,24E-02 9,26E-02 3,242 0,164 0,208 7,27<br />

54,00 5,60E-03 1,01E-01 1,01E-01 3,537 0,179 0,227 7,93<br />

63,00 6,53E-03 1,18E-01 1,18E-01 4,126 0,209 0,264 9,26<br />

72,00 7,46E-03 1,34E-01 1,35E-01 4,716 0,239 0,302 10,58<br />

Systemet skal kunne genopstarte efter strømsvigt. Hvis der er behov <strong>for</strong> det, skal driftsværdier gemmes<br />

i non-volatile memory.<br />

- 18 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Air intake<br />

Air to ambient<br />

H2O drain<br />

xI<br />

Data & Control Signals<br />

(External)<br />

CH3OH tank<br />

03-00-00<br />

FCC<br />

Fuel Cell<br />

Controller<br />

02-00-00<br />

Meaning of Sensor/Indicator symbols, x:<br />

C= Current, F=Flow H=Hydr<strong>og</strong>en, I=Current, P=Pressure, RH=Humidity, T=Temperature, V=Voltage<br />

<strong>DMFC</strong><br />

Module<br />

01-00-00<br />

DC Output<br />

DC/DC Converter<br />

04-00-00<br />

SC<br />

System<br />

Controller<br />

07-00-00<br />

Air<br />

H2O & CH3OH<br />

DC Power Control & Data<br />

Figure 1 <strong>DMFC</strong> Power Unit overordnet system diagram.<br />

Battery Charger<br />

05-00-00<br />

External<br />

Battery/Load<br />

06-00-00<br />

IRD Fuel Cell A/S, Svendborg, DK, Te<br />

Title: 722: <strong>DMFC</strong> Power Unit, System D<br />

Doc : 722 <strong>DMFC</strong> PU-DSC-00-00-00_101<br />

M<br />

- 19 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

System Controller (SC)<br />

Input:<br />

– Nøgle<br />

– tankmåler<br />

–<br />

SC giver flg. signaler:<br />

– operation mode (<strong>for</strong>ventning til effekt<strong>for</strong>brug – ønske til FCC)<br />

–<br />

Brugerinterface/Display<br />

Displayet viser relevante oplysninger til brugeren, f.eks:<br />

– Tændt/slukket<br />

– Fejl (driftsmodes)<br />

– brændstofmåler<br />

– netto effekt<strong>for</strong>brug? (økonomi-kørsel eller?)<br />

Serviceinterface<br />

Formålet med serviceinterfacet er at lette idriftsættelsen <strong>og</strong> fejlsøgning. Det kan udelades på det<br />

endelige produkt. Serviceinterface skal vise:<br />

– temperatur<br />

– kølekreds<br />

– batteri<br />

– stak<br />

– spænding<br />

– stak<br />

– celler<br />

– batteri<br />

– BoP <strong>for</strong>syning (24/12/5/?)<br />

– strøm<br />

– flow<br />

– batteriets ladestand<br />

– volumen (methanol, fuelkredsløb)<br />

– status på delsystemer (ok/fejl)<br />

Serviceinterfacet skal kunne styre:<br />

– alle setpunkter (”<strong>for</strong>ce” åben-sløjfe)<br />

– delsystemer <strong>og</strong> sensor-inputs (letter fejlsøgningen).<br />

Serviceinterfacet består af en laptop PC med labview der <strong>for</strong>bindes til PowerUnit (SC?) vha. enten CAN<br />

eller en anden seriel <strong>for</strong>bindelse.<br />

DAQ (TBD PFA)<br />

CAN dataopsamler<br />

- 20 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Lader<br />

Lader på batteriet <strong>og</strong> styrer hvor meget strøm der trækkes fra FC. Step up fra stakspænding til<br />

lade/batteri spænding.<br />

Laderen får flg. setpunkter fra FCC:<br />

– I_fc,max,sp (maximum strøm der må trækkes fra FC).<br />

– U_fc,min,sp (minimum FC spænding).<br />

Laderen skal <strong>for</strong>søge at trække strømmen I_fc,max,sp fra stakken under hensyntagen til at stakkens<br />

spænding ikke kommer under I_fc,max,sp.<br />

Laderen måler på batterispændingen (laderens egen udgang) samt ladestrømmen ind på batteriet.<br />

Laderen kører under hensyntagen til batteriets tilstand (om der skal lades eller ej). Laderen kan altså<br />

sagtens trække mindre strøm fra FC end hvad FCC siger.<br />

Laderen giver signal til FCC om:<br />

– I_fc (strøm der trækkes fra FC).<br />

– U_fc (FC stakspænding).<br />

–<br />

Laderen måler flg. til eget brug:<br />

– I_lader (strøm der kommer ud af laderen)<br />

– I_bat (strøm der trækkes fra PU af Crosser)<br />

Alle signaler (<strong>og</strong>så dem til eget brug) skal sendes til SC.<br />

PSU<br />

Tager batterispænding <strong>og</strong> laver stabiliserede spændings<strong>for</strong>syning(er) til resten af systemet, herunder:<br />

– FCC<br />

– SC<br />

– <strong>DMFC</strong> Module<br />

– Lader (laver evt. sin egen ud fra batterispænding)<br />

DC Input: ca. 12-28V<br />

DC Output: 24V, 12V? 5V?<br />

- 21 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Batterier<br />

Batterier skal kunne klare:<br />

Afladning i 20min op ad bakke 1100W (45A) i 5min <strong>og</strong> herefter 600W (25A)i 15min. – Batterier skal<br />

kunne holde til afladning på 45A i 5 min <strong>og</strong> herefter 25A i 15min.<br />

Batteri skal således have ledig kapacitet på 10-12Ah, men de skal kunne holde til meget kraftig<br />

afladning.<br />

Batterier skal i 3sek kunne levere 130A.<br />

Batterier skal kunne holde til klatladning <strong>og</strong> være <strong>for</strong>beredt på ikke at få vedligeholdelsesladning.<br />

Vedholdelsesfri.<br />

For at finde det optimale batteri skal følgende batteri testes:<br />

- AGM. 24V/14Ah.<br />

Fordel - Høj strøm tæthed, stor kortslutnings strøm, vedligeholdelsesfrit.<br />

Udvidet temperatur-40°C til 50°C.<br />

Ulemper - Størrelse <strong>og</strong> vægt.<br />

- NiMH. 24V/18Ah (Sammensat pakke 2*10 celler.)<br />

Fordel - Høj strøm tæthed, stor kortslutnings strøm, 3.5m ohm, vedligeholdelsesfrit.<br />

Alm. Temperatur område. 0°C til 45°C<br />

Minimal størrelse i <strong>for</strong>hold til Bly <strong>og</strong> AGM batterier.<br />

Ulemper - Klat ladning er ikke optimal.<br />

- Lithium Ion. 25,2V/12,8Ah - 152A Peak 6 sek. (Sammensat pakke af 7*8 celler.)<br />

Fordel - Høj strøm tæthed, stor kortslutnings strøm, 3.0m ohm, vedligeholdelsesfrit.<br />

Kan klat lades. (Ved korrekt ladning lang levetid)<br />

Minimal størrelse i <strong>for</strong>hold til Bly <strong>og</strong> AGM batterier.<br />

Ulemper - Mange celler <strong>for</strong> at opnå den ønskede kabacitet.<br />

Generelt kan det siges om batterierne, at en høje peak strøm ved afladning <strong>og</strong> kraftig ladestrøm ikke er<br />

optimal <strong>for</strong> n<strong>og</strong>le af batterierne, da det vil <strong>for</strong>kort batteriernes kapacitet <strong>og</strong> levetid.<br />

Og ved ladning skal max spændinger overholdes. (Cellerne nedbrydes)<br />

SuperCap<br />

En mulighed <strong>for</strong> at fjerne den høje peak strøm ved afladning, er at kombiner batterierne med supercap.<br />

Supercap skal samles i pakker <strong>for</strong> at få den korrekte spænding.<br />

Test af:<br />

6 stk. BCAP0350 (350F/2.5V) i serie = 58F /15V.<br />

Start 15V -10A efter 23 Sek. Er spændingen faldet med 30%<br />

BCAP0350 er i stand til at afgive en peak strøm på over 100A.<br />

Som supplering til batterierne ville 12 stk. BCAP0350 (350F/2.5V) i serie (29F /30V) kunne bruges.<br />

Og kapaciteten på batterierne kan minimeres.<br />

Chassis<br />

Ved udendørs kørsel skal PowerUnit være modstandsdygtig over<strong>for</strong> fugt <strong>og</strong> være stænk tæt, IP44 1 . Der<br />

skal være beskyttelse mod støv <strong>og</strong> sand, da dette vil blive hvirvlet op omkring PowerUnit’en. Desuden<br />

skal konstruktionen kunne modstå vibrationer ved normal kørsel.<br />

Omgivelses temperatur under drift: -15 °C til 35°C<br />

Omgivelses temperatur ved stand-by: > 0°C op til 35°C<br />

1 IP-standard er beskrevet i bilag 1<br />

- 22 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Bilag 1 – IP-standard<br />

http://www.el-biksen.dk/printmenu.asp?item=6 23-5-2006<br />

Hvad betyder IP<br />

KAPITEL 803<br />

KAPSLINGSKLASSER (IP-kode)<br />

803.0 Indledning<br />

Formålet med dette kapitel er at orientere om betydningen af de IP-koder, der anvendes til angivelse af materiellets<br />

kapslingsklasse, det vil sige den grad af beskyttelse kapslingen yder.<br />

De fuldstændige bestemmelser <strong>for</strong> kapslingsklasser fremgår af IEC 60529: Degrees of protection provided by<br />

enclosures (IP Code).<br />

Kapitlet indeholder ikke ændringer eller tilføjelser til de almindelige bestemmelser i del 1 til 6, <strong>og</strong> i modsætning til<br />

andre kapitler i del 8 er der der<strong>for</strong> her anvendt en <strong>for</strong>tløbende nummerering.<br />

803.1 IP-kodens opbygning<br />

Materiel inddeles i kapslingsklasser, som angiver<br />

- dels beskyttelsen af selve materiellet mod indtrængen af fremmedlegemer <strong>og</strong> vand,<br />

- <strong>og</strong> dels beskyttelsen af personer mod berøring af farlige dele.<br />

Til angivelse af en kapslingsklasse anvendes b<strong>og</strong>staverne IP efterfulgt af to cifre <strong>og</strong> eventuelt på tredie plads et<br />

b<strong>og</strong>stav.<br />

Første ciffer angiver altid graden af beskyttelse mod, at fremmedlegemer kan trænge ind i materiellet, men samtidigt<br />

angiver det en vis mindste grad af beskyttelse af personer mod berøring med farlige dele.<br />

Andet ciffer angiver graden af beskyttelse mod, at vand kan trænge ind i materiellet.<br />

Det eventuelle b<strong>og</strong>stav på tredie plads angiver graden af beskyttelse af personer mod berøring af farlige dele, men det<br />

benyttes kun i følgende to tilfælde:<br />

- Hvis graden af berøringsbeskyttelse er højere end angivet ved første ciffer.<br />

Note<br />

F. eks. angiver betegnelsen IP2XC, at materiellet er beskyttet mod indtrængen af fremmedlegemer med en diameter<br />

på 12,5 mm eller mere, men at det yderligere yder beskyttelse mod berøring af farlige dele med et stykke værktøj,<br />

f.eks. en skruetrækker, med en diameter på 2,5 mm <strong>og</strong> en længde på 100 mm.<br />

- Hvis der kun er behov <strong>for</strong> at angive graden af berøringsbeskyttelse, mens graden af beskyttelse mod, at<br />

fremmedlegemer kan trænge ind i materiellet, er uden betydning.<br />

Note<br />

Det gælder f.eks., hvor kapslinger skal give beskyttelse mod direkte berøring som angivet i 412.2.<br />

F.eks. angiver kapslingsklassen IPXXB, at materiellet skal være beskyttet mod berøring af farlige dele med en finger,<br />

mens der ikke er krav om beskyttelse mod indtrængen af fremmedlegemer.<br />

Hvis det f.eks. i en <strong>for</strong>skrift eller specifikation kun er nødvendigt at stille krav til kapslingsklassen med hensyn til de<br />

egenskaber, som karakteriseres af det ene af cifrene eller af b<strong>og</strong>stavet på tredie plads, erstattes det eller de cifre, som<br />

karakteriserer egenskaber, hvortil der ikke stilles krav, med et X.<br />

803.2 Betydningen af cifre <strong>og</strong> b<strong>og</strong>staver<br />

Betydningen af de <strong>for</strong>skellige cifre <strong>og</strong> b<strong>og</strong>staver fremgår af tabel 803 A, 803 B <strong>og</strong> 803 C.<br />

803.3 Sammenhæng mellem første ciffer <strong>og</strong> et eventuelt b<strong>og</strong>stav<br />

En sammenligning af kravene vedrørende beskyttelse mod berøring af farlige dele <strong>for</strong> henholdsvis første ciffer (tabel<br />

803 A) <strong>og</strong> det eventuelle b<strong>og</strong>stav på tredie plads (tabel 803 C) viser, at første ciffer lig 1 fuldt ud opfylder kravene<br />

angivet under b<strong>og</strong>stav A.<br />

Tilsvarende gælder <strong>for</strong> første ciffer lig 2 <strong>og</strong> b<strong>og</strong>stav B, første ciffer lig 3 <strong>og</strong> b<strong>og</strong>stav C <strong>og</strong> første ciffer lig 4 <strong>og</strong> b<strong>og</strong>stav<br />

D.<br />

Det betyder, at såfremt der i en bestemmelse er <strong>for</strong>eskrevet en kapslingsklasse på f.eks. IPXXB, kan der umiddelbart<br />

anvendes materiel med kapslingsklasse IP2X (eller en højere kapslingsklasse).<br />

Det betyder samtidigt, at det <strong>for</strong> materiel kun er nødvendigt at anvende et b<strong>og</strong>stav på tredie plads i IP-koden i de få<br />

tilfælde, hvor graden af beskyttelse mod berøring af farlige dele er højere end beskyttelsen angivet ved første ciffer, se<br />

tabel 803 D. Kun i de 6 tilfælde, der er markeret med fed kursiv skrift i tabellen, er det således nødvendigt at angive et<br />

b<strong>og</strong>stav på tredie plads i IP-koden.<br />

Klik <strong>for</strong> tabel: Tabel 803 D Sammenhæng mellem den <strong>for</strong>eskrevne kapslingsklasse af hensyn til<br />

berøringsbeskyttelse <strong>og</strong> kapslingsklassen <strong>for</strong> det anvendte materiel<br />

Note<br />

Første ciffer lig 0, som angiver, at materiellet ikke er beskyttet mod indtrængen af fremmedlegemer, er udeladt i<br />

tabellen, da det må anses <strong>for</strong> uaktuelt i denne sammenhæng.<br />

803.4 Valg af materiel<br />

Findes en type materiel ikke i en <strong>for</strong>eskreven udførelse, skal der benyttes materiel af en højere kapslingsklasse.<br />

Note<br />

Hvor det er påkrævet, at der anvendes materiel af kapslingsklasse IPX5 eller IPX6, må der d<strong>og</strong> ikke anvendes<br />

- 23 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

materiel af kapslingklasse IPX7 eller IPX8, medmindre fabrikanten garanterer, at det pågældende materiel samtidigt<br />

opfylder kravene <strong>for</strong> den lavere kapslingsklasse. Sådant materiel bør være dobbeltmærket, f.eks. IPX5/IPX7.<br />

el 803 A IP-kode, første ciffer<br />

Første ciffer<br />

Kort beskrivelse<br />

Krav til udførelse<br />

0<br />

Ubeskyttet<br />

Ingen særlig beskyttelse<br />

1<br />

Beskyttet mod faste genstande med en diameter på 50 mm eller mere.<br />

En kugle med en diameter på 50 mm må ikke trænge ind i materiellet.<br />

Beskyttet mod berøring af farlige dele med bagsiden af en hånd.<br />

Kuglen skal <strong>for</strong>blive i tilstrækkelig afstand fra farlige dele.<br />

2<br />

Beskyttet mod faste genstande med en diameter på 12,5 mm eller mere.<br />

En kugle med en diameter på 12,5 mm må ikke kunne trænge inde i materiellet.<br />

Beskyttet mod berøring af farlige dele med en finger.<br />

En leddelt prøvefinger med en diameter på 12 mm <strong>og</strong> en længde på 80 mm skal <strong>for</strong>blive i tilstrækkelig afstand fra<br />

farlige dele.<br />

3<br />

Beskyttet mod faste genstande med en diameter på 2,5 mm eller mere.<br />

En prøvepind med en diameter på 2,5 mm må ikke kunne trænge ind i materiellet.<br />

Beskyttet mod berøring af farlige dele med et stykke værktøj.<br />

Prøvepinden skal <strong>for</strong>blive i tilstrækkelig afstand fra farlige dele.<br />

4<br />

Beskyttet mod faste genstande med en diameter på 1,0 mm eller mere.<br />

En stiv prøvepind med en diameter på 1,0 mm må ikke kunne trænge ind i materiellet.<br />

Beskyttet mod berøring af farlige dele med tråde o.l.<br />

Prøvepinden skal <strong>for</strong>blive i tilstrækkelig afstand fra farlige dele.<br />

5<br />

Støvskærmet.<br />

Indtrængen af støv er ikke helt <strong>for</strong>hindret, men støv må ikke trænge ind i en sådan mængde, at det påvirker<br />

materiellets funktion eller sikkerhed.<br />

6<br />

Støvtæt.<br />

Der må ikke kunne trænge støv ind i materiellet.<br />

Tabel 803 B IP kode, andet ciffer<br />

Andet ciffer<br />

Kort beskrivelse<br />

Krav til udførelse<br />

0<br />

Ubeskyttet.<br />

Ingen særlig beskyttelse.<br />

1<br />

Beskyttet mod vanddråber.<br />

Lodret faldende vanddråber må ikke have n<strong>og</strong>en skadelig virkning.<br />

2<br />

Beskyttet mod vanddråber ved hældning på maksimalt 15°.<br />

Lodret faldende vanddråber må ikke have n<strong>og</strong>en skadelig virkning, når kapslingen hælder med en vinkel på 15° i<br />

<strong>for</strong>hold til sin normale stilling.<br />

3<br />

Beskyttet mod regn.<br />

Vand, der falder som regn med en vinkel på op til 60° med lodret plan, må ikke have n<strong>og</strong>en skadelig virkning.<br />

4<br />

Beskyttet mod oversprøjtning.<br />

Vand der sprøjter mod kapslingen fra enhver retning, må ikke have n<strong>og</strong>en skadelig virkning.<br />

5<br />

Beskyttet mod vandstråler.<br />

Vand fra et strålerør rettet mod kapslingen fra enhver retning må ikke have n<strong>og</strong>en skadelig virkning.<br />

6<br />

Beskyttet mod kraftige vandstråler.<br />

Kraftige vandstråler rettet mod kapslingen fra enhver retning må ikke have n<strong>og</strong>en skadelig virkning.<br />

7<br />

- 24 -


Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

Beskyttet mod følgerne af <strong>for</strong>bigående nedsænkning i vand.<br />

Det må ikke være muliget <strong>for</strong> vand at trænge ind i skadelige mængder, når kapslingen er nedsænket i vand under<br />

definerede betingelser med hensyn til tryk <strong>og</strong> tid.<br />

8<br />

Beskyttet mod følgerne af langvarig nedsænkning i vand.<br />

Det må ikke være muligt <strong>for</strong> vand at trænge ind i skadelige mængder, når kapslingen langvarigt er nedsænket i vand.<br />

Tabel 803 C IP-kode, eventuelt b<strong>og</strong>stav på tredie plads<br />

B<strong>og</strong>stav<br />

Kort beskrivelse<br />

Krav til udførsel<br />

A<br />

Beskyttet mod berøring af farlige dele med bagsiden af en hånd.<br />

En kugle med en diameter på 50 mm skal <strong>for</strong>blive i tilstrækkelig afstand fra farlige dele.<br />

B<br />

Beskyttet mod berøring af farlige dele med en finger.<br />

En leddelt prøvefinger med en diameter på 12 mm <strong>og</strong> en længde på 80 mm skal <strong>for</strong>blive i tilstrækkelig afstand fra<br />

farlige dele.<br />

C<br />

Beskyttet mod berøring af farlige dele med et stykke værktøj.<br />

En prøvepind med en diameter på 2,5 mm <strong>og</strong> en længde på 100 mm skal <strong>for</strong>blive i tilstrækkelig afstand fra farlige<br />

dele.<br />

D<br />

Beskyttet mod berøring af farlige dele med tråde o.l.<br />

En stiv prøvepind med en diameter på 1,0 mm <strong>og</strong> en længde på 100 mm skal <strong>for</strong>blive i tilstrækkelig afstand fra farlige<br />

dele.<br />

Note Der stilles ikke krav om, at kuglen, prøvefingeren, prøvepinden eller prøvetråden ikke må kunne trænge ind i<br />

materiellet. Det kræves kun, at de ikke må kunne komme <strong>for</strong> tæt på farlige dele, hvilket f.eks kan <strong>for</strong>hindres med<br />

<strong>intern</strong>e afskærmninger o.l.<br />

- 25 -


<strong>DMFC</strong> <strong>modul</strong> <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />

H2 L<strong>og</strong>ic har set på de muligheder metanol som energibærer giver, herunder specielt ved brug i<br />

Minicrosser. Alle de sikkerhedsmæssige, distributionsmæssige, praktiske mv. overvejelser man skal gøre<br />

sig før metanol kan bruges som energibærer i <strong>mobile</strong> applikationer generelt <strong>og</strong> i Minicrosser T-140<br />

specifikt er <strong>for</strong>søgt gennemgået i et længere <strong>intern</strong>t dokument. I det nedenstående er de vigtigste<br />

konklusioner <strong>og</strong> anbefalinger opsummeret.<br />

Konklusioner<br />

Kendetegn ved den optimale energibærer<br />

Den optimale energibærer til brug i <strong>mobile</strong> applikationer har uanset valg af teknol<strong>og</strong>i følgende<br />

kendetegn;<br />

* er flydende ved temperaturer mellem – 40 <strong>og</strong> 80 °C, idet den hermed er let at opbevare <strong>og</strong><br />

<strong>transport</strong>ere<br />

* let at producere ud fra såvel fossile som vedvarende energikilder, idet en transition fra fossile<br />

energikilder til fremtidige vedvarende energikilder hermed lettes <strong>og</strong> en CO 2 neutral produktion er mulig<br />

* ugiftigt, idet det hermed er let <strong>og</strong> sikkert at omgås<br />

* så lidt brandfarligt som muligt<br />

* billigt at producere<br />

* muligt at producere i store mængder<br />

* har en høj volumenenergitæthed<br />

* har en høj vægtenergitæthed<br />

Hvis energibæreren skal anvendes i brændselsceller har den optimale energibærer heller ikke n<strong>og</strong>en<br />

kulstof til kulstof (C-C) bindinger, der er svære at ”knække” i en brændselscelle, <strong>og</strong> energibæreren har<br />

en høj renlighed, således at degradering af cellerne minimeres.<br />

Metanol som energibærer<br />

Metanol har en lang række <strong>for</strong>dele som energibærer. Metanol er således flydende ved temperaturer<br />

mellem – 98 °C <strong>og</strong> 64 °C <strong>og</strong> er der<strong>for</strong> let at opbevare <strong>og</strong> distribuere i et eksisterende (eller lettere<br />

modificeret) brændstofdistributionssystem. Metanol kan produceres ud fra vedvarende energikilder, <strong>og</strong> de<br />

eneste restprodukter ved energiomsætning i en <strong>DMFC</strong> er CO2, H 2O <strong>og</strong> varme. Metanol er mindre giftigt<br />

målt på de fleste parametre end benzin, <strong>og</strong> er således f.eks. ikke kræftfremkaldende som benzin er det.<br />

Metanol er d<strong>og</strong> ca. en halv gang giftigere end benzin ved oral indtagelse, men <strong>for</strong>giftning kan relativt let<br />

behandles ved hjælp af etanol (almindelig alkohol). Metanol er kun ca. 1/8 så farligt som benzin ved<br />

brand, hvilket skyldtes metanols lavere energiindhold, lavere <strong>for</strong>dampningsevne, højere nedre<br />

grænseværdi <strong>for</strong> eksplosionsfare, lavere brandhastighed <strong>og</strong> en betydeligt lavere varmeudvikling end ved<br />

benzin. Metanol er <strong>og</strong>så muligt at producere billigt i meget store mængder. Hvis al den gas der flares pt.<br />

blev omdannet til metanol ville metanolproduktionen kunne stige fra de nuværende 32.000 mio. tons til<br />

188.000 tons om året <strong>og</strong> merproduktionen vil kunne drive ca. 95 mio. FCV om året. Til sammenligning<br />

var der i 2003 95,7 mio. biler i Italien, UK <strong>og</strong> Spanien tilsammen. Metanol er <strong>og</strong>så billigt <strong>og</strong> let at<br />

producere i store mængder. Gas produceret tæt på tætbebyggede områder distribueres normalt til disse<br />

markeder i rørledninger <strong>og</strong> alternativt som LPG. Gas der produceres langt fra tætbebyggede områder<br />

flares derimod i store mængder. Denne afbrændte gas har pr. definition ingen værdi <strong>og</strong> er dermed så at<br />

sige gratis (hvis dette ikke var tilfældet ville olieselskaberne have videre<strong>for</strong>arbejdet gassen i stedet <strong>for</strong> at<br />

brænde den af). Eksperter har således estimeret at metanol kan produceres <strong>for</strong> mindre end $ 100 pr. ton<br />

(2003 $-priser). Dette skal sammenlignes med at den aktuelle pris er i et rekordhøjt leje på $ 599 pr.<br />

tons. $ 100 pr. tons svarer til en produktionspris på 46 øre pr. l. Metanol kan let distribueres fra f.eks.<br />

mellemøsten <strong>og</strong> Sibirien med henholdsvis olietankere <strong>og</strong> 100 tons jernbanev<strong>og</strong>ne på samme måde som<br />

man <strong>transport</strong>erer olie fra områder, hvor det ikke har kunnet betale sig at <strong>anlæg</strong>ge rørledninger. På<br />

nuværende tidspunkt anvendes 92 % af den producerede metanol i den kemiske industri. Denne<br />

metanol, der kendes som Grade AA har en garanteret renhed på minimum 99,85 %. Det betyder at der<br />

ikke skal bruges tid, kræfter <strong>og</strong> penge på en yderligere oprensning af metanolen, men at denne kan<br />

anvendes direkte i <strong>DMFC</strong>. På sigt bør energibærere prodeceres på baggrund af vedvarende energi.<br />

Metanol kan produceres på baggrund af fossile energibærere, ved at binde C02 fra atmosfæren <strong>og</strong> ved<br />

biomasse. Især muligheden <strong>for</strong> at producere metanol på baggrund af genmodificerede alger vurderes der<br />

på mere end 10 års sigt at være gode muligheder i. Den danske <strong>for</strong>sker Morten Sommer fra Harvard<br />

University har således vurderet at genmodificerede alger kan producere biobrændstoffer (herunder<br />

metanol) ca. 200 gange mere energieffektivt end landbaserede afgrøder såsom sukkerrør, oliepalmer,<br />

1


aps, korn mv., <strong>og</strong> til en konkurrencedygtig pris. Morten Sommer vurderer at 0,3 % af klodens overflade<br />

kan dække hele jordens samlede energibehov. I danske <strong>for</strong>hold svarer det til at et areal på 20 * 30 km er<br />

stort nok til at kunne dække Danmarks behov <strong>for</strong> brændstoffer.<br />

Nuværende teknol<strong>og</strong>i i Minicrosser – <strong>og</strong> dennes implikationer<br />

På nuværende tidspunkt anvendes der i den valgte Minicrosser (model T-140) to stk. DF 12 094 Y<br />

blygelbatterier fra firmaet Exide Technol<strong>og</strong>y. Batterierne vejer tilsammen små 80 kg. <strong>og</strong> fylder mere end<br />

35 l. Batterierne kan kun aflades 70 %, de koster 7367,50 kr. incl. moms <strong>og</strong> <strong>for</strong>sendelse <strong>og</strong> de kan kun<br />

oplades 450 gange før ydelsen falder. Deres ydelse er desuden stærkt afhængig af temperaturen, <strong>og</strong><br />

deres ydelse falder til 75 % ved 0 °C <strong>og</strong> er helt nede på 50 % ved – 18 °C. Batterierne tager ifølge<br />

producenten 10 – 12 timer om at blive ladet op. I praksis betyder dette, at den nuværende teknol<strong>og</strong>i er<br />

tung, at den fylder meget, at der er lang ”optankningstid” <strong>og</strong> at batterierne er upålidelige. Det er således<br />

kun nye batterier, der kører på flad vej <strong>og</strong> ved 25 °C der kan køre de lovede 5 -6 timer på en<br />

optankning. Hvis batterierne er ved at være slidte, hvilket de allerede begynder at være efter et år,<br />

<strong>og</strong>/eller det er koldere eller varmere end 25 °C reduceres batteriydelsen drastisk. Eftersom dette er reelle<br />

<strong>og</strong> realistiske brugssituationer oplever brugerne at de ikke kan køre ret langt før batterierne skal lades<br />

op. Det gør brugerne usikre på om de kan komme frem <strong>og</strong> tilbage på en ”optankning”, hvor<strong>for</strong> det<br />

<strong>for</strong>modes at mange føler sig tvunget til at blive hjemme <strong>og</strong>/eller at bevæge sig inden<strong>for</strong> en meget<br />

begrænset radius fra hjemmet <strong>og</strong> ladestationen. Der sker hermed reelt det, at brugerne gøres mere<br />

bevægelseshæmmede <strong>og</strong> handicappede end tilfældet i en optimal situation kunne være.<br />

Metanol i Minicrosser<br />

Ved at anvende metanol som energibærer kan ladetiden på 10 – 12 timer nedbringes til en<br />

optankningstid på maksimalt to minutter.<br />

Driftstiden på en fuld opladning/fuld tank vil med en tankstørrelse på blot 3,5 l kunne <strong>for</strong>dobles i <strong>for</strong>hold<br />

til nye batterier ved 25 °C <strong>og</strong> kunne triples ved en tankstørrelse på 5,0 l. Idet mange brugere kører med<br />

gamle batterier <strong>og</strong> ved andre temperaturer end 25 °C vil brugerne reelt opleve en langt større <strong>for</strong>bedring.<br />

Det vurderes at brugerne vil opleve at en tank på 5 liter reelt giver en <strong>for</strong>bedring af kørselsradius på 4 –<br />

5 gange den de oplever med den nuværende teknol<strong>og</strong>i.<br />

Prisen på metanol er rekordhøj <strong>og</strong> koster i januar måned 2007 $ 599 pr. ton, svarende til 3,48 kr. pr. kg.<br />

Den metanol der kommer til Danmark kommer fra Statoils fabrik i Norge <strong>og</strong> har en meget høj renhed,<br />

hvilket skyldtes at denne er destilleret fire gange mod de normale tre <strong>for</strong> Grade AA. Idet hver destillation<br />

koster ca. 2 % vurderes det at Statoils metanol i indkøb <strong>for</strong> de store grossister er en smule dyrere, (men<br />

<strong>og</strong>så renere) end metanol fra andre leverandører. Metanolen indskibes til havnene i Esbjerg <strong>og</strong> Aabenraa<br />

af firmaet Chemex, der benytter IAT til <strong>transport</strong> <strong>og</strong> levering af metanolen. Ved 1000 l leveret på Tjelevej<br />

42 koster metanolen 4,45 kr. pr. kg. Eftersom det er normalt at give rabat til storkunder, vurderes det at<br />

Chemex har givet 3,45 kr. pr. kg <strong>for</strong> metanolen. Det betyder at Chemex tager 1 kr. i levering <strong>og</strong><br />

<strong>for</strong>tjeneste pr. kg ved 1000 l. Metanolen kan <strong>og</strong>så leveres i 55 gallon tønder (lig 208 l). Ved så små<br />

leverancer tager Chemex 8,30 kr. pr. kg, svarende til 4,85 kr. pr. kg i levering. I praksis betyder det at<br />

Chemex tager ca. 800 kr. <strong>for</strong> levering uanset om der leveres 1000 l eller 208 l. Forskellen i antal leverede<br />

l. gør naturligvis at leverancer af 1000 l er meget billigere pr. l. end leveringer i 208 l. tønder. Ved 1000 l<br />

koster metanolen 4,31 kr. pr. l inkl. levering, medens den ved 208 l. tønder koster 6,57 kr. pr. l. inkl.<br />

levering. Til denne pris skal der lægges mineraliolieafgift, som man selv skal indberette til Skat.<br />

Mineralolieafgiften er på 1,857 kr. pr. l. For at få den endelige <strong>for</strong>brugerpris skal der tillægges moms. Ved<br />

1000 <strong>og</strong> 208 l bliver den pris <strong>for</strong>brugeren skal betale henholdsvis 7,71 <strong>og</strong> 10,53 kr. pr. l. Uden at vide det<br />

med sikkerhed vurderes det, at slutbrugeren vil sammenligne prisen på metanol med prisen på benzin <strong>og</strong><br />

diesel, hvor<strong>for</strong> det skal <strong>for</strong>søges at opnå priser pr. l. metanol der er sammenlignelige med disse. Prisen<br />

på 7,71 kr. pr. l. metanol er sammenlignelig med prisen på benzin <strong>og</strong> diesel, hvor<strong>for</strong> det vurderes at<br />

dette er en konkurrencedygtig pris. Prisen på 10,53 kr. pr. l. vurderes derimod at være i overkanten af<br />

hvad <strong>for</strong>brugerne vil godtage, hvis en større markedspenetrering skal finde sted.<br />

På nuværende tidspunkt er det ofte plejepersonale på plejehjem <strong>og</strong> i hjemmeplejen der sørger <strong>for</strong> at stille<br />

kørestolene til opladning. Ved et skift til metanol undgår man at stille kørestolen til opladning ca. hver<br />

anden dag, men kan nøjes med at tanke ca. en gang i ugen. Selve tankningen tager d<strong>og</strong> lidt længere tid,<br />

hvor<strong>for</strong> det ikke er muligt at sige n<strong>og</strong>et med sikkerhed om, den ene eller den anden løsning er den mest<br />

tidseffektive <strong>for</strong> plejepersonalet. Dette må bero på tests i virkeligheden, men der er en stor<br />

sandsynlighed <strong>for</strong>, at plejepersonalet vil opleve den nye optankningsmåde som værende tidsbesparende i<br />

<strong>for</strong>hold til den nuværende.<br />

2


Ifølge firmaet Trotters, der beskæftiger sig med rådgivning af farlig gods, må der distribueres op til 333<br />

kg metanol før metanolen er at betegne som farligt gods. Eftersom der ikke er behov <strong>for</strong> at distribuere<br />

333 kg. metanol af gangen i hjemmeplejen <strong>og</strong>/eller som privatpersoner anbefales det, at den praksis der<br />

opbygges omkring håndtering af metanol i hjemmeplejen, tilrettelægges sådan at der maksimalt<br />

distribueres 60 l metanol af gangen i 5 l dunke. 5 l. dunke vil på grund af metanols leve vægtdensitet<br />

veje mindre end 4,5 kg., hvilket gør at hjemmeplejens medarbejdere ikke belastes unødigt. Metanol kan<br />

distribueres <strong>og</strong> opbevares i HDPE-plasticdunke, som <strong>for</strong>brugerne kender fra de reservedunke der ligger i<br />

de fleste bilers bagagerum. Eftersom det anbefales at tankstørrelsen på Minicrosserne er på 3,5 – 5 l vil<br />

en eksternt tankstørrelse på 5 l være passende.<br />

Idet metanol er farligt ved oral indtagelse skal der sættes en lukkeanordning på dunkene, der gør, at det<br />

er umuligt at komme i direkte kontakt med metanolen. Et <strong>for</strong>holdsvist billigt, holdbart <strong>og</strong> brugervenligt<br />

system der vurderes at kunne løfte opgaven er det lukkede optankningssystem Flutite. Flutite<br />

koblingerne limes eller plastsvejes på HDPE-plastic dunkene, hvorved det sikres at påfyldning <strong>og</strong><br />

aftapning af metanol fra disse dunke kun kan ske når dunkene er koblet sammen. Alle dunke <strong>for</strong>synes<br />

med faremærkater <strong>og</strong> instrukser jf. gældende lovgivning.<br />

Politiet ønske at vide hvor der er metanol i Danmark. De ønsker at vide dette <strong>for</strong> at have overblik over<br />

steder hvor man evt. kan videre<strong>for</strong>arbejde metanol til ethanol (alm. alkohol). At få en polititilladelse er en<br />

<strong>for</strong>msag, <strong>og</strong> en sådan fås ved enten at printe <strong>for</strong>mular P302 ud fra politiets hjemmeside <strong>og</strong> indsende<br />

denne til politiet, eller ved at sælgeren af en Minicrosser kørestol med <strong>DMFC</strong> får brugeren til at udfylde<br />

<strong>for</strong>mularen med navn, adresse <strong>og</strong> underskrift, hvorefter denne sender <strong>for</strong>muleren ind til politiet. Ved<br />

levering af køretøj vedlægges en leverandørbrugsanvisning <strong>for</strong> metanol.<br />

Eftersom de nuværende batterier kun kan holde til 450 opladninger før de begynder at tabe ydelse, er<br />

der god sandsynlighed <strong>for</strong>, at de benyttede stakke kan få en betydelig længere levetid. Det anbefales at<br />

levetid på stakkene måles ved henholdsvis 1, 5, 10 <strong>og</strong> 20 % degradering. I praksis vil man først begynde<br />

at overveje en udskiftning af stakken ved 10 % degradering <strong>og</strong> vil sandsynligvis først udskifte denne ved<br />

minimum 20 % degradering. Det vurderes at mange nuværende kørestolsbrugere benytter batterier der<br />

er mere end 50 % degraderede. På nuværende tidspunkt skiftes batterierne typisk ved 1000 timer eller 2<br />

år, <strong>og</strong> det er denne levetid til en pris på 7367,50 kr. incl. moms. at <strong>DMFC</strong>-stakken konkurerer mod. Hvis<br />

stakken hypotetisk set kan holde i hele køretøjets levetid spares der ca. 30.000 kr. til udskiftning af<br />

batterier.<br />

Det anbefales at der i <strong>for</strong>bindelse med køleren i PowerPacken placeres en<br />

blæser. Den varme luft kan så blæses ud under køretøjet når PowerPacken<br />

placeres på en Minicroser T-140. Placeres Powerpacken derimod på en<br />

Minicrosser med kabine (se billede), kan den varme luft, når brugeren<br />

ønsker der blæses ind i kabinen, fra en luftdyse i stil med dem man kender<br />

fra instrumentbrættet i biler, blæse varm luft ud mellem benene på<br />

brugeren. Man får hermed muligheden <strong>for</strong> at opvarme kabinen <strong>for</strong> en<br />

estimeret merpris på maksimum et par hundrede kr. Denne pris skal<br />

sammenlignes med den nuværende retail ekstrapris <strong>for</strong> varme i kabine på<br />

ca. 1500 €. Hvis det kan lade sig gøre at designe tingene på denne måde<br />

kan Minicrosseren sælges betydeligt billigere <strong>og</strong>/eller der kan tjenes<br />

betydeligt mere på køretøjerne. For at få maksimal gavn af restvarmen<br />

anbefales det at man i en pilot test anvender Minicrossere med kabine.<br />

Det konkluderes at metanol <strong>og</strong> <strong>DMFC</strong> er interessante teknol<strong>og</strong>ier der kan give væsentlige <strong>for</strong>bedringer på<br />

parametre som driftstid, optankningstid <strong>og</strong> vægt. Det er endnu et åbent spørgsmål om<br />

vedligeholdelsesudgifterne bliver højere eller lavere end ved nuværende teknol<strong>og</strong>i. Den endelige<br />

konklusion er primært afhængig af levetiden på BC-stakken. Det er <strong>og</strong>så endnu et åbent spørgsmål om<br />

den samlede PowerPack kan produceres billigt nok til, at teknol<strong>og</strong>ien er et reelt alternativ til<br />

batteriteknol<strong>og</strong>ien.<br />

For yderligere in<strong>for</strong>mation<br />

Early market developer Per Koustrup, tlf. 96 27 56 08, mobil: 26 81 27 19, @: pk@h2l<strong>og</strong>ic.com<br />

Herning d. 9. januar 2007<br />

3


5<br />

5<br />

4<br />

4<br />

3<br />

D D<br />

Seriel data 1 Seriel data 1<br />

RS232 / Com 2<br />

Seriel data 2 Seriel data 2<br />

Seriel data 3 Seriel data 3<br />

C<br />

Seriel data 4<br />

Seriel data 5<br />

Seriel data 4<br />

Seriel data 5<br />

RS485 / Com 3<br />

C<br />

B<br />

DC/DC Enable<br />

Current control<br />

B<br />

<br />

OEM Controller<br />

24V<br />

12V<br />

5V<br />

3V3<br />

Key Input<br />

5V<br />

3V3<br />

SPI 1 (Data Bus)<br />

SPI 2 (Data Bus)<br />

A A<br />

3<br />

<br />

5V<br />

3V3<br />

SPI 1 (Data Bus)<br />

SPI 2 (Data Bus)<br />

<br />

24V<br />

12V<br />

5V<br />

3V3<br />

SPI 1 (Data Bus)<br />

SPI 2 (Data Bus)<br />

Seriel Com<br />

Output<br />

RS232 / Com 1<br />

CanBus 1<br />

CanBus 2<br />

5V<br />

<br />

5V<br />

Amplifier<br />

Current sensor 1<br />

3V3 3V3<br />

Current sensor 2<br />

Current sensor 3<br />

24V<br />

12V<br />

5V<br />

3V3<br />

SPI 1 (Data Bus)<br />

SPI 2 (Data Bus)<br />

<br />

24V<br />

12V<br />

5V<br />

3V3<br />

Key Input<br />

PowerSupply<br />

Power In<br />

Key Switch<br />

Level sensor 1<br />

Level sensor 2<br />

Stack Voltage<br />

Batteri Voltage<br />

<strong>DMFC</strong> Current Reguist<br />

Display Power<br />

<strong>DMFC</strong> Power<br />

OEM Power<br />

Power Connect Relay<br />

Drain Valve<br />

2<br />

2<br />

<strong>DMFC</strong> Projekt 1<br />

! " " #<br />

Sunday, March 30, 2008<br />

1<br />

1<br />

All Rights Reserved H2 L<strong>og</strong>ic ApS


<strong>DMFC</strong>?<br />

5<br />

5<br />

4<br />

4<br />

3<br />

D 24V<br />

D<br />

<br />

Power out<br />

Current reguest<br />

RS232 com<br />

0-5V<br />

0-50A<br />

12V-30V<br />

Current adjust<br />

0-9V<br />

0-50A<br />

21V-28.4V U?<br />

C C<br />

Level_Metanol<br />

Metanol container?<br />

<br />

Water container?<br />

B Water_out<br />

Water_out<br />

24V Power<br />

B<br />

Fuel_Level (AD)<br />

Water_Level (AD)<br />

U?<br />

Hais 50-s<br />

GND 4<br />

+5V 1<br />

OUT<br />

2<br />

Ref<br />

3<br />

DC/DC?<br />

Power in Power out DC/DC<br />

<br />

RS232 -2<br />

System Controller<br />

Enable (On/Off)<br />

Enable (On/Off)<br />

Current reguest<br />

Water_Level (AD)<br />

Fuel_Level (AD)<br />

System controller?<br />

Current adjust<br />

Current Adjust<br />

Stack voltage<br />

Stack Current<br />

Canbus [1..2]<br />

DC/DC Out Current<br />

Hais 50-s<br />

Batteri voltage<br />

GND 4<br />

+5V 1<br />

OUT<br />

2<br />

Ref<br />

3<br />

Power <strong>DMFC</strong><br />

24V Power<br />

LS1A<br />

5<br />

3<br />

4<br />

24V relay 60A<br />

A A<br />

3<br />

LS1B<br />

System Connect<br />

1<br />

2<br />

24V relay 60A<br />

Motor Current<br />

Key switch<br />

RS232 -1 [1..2]<br />

Control / warning 1<br />

Control / warning 2<br />

F?<br />

50A<br />

Batteri bank?<br />

24V Power batteri Batteri out<br />

Batteri 24V<br />

(2*12V)<br />

Panasonic 12V / 20Ah<br />

Display?<br />

RS232 -1 [1..2]<br />

Display<br />

U?<br />

Hais 200-s<br />

2<br />

GND 4<br />

+5V 1<br />

OUT<br />

2<br />

Ref<br />

3<br />

2<br />

Mini Crosser<br />

F?<br />

FUSE<br />

Motor controll?<br />

Batteri<br />

<br />

Key switch (+24V)<br />

<strong>DMFC</strong> Projekt 1<br />

!<br />

Friday, March 28, 2008<br />

1<br />

1<br />

Motor<br />

24V 750W<br />

All Rights Reserved H2 L<strong>og</strong>ic ApS