Krav Spec <strong>for</strong> <strong>DMFC</strong> Modul <strong>for</strong> <strong>intern</strong> <strong>transport</strong> <strong>og</strong> <strong>mobile</strong> <strong>anlæg</strong><br />
No of cells 35<br />
Fuel Supply Methanol / Air<br />
Stack Power, nominal 630 W<br />
Stack Power, max 800 W<br />
Stack Current, nominal 45 A<br />
Stack Voltage, nominal @ B-o-L 14 V<br />
Heat, P W [HHV] 1335 W<br />
Operating stack temperature, nominal 70-75°C<br />
Fuel pressure (max) 0.05 bar(g)<br />
Water Consumption rate (λ=1) 0.18 kg/h<br />
Methanol Consumption rate (λ=1) 0.40 l/h<br />
Air Consumption rate(λ=1) 1.57 Nm 3 /h<br />
Air pressure ambient<br />
Air supply rate (λ=3.0) 4.72 Nm 3 /h<br />
Internal methanol supply concentration 1.0 M<br />
Fuel circulation flow rate @ 1.0M, nominal 58.7 l/h<br />
Mechanical:<br />
Stack Dimensions (excl. connectors) 171 mm x 184 mm x 184 mm<br />
Stack Weight ~ 7 kg<br />
Tabel 1.2.2.<br />